메뉴 건너뛰기




Volumn 113, Issue 6, 2011, Pages 1292-1294

Validation of the MostCare pulse contour cardiac output monitor: Beyond the bland and altman plot

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTIC METHOD; CALIBRATION; CARDIOVASCULAR EQUIPMENT; HEART FAILURE; HEART OUTPUT; HEART OUTPUT MEASUREMENT; HUMAN; PATIENT MONITORING; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; REVIEW; THERMODILUTION;

EID: 82255180288     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/ANE.0b013e31822d6785     Document Type: Review
Times cited : (20)

References (12)
  • 1
    • 78149469431 scopus 로고    scopus 로고
    • A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
    • Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010;111:1180-92
    • (2010) Anesth Analg , vol.111 , pp. 1180-1192
    • Critchley, L.A.1    Lee, A.2    Ho, A.M.3
  • 2
    • 61949284877 scopus 로고    scopus 로고
    • Minimally invasive cardiac output monitoring in the perioperative setting
    • Funk DJ, Moretti EW, Gan TJ. Minimally invasive cardiac output monitoring in the perioperative setting. Anesth Analg 2009;108:887-97
    • (2009) Anesth Analg , vol.108 , pp. 887-897
    • Funk, D.J.1    Moretti, E.W.2    Gan, T.J.3
  • 3
    • 70449475939 scopus 로고    scopus 로고
    • Cardiac output derived from arterial pressure waveform
    • Mayer J, Suttner S. Cardiac output derived from arterial pressure waveform. Curr Opin Anaesthesiol 2009;22:804-8
    • (2009) Curr. Opin. Anaesthesiol. , vol.22 , pp. 804-808
    • Mayer, J.1    Suttner, S.2
  • 4
    • 82255192417 scopus 로고    scopus 로고
    • An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation
    • Scolletta S, Franchi F, Taccone FS, Donadello K, Vincent JL. An uncalibrated pulse contour method to measure cardiac output during aortic counterpulsation. Anesth Analg 2011;113:1389-95
    • (2011) Anesth Analg , vol.113 , pp. 1389-1395
    • Scolletta, S.1    Franchi, F.2    Taccone, F.S.3    Donadello, K.4    Vincent, J.L.5
  • 5
    • 0036342701 scopus 로고    scopus 로고
    • Assessment of cardiac output from systemic arterial pressure in humans
    • Romano SM, Pistolesi M. Assessment of cardiac output from systemic arterial pressure in humans. Crit Care Med 2002;30:1834-41 (Pubitemid 34879600)
    • (2002) Critical Care Medicine , vol.30 , Issue.8 , pp. 1834-1841
    • Romano, S.M.1    Pistolesi, M.2
  • 6
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999;15:85-91 (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 7
    • 78650944099 scopus 로고    scopus 로고
    • Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig
    • Yang XX, Critchley LA, Joynt GM. Determination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig. Anesth Analg 2011;112:70-7
    • (2011) Anesth Analg , vol.112 , pp. 70-77
    • Yang, X.X.1    Critchley, L.A.2    Joynt, G.M.3
  • 8
    • 77949305811 scopus 로고    scopus 로고
    • Cardiac output monitoring using indicator-dilution techniques: Basics limits and perspectives
    • Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg 2010;110:799-811
    • (2010) Anesth Analg , vol.110 , pp. 799-811
    • Reuter, D.A.1    Huang, C.2    Edrich, T.3    Shernan, S.K.4    Eltzschig, H.K.5
  • 9
    • 79952935360 scopus 로고    scopus 로고
    • Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients
    • Paarmann H, Groesdonk HV, Sedemund-Adib B, Hanke T, Heinze H, Heringlake M, Schön J. Lack of agreement between pulmonary arterial thermodilution cardiac output and the pressure recording analytical method in postoperative cardiac surgery patients. Br J Anaesth 2011;106:475-81
    • (2011) Br. J. Anaesth , vol.106 , pp. 475-481
    • Paarmann, H.1    Groesdonk, H.V.2    Sedemund-Adib, B.3    Hanke, T.4    Heinze, H.5    Heringlake, M.6    Schön, J.7
  • 10
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10
    • (1986) Lancet , vol.1 , pp. 307-110
    • Bland, J.M.1    Altman, D.G.2
  • 11
    • 79957736830 scopus 로고    scopus 로고
    • Assessment of trending ability of cardiac output monitors by polar plot methodology
    • Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth 2011;25:536-46
    • (2011) J. Cardiothorac. Vasc. Anesth , vol.25 , pp. 536-546
    • Critchley, L.A.1    Yang, X.X.2    Lee, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.