Volumn 12, Issue 4, 2011, Pages 15-23

Increased beam attenuation and surface dose by different couch inserts of treatment tables used in megavoltage radiotherapy

Author keywords

Beam attenuation; Carbon fiber; Couch insert; Skin sparing; Surface dose

Indexed keywords


EID: 81855177021     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v12i4.3554     Document Type: Article
Times cited : (33)

References (22)
  • 1
    • 0031954692 scopus 로고    scopus 로고
    • An investigation into the use of carbon fibre for megavoltage radiotherapy applications
    • Meara SJ and Langmack KA. An investigation into the use of carbon fibre for megavoltage radiotherapy applications. Phys Med Biol. 998;43(5):1359-66.
    • (1998) Phys Med Biol , vol.43 , Issue.5 , pp. 1359-1366
    • Meara, S.J.1    Langmack, K.A.2
  • 2
    • 56349111938 scopus 로고    scopus 로고
    • Acute skin toxicity following stereotactic body radiation therapy for stage 1 non-small-cell lung cancer: who's at risk?
    • Hoppe BS, Laser B, Kowalski AV, et al. Acute skin toxicity following stereotactic body radiation therapy for stage 1 non-small-cell lung cancer: who's at risk? Int J Radiat Oncol Biol Phys. 2008;72(5):1283-86.
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , Issue.5 , pp. 1283-1286
    • Hoppe, B.S.1    Laser, B.2    Kowalski, A.V.3
  • 3
    • 0030786706 scopus 로고    scopus 로고
    • The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams
    • De Ost B, Vanregemorter J, Schaeken B, Van den Weyngaert D. The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams. Radiother Oncol. 1997;45(3):275-77.
    • (1997) Radiother Oncol , vol.45 , Issue.3 , pp. 275-277
    • De Ost, B.1    Vanregemorter, J.2    Schaeken, B.3    Van den Weyngaert, D.4
  • 4
    • 0034749407 scopus 로고    scopus 로고
    • The effect of carbon fiber couch inserts on surface dose with beam size variation
    • Higgins DM, Whitehurst P, Morgan A. The effect of carbon fiber couch inserts on surface dose with beam size variation. Med Dosim. 2001;26(3):251-54.
    • (2001) Med Dosim , vol.26 , Issue.3 , pp. 251-254
    • Higgins, D.M.1    Whitehurst, P.2    Morgan, A.3
  • 5
    • 20444386191 scopus 로고    scopus 로고
    • Evaluation of the Sinmed Mastercouch as replacement for a standard couch
    • Gillis S, Bral S, De Wagter C, et al. Evaluation of the Sinmed Mastercouch as replacement for a standard couch. Radiother Oncol. 2005;75(2):227-36.
    • (2005) Radiother Oncol , vol.75 , Issue.2 , pp. 227-236
    • Gillis, S.1    Bral, S.2    De Wagter, C.3
  • 6
    • 14644398526 scopus 로고    scopus 로고
    • The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert
    • McCormack S, Diffey J, Morgan AM. The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert. Med Phys. 2005;32(2):483-87.
    • (2005) Med Phys , vol.32 , Issue.2 , pp. 483-487
    • McCormack, S.1    Diffey, J.2    Morgan, A.M.3
  • 7
    • 34548280321 scopus 로고    scopus 로고
    • Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop
    • Myint WK, Niedbala M, Wilkins D, Gerig LH. Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop. J Appl Clin Med Phys. 2006;7(3):21-27.
    • (2006) J Appl Clin Med Phys , vol.7 , Issue.3 , pp. 21-27
    • Myint, W.K.1    Niedbala, M.2    Wilkins, D.3    Gerig, L.H.4
  • 8
    • 36049042033 scopus 로고    scopus 로고
    • Megavoltage x-ray skin dose variation with an angle using grid carbon fibre couch tops
    • Butson MJ, Cheung T, Yu PK. Megavoltage x-ray skin dose variation with an angle using grid carbon fibre couch tops. Phys Med Biol. 2007;52(20):N485-N492.
    • (2007) Phys Med Biol , vol.52 , Issue.20
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.3
  • 9
    • 33846406387 scopus 로고    scopus 로고
    • The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams
    • Poppe B, Chofor N, Rühmann A, et al. The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams. Strahlenther Onkol. 2007;183(1):43-48.
    • (2007) Strahlenther Onkol , vol.183 , Issue.1 , pp. 43-48
    • Poppe, B.1    Chofor, N.2    Rühmann, A.3
  • 10
    • 54949116628 scopus 로고    scopus 로고
    • Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system
    • Mihaylov IB, Corry P, Yan Y, Ratanatharathorn V, Moros EG. Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system. Med Phys. 2008;35(11):4982-88.
    • (2008) Med Phys , vol.35 , Issue.11 , pp. 4982-4988
    • Mihaylov, I.B.1    Corry, P.2    Yan, Y.3    Ratanatharathorn, V.4    Moros, E.G.5
  • 11
    • 53049101856 scopus 로고    scopus 로고
    • Evaluating the influence of the Siemens IGRT carbon fibre tabletop in head and neck IMRT
    • Spezi E, Angelini AL, Romani F, et al. Evaluating the influence of the Siemens IGRT carbon fibre tabletop in head and neck IMRT. Radiother Oncol. 2008;89(1):114-22.
    • (2008) Radiother Oncol , vol.89 , Issue.1 , pp. 114-122
    • Spezi, E.1    Angelini, A.L.2    Romani, F.3
  • 12
    • 77749233768 scopus 로고    scopus 로고
    • Determination of the photon beam attenuation by the Brainlab imaging couch: angular and field size dependence
    • Njeh CF, Raines TW, Saunders MW. Determination of the photon beam attenuation by the Brainlab imaging couch: angular and field size dependence. J Appl Clin Med Phys. 2009;10(3):16-27.
    • (2009) J Appl Clin Med Phys , vol.10 , Issue.3 , pp. 16-27
    • Njeh, C.F.1    Raines, T.W.2    Saunders, M.W.3
  • 13
    • 73649100241 scopus 로고    scopus 로고
    • Dose perturbations by two carbon fiber treatment couches and the ability of a commercial treatment planning system to predict these effects
    • Gerig LH, Niedbala M, Nyiri BJ. Dose perturbations by two carbon fiber treatment couches and the ability of a commercial treatment planning system to predict these effects. Med Phys. 2010;37(1):322-28.
    • (2010) Med Phys , vol.37 , Issue.1 , pp. 322-328
    • Gerig, L.H.1    Niedbala, M.2    Nyiri, B.J.3
  • 15
    • 0025021187 scopus 로고
    • Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers
    • Gerbi BJ, Khan FM. Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers. Med Phys. 1990;17(1):17-26.
    • (1990) Med Phys , vol.17 , Issue.1 , pp. 17-26
    • Gerbi, B.J.1    Khan, F.M.2
  • 16
    • 0003954913 scopus 로고    scopus 로고
    • 3rd ed. Philadelphia: Lippincott Williams & Wilkins;
    • Khan FM. The physics of radiation therapy, 3rd ed. Philadelphia: Lippincott Williams & Wilkins; 2003.
    • (2003) The physics of radiation therapy
    • Khan, F.M.1
  • 17
    • 67651214053 scopus 로고    scopus 로고
    • Skin dose impact from vacuum immobilization device and carbon fiber couch in intensity modulated radiation therapy for prostate cancer
    • Lee KW, Wu JK, Jeng SC, Hsueh Liu YW, Cheng JC. Skin dose impact from vacuum immobilization device and carbon fiber couch in intensity modulated radiation therapy for prostate cancer. Med Dosim. 2009;34(3):228-32.
    • (2009) Med Dosim , vol.34 , Issue.3 , pp. 228-232
    • Lee, K.W.1    Wu, J.K.2    Jeng, S.C.3    Hsueh Liu, Y.W.4    Cheng, J.C.5
  • 19
    • 0031800667 scopus 로고    scopus 로고
    • A dielectric method for measuring early and late reactions in irradiated human skin
    • Nuutinen J, Lahtinen T, Turunen M, et al. A dielectric method for measuring early and late reactions in irradiated human skin. Radiother Oncol. 1998;47(3):249-54.
    • (1998) Radiother Oncol , vol.47 , Issue.3 , pp. 249-254
    • Nuutinen, J.1    Lahtinen, T.2    Turunen, M.3