메뉴 건너뛰기




Volumn 89, Issue 1, 2008, Pages 114-122

Evaluating the influence of the Siemens IGRT carbon fibre tabletop in head and neck IMRT

Author keywords

Couch attenuation; IMRT; Plan optimization; Radiotherapy; Treatment planning

Indexed keywords

CARBON FIBER;

EID: 53049101856     PISSN: 01678140     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.radonc.2008.06.011     Document Type: Article
Times cited : (35)

References (19)
  • 1
    • 0032959080 scopus 로고    scopus 로고
    • A method of beam couch intersection detection
    • Muthuswamy M.S., and Lam K.L. A method of beam couch intersection detection. Med Phys 26 (1999) 229-235
    • (1999) Med Phys , vol.26 , pp. 229-235
    • Muthuswamy, M.S.1    Lam, K.L.2
  • 2
    • 19544363601 scopus 로고    scopus 로고
    • An algorithm for detection of couch-beam intersection
    • Buckle A.H. An algorithm for detection of couch-beam intersection. Med Dosim 30 (2005) 65-68
    • (2005) Med Dosim , vol.30 , pp. 65-68
    • Buckle, A.H.1
  • 3
    • 0034813454 scopus 로고    scopus 로고
    • Accommodation of couch constraints for coplanar intensity modulated radiation therapy
    • Meyer J., Mills J.A., Haas O.C., Burnham K.J., and Parvin E.M. Accommodation of couch constraints for coplanar intensity modulated radiation therapy. Radiother Oncol 61 (2001) 23-32
    • (2001) Radiother Oncol , vol.61 , pp. 23-32
    • Meyer, J.1    Mills, J.A.2    Haas, O.C.3    Burnham, K.J.4    Parvin, E.M.5
  • 4
    • 0030786706 scopus 로고    scopus 로고
    • The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams
    • De Ost B., Vanregemorter J., Schaeken B., and Van den Weyngaert D. The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams. Radiother Oncol 45 (1997) 275-277
    • (1997) Radiother Oncol , vol.45 , pp. 275-277
    • De Ost, B.1    Vanregemorter, J.2    Schaeken, B.3    Van den Weyngaert, D.4
  • 5
    • 0031954692 scopus 로고    scopus 로고
    • An investigation into the use of carbon fibre for megavoltage radiotherapy applications
    • Meara S.J., and Langmack K.A. An investigation into the use of carbon fibre for megavoltage radiotherapy applications. Phys Med Biol 43 (1998) 1359-1366
    • (1998) Phys Med Biol , vol.43 , pp. 1359-1366
    • Meara, S.J.1    Langmack, K.A.2
  • 6
    • 0034749407 scopus 로고    scopus 로고
    • The effect of carbon fiber couch inserts on surface dose with beam size variations
    • Higgins D.M., Whitehurst P., and Morgan A.M. The effect of carbon fiber couch inserts on surface dose with beam size variations. Med Dosim 26 (2001) 251-254
    • (2001) Med Dosim , vol.26 , pp. 251-254
    • Higgins, D.M.1    Whitehurst, P.2    Morgan, A.M.3
  • 7
    • 14644398526 scopus 로고    scopus 로고
    • The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert
    • McCormack S., Diffey J., and Morgan A. The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert. Med Phys 32 (2005) 483-487
    • (2005) Med Phys , vol.32 , pp. 483-487
    • McCormack, S.1    Diffey, J.2    Morgan, A.3
  • 8
    • 0345688217 scopus 로고    scopus 로고
    • Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device
    • Vieira S.C., Kaatee R.S., Dirkx M.L., and Heijmen B.J. Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device. Med Phys 30 (2003) 2981-2987
    • (2003) Med Phys , vol.30 , pp. 2981-2987
    • Vieira, S.C.1    Kaatee, R.S.2    Dirkx, M.L.3    Heijmen, B.J.4
  • 9
    • 35549012420 scopus 로고    scopus 로고
    • Dosimetric characteristics of the Siemens IGRT carbon fiber tabletop
    • Spezi E., and Ferri A. Dosimetric characteristics of the Siemens IGRT carbon fiber tabletop. Med Dosim (2007) 295-298
    • (2007) Med Dosim , pp. 295-298
    • Spezi, E.1    Ferri, A.2
  • 10
    • 33846406387 scopus 로고    scopus 로고
    • The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams
    • Poppe B., Chofor N., Rühmann A., Kunth W., Djouguela A., Kollhoff R., et al. The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams. Strahlenther Onkol 183 (2007) 43-48
    • (2007) Strahlenther Onkol , vol.183 , pp. 43-48
    • Poppe, B.1    Chofor, N.2    Rühmann, A.3    Kunth, W.4    Djouguela, A.5    Kollhoff, R.6
  • 11
    • 34548280321 scopus 로고    scopus 로고
    • Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop
    • Myint W.K., Niedbala M., Wilkins D., and Gerig L.H. Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop. J Appl Clin Med Phys 7 (2006) 21-27
    • (2006) J Appl Clin Med Phys , vol.7 , pp. 21-27
    • Myint, W.K.1    Niedbala, M.2    Wilkins, D.3    Gerig, L.H.4
  • 12
    • 36049042033 scopus 로고    scopus 로고
    • Variations in skin dose associated with linac bed material at 6 MV x-ray energy
    • Butson M.J., Cheung T., and Yu P.K. Variations in skin dose associated with linac bed material at 6 MV x-ray energy. Phys Med Biol 52 (2007) N485-N492
    • (2007) Phys Med Biol , vol.52
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.3
  • 14
    • 33746874521 scopus 로고    scopus 로고
    • Impact of 6 MV photon beam attenuation by carbon fiber couch and immobilization devices in IMRT planning and dose delivery
    • Munjal R.K., Negi P.S., Babu A.G., Sinha S.N., Anand A.K., and Kataria T. Impact of 6 MV photon beam attenuation by carbon fiber couch and immobilization devices in IMRT planning and dose delivery. J Med Phys 31 (2006) 67-71
    • (2006) J Med Phys , vol.31 , pp. 67-71
    • Munjal, R.K.1    Negi, P.S.2    Babu, A.G.3    Sinha, S.N.4    Anand, A.K.5    Kataria, T.6
  • 15
    • 12144289319 scopus 로고    scopus 로고
    • Implementing IMRT in clinical practice: a joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine
    • Galvin J.M., Ezzell G., Eisbrauch A., Yu C., Butler B., Xiao Y., et al. Implementing IMRT in clinical practice: a joint document of the American Society for Therapeutic Radiology and Oncology and the American Association of Physicists in Medicine. Int J Radiat Oncol Biol Phys 58 (2004) 1616-1634
    • (2004) Int J Radiat Oncol Biol Phys , vol.58 , pp. 1616-1634
    • Galvin, J.M.1    Ezzell, G.2    Eisbrauch, A.3    Yu, C.4    Butler, B.5    Xiao, Y.6
  • 16
    • 22244450090 scopus 로고    scopus 로고
    • Characterization of a 2D ion chamber array for the verification of radiotherapy treatments
    • Spezi E., Angelini A.L., Romani F., and Ferri A. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments. Phys Med Biol 50 (2005) 3361-3373
    • (2005) Phys Med Biol , vol.50 , pp. 3361-3373
    • Spezi, E.1    Angelini, A.L.2    Romani, F.3    Ferri, A.4
  • 17
    • 0037572347 scopus 로고    scopus 로고
    • CERR: a computational environment for radiotherapy research
    • Deasy J.O., Blanco A.I., and Clark V.H. CERR: a computational environment for radiotherapy research. Med Phys 5 (2003) 979-985
    • (2003) Med Phys , vol.5 , pp. 979-985
    • Deasy, J.O.1    Blanco, A.I.2    Clark, V.H.3
  • 19
    • 34347388219 scopus 로고    scopus 로고
    • IMAT-SIM: a new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT)
    • Iori M., Cagni E., Nahum A.E., and Borasi G. IMAT-SIM: a new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT). Med Phys 34 (2007) 2759-2773
    • (2007) Med Phys , vol.34 , pp. 2759-2773
    • Iori, M.1    Cagni, E.2    Nahum, A.E.3    Borasi, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.