메뉴 건너뛰기




Volumn 37, Issue 1, 2010, Pages 322-328

Dose perturbations by two carbon fiber treatment couches and the ability of a commercial treatment planning system to predict these effects

Author keywords

Buildup; Carbon fiber; Skin dose; Surface dose; Treatment couch; Treatment planning

Indexed keywords

CARBON FIBERS; GRAPHITE FIBERS; IONIZATION CHAMBERS; PHANTOMS; SURFACE TREATMENT;

EID: 73649100241     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3271364     Document Type: Article
Times cited : (38)

References (48)
  • 1
    • 0026075117 scopus 로고
    • The use of carbon fibers in radiotherapy
    • 0167-8140. 10.1016/0167-8140(91)90010-E
    • L. G. de Mooy, " The use of carbon fibers in radiotherapy.," Radiother. Oncol. 0167-8140 22, 140-142 (1991). 10.1016/0167-8140(91)90010-E
    • (1991) Radiother. Oncol. , vol.22 , pp. 140-142
    • De Mooy, L.G.1
  • 2
    • 53049101856 scopus 로고    scopus 로고
    • Evaluating the influence of the siemens IGRT carbon fibre tabletop in head and neck IMRT
    • 0167-8140. 10.1016/j.radonc.2008.06.011
    • E. Spezi, A. Angelini, F. Romani, A. Guido, F. Bunkheila, M. Ntreta, and A. Ferri, " Evaluating the influence of the siemens IGRT carbon fibre tabletop in head and neck IMRT.," Radiother. Oncol. 0167-8140 89 (1), 114-122 (2008). 10.1016/j.radonc.2008.06.011
    • (2008) Radiother. Oncol. , vol.89 , Issue.1 , pp. 114-122
    • Spezi, E.1    Angelini, A.2    Romani, F.3    Guido, A.4    Bunkheila, F.5    Ntreta, M.6    Ferri, A.7
  • 3
    • 0024512544 scopus 로고
    • The geometry of avoiding beam intersections and blocking tray collisions
    • DOI 10.1118/1.596379
    • E. D. Yorke, " The geometry of avoiding beam intersections and blocking tray collisions.," Med. Phys. 0094-2405 16 (2), 288-291 (1989). 10.1118/1.596379 (Pubitemid 19112060)
    • (1989) Medical Physics , vol.16 , Issue.2 , pp. 288-291
    • Yorke, E.D.1
  • 4
    • 34548280321 scopus 로고    scopus 로고
    • Investigating treatment dose error due to beam attenuation by a carbon fibre tabletop
    • 1526-9914. 10.1120/jacmv7i3.2247
    • W. K. Myint, M. Niedbala, D. Wilkins, and L. H. Gerig, " Investigating treatment dose error due to beam attenuation by a carbon fibre tabletop.," J. Appl. Clin. Med. Phys. 1526-9914 7 (3), 21-27 (2006). 10.1120/jacmp.v7i3.2247
    • (2006) J. Appl. Clin. Med. Phys. , vol.7 , Issue.3 , pp. 21-27
    • Myint, W.K.1    Niedbala, M.2    Wilkins, D.3    Gerig, L.H.4
  • 5
    • 14644398526 scopus 로고    scopus 로고
    • The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert
    • DOI 10.1118/1.1852792
    • S. McCormack, J. Diffey, and A. Morgan, " The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert.," Med. Phys. 0094-2405 32 (2), 483-487 (2005). 10.1118/1.1852792 (Pubitemid 40322330)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 483-487
    • McCormack, S.1    Diffey, J.2    Morgan, A.3
  • 6
    • 0345688217 scopus 로고    scopus 로고
    • Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device
    • DOI 10.1118/1.1620491
    • S. C. Vieira, R. S. J. P. Kaatee, M. L. P. Dirkx, and B. J. M. Heijmen, " Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device.," Med. Phys. 0094-2405 30 (11), 2981-2987 (2003). 10.1118/1.1620491 (Pubitemid 37444308)
    • (2003) Medical Physics , vol.30 , Issue.11 , pp. 2981-2987
    • Vieira, S.C.1    Kaatee, R.S.J.P.2    Dirkx, M.L.P.3    Heijmen, B.J.M.4
  • 7
    • 33846406387 scopus 로고    scopus 로고
    • The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams
    • DOI 10.1007/s00066-007-1582-8
    • B. Poppe, N. Chofor, A. Rahmann, W. Kunth, A. Djouguela, R. Kollhoff, and K. C. Willborn, " The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams.," Strahlenther. Onkol. 0179-7158 183 (1), 43-48 (2007). 10.1007/s00066-007-1582-8 (Pubitemid 46144104)
    • (2007) Strahlentherapie und Onkologie , vol.183 , Issue.1 , pp. 43-48
    • Poppe, B.1    Chofor, N.2    Ruhmann, A.3    Kunth, W.4    Djouguela, A.5    Kollhoff, R.6    Willborn, K.C.7
  • 8
    • 12844269162 scopus 로고    scopus 로고
    • Validation of Monte Carlo calculated surface doses for megavoltage photon beams
    • DOI 10.1118/1.1829401
    • W. Abdel-Rahman, J. P. Seuntjens, F. Verhaegen, F. Debois, and E. B. Podgorsak, " Validation of Monte Carlo calculated surface doses for megavoltage photon beams.," Med. Phys. 0094-2405 32 (1), 286-298 (2005). 10.1118/1.1829401 (Pubitemid 40165541)
    • (2005) Medical Physics , vol.32 , Issue.1 , pp. 286-298
    • Abdel-Rahman, W.1    Seuntjens, J.P.2    Verhaegen, F.3    Deblois, F.4    Podgorsak, E.B.5
  • 9
    • 4644295340 scopus 로고    scopus 로고
    • Ionization chamber-based reference dosimetry of intensity modulated radiation beams
    • DOI 10.1118/1.1781333
    • H. Bouchard and J. Seuntjens, " Ionization chamber-based reference dosimetry of intensity modulated radiation beams.," Med. Phys. 0094-2405 31 (9), 2454-2465 (2004). 10.1118/1.1781333 (Pubitemid 39287859)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2454-2465
    • Bouchard, H.1    Seuntjens, J.2
  • 10
    • 0036130664 scopus 로고    scopus 로고
    • Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters
    • DOI 10.1118/1.1446109
    • D. Sheikh-Bagheri and D. W. O. Rogers, " Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters.," Med. Phys. 0094-2405 29 (3), 379-390 (2002). 10.1118/1.1446109 (Pubitemid 34241161)
    • (2002) Medical Physics , vol.29 , Issue.3 , pp. 379-390
    • Sheikh-Bagheri, D.1    Rogers, D.W.O.2
  • 11
    • 0036852567 scopus 로고    scopus 로고
    • Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam
    • DOI 10.1118/1.1514237
    • G. X. Ding, " Dose discrepancies between Monte Carlo calculations and measurements in the build-up region for a high-energy photon beam.," Med. Phys. 0094-2405 29 (11), 2459-2463 (2002). 10.1118/1.1514237 (Pubitemid 35375443)
    • (2002) Medical Physics , vol.29 , Issue.11 , pp. 2459-2463
    • Ding, G.X.1
  • 12
    • 0026549406 scopus 로고
    • Experimental determination of wall correction factors. Part II: NACP and Markus plane-parallel ionization chambers
    • 0031-9155. 10.1088/0031-9155/37/4/013
    • F. W. Wittkämper, A. H. L. Albers, and B. J. Mijnheer, " Experimental determination of wall correction factors. Part II: NACP and Markus plane-parallel ionization chambers.," Phys. Med. Biol. 0031-9155 37, 995-1004 (1992). 10.1088/0031-9155/37/4/013
    • (1992) Phys. Med. Biol. , vol.37 , pp. 995-1004
    • Wittkämper, F.W.1    Albers, A.H.L.2    Mijnheer, B.J.3
  • 13
    • 0037323312 scopus 로고    scopus 로고
    • 60Co beams using the EGSnrc Monte Carlo code
    • DOI 10.1118/1.1536291
    • E. Mainegra-Hing, I. Kawrakow, and D. W. O. Rogers, " Calculations for plane-parallel ion chambers in 60Co beams using the EGSnrc Monte Carlo code.," Med. Phys. 0094-2405 30 (2), 179-189 (2003). 10.1118/1.1536291 (Pubitemid 36222853)
    • (2003) Medical Physics , vol.30 , Issue.2 , pp. 179-189
    • Mainegra-Hing, E.1    Kawrakow, I.2    Rogers, D.W.O.3
  • 14
    • 33744820051 scopus 로고    scopus 로고
    • wall, for parallel-plate ionization chambers
    • DOI 10.1118/1.2199988
    • L. A. Buckley and D. W. O. Rogers, " Wall correction factors, Pwall, for parallel-plate ionization chambers.," Med. Phys. 0094-2405 33 (6), 1788-1796 (2006). 10.1118/1.2199988 (Pubitemid 43830267)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1788-1796
    • Buckley, L.A.1    Rogers, D.W.O.2
  • 15
    • 0031942917 scopus 로고    scopus 로고
    • A new approach to electron-beam reference dosimetry
    • DOI 10.1118/1.598211
    • D. W. O. Rogers, " A new approach to electron-beam reference dosimetry.," Med. Phys. 0094-2405 25 (3), 310-320 (1998). 10.1118/1.598211 (Pubitemid 28146387)
    • (1998) Medical Physics , vol.25 , Issue.3 , pp. 310-320
    • Rogers, D.W.O.1
  • 16
    • 0016652027 scopus 로고
    • Build-up region of megavoltage photon radiation sources
    • 0094-2405. 10.1118/1.594158
    • D. E. Velkley, D. J. Manson, J. A. Purdy, and G. D. Oliver, Jr., " Build-up region of megavoltage photon radiation sources.," Med. Phys. 0094-2405 2 (1), 14-19 (1975). 10.1118/1.594158
    • (1975) Med. Phys. , vol.2 , Issue.1 , pp. 14-19
    • Velkley, D.E.1    Manson, D.J.2    Purdy, J.A.3    Oliver Jr., G.D.4
  • 17
    • 0025021187 scopus 로고
    • Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers
    • DOI 10.1118/1.596522
    • B. J. Gerbi and F. M. Khan, " Measurement of dose in the build-up region using fixed-separation plane-parallel ionization chambers.," Med. Phys. 0094-2405 17 (1), 17-26 (1990). 10.1118/1.596522 (Pubitemid 20073163)
    • (1990) Medical Physics , vol.17 , Issue.1 , pp. 17-26
    • Gerbi, B.J.1    Khan, F.M.2
  • 18
    • 40049109564 scopus 로고    scopus 로고
    • The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams
    • DOI 10.1118/1.2839329
    • M. R. McEwen, I. Kawrakow, and C. K. Ross, " The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams.," Med. Phys. 0094-2405 35 (3), 950-958 (2008). 10.1118/1.2839329 (Pubitemid 351322676)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 950-958
    • McEwen, M.R.1    Kawrakow, I.2    Ross, C.K.3
  • 19
    • 33744828302 scopus 로고    scopus 로고
    • On the effective point of measurement in megavoltage photon beams
    • DOI 10.1118/1.2201147
    • I. Kawrakow, " On the effective point of measurement in megavoltage photon beams.," Med. Phys. 0094-2405 33 (6), 1829-1839 (2006). 10.1118/1.2201147 (Pubitemid 43830271)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1829-1839
    • Kawrakow, I.1
  • 20
    • 0030786706 scopus 로고    scopus 로고
    • The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams
    • DOI 10.1016/S0167-8140(97)00118-7, PII S0167814097001187
    • B. De Ost, J. Vanregemorter, B. Schaeken, and D. Van den Weyngaert, " The effect of carbon fibre inserts on the build-up and attenuation of high energy photon beams.," Radiother. Oncol. 0167-8140 45 (3), 275-277 (1997). 10.1016/S0167-8140(97)00118-7 (Pubitemid 27515179)
    • (1997) Radiotherapy and Oncology , vol.45 , Issue.3 , pp. 275-277
    • De Ost, B.1    Vanregemorter, J.2    Schaeken, B.3    Van Den Weyngaert, D.4
  • 21
    • 0037035946 scopus 로고    scopus 로고
    • Measurement of skin dose variations produced by a silicon-based protective dressing in radiotherapy
    • DOI 10.1088/0031-9155/47/11/402, PII S003191550233714X
    • M. J. Butson, T. Cheung, P. K. N. Yu, and P. Metcalfe, " Measurement of skin dose variations produced by a silicon-based protective dressing in radiotherapy.," Phys. Med. Biol. 0031-9155 47, N145-N151 (2002). 10.1088/0031-9155/47/11/402 (Pubitemid 34662210)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.11
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3    Metcalfe, P.4
  • 22
    • 0034192254 scopus 로고    scopus 로고
    • Skin damage probabilities using fixation materials in high-energy photon beams
    • DOI 10.1016/S0167-8140(00)00177-8, PII S0167814000001778
    • J. Carl and A. Vestergaard, " Skin damage probabilities using fixation materials in high-energy photon beams.," Radiother. Oncol. 0167-8140 55 (2), 191-198 (2000). 10.1016/S0167-8140(00)00177-8 (Pubitemid 30229995)
    • (2000) Radiotherapy and Oncology , vol.55 , Issue.2 , pp. 191-198
    • Carl, J.1    Vestergaard, A.2
  • 23
    • 0029127697 scopus 로고
    • Dose behind various immobilization and beam-modifying devices
    • 0360-3016. 10.1016/0360-3016(94)00371-Q
    • D. E. Mellenberg, " Dose behind various immobilization and beam-modifying devices.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 32, 1193-1197 (1995). 10.1016/0360-3016(94)00371-Q
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.32 , pp. 1193-1197
    • Mellenberg, D.E.1
  • 24
    • 0031830589 scopus 로고    scopus 로고
    • Photon beam skin dose analyses for different clinical setups
    • DOI 10.1118/1.598261
    • S. Kim, C. R. Liu, T. C. Zhu, and J. R. Palta, " Photon beam skin dose analyses for different clinical setups.," Med. Phys. 0094-2405 25 (6), 860-866 (1998). 10.1118/1.598261 (Pubitemid 28285759)
    • (1998) Medical Physics , vol.25 , Issue.6 , pp. 860-866
    • Kim, S.1    Liu, C.R.2    Zhu, T.C.3    Palta, J.R.4
  • 25
    • 85027732547 scopus 로고    scopus 로고
    • Effects of immobilization mask material on surface dose
    • 1526-9914. 10.1120/jacm2023.25317
    • S. W. Hadley, R. Kelly, and K. Lam, " Effects of immobilization mask material on surface dose.," J. Appl. Clin. Med. Phys. 1526-9914 6 (1), 1-7 (2005). 10.1120/jacmp.2023.25317
    • (2005) J. Appl. Clin. Med. Phys. , vol.6 , Issue.1 , pp. 1-7
    • Hadley, S.W.1    Kelly, R.2    Lam, K.3
  • 26
    • 0031954692 scopus 로고    scopus 로고
    • An investigation into the use of carbon fibre for megavoltage radiotherapy applications
    • DOI 10.1088/0031-9155/43/5/025, PII S0031915598868255
    • S. J. P. Meara and K. A. Langmack, " An investigation into the use of carbon fiber for megavoltage radiotherapy applications.," Phys. Med. Biol. 0031-9155 43 (5), 1359-1366 (1998). 10.1088/0031-9155/43/5/025 (Pubitemid 28223578)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.5 , pp. 1359-1366
    • Meara, S.J.P.1    Langmack, K.A.2
  • 27
    • 54949116628 scopus 로고    scopus 로고
    • Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system
    • 0094-2405. 10.1118/1.2982135
    • I. B. Mihaylov, P. Corry, Y. Yan, V. Ratanatharathorn, and E. G. Moros, " Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system.," Med. Phys. 0094-2405 35 (11), 4982-4988 (2008). 10.1118/1.2982135
    • (2008) Med. Phys. , vol.35 , Issue.11 , pp. 4982-4988
    • Mihaylov, I.B.1    Corry, P.2    Yan, Y.3    Ratanatharathorn, V.4    Moros, E.G.5
  • 28
    • 33746874521 scopus 로고    scopus 로고
    • Impact of 6 MV photon attenuation by carbon fiber couch and immobilization devices in IMRT planning and dose delivery
    • 10.4103/0971-6203.26690
    • R. K. Munjal, P. S. Negi, A. G. Babu, S. N. Sinha, A. K. Anand, and T. Kataria, " Impact of 6 MV photon attenuation by carbon fiber couch and immobilization devices in IMRT planning and dose delivery.," J. Med. Phys. 31 (2), 67-71 (2006). 10.4103/0971-6203.26690
    • (2006) J. Med. Phys. , vol.31 , Issue.2 , pp. 67-71
    • Munjal, R.K.1    Negi, P.S.2    Babu, A.G.3    Sinha, S.N.4    Anand, A.K.5    Kataria, T.6
  • 29
    • 0036534905 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in treatment plan evaluation
    • DOI 10.1016/S0360-3016(01)02805-X, PII S036030160102805X
    • M. van Herk, P. Remeijer, and J. V. Lebesque, " Inclusion of geometric uncertainties in treatment plan evaluation.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 52 (5), 1407-1422 (2002). 10.1016/S0360-3016(01) 02805-X (Pubitemid 34296500)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.52 , Issue.5 , pp. 1407-1422
    • Van Herk, M.1    Remeijer, P.2    Lebesque, J.V.3
  • 30
    • 0034039433 scopus 로고    scopus 로고
    • The impact of delivered dose errors on local control of irradiated advanced laryngeal cancer
    • 0028-2685
    • L. Miszczyk, R. Tarnawski, and K. Skadowski, " The impact of delivered dose errors on local control of irradiated advanced laryngeal cancer.," Neoplasma 0028-2685 47 (2), 133-136 (2000).
    • (2000) Neoplasma , vol.47 , Issue.2 , pp. 133-136
    • Miszczyk, L.1    Tarnawski, R.2    Skadowski, K.3
  • 31
    • 30544433073 scopus 로고    scopus 로고
    • Systematic review of the effect of radiation dose on tumor control and morbidity in the treatment of prostate cancer by 3D-CRT
    • 0360-3016. 10.1016/j.ijrob2005.07.974
    • J. van Tol-Geerdink, P. Stalmeier, P. Pasker-de Jong, H. Huizenga, E. van Lin, E. Schimmel, J. Leer, and W. van Daal, " Systematic review of the effect of radiation dose on tumor control and morbidity in the treatment of prostate cancer by 3D-CRT.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 64 (2), 534-543 (2006). 10.1016/j.ijrobp.2005.07.974
    • (2006) Int. J. Radiat. Oncol., Biol., Phys. , vol.64 , Issue.2 , pp. 534-543
    • Van Tol-Geerdink, J.1    Stalmeier, P.2    Pasker-De Jong, P.3    Huizenga, H.4    Van Lin, E.5    Schimmel, E.6    Leer, J.7    Van Daal, W.8
  • 32
    • 0009316397 scopus 로고
    • The measurement of radiation for medical purposes
    • 0370-1328. 10.1088/0959-5309/54/5/302
    • M. V. Mayneord, " The measurement of radiation for medical purposes.," Proc. Phys. Soc. London 0370-1328 54, 405-421 (1942). 10.1088/0959-5309/54/5/302
    • (1942) Proc. Phys. Soc. London , vol.54 , pp. 405-421
    • Mayneord, M.V.1
  • 33
    • 84979133337 scopus 로고
    • The importance of overlapping in irradiation of the scalp: With comments on the tolerance of the skin for soft xrays
    • 0007-0963
    • S. Epstein, " The importance of overlapping in irradiation of the scalp: With comments on the tolerance of the skin for soft xrays.," Brit. Jour. and Dermal., and Syph. 0007-0963 48, 1-11 (1936).
    • (1936) Brit. Jour. and Dermal., and Syph. , vol.48 , pp. 1-11
    • Epstein, S.1
  • 34
    • 0030272267 scopus 로고    scopus 로고
    • High-dose, hyperfractionated, accelerated radiotherapy using a concurrent boost for the treatment of nonsmall cell lung cancer: Unusual toxicity and promising early results
    • DOI 10.1016/S0360-3016(96)00353-7, PII S0360301696003537
    • S. C. King, J. C. Acker, P. S. Kussin, L. B. Marks, K. J. Weeks, and K. A. Leopold, " High-dose, hyperfractionated, accelerated radiotherapy using a concurrent boost for the treatment of nonsmall cell lung cancer: Unusual toxicity and promising early results.," Int. J. Radiat. Oncol., Biol., Phys. 0360-3016 36 (3), 593-599 (1996). 10.1016/S0360-3016(96)00353-7 (Pubitemid 26404302)
    • (1996) International Journal of Radiation Oncology Biology Physics , vol.36 , Issue.3 , pp. 593-599
    • King, S.C.1    Acker, J.C.2    Kussin, P.S.3    Marks, L.B.4    Weeks, K.J.5    Leopold, K.A.6
  • 36
    • 0036787579 scopus 로고    scopus 로고
    • Phase i trial evaluating the concurrent combination of radiotherapy and capecitabine in rectal cancer
    • 0732-183X. 10.1200/JCO.2002.02.049
    • J. Dunst, T. Reese, T. Sutter, H. Zühlke, A. Hinke, K. Kölling-Schlebusch, and S. Frings, " Phase I trial evaluating the concurrent combination of radiotherapy and capecitabine in rectal cancer.," J. Clin. Oncol. 0732-183X 20 (19), 3983-3991 (2002). 10.1200/JCO.2002.02.049
    • (2002) J. Clin. Oncol. , vol.20 , Issue.19 , pp. 3983-3991
    • Dunst, J.1    Reese, T.2    Sutter, T.3    Zühlke, H.4    Hinke, A.5    Kölling- Schlebusch, K.6    Frings, S.7
  • 37
    • 73649105643 scopus 로고
    • X-ray quality and skin reaction
    • 0007-0963. 10.1111/j.1365-2133.1940.tb09891.x
    • G. Schwarz, " X-ray quality and skin reaction.," Br. J. Dermatol. 0007-0963 52 (1), 10-20 (1940). 10.1111/j.1365-2133.1940.tb09891.x
    • (1940) Br. J. Dermatol. , vol.52 , Issue.1 , pp. 10-20
    • Schwarz, G.1
  • 38
    • 73649113280 scopus 로고
    • Studies on x-ray effects: VI effects of the cellular reaction induced by x-rays on cancer grafts
    • 0022-1007. 10.1084/jem.33.3.299
    • J. B. Murphy, R. G. Hussey, W. Nakahara, and E. Sturm, " Studies on x-ray effects: VI effects of the cellular reaction induced by x-rays on cancer grafts.," J. Exp. Med. 0022-1007 33, 299-313 (1921). 10.1084/jem.33.3.299
    • (1921) J. Exp. Med. , vol.33 , pp. 299-313
    • Murphy, J.B.1    Hussey, R.G.2    Nakahara, W.3    Sturm, E.4
  • 39
    • 0029610690 scopus 로고
    • Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray
    • DOI 10.1016/0167-8140(95)01662-7
    • E. J. Adams and A. R. Hounsell, " Changes to dose in the build-up region when using multi-leaf collimators in place of lead blocks supported on an accessory tray.," Radiother. Oncol. 0167-8140 37, 225-229 (1995). 10.1016/0167-8140(95)01662-7 (Pubitemid 26007665)
    • (1995) Radiotherapy and Oncology , vol.37 , Issue.3 , pp. 225-229
    • Adams, E.J.1
  • 40
    • 85047236802 scopus 로고
    • New values for epidermal thickness and their importance
    • 0017-9078. 10.1097/00004032-197301000-00001
    • J. T. Whitton, " New values for epidermal thickness and their importance.," Health Phys. 0017-9078 24, 1-8 (1973). 10.1097/00004032- 197301000-00001
    • (1973) Health Phys. , vol.24 , pp. 1-8
    • Whitton, J.T.1
  • 41
    • 0036146952 scopus 로고    scopus 로고
    • Variations in skin dose associated with linac bed material at 6 MV x-ray energy
    • DOI 10.1088/0031-9155/47/1/404, PII S0031915502259758
    • M. J. Butson, T. Cheung, P. K. N. Yu, and B. Webb, " Variations in skin dose associated with linac bed material at 6 MV x-ray energy.," Phys. Med. Biol. 0031-9155 47, N25-N30 (2002). 10.1088/0031-9155/47/1/404 (Pubitemid 34071359)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.1
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3    Webb, B.4
  • 43
    • 0034749407 scopus 로고    scopus 로고
    • The effect of carbon fiber couch inserts on surface dose with beam size variation
    • DOI 10.1016/S0958-3947(01)00071-1, PII S0958394701000711
    • D. M. Higgins, P. Whitehurst, and A. M. Morgan, " The effect of carbon fiber couch inserts on surface dose with beam size variation.," Med. Dosim. 0739-0211 26 (3), 251-254 (2001). 10.1016/S0958-3947(01)00071-1 (Pubitemid 33026412)
    • (2001) Medical Dosimetry , vol.26 , Issue.3 , pp. 251-254
    • Higgins, D.M.1    Whitehurst, P.2    Morgan, A.M.3
  • 44
    • 0034959129 scopus 로고    scopus 로고
    • Tolerances for the accuracy of photon beam dose calculations of treatment planning systems
    • DOI 10.1016/S0167-8140(01)00377-2, PII S0167814001003772
    • J. Venselaar, H. Welleweerd, and B. Mijnheer, " Tolerances for the accuracy of photon beam calculations of treatment planning systems.," Radiother. Oncol. 0167-8140 60, 191-201 (2001). 10.1016/S0167-8140(01)00377-2 (Pubitemid 32601971)
    • (2001) Radiotherapy and Oncology , vol.60 , Issue.2 , pp. 191-201
    • Venselaar, J.1    Welleweerd, H.2    Mijnheer, B.3
  • 46
    • 23944493580 scopus 로고    scopus 로고
    • Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer
    • DOI 10.1118/1.1992067
    • H. Chung, H. Jin, J. F. Dempsey, C. Liu, J. Palta, T. Suh, and S. Kim, " Evaluation of surface dose and build-up region dose for intensity-modulated radiation therapy in head and neck cancer.," Med. Phys. 0094-2405 32 (8), 2682-2689 (2005). 10.1118/1.1992067 (Pubitemid 41197206)
    • (2005) Medical Physics , vol.32 , Issue.8 , pp. 2682-2689
    • Chung, H.1    Jin, H.2    Dempsey, J.F.3    Liu, C.4    Palta, J.5    Suh, T.-S.6    Kim, S.7
  • 47
    • 0141849098 scopus 로고    scopus 로고
    • Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning
    • DOI 10.1088/0031-9155/48/17/309, PII S0031915503592855
    • M. M. Aspradakis, R. H. Morrison, N. D. Richmond, and A. Steele, " Experimental verification of convolution/superposition photon dose calculations for radiotherapy treatment planning.," Phys. Med. Biol. 0031-9155 48, 2873-2893 (2003). 10.1088/0031-9155/48/17/309 (Pubitemid 37121465)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.17 , pp. 2873-2893
    • Aspradakis, M.M.1    Morrison, R.H.2    Richmond, N.D.3    Steele, A.4
  • 48
    • 7244257425 scopus 로고    scopus 로고
    • Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV
    • DOI 10.1118/1.1786172
    • E. Heath, J. Seuntjens, and D. Sheikh-Bagheri, " Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV.," Med. Phys. 0094-2405 31 (10), 2771-2779 (2004). 10.1118/1.1786172 (Pubitemid 39431002)
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2771-2779
    • Heath, E.1    Seuntjens, J.2    Sheikh-Bagheri, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.