Volumn 34, Issue 3, 2009, Pages 228-232

Skin Dose Impact from Vacuum Immobilization Device and Carbon Fiber Couch in Intensity Modulated Radiation Therapy for Prostate Cancer

Author keywords

Couch; Intensity modulated radiation therapy; Prostate cancer; Skin; Vacuum immobilization device

Indexed keywords

CARBON FIBER;

EID: 67651214053     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2008.10.001     Document Type: Article
Times cited : (20)

References (11)
  • 1
    • 0027963155 scopus 로고
    • Effects of beam modifiers and immobilization devices on the dose in the build-up region
    • Fontenla D.P., Napoli J.J., Hun't M., et al. Effects of beam modifiers and immobilization devices on the dose in the build-up region. Int. J. Radiat. Oncol. Biol. Phys. 30 (1994) 211-219
    • (1994) Int. J. Radiat. Oncol. Biol. Phys. , vol.30 , pp. 211-219
    • Fontenla, D.P.1    Napoli, J.J.2    Hun't, M.3
  • 2
    • 0036644304 scopus 로고    scopus 로고
    • Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma
    • Lee N., Chuang C., Quivey J.M., et al. Skin toxicity due to intensity-modulated radiotherapy for head-and-neck carcinoma. Int. J. Radiat. Oncol. Biol. Phys. 56 (2002) 630-637
    • (2002) Int. J. Radiat. Oncol. Biol. Phys. , vol.56 , pp. 630-637
    • Lee, N.1    Chuang, C.2    Quivey, J.M.3
  • 3
    • 0034749407 scopus 로고    scopus 로고
    • The effect of carbon fiber couch inserts on surface dose with beam size variation
    • Higgins D.M., Whitehurst P., and Morgan A.M. The effect of carbon fiber couch inserts on surface dose with beam size variation. Med. Dosim. 26 (2001) 251-254
    • (2001) Med. Dosim. , vol.26 , pp. 251-254
    • Higgins, D.M.1    Whitehurst, P.2    Morgan, A.M.3
  • 4
    • 0024424112 scopus 로고
    • Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media
    • Ahnesjö A. Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous media. Med. Phys. 16 (1989) 577-592
    • (1989) Med. Phys. , vol.16 , pp. 577-592
    • Ahnesjö, A.1
  • 5
    • 0029375039 scopus 로고
    • A comparison of surface doses for two immobilizing systems
    • Johnson M.W., Griggs M.A., and Sharma S.C. A comparison of surface doses for two immobilizing systems. Med. Dosim. 20 (1995) 191-194
    • (1995) Med. Dosim. , vol.20 , pp. 191-194
    • Johnson, M.W.1    Griggs, M.A.2    Sharma, S.C.3
  • 6
    • 0036012703 scopus 로고    scopus 로고
    • Evaluation of build-up dose from 6 MV X-rays under pelvic and abdominal patient immobilization devices
    • Cheung T., Butson M.J., and Yu P.K.N. Evaluation of build-up dose from 6 MV X-rays under pelvic and abdominal patient immobilization devices. Radia. Meas. 35 (2002) 235-238
    • (2002) Radia. Meas. , vol.35 , pp. 235-238
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.N.3
  • 7
    • 0031954692 scopus 로고    scopus 로고
    • An investigation into the use of carbon fibre for megavoltage radiotherapy applications
    • Meara S.J.P., and Langmack K.A. An investigation into the use of carbon fibre for megavoltage radiotherapy applications. Phys. Med. Biol. 43 (1998) 1359-1366
    • (1998) Phys. Med. Biol. , vol.43 , pp. 1359-1366
    • Meara, S.J.P.1    Langmack, K.A.2
  • 8
    • 0036146952 scopus 로고    scopus 로고
    • Variations in skin dose associated with linac bed material at 6 MV x-ray energy
    • Butson M.J., Cheung T., Yu P.K.N., et al. Variations in skin dose associated with linac bed material at 6 MV x-ray energy. Phys. Med. Biol. 47 (2002) N25-N30
    • (2002) Phys. Med. Biol. , vol.47
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.N.3
  • 9
    • 14644398526 scopus 로고    scopus 로고
    • The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert
    • McCormak S., Diffey J., and Morgan A. The effect of gantry angle on megavoltage photon beam attenuation by a carbon fiber couch insert. Med. Phys. 32 (2005) 483-487
    • (2005) Med. Phys. , vol.32 , pp. 483-487
    • McCormak, S.1    Diffey, J.2    Morgan, A.3
  • 10
    • 0345688217 scopus 로고    scopus 로고
    • Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device
    • Vieira S.C., Kaatee R.S.J.P., Dirkx M.L.P., et al. Two-dimensional measurement of photon beam attenuation by the treatment couch and immobilization devices using an electronic portal imaging device. Med. Phys. 30 (2003) 2981-2987
    • (2003) Med. Phys. , vol.30 , pp. 2981-2987
    • Vieira, S.C.1    Kaatee, R.S.J.P.2    Dirkx, M.L.P.3
  • 11
    • 0023982612 scopus 로고
    • Arc therapy dose perturbation due to the center bar in a clinic 4/100 couch assembly
    • Krithivas G., and Rao S.N. Arc therapy dose perturbation due to the center bar in a clinic 4/100 couch assembly. Med. Dosim. 13 (1988) 15-18
    • (1988) Med. Dosim. , vol.13 , pp. 15-18
    • Krithivas, G.1    Rao, S.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.