메뉴 건너뛰기




Volumn 2012, Issue , 2012, Pages

Fibre optic readout of microcantilever arrays for fast microorganism growth detection

Author keywords

[No Author keywords available]

Indexed keywords


EID: 81555221796     PISSN: 1687725X     EISSN: 16877268     Source Type: Journal    
DOI: 10.1155/2012/405281     Document Type: Article
Times cited : (11)

References (18)
  • 5
    • 2342620796 scopus 로고    scopus 로고
    • An Anti E. Coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E. coli)
    • Zhang J., Ji H. F., An Anti E. Coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E. coli) Analytical Sciences 2004 20 4 585 587
    • (2004) Analytical Sciences , vol.20 , Issue.4 , pp. 585-587
    • Zhang, J.1    Ji, H.F.2
  • 6
    • 33846876588 scopus 로고    scopus 로고
    • Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications
    • DOI 10.1038/nnano.2006.208
    • Li M., Tang H. X., Roukes M. L., Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications Nature Nanotechnology 2007 2 2 114 120 (Pubitemid 46226371)
    • (2007) Nature Nanotechnology , vol.2 , Issue.2 , pp. 114-120
    • Li, M.1    Tang, H.X.2    Roukes, M.L.3
  • 8
    • 1842788500 scopus 로고    scopus 로고
    • Single virus particle mass detection using microresonators with nanoscale thickness
    • Gupta A., Akin D., Bashir R., Single virus particle mass detection using microresonators with nanoscale thickness Applied Physics Letters 2004 84 11 1976 1978
    • (2004) Applied Physics Letters , vol.84 , Issue.11 , pp. 1976-1978
    • Gupta, A.1    Akin, D.2    Bashir, R.3
  • 11
    • 18444405555 scopus 로고    scopus 로고
    • Rapid biosensor for detection of antibiotic-selective growth of Escherichia coli
    • DOI 10.1128/AEM.71.5.2626-2631.2005
    • Gfeller K. Y., Nugaeva N., Hegner M., Rapid biosensor for detection of antibiotic-selective growth of Escherichia coli Applied and Environmental Microbiology 2005 71 5 2626 2631 (Pubitemid 40647009)
    • (2005) Applied and Environmental Microbiology , vol.71 , Issue.5 , pp. 2626-2631
    • Gfeller, K.Y.1    Nugaeva, N.2    Hegner, M.3
  • 12
    • 23044484764 scopus 로고    scopus 로고
    • Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli
    • DOI 10.1016/j.bios.2004.11.018, PII S0956566304005688
    • Gfeller K. Y., Nugaeva N., Hegner M., Micromechanical oscillators as rapid biosensor for the detection of active growth of Escherichia coli Biosensors and Bioelectronics 2005 21 3 528 533 (Pubitemid 41074943)
    • (2005) Biosensors and Bioelectronics , vol.21 , Issue.3 , pp. 528-533
    • Gfeller, K.Y.1    Nugaeva, N.2    Hegner, M.3
  • 13
    • 33947399825 scopus 로고    scopus 로고
    • An antibody-sensitized microfabricated cantilever for the growth detection of Aspergillus niger spores
    • DOI 10.1017/S1431927607070067, PII S1431927607070067
    • Nugaeva N., Gfeller K. Y., Backmann N., Dggelin M., Lang H. P., Gntherodt H. J., Hegner M., An antibody-sensitized microfabricated cantilever for the growth detection of Aspergillus niger spores Microscopy and Microanalysis 2007 13 1 13 17 (Pubitemid 46457528)
    • (2007) Microscopy and Microanalysis , vol.13 , Issue.1 , pp. 13-17
    • Nugaeva, N.1    Gfeller, K.Y.2    Backmann, N.3    Duggelin, M.4    Lang, H.P.5    Guntherodt, H.-J.6    Hegner, M.7
  • 14
    • 27444442435 scopus 로고    scopus 로고
    • Micromechanical cantilever array sensors for selective fungal immobilization and fast growth detection
    • DOI 10.1016/j.bios.2005.02.004, PII S0956566305000400
    • Nugaeva N., Gfeller K. Y., Backmann N., Lang H. P., Dggelin M., Hegner M., Micromechanical cantilever array sensors for selective fungal immobilization and fast growth detection Biosensors and Bioelectronics 2005 21 6 849 856 (Pubitemid 41532267)
    • (2005) Biosensors and Bioelectronics , vol.21 , Issue.6 , pp. 849-856
    • Nugaeva, N.1    Gfeller, K.Y.2    Backmann, N.3    Lang, H.P.4    Duggelin, M.5    Hegner, M.6
  • 15
    • 36549096102 scopus 로고
    • Novel optical approach to atomic force microscopy
    • Meyer G., Amer N. M., Novel optical approach to atomic force microscopy Applied Physics Letters 1988 53 12 1045 1047
    • (1988) Applied Physics Letters , vol.53 , Issue.12 , pp. 1045-1047
    • Meyer, G.1    Amer, N.M.2
  • 16
    • 4344675565 scopus 로고    scopus 로고
    • Rapid functionalization of cantilever array sensors by inkjet printing
    • Bietsch A., Zhang J., Hegner M., Lang H. P., Gerber C., Rapid functionalization of cantilever array sensors by inkjet printing Nanotechnology 2004 15 8 873 880
    • (2004) Nanotechnology , vol.15 , Issue.8 , pp. 873-880
    • Bietsch, A.1    Zhang, J.2    Hegner, M.3    Lang, H.P.4    Gerber, C.5
  • 17
    • 33751556466 scopus 로고    scopus 로고
    • Effect of the adsorbate stiffness on the resonance response of microcantilever sensors
    • Tamayo J., Ramos D., Mertens J., Calleja M., Effect of the adsorbate stiffness on the resonance response of microcantilever sensors Applied Physics Letters 2006 89 22
    • (2006) Applied Physics Letters , vol.89 , Issue.22
    • Tamayo, J.1    Ramos, D.2    Mertens, J.3    Calleja, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.