메뉴 건너뛰기




Volumn 213, Issue 1, 2011, Pages 14-21

Band-selective chemical exchange saturation transfer imaging with hyperpolarized xenon-based molecular sensors

Author keywords

Chemical exchange saturation transfer; Contrast agent; Hyperpolarization; MRI; Xenon

Indexed keywords

CHEMICAL EXCHANGE; CHEMICAL EXCHANGE SATURATION TRANSFER; CONTINUOUS WAVE; CONTRAST AGENT; DETECTION SENSITIVITY; HYPERPOLARIZATION; HYPERPOLARIZED; IMAGING EXPERIMENTS; LIMITED BANDWIDTH; MOLECULAR IMAGING; MOLECULAR SENSORS; MULTI-SPECTRAL; MULTIPLE PULSE; RF-POWER; SATURATION FIELDS; SATURATION TRANSFER;

EID: 80055090928     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2011.06.027     Document Type: Article
Times cited : (25)

References (29)
  • 1
    • 70349918272 scopus 로고    scopus 로고
    • Ultrasensitive detection of bacteria using core-shell nanoparticles and a NMR-filter system
    • H. Lee, T. Yoon, and R. Weissleder Ultrasensitive detection of bacteria using core-shell nanoparticles and a NMR-filter system Angew. Chem. Int. Ed. 48 2009 5657 5660
    • (2009) Angew. Chem. Int. Ed. , vol.48 , pp. 5657-5660
    • Lee, H.1    Yoon, T.2    Weissleder, R.3
  • 2
    • 33744523144 scopus 로고    scopus 로고
    • Paramagnetic lanthanide complexes as PARACEST agents for medical imaging
    • DOI 10.1039/b509907m
    • M. Woods, D. Woessner, and A. Sherry Paramagnetic lanthanide complexes as PARACEST agents for medical imaging Chem. Soc. Rev. 35 2006 500 511 (Pubitemid 43815284)
    • (2006) Chemical Society Reviews , vol.35 , Issue.6 , pp. 500-511
    • Woods, M.1    Woessner, D.E.2    Sherry, A.D.3
  • 7
    • 4544309954 scopus 로고    scopus 로고
    • Influence of the electrical resistivity of a ferromagnetic thin film on its permeability measurement performed with a permeameter
    • P.M. Jacquart, and L. Roux Influence of the electrical resistivity of a ferromagnetic thin film on its permeability measurement performed with a permeameter J. Magn. Magn. Mater. 281 2004 82 91
    • (2004) J. Magn. Magn. Mater. , vol.281 , pp. 82-91
    • Jacquart, P.M.1    Roux, L.2
  • 8
    • 0032869216 scopus 로고    scopus 로고
    • Method for improved multiband excitation profiles using the Shinnar-Le Roux transform
    • DOI 10.1002/(SICI)1522-2594(199909)42:3<577::AID-MRM21>3.0.CO;2-E
    • C.H. Cunningham, and M.L. Wood Method for improved multiband excitation profiles using the Shinnar-Le Roux transform Magn. Reson. Med. 42 1999 577 584 (Pubitemid 29416220)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.3 , pp. 577-584
    • Cunningham, C.H.1    Wood, M.L.2
  • 10
    • 34249939653 scopus 로고    scopus 로고
    • General parameter relations for the Shinnar-Le Roux pulse design algorithm
    • DOI 10.1016/j.jmr.2007.03.010, PII S1090780707000821
    • K.J. Lee General parameter relations for the Shinnar-Le Roux pulse design algorithm J. Magn. Reson. 186 2007 252 258 (Pubitemid 46880437)
    • (2007) Journal of Magnetic Resonance , vol.186 , Issue.2 , pp. 252-258
    • Lee, K.J.1
  • 11
    • 0033822157 scopus 로고    scopus 로고
    • Probing lung physiology with xenon polarization transfer contrast (XTC)
    • K. Ruppert, J. Brookeman, K. Hagspiel, and J. Mugler III Probing lung physiology with xenon polarization transfer contrast (XTC) Magn. Reson. Med. 44 2000 349 357
    • (2000) Magn. Reson. Med. , vol.44 , pp. 349-357
    • Ruppert, K.1    Brookeman, J.2    Hagspiel, K.3    Mugler Iii, J.4
  • 12
    • 33750319936 scopus 로고    scopus 로고
    • Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor
    • DOI 10.1126/science.1131847
    • L. Schröder, T.J. Lowery, C. Hilty, D.E. Wemmer, and A. Pines Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor Science 314 2006 446 449 (Pubitemid 44628961)
    • (2006) Science , vol.314 , Issue.5798 , pp. 446-449
    • Schroder, L.1    Lowery, T.J.2    Hilty, C.3    Wemmer, D.E.4    Pines, A.5
  • 13
    • 33646511088 scopus 로고    scopus 로고
    • Water soluble cryptophanes showing unprecedented affinity for xenon: Candidates as NMR-based biosensors
    • G. Huber, T. Brotin, L. Dubois, H. Desvaux, J.-P. Dutasta, and P. Berthault Water soluble cryptophanes showing unprecedented affinity for xenon: candidates as NMR-based biosensors J. Am. Chem. Soc. 128 2006 6239 6246
    • (2006) J. Am. Chem. Soc. , vol.128 , pp. 6239-6246
    • Huber, G.1    Brotin, T.2    Dubois, L.3    Desvaux, H.4    Dutasta, J.-P.5    Berthault, P.6
  • 15
    • 0031480383 scopus 로고    scopus 로고
    • Spin-exchange optical pumping of noble-gas nuclei
    • T. Walker, and W. Happer Spin-exchange optical pumping of noble-gas nuclei Rev. Mod. Phys. 69 1997 629 642
    • (1997) Rev. Mod. Phys. , vol.69 , pp. 629-642
    • Walker, T.1    Happer, W.2
  • 17
    • 37049095454 scopus 로고
    • Synthesis of a (D 3)-Bis (cyclotriveratrylenyl) macrocage by stereospecific replication of a (C 3)-subunit
    • J. Gabard, and A. Collet Synthesis of a (D 3)-Bis (cyclotriveratrylenyl) macrocage by stereospecific replication of a (C 3)-subunit J. Chem. Soc. Chem. Commun. 1981 1981 1137 1139
    • (1981) J. Chem. Soc. Chem. Commun. , vol.1981 , pp. 1137-1139
    • Gabard, J.1    Collet, A.2
  • 18
    • 64249132406 scopus 로고    scopus 로고
    • Cryptophanes and their complexes - Present and future
    • T. Brotin, and J. Dutasta Cryptophanes and their complexes - present and future Chem. Rev. 109 2009 88 130
    • (2009) Chem. Rev. , vol.109 , pp. 88-130
    • Brotin, T.1    Dutasta, J.2
  • 20
    • 70349900690 scopus 로고    scopus 로고
    • Single-scan 2D Hadamard NMR spectroscopy
    • A. Tal, B. Shapira, and L. Frydman Single-scan 2D Hadamard NMR spectroscopy Angew. Chem. Int. Ed. 48 2009 2732 2736
    • (2009) Angew. Chem. Int. Ed. , vol.48 , pp. 2732-2736
    • Tal, A.1    Shapira, B.2    Frydman, L.3
  • 21
    • 0023574349 scopus 로고
    • Radiofrequency penetration and absorption in the human body: Limitations to high-field whole-body nuclear magnetic resonance imaging
    • DOI 10.1118/1.595995
    • P. Röschmann Radiofrequency penetration and absorption in the human body: limitations to high-field whole-body nuclear magnetic resonance imaging Med. Phys. 14 1987 922 931 (Pubitemid 18025944)
    • (1987) Medical Physics , vol.14 , Issue.6 , pp. 922-931
    • Roschmann, P.1
  • 24
    • 0029270246 scopus 로고
    • Short selective pulses for biochemical applications
    • E. Kupce, J. Boyd, and I. Campbell Short selective pulses for biochemical applications J. Magn. Reson. Ser. B 106 1995 300 303
    • (1995) J. Magn. Reson. Ser. B , vol.106 , pp. 300-303
    • Kupce, E.1    Boyd, J.2    Campbell, I.3
  • 25
    • 0024418829 scopus 로고
    • The use of finite impulse response filters in pulse design
    • M. Shinnar, L. Bolinger, and J.S. Leigh The use of finite impulse-response filters in pulse design Magn. Reson. Med. 12 1989 81 87 (Pubitemid 19240751)
    • (1989) Magnetic Resonance in Medicine , vol.12 , Issue.1 , pp. 81-87
    • Shinnar, M.1    Bolinger, L.2    Leigh, J.S.3
  • 27
    • 46349087419 scopus 로고    scopus 로고
    • Temperature response of Xe-129 depolarization transfer and its application for ultrasensitive NMR detection
    • L. Schröder, T. Meldrum, M. Smith, T.J. Lowery, D.E. Wemmer, and A. Pines Temperature response of Xe-129 depolarization transfer and its application for ultrasensitive NMR detection Phys. Rev. Lett. 100 2008 257603(4)
    • (2008) Phys. Rev. Lett. , vol.100 , pp. 2576034
    • Schröder, L.1    Meldrum, T.2    Smith, M.3    Lowery, T.J.4    Wemmer, D.E.5    Pines, A.6
  • 29


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.