메뉴 건너뛰기




Volumn , Issue , 2011, Pages 4-10

Human++: Key challenges and trade-offs in embedded system design for personal health care

Author keywords

Battery life time optimization; Body area networks; Embedded system design; Personal health care; Sensor network; Sensor nodes; Ultra low power design

Indexed keywords

BATTERY LIFE TIME; BODY AREA NETWORK; CIRCUIT TECHNIQUES; COMPUTER INTERACTION; HOME ENVIRONMENT; IMPLANTABLE SENSORS; LOWER COST; MANY BODY; NEW COMPONENTS; ORDERS OF MAGNITUDE; PERSONAL HEALTH CARE; PHYSIOLOGICAL SIGNALS; QUALITY OF LIFE; RESEARCH AND DEVELOPMENT; SMALL FORM FACTORS; SYSTEM OPTIMIZATIONS; ULTRA-LOW POWER DESIGN; ULTRA-THIN;

EID: 80054974594     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/DSD.2011.115     Document Type: Conference Paper
Times cited : (4)

References (32)
  • 1
    • 80054970178 scopus 로고    scopus 로고
    • Continua Health Alliance: www.continuaalliance.org
  • 4
    • 80054968869 scopus 로고    scopus 로고
    • Internet
    • Internet: http://en.wikipedia.org/wiki/List-of-battery-sizes
  • 8
    • 0035273830 scopus 로고    scopus 로고
    • A low-power CMOS super-regenerative receiver at 1 GHz
    • DOI 10.1109/4.910483, PII S0018920001014810
    • A. Vouilloz, M. Declercq, and C. Dehollain, "A low-power CMOS super-regenerative receiver at 1 GHz," IEEE J. Solid-State Circuits, vol.36, no. 3, pp. 440-451, Mar. 2001. (Pubitemid 32302985)
    • (2001) IEEE Journal of Solid-State Circuits , vol.36 , Issue.3 , pp. 440-451
    • Vouilloz, A.1    Declercq, M.2    Dehollain, C.3
  • 9
    • 34548278312 scopus 로고    scopus 로고
    • A fully integrated auto-calibrated super-regenerative receiver in 0.13μm CMOS
    • J. Y. Chen et al., "A fully integrated auto-calibrated super-regenerative receiver in 0.13μm CMOS," IEEE J. Solid-State Circuits, vol. 42, pp. 1976-1985, 2007.
    • (2007) IEEE J. Solid-state Circuits , vol.42 , pp. 1976-1985
    • Chen, J.Y.1
  • 10
    • 51949105602 scopus 로고    scopus 로고
    • A 5GHz fully integrated super-regenerative receiver with on-chip slot antenna in 0.13μm CMOS
    • D. Shi, N. Behdad, J.Y. Chen and M. P. Flynn, "A 5GHz fully integrated super-regenerative receiver with on-chip slot antenna in 0.13μm CMOS", IEEE Symposium on VLSI Circuits, pp. 34 - 35, 2008.
    • (2008) IEEE Symposium on VLSI Circuits , pp. 34-35
    • Shi, D.1    Behdad, N.2    Chen, J.Y.3    Flynn, M.P.4
  • 11
    • 33746905542 scopus 로고    scopus 로고
    • An ultra-low-power injection locked transmitter for wireless sensor networks
    • DOI 10.1109/JSSC.2006.877254, 1661750
    • Y.H. Chee et al., "An Ultra-Low-Power Injection Locked Transmitter for Wireless Sensor Networks," IEEE J. Solid-State Circuits, vol. 41, no.8, pp. 1740 - 1748, Aug. 2006. (Pubitemid 44192099)
    • (2006) IEEE Journal of Solid-State Circuits , vol.41 , Issue.8 , pp. 1740-1748
    • Chee, Y.H.1    Niknejad, A.M.2    Rabaey, J.M.3
  • 12
    • 67649948985 scopus 로고    scopus 로고
    • A 52 pj/bit OOK transmitter with adaptable data rate
    • Nov
    • M.K. Raja, et al., "A 52 pj/bit OOK transmitter with adaptable data rate," ASSCC 2008, pp.341-344, Nov 2008.
    • (2008) ASSCC 2008 , pp. 341-344
    • Raja, M.K.1
  • 13
    • 34247395005 scopus 로고    scopus 로고
    • An energy-efficient OOK transceiver for wireless sensor networks
    • May
    • D.C. Daly et al., "An Energy-Efficient OOK Transceiver for Wireless Sensor Networks" IEEE J. Solid-State Circuits, vol. 42, no.5, pp. 1003 - 1011, May 2007.
    • (2007) IEEE J. Solid-state Circuits , vol.42 , Issue.5 , pp. 1003-1011
    • Daly, D.C.1
  • 14
    • 79851472908 scopus 로고    scopus 로고
    • Nordic Semiconductor "The Wireless Quarter", 2007, www.nordicsemi.no/files/Product/relevantdocuments/NSWQ307eR.pdf.
    • (2007) The Wireless Quarter
  • 15
    • 51949119560 scopus 로고    scopus 로고
    • A 350μW CMOS MSK transmitterand 400μW OOK super-regenerative receiver for medical implant communications
    • Honolulu, HI, June
    • J. L. Bohorquez, J. L. Dawson, and A. P. Chandrakasan, "A 350μW CMOS MSK transmitterand 400μW OOK super-regenerative receiver for Medical Implant Communications," in Proc. IEEE Symp. on VLSI Circuits, Honolulu, HI, June 2008, pp. 32-33.
    • (2008) Proc. IEEE Symp. on VLSI Circuits , pp. 32-33
    • Bohorquez, J.L.1    Dawson, J.L.2    Chandrakasan, A.P.3
  • 17
    • 79952904380 scopus 로고    scopus 로고
    • Human++: Wireless autonomous sensor technology for body area networks
    • V. Pop, et al, "Human++: wireless autonomous sensor technology for body area networks", ASP-DAC 2011.
    • ASP-DAC 2011
    • Pop, V.1
  • 18
    • 49549093629 scopus 로고    scopus 로고
    • A 65nm sub-vt microcontroller with integrated SRAM and switched-capacitor DC-DC converter
    • J. Kwong, et al., "A 65nm Sub-Vt Microcontroller with Integrated SRAM and Switched-Capacitor DC-DC Converter", ISSCC 2008.
    • ISSCC 2008
    • Kwong, J.1
  • 19
    • 51949107763 scopus 로고    scopus 로고
    • Phoenix processor: A 30pW platform for sensor applications
    • M. Seok, et al., "Phoenix Processor: A 30pW Platform for Sensor Applications", Symp. On VLSI Circuits 2008.
    • Symp. on VLSI Circuits 2008
    • Seok, M.1
  • 20
  • 21
    • 77958019331 scopus 로고    scopus 로고
    • Microwatt embedded processor platform for medical system-on-chip applications
    • S.R. Sridhara, et al., "Microwatt Embedded Processor Platform for Medical System-on-Chip Applications", Symp. On VLSI 2010.
    • Symp. on VLSI 2010
    • Sridhara, S.R.1
  • 22
    • 77952188483 scopus 로고    scopus 로고
    • Millimeter-S cale nearly perpetual sensor system with stacked battery and solar cells
    • G. Chen, et al., "Millimeter-S cale Nearly Perpetual Sensor System with Stacked Battery and Solar Cells", ISSCC 2010.
    • ISSCC 2010
    • Chen, G.1
  • 23
    • 80054976886 scopus 로고    scopus 로고
    • (accessed on May 23, 2011)
    • http://www.coolflux.com/new-coollux-bsp (accessed on May 23, 2011)
  • 24
    • 79955725331 scopus 로고    scopus 로고
    • A voltage-scalable biomedical signal processor running ECG using 13pJ/cycle at 1MHz and 0.4V
    • M. Ashouei, et al, "A Voltage-Scalable Biomedical Signal Processor Running ECG Using 13pJ/cycle at 1MHz and 0.4V", ISSCC 2011.
    • ISSCC 2011
    • Ashouei, M.1
  • 25
    • 79955711112 scopus 로고    scopus 로고
    • Game-changing opportunities for wireless personal health care and lifestyle
    • Jo De Boeck, "Game-Changing Opportunities for Wireless Personal Health care and Lifestyle", ISSCC 2011.
    • ISSCC 2011
    • De Boeck, J.1
  • 26
    • 34247338024 scopus 로고    scopus 로고
    • A 60 μW 60nV/Hz readout front-end for portable biopotential acquisition systems
    • Feb.
    • R. F. Yazicioglu, P. Merken, R. Puers, and C. Van Hoof, "A 60 μW 60nV/Hz Readout Front-End for Portable Biopotential Acquisition Systems," IEEE ISSCC, vol. 1, pp. 56-57, Feb. 2006.
    • (2006) IEEE ISSCC , vol.1 , pp. 56-57
    • Yazicioglu, R.F.1    Merken, P.2    Puers, R.3    Van Hoof, C.4
  • 27
    • 62349113898 scopus 로고    scopus 로고
    • Integrated circuit amplifiers for multi-electrode intracortical recording
    • Jan.
    • T. Jochum, T. Denison, P. Wolf, "Integrated circuit amplifiers for multi-electrode intracortical recording" J. Neural Eng., vol. 6, Jan. 2009.
    • (2009) J. Neural Eng. , vol.6
    • Jochum, T.1    Denison, T.2    Wolf, P.3
  • 28
    • 77952129015 scopus 로고    scopus 로고
    • A 30μW analog signal processor ASIC for biomedical signal monitoring
    • Feb.
    • R. F. Yazicioglu, S. Kim, T. Torfs, P. Merken, and C. Van Hoof, "A 30μW Analog Signal Processor ASIC for Biomedical Signal Monitoring," IEEE ISSCC, pp.124-125, Feb. 2010.
    • (2010) IEEE ISSCC , pp. 124-125
    • Yazicioglu, R.F.1    Kim, S.2    Torfs, T.3    Merken, P.4    Van Hoof, C.5
  • 29
    • 77958021201 scopus 로고    scopus 로고
    • A 2.4 μA continuous-time electrode-skin impedance measurement circuit for motion artifact monitoring in ECG acquisition systems
    • June
    • S. Kim, R. F. Yazicioglu, T. Torfs, B. Dilpreet, J. Penders, and C. Van Hoof, "A 2.4 μA continuous-time electrode-skin impedance measurement circuit for motion artifact monitoring in ECG acquisition systems," IEEE Symposium on VLSI Technology, pp. 219-220, June 2010.
    • (2010) IEEE Symposium on VLSI Technology , pp. 219-220
    • Kim, S.1    Yazicioglu, R.F.2    Torfs, T.3    Dilpreet, B.4    Penders, J.5    Van Hoof, C.6
  • 30
    • 80054981091 scopus 로고    scopus 로고
    • Texas instruments, MSP430
    • Texas instruments, MSP430
  • 32
    • 85008063690 scopus 로고    scopus 로고
    • The design of integrated circuits to observe brain activity
    • July
    • R.R. Harrison, "The design of integrated circuits to observe brain activity," Proceedings of the IEEE 96: 1203-1216, July 2008.
    • (2008) Proceedings of the IEEE , vol.96 , pp. 1203-1216
    • Harrison, R.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.