메뉴 건너뛰기




Volumn 261, Issue 2, 2011, Pages 467-476

Abdominal dynamic CT in patients with renal dysfunction: Contrast agent dose reduction with low tube voltage and high tube current-time product settings at 256-detector row CT

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM; IOHEXOL; IOMEPROL; IOPAMIDOL;

EID: 80054778406     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.11110021     Document Type: Article
Times cited : (103)

References (44)
  • 2
    • 33746919048 scopus 로고    scopus 로고
    • Contrast-induced nephrotoxicity: Clinical landscape
    • Katzberg RW, Haller C. Contrast-induced nephrotoxicity: clinical landscape. Kidney Int Suppl 2006; (100):S3-S7.
    • (2006) Kidney Int Suppl , Issue.100
    • Katzberg, R.W.1    Haller, C.2
  • 3
  • 5
    • 0030661687 scopus 로고    scopus 로고
    • Acute renal failure after coronary intervention: Incidence, risk factors, and relationship to mortality
    • DOI 10.1016/S0002-9343(97)00150-2, PII S0002934397001502
    • McCullough PA, Wolyn R, Rocher LL, Levin RN, O'Neill WW. Acute renal failure after coronary intervention: incidence, risk factors, and relationship to mortality. Am J Med 1997;103(5):368-375. (Pubitemid 27506242)
    • (1997) American Journal of Medicine , vol.103 , Issue.5 , pp. 368-375
    • McCullough, P.A.1    Wolyn, R.2    Rocher, L.L.3    Levin, R.N.4    O'Neill, W.W.5
  • 6
    • 0033133411 scopus 로고    scopus 로고
    • ACC/AHA guidelines for coronary angiography: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography) - Developed in collaboration with the Society for Cardiac Angiography and Interventions
    • Scanlon PJ, Faxon DP, Audet AM, et al. ACC/AHA guidelines for coronary angiography: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography) - developed in collaboration with the Society for Cardiac Angiography and Interventions. J Am Coll Cardiol 1999;33(6):1756-1824.
    • (1999) J Am Coll Cardiol , vol.33 , Issue.6 , pp. 1756-1824
    • Scanlon, P.J.1    Faxon, D.P.2    Audet, A.M.3
  • 7
    • 0034332861 scopus 로고    scopus 로고
    • The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency
    • Gruberg L, Mintz GS, Mehran R, et al. The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency. J Am Coll Cardiol 2000;36(5):1542-1548.
    • (2000) J Am Coll Cardiol , vol.36 , Issue.5 , pp. 1542-1548
    • Gruberg, L.1    Mintz, G.S.2    Mehran, R.3
  • 8
    • 0033730930 scopus 로고    scopus 로고
    • Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow
    • Wintermark M, Maeder P, Verdun FR, et al. Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. AJNR Am J Neuroradiol 2000;21(10):1881-1884.
    • (2000) AJNR Am J Neuroradiol , vol.21 , Issue.10 , pp. 1881-1884
    • Wintermark, M.1    Maeder, P.2    Verdun, F.R.3
  • 9
    • 1642389455 scopus 로고    scopus 로고
    • Low-Kilovoltage Multi-Detector Row Chest CT in Adults: Feasibility and Effect on Image Quality and Iodine Dose
    • DOI 10.1148/radiol.2311030191
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF. Low-kilovoltage multidetector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 2004;231(1):169-174. (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5
  • 12
    • 33847196400 scopus 로고    scopus 로고
    • Circle of Willis at CT angiography: Dose reduction and image quality - Reducing tube voltage and increasing tube current settings
    • Waaijer A, Prokop M, Velthuis BK, Bakker CJ, de Kort GA, van Leeuwen MS. Circle of Willis at CT angiography: dose reduction and image quality - reducing tube voltage and increasing tube current settings. Radiology 2007;242(3):832-839.
    • (2007) Radiology , vol.242 , Issue.3 , pp. 832-839
    • Waaijer, A.1    Prokop, M.2    Velthuis, B.K.3    Bakker, C.J.4    De Kort, G.A.5    Van Leeuwen, M.S.6
  • 13
    • 77955626797 scopus 로고    scopus 로고
    • Contrast opacification using a reduced volume of iodinated contrast material and low peak kilovoltage in pulmonary CT angiography: Objective and subjective evaluation
    • Hunsaker AR, Oliva IB, Cai T, et al. Contrast opacification using a reduced volume of iodinated contrast material and low peak kilovoltage in pulmonary CT angiography: objective and subjective evaluation. AJR Am J Roentgenol 2010;195(2):W118-W124.
    • (2010) AJR Am J Roentgenol , vol.195 , Issue.2
    • Hunsaker, A.R.1    Oliva, I.B.2    Cai, T.3
  • 14
    • 33750299544 scopus 로고    scopus 로고
    • Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography
    • Nakayama Y, Awai K, Funama Y, et al. Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography. AJR Am J Roentgenol 2006;187(5):W490-W497.
    • (2006) AJR Am J Roentgenol , vol.187 , Issue.5
    • Nakayama, Y.1    Awai, K.2    Funama, Y.3
  • 15
    • 77957866866 scopus 로고    scopus 로고
    • Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease
    • Utsunomiya D, Oda S, Funama Y, et al. Comparison of standard- and low-tube voltage MDCT angiography in patients with peripheral arterial disease. Eur Radiol 2010;20(11):2758-2765.
    • (2010) Eur Radiol , vol.20 , Issue.11 , pp. 2758-2765
    • Utsunomiya, D.1    Oda, S.2    Funama, Y.3
  • 17
    • 67049172574 scopus 로고    scopus 로고
    • Hypervascular liver tumors: Low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection - Initial clinical experience
    • Marin D, Nelson RC, Samei E, et al. Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection - initial clinical experience. Radiology 2009;251(3):771-779.
    • (2009) Radiology , vol.251 , Issue.3 , pp. 771-779
    • Marin, D.1    Nelson, R.C.2    Samei, E.3
  • 20
    • 65549111017 scopus 로고    scopus 로고
    • Revised equations for estimated GFR from serum creatinine in Japan
    • Matsuo S, Imai E, Horio M, et al. Revised equations for estimated GFR from serum creatinine in Japan. Am J Kidney Dis 2009;53(6):982-992.
    • (2009) Am J Kidney Dis , vol.53 , Issue.6 , pp. 982-992
    • Matsuo, S.1    Imai, E.2    Horio, M.3
  • 21
    • 3042544795 scopus 로고    scopus 로고
    • Optimizing abdominal CT dose and image quality with respect to x-ray tube voltage
    • Yaffe MJ, Flynn MJ, eds. Bellingham, Wash : International Society for Optical Engineering
    • Huda W, Ogden KM. Optimizing abdominal CT dose and image quality with respect to x-ray tube voltage. In: Yaffe MJ, Flynn MJ, eds. Proceedings of SPIE: medical imaging 2004 - physics of medical imaging. Vol 5368. Bellingham, Wash : International Society for Optical Engineering, 2004;499-507.
    • (2004) Proceedings of SPIE: Medical Imaging 2004 - Physics of Medical Imaging , vol.5368 , pp. 499-507
    • Huda, W.1    Ogden, K.M.2
  • 23
    • 77950604342 scopus 로고    scopus 로고
    • Estimating effective dose for CT using dose-length product compared with using organ doses: Consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning
    • Christner JA, Kofler JM, McCollough CH. Estimating effective dose for CT using dose-length product compared with using organ doses: consequences of adopting International Commission on Radiological Protection publication 103 or dual-energy scanning. AJR Am J Roentgenol 2010;194(4):881-889.
    • (2010) AJR Am J Roentgenol , vol.194 , Issue.4 , pp. 881-889
    • Christner, J.A.1    Kofler, J.M.2    McCollough, C.H.3
  • 24
    • 0029988097 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT
    • Baron RL, Oliver JH 3rd, Dodd GD 3rd, Nalesnik M, Holbert BL, Carr B. Hepatocellular carcinoma: evaluation with biphasic, contrast-enhanced, helical CT. Radiology 1996;199(2):505-511. (Pubitemid 26122003)
    • (1996) Radiology , vol.199 , Issue.2 , pp. 505-511
    • Baron, R.L.1    Oliver III, J.H.2    Dodd III, G.D.3    Nalesnik, M.4    Holbert, B.L.5    Carr, B.6
  • 25
    • 1842411962 scopus 로고    scopus 로고
    • Nodular hepatocellular carcinomas: Detection with arterial-, portal-, and delayed-phase images at spiral CT
    • Hwang GJ, Kim MJ, Yoo HS, Lee JT. Nodular hepatocellular carcinomas: with tion with arterial-, portal-, and delayed-phase images at spiral CT. Radiology 1997;202(2):383-388. (Pubitemid 27051731)
    • (1997) Radiology , vol.202 , Issue.2 , pp. 383-388
    • Hwang, G.J.1    Kim, M.-J.2    Yoo, H.S.3    Lee, J.T.4
  • 27
    • 33646112899 scopus 로고    scopus 로고
    • Imaging liver metastases: Review and update
    • Kanematsu M, Kondo H, Goshima S, et al. Imaging liver metastases: review and update. Eur J Radiol 2006;58(2):217-228.
    • (2006) Eur J Radiol , vol.58 , Issue.2 , pp. 217-228
    • Kanematsu, M.1    Kondo, H.2    Goshima, S.3
  • 28
    • 0033848915 scopus 로고    scopus 로고
    • Abdominal helical CT: Evaluation of optimal doses of intravenous contrast material - A prospective randomized study
    • Yamashita Y, Komohara Y, Takahashi M, et al. Abdominal helical CT: evaluation of optimal doses of intravenous contrast material - a prospective randomized study. Radiology 2000;216(3):718-723. (Pubitemid 30660843)
    • (2000) Radiology , vol.216 , Issue.3 , pp. 718-723
    • Yamashita, Y.1    Komohara, Y.2    Takahashi, M.3    Uchida, M.4    Hayabuchi, N.5    Shimizu, T.6    Narabayashi, I.7
  • 30
    • 21244473081 scopus 로고    scopus 로고
    • A framework for optimising the radiographic technique in digital X-ray imaging
    • DOI 10.1093/rpd/nch562
    • Samei E, Dobbins JT 3rd, Lo JY, Tornai MP. A framework for optimising the radiographic technique in digital x-ray imaging. Radiat Prot Dosimetry 2005;114(1-3):220-229. (Pubitemid 40883685)
    • (2005) Radiation Protection Dosimetry , vol.114 , Issue.1-3 , pp. 220-229
    • Samei, E.1    Dobbins III, J.T.2    Lo, J.Y.3    Tornai, M.P.4
  • 31
    • 18844430618 scopus 로고    scopus 로고
    • Incidence of contrast nephropathy from cerebral CT angiography and CT perfusion imaging
    • DOI 10.1212/01.WNL.0000161845.69114.62
    • Josephson SA, Dillon WP, Smith WS. Incidence of contrast nephropathy from cerebral CT angiography and CT perfusion imaging. Neurology 2005;64(10):1805-1806. (Pubitemid 40695827)
    • (2005) Neurology , vol.64 , Issue.10 , pp. 1805-1806
    • Josephson, S.A.1    Dillon, W.P.2    Smith, W.S.3
  • 32
    • 8344219682 scopus 로고    scopus 로고
    • Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: A randomized study
    • DOI 10.1007/s00330-004-2439-5
    • Suzuki H, Oshima H, Shiraki N, Ikeya C, Shibamoto Y. Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study. Eur Radiol 2004;14(11):2099-2104. (Pubitemid 39481184)
    • (2004) European Radiology , vol.14 , Issue.11 , pp. 2099-2104
    • Suzuki, H.1    Oshima, H.2    Shiraki, N.3    Ikeya, C.4    Shibamoto, Y.5
  • 34
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT
    • Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000;217(2):430-435.
    • (2000) Radiology , vol.217 , Issue.2 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 35
    • 7044228012 scopus 로고    scopus 로고
    • Radiation dose and image quality in pediatric CT: Effect of technical factors and phantom size and shape
    • DOI 10.1148/radiol.2332032107
    • Siegel MJ, Schmidt B, Bradley D, Suess C, Hildebolt C. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. Radiology 2004;233(2):515-522. (Pubitemid 39423813)
    • (2004) Radiology , vol.233 , Issue.2 , pp. 515-522
    • Siegel, M.J.1    Schmidt, B.2    Bradley, D.3    Suess, C.4    Hildebolt, C.5
  • 36
    • 44449089365 scopus 로고    scopus 로고
    • Effect of x-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: A chest-phantom-study
    • DOI 10.1097/RLI.0b013e3181690042, PII 0000442420080600000006
    • Szucs-Farkas Z, Verdun FR, von Allmen G, Mini RL, Vock P. Effect of x-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom-study. Invest Radiol 2008;43(6):374-381. (Pubitemid 351769895)
    • (2008) Investigative Radiology , vol.43 , Issue.6 , pp. 374-381
    • Szucs-Farkas, Z.1    Verdun, F.R.2    Von Allmen, G.3    Mini, R.L.4    Vock, P.5
  • 37
    • 64949151537 scopus 로고    scopus 로고
    • Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults
    • Sodickson A, Baeyens PF, Andriole KP, et al. Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology 2009;251(1):175-184.
    • (2009) Radiology , vol.251 , Issue.1 , pp. 175-184
    • Sodickson, A.1    Baeyens, P.F.2    Andriole, K.P.3
  • 38
    • 73149113560 scopus 로고    scopus 로고
    • Projected cancer risks from computed tomographic scans performed in the United States in 2007
    • Berrington de González A, Mahesh M, Kim KP, et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 2009;169(22):2071-2077.
    • (2009) Arch Intern Med , vol.169 , Issue.22 , pp. 2071-2077
    • Berrington De González, A.1    Mahesh, M.2    Kim, K.P.3
  • 39
    • 51549088875 scopus 로고    scopus 로고
    • Converting dose-length product to effective dose at CT
    • Huda W, Ogden KM, Khorasani MR. Converting dose-length product to effective dose at CT. Radiology 2008;248(3):995-1003.
    • (2008) Radiology , vol.248 , Issue.3 , pp. 995-1003
    • Huda, W.1    Ogden, K.M.2    Khorasani, M.R.3
  • 40
    • 78649653575 scopus 로고    scopus 로고
    • Appropriate patient selection at abdominal dual-energy CT using 80 kV: Relationship between patient size, image noise, and image quality
    • Guimarães LS, Fletcher JG, Harmsen WS, et al. Appropriate patient selection at abdominal dual-energy CT using 80 kV: relationship between patient size, image noise, and image quality. Radiology 2010;257(3):732-742.
    • (2010) Radiology , vol.257 , Issue.3 , pp. 732-742
    • Guimarães, L.S.1    Fletcher, J.G.2    Harmsen, W.S.3
  • 41
    • 73649148717 scopus 로고    scopus 로고
    • Automatic selection of tube potential for radiation dose reduction in CT: A general strategy
    • Yu L, Li H, Fletcher JG, McCollough CH. Automatic selection of tube potential for radiation dose reduction in CT: a general strategy. Med Phys 2010;37(1):234-243.
    • (2010) Med Phys , vol.37 , Issue.1 , pp. 234-243
    • Yu, L.1    Li, H.2    Fletcher, J.G.3    McCollough, C.H.4
  • 42
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience
    • Marin D, Nelson RC, Schindera ST, et al. Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm-initial clinical experience. Radiology 2010;254(1):145-153.
    • (2010) Radiology , vol.254 , Issue.1 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3
  • 43
    • 77953948373 scopus 로고    scopus 로고
    • Intravenous contrast medium administration and scan timing at CT: Considerations and approaches
    • Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010;256(1):32-61.
    • (2010) Radiology , vol.256 , Issue.1 , pp. 32-61
    • Bae, K.T.1
  • 44
    • 34648819024 scopus 로고    scopus 로고
    • Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols
    • DOI 10.1097/RCT.0b013e31802d3dd2, PII 0000472820070700000009
    • Hurwitz LM, Yoshizumi TT, Goodman PC, et al. Effective dose determination using an anthropomorphic phantom and metal oxide semiconductor field effect transistor technology for clinical adult body multidetector array computed tomography protocols. J Comput Assist Tomogr 2007;31(4):544-549. (Pubitemid 47457667)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.4 , pp. 544-549
    • Hurwitz, L.M.1    Yoshizumi, T.T.2    Goodman, P.C.3    Frush, D.P.4    Nguyen, G.5    Toncheva, G.6    Lowry, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.