Automated vs. manual cerebrospinal fluid cell counts: A work and cost analysis comparing the Sysmex XE-5000 and the Fuchs-Rosenthal manual counting chamber

Author keywords

Cell count; Cerebrospinal fluid; Cost comparison analysis; Counting chamber; Turn around time; XE 5000

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CELL COUNT; CEREBROSPINAL FLUID CYTOLOGY; CONTROLLED STUDY; COST EFFECTIVENESS ANALYSIS; DEVICE; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; FUCHS ROSENTHAL MANUAL COUNTING CHAMBER; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SYSMEX XE 5000 COUNTING CHAMBER;

EID: 80054698488     PISSN: 17515521     EISSN: 1751553X     Source Type: Journal    
DOI: 10.1111/j.1751-553X.2011.01339.x     Document Type: Article
Times cited : (63)

References (17)
  • 1
  • 2
    • 0346242757 scopus 로고    scopus 로고
    • Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others)
    • Aulesa C., Mainar I., Prieto M., Cobos N. & Galimany R. (2003) Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others). Laboratory Haematology 9, 214-224.
    • (2003) Laboratory Haematology , vol.9 , pp. 214-224
    • Aulesa, C.1    Mainar, I.2    Prieto, M.3    Cobos, N.4    Galimany, R.5
  • 3
    • 0033783597 scopus 로고    scopus 로고
    • Automated counting of white and red blood cells in the cerebrospinal fluid
    • Aune M.W. & Sandberg S. (2000) Automated counting of white and red blood cells in the cerebrospinal fluid. Clinical and Laboratory Haematology 22, 203-210.
    • (2000) Clinical and Laboratory Haematology , vol.22 , pp. 203-210
    • Aune, M.W.1    Sandberg, S.2
  • 5
    • 7444252797 scopus 로고    scopus 로고
    • An evaluation of the utility of performing body fluid counts on the coulter LH 750
    • Barnes P.W., Eby C.S. & Shimer G. (2004) An evaluation of the utility of performing body fluid counts on the coulter LH 750. Laboratory Haematology 10, 127-131.
    • (2004) Laboratory Haematology , vol.10 , pp. 127-131
    • Barnes, P.W.1    Eby, C.S.2    Shimer, G.3
  • 6
    • 63649144813 scopus 로고    scopus 로고
    • Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid
    • Boer K., Deufel T. & Reinhöfer M. (2009) Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid. Clinical Biochemistry 42, 684-691.
    • (2009) Clinical Biochemistry , vol.42 , pp. 684-691
    • Boer, K.1    Deufel, T.2    Reinhöfer, M.3
  • 7
    • 41649089333 scopus 로고    scopus 로고
    • A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparisons with hematocytometer cell counts
    • Butch A.W., Wises P.K., Wah D.T., Gornet T.G. & Fritsche H.A. (2008) A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparisons with hematocytometer cell counts. American Journal of Clinical Pathology 129, 445-450.
    • (2008) American Journal of Clinical Pathology , vol.129 , pp. 445-450
    • Butch, A.W.1    Wises, P.K.2    Wah, D.T.3    Gornet, T.G.4    Fritsche, H.A.5
  • 8
    • 80054690739 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute; International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Body fluid analysis for cellular composition; Approved Guideline 26, H56-A
    • Clinical and Laboratory Standards Institute; International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). (2006) Body fluid analysis for cellular composition; Approved Guideline 26, H56-A, 1-99.
    • (2006) , pp. 1-99
  • 10
    • 58549098561 scopus 로고    scopus 로고
    • The clinical reliability of automated cerebrospinal fluid cell counts on the Beckman-Coulter LH750 and Iris iQ200
    • Glasser L., Murphy C.A. & Machan J.T. (2009) The clinical reliability of automated cerebrospinal fluid cell counts on the Beckman-Coulter LH750 and Iris iQ200. American Journal of Clinical Pathology 131, 58-63.
    • (2009) American Journal of Clinical Pathology , vol.131 , pp. 58-63
    • Glasser, L.1    Murphy, C.A.2    Machan, J.T.3
  • 12
    • 0036919301 scopus 로고    scopus 로고
    • Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyzer
    • Hoffmann J.J. & Janssen W.C. (2002) Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyzer. Clinical Chemistry and Laboratory Medicine 40, 1168-1173.
    • (2002) Clinical Chemistry and Laboratory Medicine , vol.40 , pp. 1168-1173
    • Hoffmann, J.J.1    Janssen, W.C.2
  • 14
    • 2942604615 scopus 로고    scopus 로고
    • Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens
    • Mahieu S., Vertessen F. & Van der Planken M. (2004) Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens. Clinical and Laboratory Haematology 26, 195-199.
    • (2004) Clinical and Laboratory Haematology , vol.26 , pp. 195-199
    • Mahieu, S.1    Vertessen, F.2    Van der Planken, M.3
  • 15
    • 42749097012 scopus 로고    scopus 로고
    • Evaluation of Sysmex UF-1000i for use in cerebrospinal fluid analysis
    • Nanos N.E. & Delanghe J.R. (2008) Evaluation of Sysmex UF-1000i for use in cerebrospinal fluid analysis. Clinica Chimica Acta 392, 30-33.
    • (2008) Clinica Chimica Acta , vol.392 , pp. 30-33
    • Nanos, N.E.1    Delanghe, J.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.