Volumn 42, Issue 7-8, 2009, Pages 684-691

Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid

Author keywords

Body fluid; Cell counting; Cerebrospinal fluid; Counting chamber; CSF; Evaluation; Leukocyte; XE 5000

Indexed keywords

ANALYZER; ARTICLE; BLOOD CELL COUNT; CEREBROSPINAL FLUID ANALYSIS; COMPARATIVE STUDY; CONCENTRATION (PARAMETERS); ERYTHROCYTE; FEMALE; FLOW CYTOMETRY; HEMOCONCENTRATION; HUMAN; HUMAN EXPERIMENT; LABORATORY APPARATUS, EQUIPMENT AND SUPPLIES; LABORATORY DIAGNOSIS; LABORATORY TEST; LEUKOCYTE COUNT; LEUKOCYTE DIFFERENTIAL COUNT; MALE; MICROSCOPY; NORMAL HUMAN; PRIORITY JOURNAL;

EID: 63649144813     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2009.01.025     Document Type: Article
Times cited : (54)

References (17)
  • 1
    • 58549098561 scopus 로고    scopus 로고
    • the clinical reliability of automated cerebrospinal fluid cell counts on the Beckman-Coulter LH750 and Iris iQ200
    • Glasser L., Murphy C.A., and Machan J.T. the clinical reliability of automated cerebrospinal fluid cell counts on the Beckman-Coulter LH750 and Iris iQ200. Am J Clin Pathol 131 1 (2009) 58-63
    • (2009) Am J Clin Pathol , vol.131 , Issue.1 , pp. 58-63
    • Glasser, L.1    Murphy, C.A.2    Machan, J.T.3
  • 2
    • 2942604615 scopus 로고    scopus 로고
    • Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens
    • Mahieu S., Vertessen F., and Van der Planken M. Evaluation of ADVIA 120 CSF assay (Bayer) vs. chamber counting of cerebrospinal fluid specimens. Clin Lab Haematol 26 3 (2004) 195-199
    • (2004) Clin Lab Haematol , vol.26 , Issue.3 , pp. 195-199
    • Mahieu, S.1    Vertessen, F.2    Van der Planken, M.3
  • 3
    • 22144476162 scopus 로고    scopus 로고
    • An evaluation of the cell-dyn 3200 for counting cells in cerebrospinal and other body fluids
    • Andrews J., Setran E., McDonnel L., Kussick S., Wood B.L., and Sabath D.E. An evaluation of the cell-dyn 3200 for counting cells in cerebrospinal and other body fluids. Lab Hematol 11 2 (2005) 98-106
    • (2005) Lab Hematol , vol.11 , Issue.2 , pp. 98-106
    • Andrews, J.1    Setran, E.2    McDonnel, L.3    Kussick, S.4    Wood, B.L.5    Sabath, D.E.6
  • 4
    • 0346242757 scopus 로고    scopus 로고
    • Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others)
    • Aulesa C., Mainar I., Prieto M., Cobos N., and Galimany R. Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others). Lab Hematol 9 4 (2003) 214-224
    • (2003) Lab Hematol , vol.9 , Issue.4 , pp. 214-224
    • Aulesa, C.1    Mainar, I.2    Prieto, M.3    Cobos, N.4    Galimany, R.5
  • 5
    • 7444252797 scopus 로고    scopus 로고
    • An evaluation of the utility of performing body fluid counts on the coulter LH 750
    • Barnes P.W., Eby C.S., and Shimer G. An evaluation of the utility of performing body fluid counts on the coulter LH 750. Lab Hematol 10 3 (2004) 127-131
    • (2004) Lab Hematol , vol.10 , Issue.3 , pp. 127-131
    • Barnes, P.W.1    Eby, C.S.2    Shimer, G.3
  • 6
    • 11144355909 scopus 로고    scopus 로고
    • Automated flow cytometric analysis of blood cells in cerebrospinal fluid: analytic performance
    • Aune M.W., Becker J.L., Brugnara C., et al. Automated flow cytometric analysis of blood cells in cerebrospinal fluid: analytic performance. Am J Clin Pathol 121 5 (2004) 690-700
    • (2004) Am J Clin Pathol , vol.121 , Issue.5 , pp. 690-700
    • Aune, M.W.1    Becker, J.L.2    Brugnara, C.3
  • 8
    • 0036919301 scopus 로고    scopus 로고
    • Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyser
    • Hoffmann J.J., and Janssen W.C. Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyser. Clin Chem Lab Med 40 11 (2002) 1168-1173
    • (2002) Clin Chem Lab Med , vol.40 , Issue.11 , pp. 1168-1173
    • Hoffmann, J.J.1    Janssen, W.C.2
  • 9
    • 41649089333 scopus 로고    scopus 로고
    • A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparison with hemacytometer cell counts
    • Butch A.W., Wises P.K., Wah D.T., Gornet T.G., and Fritsche H.A. A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparison with hemacytometer cell counts. Am J Clin Pathol 129 3 (2008) 445-450
    • (2008) Am J Clin Pathol , vol.129 , Issue.3 , pp. 445-450
    • Butch, A.W.1    Wises, P.K.2    Wah, D.T.3    Gornet, T.G.4    Fritsche, H.A.5
  • 10
    • 42749097012 scopus 로고    scopus 로고
    • Evaluation of Sysmex UF-1000i for use in cerebrospinal fluid analysis
    • Nanos N.E., and Delanghe J.R. Evaluation of Sysmex UF-1000i for use in cerebrospinal fluid analysis. Clin Chim Acta 392 1-2 (2008) 30-33
    • (2008) Clin Chim Acta , vol.392 , Issue.1-2 , pp. 30-33
    • Nanos, N.E.1    Delanghe, J.R.2
  • 12
    • 33746864465 scopus 로고    scopus 로고
    • Urine flow cytometer quantification of leukocytes in samples containing a large proportion of lymphocytes
    • Yamanishi H., Imai N., Ohmine T., Nishiyama M., Suehisa E., Kanakura Y., et al. Urine flow cytometer quantification of leukocytes in samples containing a large proportion of lymphocytes. Clin Biochem 39 8 (2006) 857-859
    • (2006) Clin Biochem , vol.39 , Issue.8 , pp. 857-859
    • Yamanishi, H.1    Imai, N.2    Ohmine, T.3    Nishiyama, M.4    Suehisa, E.5    Kanakura, Y.6
  • 13
    • 0038818062 scopus 로고    scopus 로고
    • Early diagnosis of external ventricular drainage infection: results of a prospective study
    • Pfisterer W., Muhlbauer M., Czech T., and Reinprecht A. Early diagnosis of external ventricular drainage infection: results of a prospective study. J Neurol Neurosurg Psychiatry 74 7 (2003) 929-932
    • (2003) J Neurol Neurosurg Psychiatry , vol.74 , Issue.7 , pp. 929-932
    • Pfisterer, W.1    Muhlbauer, M.2    Czech, T.3    Reinprecht, A.4
  • 14
    • 0035245099 scopus 로고    scopus 로고
    • Characterization of chemical meningitis after neurological surgery
    • Forgacs P., Geyer C.A., and Freidberg S.R. Characterization of chemical meningitis after neurological surgery. Clin Infect Dis 32 2 (2001) 179-185
    • (2001) Clin Infect Dis , vol.32 , Issue.2 , pp. 179-185
    • Forgacs, P.1    Geyer, C.A.2    Freidberg, S.R.3
  • 15
    • 44949146082 scopus 로고    scopus 로고
    • Correction of ventricular cerebrospinal fluid (CSF) samples for blood content does not increase sensitivity and specificity for the detection of CSF infection
    • Boeer K., Siegmund R., Pfister W., Isenmann S., and Deufel T. Correction of ventricular cerebrospinal fluid (CSF) samples for blood content does not increase sensitivity and specificity for the detection of CSF infection. Clin Chem Lab Med 46 6 (2008) 842-848
    • (2008) Clin Chem Lab Med , vol.46 , Issue.6 , pp. 842-848
    • Boeer, K.1    Siegmund, R.2    Pfister, W.3    Isenmann, S.4    Deufel, T.5
  • 16
    • 33644838040 scopus 로고    scopus 로고
    • Corrections for leukocytes and percent of neutrophils do not match observations in blood-contaminated cerebrospinal fluid and have no value over uncorrected cells for diagnosis
    • Bonsu B.K., and Harper M.B. Corrections for leukocytes and percent of neutrophils do not match observations in blood-contaminated cerebrospinal fluid and have no value over uncorrected cells for diagnosis. Pediatr Infect Dis J 25 1 (2006) 8-11
    • (2006) Pediatr Infect Dis J , vol.25 , Issue.1 , pp. 8-11
    • Bonsu, B.K.1    Harper, M.B.2
  • 17
    • 0021250619 scopus 로고
    • Lack of validity of standard corrections for white blood cell counts of blood-contaminated cerebrospinal fluid in infants
    • Novak R.W. Lack of validity of standard corrections for white blood cell counts of blood-contaminated cerebrospinal fluid in infants. Am J Clin Pathol 82 1 (1984) 95-97
    • (1984) Am J Clin Pathol , vol.82 , Issue.1 , pp. 95-97
    • Novak, R.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.