메뉴 건너뛰기




Volumn 129, Issue 3, 2008, Pages 445-450

A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparison with hemacytometer cell counts

Author keywords

Cell counts; Cerebrospinal fluid; Erythrocytes; Iris iQ200; Nucleated cells; Serous fluid

Indexed keywords

ANALYZER; ARTICLE; BODY FLUID; CELL COUNT; CEREBROSPINAL FLUID; ERYTHROCYTE; EVALUATION; HEMACYTOMETER; LABORATORY APPARATUS, EQUIPMENT AND SUPPLIES; MICROSCOPY; MULTICENTER STUDY; PRIORITY JOURNAL; CLINICAL CHEMISTRY; CLINICAL TRIAL; COMPUTER PROGRAM; CYTOLOGY; HUMAN; INSTRUMENTATION; METHODOLOGY; SENSITIVITY AND SPECIFICITY; URINALYSIS;

EID: 41649089333     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/WR1C5WNT6UFXNC6J     Document Type: Article
Times cited : (21)

References (17)
  • 1
    • 22144470258 scopus 로고    scopus 로고
    • Cerebrospinal, synovial and serous body fluids
    • Henry JB, ed, 20th ed. Philadelphia, PA: Saunders;
    • Smith GP, Kjedsberg CR. Cerebrospinal, synovial and serous body fluids. In Henry JB, ed. Clinical Diagnosis and Management by Laboratory Methods. 20th ed. Philadelphia, PA: Saunders; 2001:403-424.
    • (2001) Clinical Diagnosis and Management by Laboratory Methods , pp. 403-424
    • Smith, G.P.1    Kjedsberg, C.R.2
  • 2
    • 0028301796 scopus 로고
    • Cerebrospinal fluid cell count following spinal cord injury
    • Travlos A, Anton H, Wing P. Cerebrospinal fluid cell count following spinal cord injury. Rehabilitation. 1994;75:293-296.
    • (1994) Rehabilitation , vol.75 , pp. 293-296
    • Travlos, A.1    Anton, H.2    Wing, P.3
  • 3
    • 0015827032 scopus 로고
    • Cells in pleural fluid; their value in differential diagnosis
    • Light RW, Erozan YS, Ball WC Jr. Cells in pleural fluid; their value in differential diagnosis. Arch Intern Med. 1973;132:854-860.
    • (1973) Arch Intern Med , vol.132 , pp. 854-860
    • Light, R.W.1    Erozan, Y.S.2    Ball Jr., W.C.3
  • 4
    • 0028006073 scopus 로고
    • Body fluid microscopy in US laboratories: Data from two College of American Pathologists surveys, with practice recommendations
    • Rabinovitch A, Cornbleet PJ. Body fluid microscopy in US laboratories: data from two College of American Pathologists surveys, with practice recommendations. Arch Pathol Lab Med. 1994;118:13-17.
    • (1994) Arch Pathol Lab Med , vol.118 , pp. 13-17
    • Rabinovitch, A.1    Cornbleet, P.J.2
  • 5
    • 0022336168 scopus 로고
    • Imprecision of ratio-derived differential leukocyte counts
    • Rümke CL. Imprecision of ratio-derived differential leukocyte counts. Blood Cells. 1985;11:311-314.
    • (1985) Blood Cells , vol.11 , pp. 311-314
    • Rümke, C.L.1
  • 6
    • 0002496733 scopus 로고
    • The statistically expected variability in differential leukocyte counting
    • Koepke JA, ed, Skokie, IL: College of American Pathologists;
    • Rümke CL. The statistically expected variability in differential leukocyte counting. In: Koepke JA, ed. Differential Leukocyte Counting. Skokie, IL: College of American Pathologists; 1978.
    • (1978) Differential Leukocyte Counting
    • Rümke, C.L.1
  • 7
    • 0035090150 scopus 로고    scopus 로고
    • The new hematology analyzer Sysmex XE-2100: Performance evaluation of a novel white blood cell differential technology
    • Ruzicka K, Veitl M, Thalhammer-Scherrer R, et al. The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology. Arch Pathol Lab Med. 2001;125:391-396.
    • (2001) Arch Pathol Lab Med , vol.125 , pp. 391-396
    • Ruzicka, K.1    Veitl, M.2    Thalhammer-Scherrer, R.3
  • 8
    • 13244265665 scopus 로고    scopus 로고
    • Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers
    • Wah DT, Wises PK, Butch AW. Analytic performance of the iQ200 automated urine microscopy analyzer and comparison with manual counts using Fuchs-Rosenthal cell chambers. Am J Clin Pathol. 2005;123:290-296.
    • (2005) Am J Clin Pathol , vol.123 , pp. 290-296
    • Wah, D.T.1    Wises, P.K.2    Butch, A.W.3
  • 10
    • 0007695278 scopus 로고
    • Cerebrospinal fluid
    • 3rd ed. Chicago, IL: ASCP Press;
    • Kjeldsberg C, Knight J. Cerebrospinal fluid. In: Body Fluids. 3rd ed. Chicago, IL: ASCP Press; 1993:65-157.
    • (1993) Body Fluids , pp. 65-157
    • Kjeldsberg, C.1    Knight, J.2
  • 11
    • 33750697645 scopus 로고    scopus 로고
    • Automated analysis of pleural fluid total and differential leukocyte counts with the Sysmex XE-2100
    • de Jonge R, Brouwer R, van Rijn M, et al. Automated analysis of pleural fluid total and differential leukocyte counts with the Sysmex XE-2100. Clin Chem Lab Med. 2006;44:1367-1371.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 1367-1371
    • de Jonge, R.1    Brouwer, R.2    van Rijn, M.3
  • 12
    • 15944368231 scopus 로고    scopus 로고
    • Performance evaluation of the application of body fluids on the Sysmex XE-2100 series automated hematology analyzer
    • Kresie L, Benavides D, Bollinger P, et al. Performance evaluation of the application of body fluids on the Sysmex XE-2100 series automated hematology analyzer. Lab Hematol. 2005;11:24-30.
    • (2005) Lab Hematol , vol.11 , pp. 24-30
    • Kresie, L.1    Benavides, D.2    Bollinger, P.3
  • 13
    • 0346242757 scopus 로고    scopus 로고
    • Use of the Advia 120 hematology analyzer in differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others
    • Aulesa C, Mainar I, Prieto M, et al. Use of the Advia 120 hematology analyzer in differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others. Lab Hematol. 2003;9:214-224.
    • (2003) Lab Hematol , vol.9 , pp. 214-224
    • Aulesa, C.1    Mainar, I.2    Prieto, M.3
  • 14
    • 11144355909 scopus 로고    scopus 로고
    • Automated flow cytometric analysis of blood cells in cerebrospinal fluid
    • Aune MW, Becker JL, Brugnara C. Automated flow cytometric analysis of blood cells in cerebrospinal fluid. Am J Clin Pathol. 2004;121:690-700.
    • (2004) Am J Clin Pathol , vol.121 , pp. 690-700
    • Aune, M.W.1    Becker, J.L.2    Brugnara, C.3
  • 15
    • 2942604615 scopus 로고    scopus 로고
    • Evaluation of ADVIA 120 CSF (Bayer) vs chamber counting of cerebrospinal fluid specimens
    • Mahieu S, Vertessen F, Van Der Planken M. Evaluation of ADVIA 120 CSF (Bayer) vs chamber counting of cerebrospinal fluid specimens. Clin Lab Haematol. 2004;26:195-199.
    • (2004) Clin Lab Haematol , vol.26 , pp. 195-199
    • Mahieu, S.1    Vertessen, F.2    Van Der Planken, M.3
  • 16
    • 0036919301 scopus 로고    scopus 로고
    • Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyzer
    • Hoffmann JJML, Janssen WCM. Automated counting of cells in cerebrospinal fluid using the CellDyn-4000 haematology analyzer. Clin Chem Lab Med. 2002;40:1168-1173.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 1168-1173
    • Hoffmann, J.J.M.L.1    Janssen, W.C.M.2
  • 17
    • 1242342215 scopus 로고    scopus 로고
    • Automated counting of white blood cells in synovial fluid
    • de Jong R, Brouwer R, Smit M, et al. Automated counting of white blood cells in synovial fluid. Rheumatology (Oxford). 2004;43:170-173.
    • (2004) Rheumatology (Oxford) , vol.43 , pp. 170-173
    • de Jong, R.1    Brouwer, R.2    Smit, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.