메뉴 건너뛰기




Volumn 48, Issue 5, 2010, Pages 665-675

Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids

Author keywords

Body fluid; Cerebrospinal fluid; Erythrocytes; Hemocytometry; Leukocytes; Sysmex XE 5000

Indexed keywords

ADULT; AGED; ARTICLE; ASCITES; BLOOD ANALYSIS; BODY FLUID; CELL COUNT; CEREBROSPINAL FLUID; CONTINUOUS AMBULATORY PERITONEAL DIALYSIS FLUID; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ERYTHROCYTE; FEMALE; HUMAN; LEUKOCYTE; MAJOR CLINICAL STUDY; MALE; MONONUCLEAR CELL; NEUTROPHIL; PLEURA FLUID; PRIORITY JOURNAL; SYNOVIAL FLUID;

EID: 77952538434     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/CCLM.2010.108     Document Type: Article
Times cited : (74)

References (22)
  • 2
    • 68949093815 scopus 로고    scopus 로고
    • Management of adult patients with ascites due to cirrhosis: An update
    • Runyon BA. Management of adult patients with ascites due to cirrhosis: an update. Hepatology 2009;49:2087-107.
    • (2009) Hepatology , vol.49 , pp. 2087-2107
    • Runyon, B.A.1
  • 4
    • 0030771145 scopus 로고    scopus 로고
    • Comparison of manual and automated cell counts in EDTA preserved syn-ovial fluids. Storage has little influence on the results
    • Salinas M, Rosas J, Iborra J, Manero H, Pascual E. Comparison of manual and automated cell counts in EDTA preserved syn-ovial fluids. Storage has little influence on the results. Ann Rheum Dis 1997;56:622-6.
    • (1997) Ann. Rheum. Dis. , vol.56 , pp. 622-626
    • Salinas, M.1    Rosas, J.2    Iborra, J.3    Manero, H.4    Pascual, E.5
  • 5
    • 0033783597 scopus 로고    scopus 로고
    • Automated counting of white and red blood cells in the cerebrospinal fluid
    • Aune MW, Sandberg S. Automated counting of white and red blood cells in the cerebrospinal fluid. Clin Lab Haematol 2000;22:203-10.
    • (2000) Clin. Lab. Haematol. , vol.22 , pp. 203-210
    • Aune, M.W.1    Sandberg, S.2
  • 6
    • 0346242757 scopus 로고    scopus 로고
    • Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others)
    • Aulesa C, Mainar I, Prieto M, Cobos N, Galimany R. Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others). Lab Hematol 2003;9:214-24.
    • (2003) Lab. Hematol. , vol.9 , pp. 214-224
    • Aulesa, C.1    Mainar, I.2    Prieto, M.3    Cobos, N.4    Galimany, R.5
  • 9
    • 0033953778 scopus 로고    scopus 로고
    • Leukocyte counts in cerebrospinal fluid with the automated hematology analyzer Cell Dyn 3500 and the urine flow cytometer UF-100
    • Ziebig R, Lun A, Sinha P. Leukocyte counts in cerebrospinal fluid with the automated hematology analyzer Cell Dyn 3500 and the urine flow cytometer UF-100. Clin Chem 2000;46:242-7.
    • (2000) Clin. Chem. , vol.46 , pp. 242-247
    • Ziebig, R.1    Lun, A.2    Sinha, P.3
  • 10
    • 0036919301 scopus 로고    scopus 로고
    • Automated counting of cells in cer-ebrospinal fluid using the CellDyn-4000 haematology analyser
    • Hoffmann JJ, Janssen WC. Automated counting of cells in cer-ebrospinal fluid using the CellDyn-4000 haematology analyser. Clin Chem Lab Med 2002;40:1168-73.
    • (2002) Clin. Chem. Lab. Med. , vol.40 , pp. 1168-1173
    • Hoffmann, J.J.1    Janssen, W.C.2
  • 11
    • 15944368231 scopus 로고    scopus 로고
    • Performance evaluation of the application of body fluids on the Sysmex XE-2100 series automated hema-tology analyzer
    • Kresie L, Benavides D, Bollinger P, Walters J, Pierson D, Richmond T, et al. Performance evaluation of the application of body fluids on the Sysmex XE-2100 series automated hema-tology analyzer. Lab Hematol 2005;11:24-30.
    • (2005) Lab. Hematol. , vol.11 , pp. 24-30
    • Kresie, L.1    Benavides, D.2    Bollinger, P.3    Walters, J.4    Pierson, D.5    Richmond, T.6
  • 12
    • 15944373557 scopus 로고    scopus 로고
    • Performance evaluation of the ADVIA 2120 hematology analyzer: An international multicenter clinical trial
    • Harris N, Jou JM, Devoto G, Lotz J, Pappas J, Wranovics D, et al. Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial. Lab Hema-tol 2005;11:62-70.
    • (2005) Lab. Hema-tol , vol.11 , pp. 62-70
    • Harris, N.1    Jou, J.M.2    Devoto, G.3    Lotz, J.4    Pappas, J.5    Wranovics, D.6
  • 13
    • 15944427129 scopus 로고    scopus 로고
    • The ADVIA 2120 hematology system: Flow cytometry-based analysis of blood and body fluids in the routine hematology laboratory
    • Harris N, Kunicka J, Kratz A. The ADVIA 2120 hematology system: flow cytometry-based analysis of blood and body fluids in the routine hematology laboratory. Lab Hematol 2005;11:47-61.
    • (2005) Lab. Hematol. , vol.11 , pp. 47-61
    • Harris, N.1    Kunicka, J.2    Kratz, A.3
  • 14
    • 0043156186 scopus 로고    scopus 로고
    • Validation of automated blood cell counter for the determination of polymorphonuclear cell count in the ascitic fluid of cirrhotic patients with or without spontaneous bacterial peritonitis
    • Angeloni S, Nicolini G, Merli M, Nicolao F, Pinto G, Aronne T, et al. Validation of automated blood cell counter for the determination of polymorphonuclear cell count in the ascitic fluid of cirrhotic patients with or without spontaneous bacterial peritonitis. Am J Gastroenterol 2003;98:1844-8.
    • (2003) Am. J. Gastroenterol. , vol.98 , pp. 1844-1848
    • Angeloni, S.1    Nicolini, G.2    Merli, M.3    Nicolao, F.4    Pinto, G.5    Aronne, T.6
  • 15
    • 0037390459 scopus 로고    scopus 로고
    • Variations in pleural fluid WBC count and differential counts with different sample containers and different methods
    • Conner BD, Lee YC, Branca P, Rogers JT, Rodriguez RM, Light RW. Variations in pleural fluid WBC count and differential counts with different sample containers and different methods. Chest 2003;123:1181-7.
    • (2003) Chest , vol.123 , pp. 1181-1187
    • Conner, B.D.1    Lee, Y.C.2    Branca, P.3    Rogers, J.T.4    Rodriguez, R.M.5    Light, R.W.6
  • 17
    • 0028215102 scopus 로고
    • Correlation between the post-mortem cell content of cerebrospinal fluid and time of death
    • Wyler D, Marty W, Bar W. Correlation between the post-mortem cell content of cerebrospinal fluid and time of death. Int J Legal Med 1994;106:194-9.
    • (1994) Int. J. Legal Med. , vol.106 , pp. 194-199
    • Wyler, D.1    Marty, W.2    Bar, W.3
  • 18
    • 0028938960 scopus 로고
    • Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH
    • Spencer CA, Takeuchi M, Kazarosyan M, MacKenzie F, Beckett GJ, Wilkinson E. Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH. Clin Chem 1995;41:367-74.
    • (1995) Clin. Chem. , vol.41 , pp. 367-374
    • Spencer, C.A.1    Takeuchi, M.2    Kazarosyan, M.3    MacKenzie, F.4    Beckett, G.J.5    Wilkinson, E.6
  • 19
    • 0028292764 scopus 로고
    • Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications. International council for standardization in haematology: Prepared by the ICSH expert panel on cytometry
    • England JM, Rowan RM, van Assendelft OW, Bull BS, Coulter WH, Fujimoto K, et al. Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications. International Council for Standardization in Haematology: prepared by the ICSH Expert Panel on Cytometry. Clin Lab Haematol 1994;16:157-74.
    • (1994) Clin. Lab. Haematol. , vol.16 , pp. 157-174
    • England, J.M.1    Rowan, R.M.2    Van Assendelft, O.W.3    Bull, B.S.4    Coulter, W.H.5    Fujimoto, K.6
  • 20
    • 63649144813 scopus 로고    scopus 로고
    • Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid
    • Boer K, Deufel T, Reinhoefer M. Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid. Clin Biochem 2009;42:684-91.
    • (2009) Clin. Biochem. , vol.42 , pp. 684-691
    • Boer, K.1    Deufel, T.2    Reinhoefer, M.3
  • 21
    • 0021132594 scopus 로고
    • Lysis of erythrocytes and leukocytes in traumatic lumbar punctures
    • Chow G, Schmidley JW. Lysis of erythrocytes and leukocytes in traumatic lumbar punctures. Arch Neurol 1984;41:1084-5.
    • (1984) Arch. Neurol. , vol.41 , pp. 1084-1085
    • Chow, G.1    Schmidley, J.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.