-
1
-
-
70349194402
-
A new 15-50 MHz array-based micro-ultrasound scanner for preclinical imaging
-
F. S. Foster, J. Mehi, M. Lukacs, D. Hirson, C. White, C. Chaggares, and A. Needles, "A new 15-50 MHz array-based micro-ultrasound scanner for preclinical imaging," Ultrasound Med. Biol., vol. 35, no. 10, pp. 1700-1708, 2009.
-
(2009)
Ultrasound Med. Biol.
, vol.35
, Issue.10
, pp. 1700-1708
-
-
Foster, F.S.1
Mehi, J.2
Lukacs, M.3
Hirson, D.4
White, C.5
Chaggares, C.6
Needles, A.7
-
2
-
-
33645680480
-
Operational verification of a 40-MHz annular array transducer
-
J. A. Ketterling, S. Ramachandran, and O. Aristizábal, "Operational verification of a 40-MHz annular array transducer," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 3, pp. 623-630, 2006.
-
(2006)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.53
, Issue.3
, pp. 623-630
-
-
Ketterling, J.A.1
Ramachandran, S.2
Aristizábal, O.3
-
3
-
-
0036462539
-
A 30-MHz piezo-composite ultrasound array for medical imaging applications
-
T. A. Ritter, T. R. Shrout, R. Tutwiler, and K. K. Shung, "A 30-MHz piezo-composite ultrasound array for medical imaging applications," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 49, no. 2, pp. 217-230, 2002.
-
(2002)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.49
, Issue.2
, pp. 217-230
-
-
Ritter, T.A.1
Shrout, T.R.2
Tutwiler, R.3
Shung, K.K.4
-
4
-
-
33144485046
-
Development of a 35-MHz piezo-composite ultrasound array for medical imaging
-
J. M. Cannata, J. A. Williams, Q. Zhou, T. A. Ritter, and K. K. Shung, "Development of a 35-MHz piezo-composite ultrasound array for medical imaging," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 1, pp. 224-236, 2006.
-
(2006)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.53
, Issue.1
, pp. 224-236
-
-
Cannata, J.M.1
Williams, J.A.2
Zhou, Q.3
Ritter, T.A.4
Shung, K.K.5
-
5
-
-
33845672738
-
Performance and characterization of new micromachined high-frequency linear arrays
-
M. Lukacs, J. Yin, G. Pang, R. C. Garcia, E. Cherin, R. Williams, J. Mehi, and F. S. Foster, "Performance and characterization of new micromachined high-frequency linear arrays," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 10, pp. 1719-1729, 2006.
-
(2006)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.53
, Issue.10
, pp. 1719-1729
-
-
Lukacs, M.1
Yin, J.2
Pang, G.3
Garcia, R.C.4
Cherin, E.5
Williams, R.6
Mehi, J.7
Foster, F.S.8
-
6
-
-
34948837335
-
Fabrication and performance of a linear array based on a 1-3 composite with geometric elevation focusing
-
J. A. Brown, F. S. Foster, A. Needles, E. Cherin, and G. R. Lockwood, "Fabrication and performance of a linear array based on a 1-3 composite with geometric elevation focusing," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 54, no. 9, pp. 1888-1894, 2007.
-
(2007)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.54
, Issue.9
, pp. 1888-1894
-
-
Brown, J.A.1
Foster, F.S.2
Needles, A.3
Cherin, E.4
Lockwood, G.R.5
-
7
-
-
0034745874
-
Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers
-
R. Liu, K. A. Harasiewicz, and F. S. Foster, "Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 48, no. 1, pp. 299-306, 2001.
-
(2001)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.48
, Issue.1
, pp. 299-306
-
-
Liu, R.1
Harasiewicz, K.A.2
Foster, F.S.3
-
8
-
-
20844450401
-
Design and fabrication of ultrafine piezoelectric composites
-
J. Yin, M. Lukacs, K. A. Harasiewicz, and F. S. Foster, "Design and fabrication of ultrafine piezoelectric composites," Ultrason. Imaging, vol. 27, no. 1, pp. 54-64, 2005.
-
(2005)
Ultrason. Imaging
, vol.27
, Issue.1
, pp. 54-64
-
-
Yin, J.1
Lukacs, M.2
Harasiewicz, K.A.3
Foster, F.S.4
-
9
-
-
67649353281
-
Development of high frequency linear arrays using interdigital bonded composites
-
J. M. Cannata, J. A. Williams, C.-H. Hu, and K. K. Shung, "Development of high frequency linear arrays using interdigital bonded composites," in Proc. IEEE Ultrasonics Symp., 2008, pp. 686-689.
-
(2008)
Proc. IEEE Ultrasonics Symp.
, pp. 686-689
-
-
Cannata, J.M.1
Williams, J.A.2
Hu, C.-H.3
Shung, K.K.4
-
10
-
-
34547962524
-
High frequency piezo composites microfabricated ultrasound transducers for intravascular imaging
-
J. R. Yuan, X. Jiang, P. J. Cao, A. Sadaka, R. Bautista, K. Snook, and P. W. Rehrig, "High frequency piezo composites microfabricated ultrasound transducers for intravascular imaging," in Proc. IEEE Ultrasonics Symp., 2006, pp. 264-268.
-
(2006)
Proc. IEEE Ultrasonics Symp.
, pp. 264-268
-
-
Yuan, J.R.1
Jiang, X.2
Cao, P.J.3
Sadaka, A.4
Bautista, R.5
Snook, K.6
Rehrig, P.W.7
-
11
-
-
21644455500
-
Net-shape ceramic processing as a route to ultrafine scale 1-3 connectivity piezoelectric ceramic-polymer composite transducers
-
S. Cochran, A. Abrar, K. J. Kirk, D. Zhang, T. W. Button, B. Su, C. Meggs, and N. Porch, "Net-shape ceramic processing as a route to ultrafine scale 1-3 connectivity piezoelectric ceramic-polymer composite transducers," in Proc. IEEE Ultrasonics Symp., 2004, pp. 1682-1685.
-
(2004)
Proc. IEEE Ultrasonics Symp.
, pp. 1682-1685
-
-
Cochran, S.1
Abrar, A.2
Kirk, K.J.3
Zhang, D.4
Button, T.W.5
Su, B.6
Meggs, C.7
Porch, N.8
-
12
-
-
0036992713
-
2-2 PZT-polymer composites for high frequency (>20 MHz) ultrasound transducers
-
W. Hackenberger, S. Kwon, P. Rehrig, K. Snook, S. Rhee, and X. Geng, "2-2 PZT-polymer composites for high frequency (>20 MHz) ultrasound transducers," in Proc. IEEE Ultrasonics Symp., 2002, pp. 1253-1256.
-
(2002)
Proc. IEEE Ultrasonics Symp.
, pp. 1253-1256
-
-
Hackenberger, W.1
Kwon, S.2
Rehrig, P.3
Snook, K.4
Rhee, S.5
Geng, X.6
-
13
-
-
80054068921
-
Post positioning for interdigital bonded composite
-
Apr. 13
-
J. A. Williams, J. M. Cannata, R. Liu, and K. K. Shung, "Post positioning for interdigital bonded composite," U.S. Patent 7 695 784, Apr. 13, 2010.
-
(2010)
U.S. Patent 7 695 784
-
-
Williams, J.A.1
Cannata, J.M.2
Liu, R.3
Shung, K.K.4
-
14
-
-
0031237725
-
Piezoceramics for high-frequency (20 to 100 MHz) single-element imaging transducers
-
M. J. Zipparo, K. K. Shung, and T. R. Shrout, "Piezoceramics for high-frequency (20 to 100 MHz) single-element imaging transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 44, no. 5, pp. 1038-1048, 1997.
-
(1997)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.44
, Issue.5
, pp. 1038-1048
-
-
Zipparo, M.J.1
Shung, K.K.2
Shrout, T.R.3
-
15
-
-
0026220270
-
Characterization of lead zirconate titanate ceramics for use in miniature high-frequency (20-80 MHz) transducers
-
F. S. Foster, L. K. Ryan, and D. H. Turnbull, "Characterization of lead zirconate titanate ceramics for use in miniature high-frequency (20-80 MHz) transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 38, no. 5, pp. 446-453, 1991.
-
(1991)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.38
, Issue.5
, pp. 446-453
-
-
Foster, F.S.1
Ryan, L.K.2
Turnbull, D.H.3
-
16
-
-
3142667531
-
3 ceramics
-
3 ceramics," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 51, no. 7, pp. 908-912, 2004.
-
(2004)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.51
, Issue.7
, pp. 908-912
-
-
Wang, H.1
Jiang, B.2
Shrout, T.R.3
Cao, W.4
-
17
-
-
80054073434
-
-
C TS Corp. Feb. 15, [Online]. Available:
-
C TS Corp. (2011, Feb. 15) Superior materials. [Online]. Available: http://www.ctscorp.com/components/PZT/supmat.asp
-
(2011)
Superior Materials
-
-
-
18
-
-
80054073963
-
Dicing and grinding of electro-ceramics
-
E. L. Nix, J. Corbett, J. H. Sweet, and M. Ponting, "Dicing and grinding of electro-ceramics," in World Capacitor/Resistor/Inductor Trade Statistics Conf. Europe 2005, pp. 246-264.
-
(2005)
World Capacitor/Resistor/Inductor Trade Statistics Conf. Europe
, pp. 246-264
-
-
Nix, E.L.1
Corbett, J.2
Sweet, J.H.3
Ponting, M.4
-
19
-
-
0031186587
-
Evaluation of piezocomposites for ultrasonic transducer applications-Influence of the unit cell dimensions and the properties of constituents on the performance of 2-2 piezocomposites
-
X. Geng and Q. M. Zhang, "Evaluation of piezocomposites for ultrasonic transducer applications-Influence of the unit cell dimensions and the properties of constituents on the performance of 2-2 piezocomposites," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 44, no. 4, pp. 857-872, 1997.
-
(1997)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.44
, Issue.4
, pp. 857-872
-
-
Geng, X.1
Zhang, Q.M.2
-
20
-
-
0034226634
-
Single crystal PZN/PT-polymer composites for ultrasound transducer applications
-
T. A. Ritter, X. Geng, K. K. Shung, P. D. Lopath, S.-E. Park, and T. R. Shrout, "Single crystal PZN/PT-polymer composites for ultrasound transducer applications," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 47, no. 4, pp. 792-800, 2000.
-
(2000)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.47
, Issue.4
, pp. 792-800
-
-
Ritter, T.A.1
Geng, X.2
Shung, K.K.3
Lopath, P.D.4
Park, S.-E.5
Shrout, T.R.6
-
21
-
-
67649362462
-
Fundamental performance characterisation of high frequency piezocomposites made with net-shape viscous polymer processing for medical ultrasound transducers
-
D. MacLennan, T. W. Button, J. Elgoyhen, H. Hughes, C. Meggs, G. Corner, C. E. M. Demore, S. Cochran, and D. Zhang, "Fundamental performance characterisation of high frequency piezocomposites made with net-shape viscous polymer processing for medical ultrasound transducers," in Proc. IEEE Ultrasonics Symp., 2008, pp. 58-61.
-
(2008)
Proc. IEEE Ultrasonics Symp.
, pp. 58-61
-
-
MacLennan, D.1
Button, T.W.2
Elgoyhen, J.3
Hughes, H.4
Meggs, C.5
Corner, G.6
Demore, C.E.M.7
Cochran, S.8
Zhang, D.9
-
22
-
-
0017904863
-
Design of efficient broadband piezoelectric transducers
-
C. S. DeSilets, J. D. Fraser, and G. S. Kino, "Design of efficient broadband piezoelectric transducers," IEEE Trans. Sonics Ultrason., vol. SU-25, no. 3, pp. 115-125, 1978.
-
(1978)
IEEE Trans. Sonics Ultrason.
, vol.SU-25
, Issue.3
, pp. 115-125
-
-
DeSilets, C.S.1
Fraser, J.D.2
Kino, G.S.3
-
23
-
-
0034745861
-
High frequency properties of passive materials for ultrasonic transducers
-
H. Wang, T. A. Ritter, W. Cao, and K. K. Shung, "High frequency properties of passive materials for ultrasonic transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 48, no. 1, pp. 78-84, 2001.
-
(2001)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.48
, Issue.1
, pp. 78-84
-
-
Wang, H.1
Ritter, T.A.2
Cao, W.3
Shung, K.K.4
-
24
-
-
78751671230
-
A high-frequency annular-array transducer using an interdigital bonded 1-3 composite
-
H. R. Chabok, J. M. Cannata, H. H. Kim, J. A. Williams, J. Park, and K. K. Shung, "A high-frequency annular-array transducer using an interdigital bonded 1-3 composite," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 58, no. 1, pp. 206-214, 2011.
-
(2011)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.58
, Issue.1
, pp. 206-214
-
-
Chabok, H.R.1
Cannata, J.M.2
Kim, H.H.3
Williams, J.A.4
Park, J.5
Shung, K.K.6
-
25
-
-
0003444118
-
-
Ph.D. dissertation, Dept. of Bioengineering, The Pennsylvania State University
-
T. A. Ritter, "Design, fabrication and testing of high frequency (> 20 MHz) composite ultrasound imaging arrays," Ph.D. dissertation, Dept. of Bioengineering, The Pennsylvania State University, 2000.
-
(2000)
Design, Fabrication and Testing of High Frequency (> 20 MHz) Composite Ultrasound Imaging Arrays
-
-
Ritter, T.A.1
-
26
-
-
24044478820
-
Field: A program for simulating ultrasound systems
-
J. Jensen, "Field: A program for simulating ultrasound systems," Med. Biol. Eng. Comput., vol. 34, no. 1, pp. 351-353, 1996.
-
(1996)
Med. Biol. Eng. Comput.
, vol.34
, Issue.1
, pp. 351-353
-
-
Jensen, J.1
-
28
-
-
0028392028
-
Fabrication of high frequency spherically shaped ceramic transducers
-
G. R. Lockwood, D. H. Turnbull, and F. S. Foster, "Fabrication of high frequency spherically shaped ceramic transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 41, no. 2, pp. 231-235, 1994.
-
(1994)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.41
, Issue.2
, pp. 231-235
-
-
Lockwood, G.R.1
Turnbull, D.H.2
Foster, F.S.3
-
29
-
-
80054054352
-
Design of a 64 channel analog receive beamformer for high frequency arrays
-
P4-M3-2
-
L. Zhang, C.-H. Hu, J. T. Yen, and K. K. Shung, "Design of a 64 channel analog receive beamformer for high frequency arrays," in Proc. IEEE Ultrasonics Symp., 2010, P4-M3-2.
-
(2010)
Proc. IEEE Ultrasonics Symp.
-
-
Zhang, L.1
Hu, C.-H.2
Yen, J.T.3
Shung, K.K.4
-
30
-
-
77957692756
-
Anechoic sphere phantoms for estimating 3-D resolution of very-high-frequency-ultrasound scanners
-
E. L. Madsen, G. R. Frank, M. M. McCormick, M. E. Deaner, and T. A. Stiles, "Anechoic sphere phantoms for estimating 3-D resolution of very-high-frequency-ultrasound scanners," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 57, no. 10, pp. 2284-2292, 2010.
-
(2010)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.57
, Issue.10
, pp. 2284-2292
-
-
Madsen, E.L.1
Frank, G.R.2
McCormick, M.M.3
Deaner, M.E.4
Stiles, T.A.5
-
31
-
-
54049140601
-
Sidelobe suppression in ultrasound imaging using dual apodization
-
C. H. Seo and J. T. Yen, "Sidelobe suppression in ultrasound imaging using dual apodization," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 55, no. 10, pp. 2198-2210, 2008.
-
(2008)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.55
, Issue.10
, pp. 2198-2210
-
-
Seo, C.H.1
Yen, J.T.2
|