메뉴 건너뛰기




Volumn 27, Issue 1, 2005, Pages 54-64

Design and fabrication of ultrafine piezoelectric composites

Author keywords

Composite; High frequency; Transducer; Ultrasound

Indexed keywords

COMPOSITE MATERIALS; ELECTROMECHANICAL COUPLING; FABRICATION; PIEZOELECTRIC MATERIALS; PIEZOELECTRICITY; TRANSDUCERS; ULTRASONIC APPLICATIONS; ULTRASONIC TRANSDUCERS; ULTRASONICS;

EID: 20844450401     PISSN: 01617346     EISSN: None     Source Type: Journal    
DOI: 10.1177/016173460502700104     Document Type: Article
Times cited : (4)

References (11)
  • 2
    • 0036750352 scopus 로고    scopus 로고
    • A new ultrasound instrument for in vivo microimaging of mice
    • Foster FS, Zhang MY, Zhou YQ, et al. A new ultrasound instrument for in vivo microimaging of mice, Ultrasound Med& Biol 28, 1165-1172 (2002).
    • (2002) Ultrasound Med& Biol , vol.28 , pp. 1165-1172
    • Foster, F.S.1    Zhang, M.Y.2    Zhou, Y.Q.3
  • 3
    • 0025434841 scopus 로고
    • Simulation of piezoelectric devices by two- And three-dimensional finite elements
    • Lerch R. Simulation of piezoelectric devices by two- and three-dimensional finite elements, IEEE Trans Ultrason Ferroelect Freq Contr 37, 233-247 (1990).
    • (1990) IEEE Trans Ultrason Ferroelect Freq Contr , vol.37 , pp. 233-247
    • Lerch, R.1
  • 4
    • 0024872082 scopus 로고
    • The role of piezocomposites in ultrasonic transducers
    • Smith WA. The role of piezocomposites in ultrasonic transducers, in Proc 1989 IEEE Ultrason Symp pp. 755-766 (1989).
    • (1989) Proc 1989 IEEE Ultrason Symp , pp. 755-766
    • Smith, W.A.1
  • 5
    • 20844440262 scopus 로고    scopus 로고
    • Development of a high frequency (35MHz) linear ultrasonic array using 2-2 composite elements
    • Cannata JM, Zhou QF, Shung KK. Development of a high frequency (35MHz) linear ultrasonic array using 2-2 composite elements, in Proc 2004 IEEE Ultrason Symp, pp. 894-897 (2004).
    • (2004) Proc 2004 IEEE Ultrason Symp , pp. 894-897
    • Cannata, J.M.1    Zhou, Q.F.2    Shung, K.K.3
  • 8
    • 0034745874 scopus 로고    scopus 로고
    • Interdigital pair bonding for high frequency (20-50) ultrasonic composite transducers
    • Liu R, Harasiewicz KA, Foster FS. Interdigital pair bonding for high frequency (20-50) ultrasonic composite transducers, IEEE Trans Ultrason Ferroelect Freq Contr 48, 299-306 (2001).
    • (2001) IEEE Trans Ultrason Ferroelect Freq Contr , vol.48 , pp. 299-306
    • Liu, R.1    Harasiewicz, K.A.2    Foster, F.S.3
  • 9
    • 4143126998 scopus 로고    scopus 로고
    • A comparison of model and experiment for a high frequency (35 MHz) linear ultrasonic array
    • Cannata JM, Shung KK. A comparison of model and experiment for a high frequency (35 MHz) linear ultrasonic array, in Proc 2003 IEEE Ultrason Symp, pp. 1658-1662 (2003).
    • (2003) Proc 2003 IEEE Ultrason Symp , pp. 1658-1662
    • Cannata, J.M.1    Shung, K.K.2
  • 10
    • 20844434109 scopus 로고    scopus 로고
    • Piezocomposite 30MHz linear array for medical imaging: Design challenges and performances evaluation of a 128 elements array
    • Michau S, Mauchamp P, Dufait R. Piezocomposite 30MHz linear array for medical imaging: design challenges and performances evaluation of a 128 elements array, in Proc 2004 IEEE Ultrason Symp, pp. 898-901 (2004).
    • (2004) Proc 2004 IEEE Ultrason Symp , pp. 898-901
    • Michau, S.1    Mauchamp, P.2    Dufait, R.3
  • 11
    • 0015086205 scopus 로고
    • Equivalent circuits for transducers having arbitrary even- Or odd-symmetry piezoelectric excitation
    • Leedom DA, Krimholtz R, Matthaei GL. Equivalent circuits for transducers having arbitrary even- or odd-symmetry piezoelectric excitation, IEEE Trans Son Ultrason 18, 128-141 (1971).
    • (1971) IEEE Trans Son Ultrason , vol.18 , pp. 128-141
    • Leedom, D.A.1    Krimholtz, R.2    Matthaei, G.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.