Volumn 58, Issue 1, 2011, Pages 206-214

A high-frequency annular-array transducer using an interdigital bonded 1-3 composite

Author keywords

[No Author keywords available]

Indexed keywords

1-3 COMPOSITES; ARRAY ELEMENTS; ARRAY TRANSDUCERS; BACKING LAYERS; CENTER FREQUENCY; FLEXIBLE CIRCUIT; FRACTIONAL BANDWIDTHS; HIGH FREQUENCY HF; HIGH-FREQUENCY ULTRASOUND IMAGING; INTERDIGITAL; METAL ELECTRODES; NEAREST-NEIGHBORS; NOVEL METHODS; PORCINE EYE; PULSE ECHOES;

EID: 78751671230     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2011.1787     Document Type: Article
Times cited : (35)

References (31)
  • 2
    • 0028925939 scopus 로고
    • Ultrasound backscatter microscope analysis of early mouse embryonic brain development
    • D. H. Turnbull, T. S. Bloomfield, F. S. Foster, and A. L. Joyner, "Ultrasound backscatter microscope analysis of early mouse embryonic brain development," Proc. Natl. Acad. Sci. USA, vol. 92, no. 6, pp. 2239-2243, 1995.
    • (1995) Proc. Natl. Acad. Sci. USA , vol.92 , Issue.6 , pp. 2239-2243
    • Turnbull, D.H.1    Bloomfield, T.S.2    Foster, F.S.3    Joyner, A.L.4
  • 3
    • 0030196861 scopus 로고    scopus 로고
    • A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostic
    • C. Passman and H. Ermert, "A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostic," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 43, no. 4, pp. 545-552, 1996.
    • (1996) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.43 , Issue.4 , pp. 545-552
    • Passman, C.1    Ermert, H.2
  • 4
    • 4644334484 scopus 로고    scopus 로고
    • History of ophthalmic ultrasound
    • F. L. Lizzi and D. J. Coleman, "History of ophthalmic ultrasound," J. Ultrasound Med., vol. 23, no. 10, pp. 1255-1266, 2004.
    • (2004) J. Ultrasound Med. , vol.23 , Issue.10 , pp. 1255-1266
    • Lizzi, F.L.1    Coleman, D.J.2
  • 5
    • 4844226046 scopus 로고    scopus 로고
    • Comprehensive transthoracic cardiac imaging in mice using ultrasound biomicroscopy with anatomical confirmation by magnetic resonance imaging
    • Y. Zhou, F. S. Foster, B. J. Nieman, L. Davidson, X. Chen, and R. M. Henkelman, "Comprehensive transthoracic cardiac imaging in mice using ultrasound biomicroscopy with anatomical confirmation by magnetic resonance imaging," Physiol. Genomics, vol. 18, no. 2, pp. 232-244, 2004.
    • (2004) Physiol. Genomics , vol.18 , Issue.2 , pp. 232-244
    • Zhou, Y.1    Foster, F.S.2    Nieman, B.J.3    Davidson, L.4    Chen, X.5    Henkelman, R.M.6
  • 6
    • 0032954293 scopus 로고    scopus 로고
    • In utero ultrasound backscatter microscopy of early stage mouse embryos
    • D. H. Turnbull, "In utero ultrasound backscatter microscopy of early stage mouse embryos," Comput. Med. Imaging Graph., vol. 23, no. 1, pp. 25-31, 1999.
    • (1999) Comput. Med. Imaging Graph. , vol.23 , Issue.1 , pp. 25-31
    • Turnbull, D.H.1
  • 7
    • 0020972538 scopus 로고
    • Ultrasound transducers for pulse-echo medical imaging
    • J. W. Hunt, M. Arditi, and S. Foster, "Ultrasound transducers for pulse-echo medical imaging," IEEE Trans. Biomed. Eng., vol. BME-30, no. 8, pp. 453-481, 1983.
    • (1983) IEEE Trans. Biomed. Eng. , vol.BME-30 , Issue.8 , pp. 453-481
    • Hunt, J.W.1    Arditi, M.2    Foster, S.3
  • 8
    • 0019450840 scopus 로고
    • Transient fields of concave annular arrays
    • M. Arditi, F. S. Foster, and J. W. Hunt, "Transient fields of concave annular arrays," Ultrason. Imaging, vol. 3, no. 1, pp. 37-61, 1981.
    • (1981) Ultrason. Imaging , vol.3 , Issue.1 , pp. 37-61
    • Arditi, M.1    Foster, F.S.2    Hunt, J.W.3
  • 13
    • 33744747648 scopus 로고    scopus 로고
    • Development of a high-frequency (> 50 MHz) copolymer annular-array, ultrasound transducer
    • E. J. Gottlieb, J. M. Cannata, C. H. Hu, and K. K. Shung, "Development of a high-frequency (> 50 MHz) copolymer annular-array, ultrasound transducer," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 53, no. 5, pp. 1037-1045, 2006.
    • (2006) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.53 , Issue.5 , pp. 1037-1045
    • Gottlieb, E.J.1    Cannata, J.M.2    Hu, C.H.3    Shung, K.K.4
  • 14
    • 0022955126 scopus 로고
    • Composite piezoelectric materials for medical ultrasonic imaging transducers-A review
    • W. Smith, "Composite piezoelectric materials for medical ultrasonic imaging transducers-A review," in Sixth IEEE Int. Symp. Applications of Ferroelectrics, 1986, pp. 249-256.
    • (1986) Sixth IEEE Int. Symp. Applications of Ferroelectrics , pp. 249-256
    • Smith, W.1
  • 15
    • 0026062827 scopus 로고
    • Modeling 1-3 composite piezoelectrics: Thickness-mode oscillations
    • W. A. Smith and B. Auld, "Modeling 1-3 composite piezoelectrics: Thickness-mode oscillations," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 38, pp. 40-47, 1991.
    • (1991) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.38 , pp. 40-47
    • Smith, W.A.1    Auld, B.2
  • 16
    • 4143140135 scopus 로고    scopus 로고
    • Analysis of spurious resonances in single and multi-element piezocomposite ultrasounic transducers
    • P. Reynolds, J. Hyslop, and G. Hayward, "Analysis of spurious resonances in single and multi-element piezocomposite ultrasounic transducers," in Proc. IEEE Ultrasonics Symp., 2003, pp. 1650-1653.
    • (2003) Proc. IEEE Ultrasonics Symp. , pp. 1650-1653
    • Reynolds, P.1    Hyslop, J.2    Hayward, G.3
  • 17
    • 0019572911 scopus 로고
    • PZT-epoxy piezoelectric transducers: A simplified fabrication procedure
    • H. P. Savakas, K. A. Klicker, and R. E. Newnham, "PZT-epoxy piezoelectric transducers: A simplified fabrication procedure," Mater. Res. Bull., vol. 16, no. 6, pp. 677-680, 1981.
    • (1981) Mater. Res. Bull. , vol.16 , Issue.6 , pp. 677-680
    • Savakas, H.P.1    Klicker, K.A.2    Newnham, R.E.3
  • 20
    • 21644455500 scopus 로고    scopus 로고
    • Net-shape ceramic processing as a route to ultrafine scale 1-3 connectivity piezoelectric ceramic-polymer composite transducers
    • S. Cochran, A. Abrar, K. Kirk, D. Zhang, T. Button, B. Su, and C. Meggs, "Net-shape ceramic processing as a route to ultrafine scale 1-3 connectivity piezoelectric ceramic-polymer composite transducers," in Proc. IEEE Ultrasonics Symp., 2004, pp. 1682-1685.
    • (2004) Proc. IEEE Ultrasonics Symp. , pp. 1682-1685
    • Cochran, S.1    Abrar, A.2    Kirk, K.3    Zhang, D.4    Button, T.5    Su, B.6    Meggs, C.7
  • 21
    • 0031369041 scopus 로고    scopus 로고
    • Piezocomposite of fine PZT rods realized with synchrotron radiation lithography
    • Y. Hirata, H. Nakaishi, T. Numazawa, and H. Takada, "Piezocomposite of fine PZT rods realized with synchrotron radiation lithography," in Proc. IEEE Ultrasonics Symp., 1997, pp. 887-881.
    • (1997) Proc. IEEE Ultrasonics Symp. , pp. 887-881
    • Hirata, Y.1    Nakaishi, H.2    Numazawa, T.3    Takada, H.4
  • 22
    • 0034745874 scopus 로고    scopus 로고
    • Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers
    • R. Liu, K. A. Harasiewicz, and F. S. Foster, "Interdigital pair bonding for high frequency (20-50 MHz) ultrasonic composite transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 48, no. 1, pp. 299-306, 2001.
    • (2001) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.48 , Issue.1 , pp. 299-306
    • Liu, R.1    Harasiewicz, K.A.2    Foster, F.S.3
  • 23
    • 21644481280 scopus 로고    scopus 로고
    • Ultra-fine piezoelectric composites for high frequency ultrasonic transducers
    • J. Yin, M. Lukacs, K. Harasiewicz, and S. Foster, "Ultra-fine piezoelectric composites for high frequency ultrasonic transducers," in Proc. IEEE Ultrasonics Symp., 2004, pp. 1962-1965.
    • (2004) Proc. IEEE Ultrasonics Symp. , pp. 1962-1965
    • Yin, J.1    Lukacs, M.2    Harasiewicz, K.3    Foster, S.4
  • 25
    • 0000226235 scopus 로고    scopus 로고
    • Resonance modes and losses in 1-3 piezocomposites for ultrasonic transducer applications
    • X. Geng and Q. M. Zhang, "Resonance modes and losses in 1-3 piezocomposites for ultrasonic transducer applications," J. Appl. Phys., vol. 85, no. 3, pp. 1-9, 1999.
    • (1999) J. Appl. Phys. , vol.85 , Issue.3 , pp. 1-9
    • Geng, X.1    Zhang, Q.M.2
  • 28
    • 24044478820 scopus 로고    scopus 로고
    • Field: A program for simulating ultrasound systems
    • J. Jensen, "Field: A program for simulating ultrasound systems," Med. Biol. Eng. Comput., vol. 34, no. 1, pp. 351-353, 1996.
    • (1996) Med. Biol. Eng. Comput. , vol.34 , Issue.1 , pp. 351-353
    • Jensen, J.1
  • 30
    • 33745506087 scopus 로고    scopus 로고
    • Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging
    • C. H. Hu, R. Liu, Q. Zhou, J. Yen, and K. Kirk S hung, "Coded excitation using biphase-coded pulse with mismatched filters for high-frequency ultrasound imaging," Ultrasonics, vol. 44, no. 3, pp. 330-336, 2006.
    • (2006) Ultrasonics , vol.44 , Issue.3 , pp. 330-336
    • Hu, C.H.1    Liu, R.2    Zhou, Q.3    Yen, J.4    Kirk Shung, K.5