메뉴 건너뛰기




Volumn , Issue , 2011, Pages 652-655

Cantilever-based mass sensor using high order resonances for liquid environment

Author keywords

cantilever; dynamic mode; liquid; mass sensor

Indexed keywords

CANTILEVER; DIFFERENT MODES; DYNAMIC MODE; DYNAMIC MODES; FIRST ORDER; HIGH-ORDER RESONANCES; LIQUID ENVIRONMENT; LIQUID VISCOSITY; MASS SENSITIVITY; MASS SENSOR; MASS VARIATIONS; THERMAL DRIFTS; THERMAL FLUCTUATIONS;

EID: 80053964440     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/AIM.2011.6026984     Document Type: Conference Paper
Times cited : (15)

References (9)
  • 2
    • 0035888391 scopus 로고    scopus 로고
    • Micromechanical cantilever-based biosensors
    • DOI 10.1016/S0925-4005(01)00856-5, PII S0925400501008565
    • R. Raiteri, M. Grattarola, H. J. Butt, and P. Skládal, "Micromechanical cantilever-based biosensors", Sensor. Actuat. B-Chem., vol. 79, pp. 115-126, 2001 (Pubitemid 32866876)
    • (2001) Sensors and Actuators, B: Chemical , vol.79 , Issue.2-3 , pp. 115-126
    • Raiteri, R.1    Grattarola, M.2    Butt, H.-J.3    Skladal, P.4
  • 5
    • 33846876588 scopus 로고    scopus 로고
    • Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications
    • DOI 10.1038/nnano.2006.208
    • M. Li, H. X. Tang, and M. L. Roukes, "Ultra-sensitive NEMS-based cantilevers for sensing scanned probe and very high frequency applications", Nat. Nanotechnol., vol. 2, pp. 114-120, 2007 (Pubitemid 46226371)
    • (2007) Nature Nanotechnology , vol.2 , Issue.2 , pp. 114-120
    • Li, M.1    Tang, H.X.2    Roukes, M.L.3
  • 7
    • 0036472312 scopus 로고    scopus 로고
    • Measuring the spring constant of atomic force microscope cantilevers: Thermal fluctuations and other methods
    • DOI 10.1088/0957-4484/13/1/307, PII S0957448402275984
    • R. Lévy, and M. Maaloum, "Measuring the spring constant of atomic force microscope cantilevers: thermal fluctuations and other methods", Nanotechnology, vol. 13, pp. 33-37, 2002 (Pubitemid 34180677)
    • (2002) Nanotechnology , vol.13 , Issue.1 , pp. 33-37
    • Levy, R.1    Maaloum, M.2
  • 8
    • 34547443320 scopus 로고    scopus 로고
    • Precision and accuracy of thermal calibration of atomic force microscopy cantilevers
    • G. A. Matei, E. J. Thoreson, J. R. Pratt, D. B. Newell, and N. A. Burnahm, "Precision and accuracy of thermal calibration of atomic force microscopy cantilevers", Rev. Sci. Instrum., vol. 77, p. 083703, 2006
    • (2006) Rev. Sci. Instrum. , vol.77 , pp. 083703
    • Matei, G.A.1    Thoreson, E.J.2    Pratt, J.R.3    Newell, D.B.4    Burnahm, N.A.5
  • 9
    • 0000892453 scopus 로고    scopus 로고
    • Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids
    • J. W. M. Chon, P. Mulvaney, and J. E. Sader, " Experimental validation of theoretical models for the frequency response of atomic force microscope cantilever beams immersed in fluids", J. Appl. Phys., vol. 87, pp. 3978-3988, 2000
    • (2000) J. Appl. Phys. , vol.87 , pp. 3978-3988
    • Chon, J.W.M.1    Mulvaney, P.2    Sader, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.