-
1
-
-
0031080698
-
Contrast-enhanced MRI of the breast: Accuracy, value, controversies, solutions
-
DOI 10.1016/S0720-048X(96)01142-4, PII S0720048X96011424
-
S. H. Heywang-Kbrunner, P. Viehweg, A. Heinig, and C. Kchler, Contrast-enhanced MRI of the breast: Accuracy, value, controversies, solutions., Eur. J. Radiol. 24 (2), 94-108 (1997). 10.1016/S0720-048X(96)01142-4 (Pubitemid 27165349)
-
(1997)
European Journal of Radiology
, vol.24
, Issue.2
, pp. 94-108
-
-
Heywang-Kobrunner, S.H.1
Viehweg, P.2
Heinig, A.3
Kuchler, Ch.4
-
2
-
-
17944362831
-
International investigation of breast MRI: Results of a multicentre study (11 sites) concerning diagnostic parameters for contrast-enhanced MRI based on 519 histopathologically correlated lesions
-
DOI 10.1007/s003300000745
-
S. H. Heywang-Kbrunner, International investigation of breast MRI: Results of a multicentre study (11 sites) concerning diagnostic parameters for contrast-enhanced MRI based on 519 histopathologically correlated lesions., Eur. Radiol. 11 (4), 531-546 (2001). 10.1007/s003300000745 (Pubitemid 32755488)
-
(2001)
European Radiology
, vol.11
, Issue.4
, pp. 531-546
-
-
Heywang-Kobrunner, S.H.1
Bick, U.2
Bradley Jr., W.G.3
Bone, B.4
Casselman, J.5
Coulthard, A.6
Fischer, U.7
Muller-Schimpfle, M.8
Oellinger, H.9
Patt, R.10
Teubner, J.11
Friedrich, M.12
Newstead, G.13
Holland, R.14
Schauer, A.15
Sickles, E.A.16
Tabar, L.17
Waisman, J.18
Wernecke, K.D.19
-
3
-
-
15344342936
-
Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer
-
10.1148/radiol.2333031484
-
W. A. Berg, L. Gutierrez, M. A. NessAiver, W. B. Carter, M. Bhargavan, R. S. Lewis, and O. B. Ioffe, Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer., Radiology 233 (3), 830-849 (2004). 10.1148/radiol.2333031484
-
(2004)
Radiology
, vol.233
, Issue.3
, pp. 830-849
-
-
Berg, W.A.1
Gutierrez, L.2
Nessaiver, M.A.3
Carter, W.B.4
Bhargavan, M.5
Lewis, R.S.6
Ioffe, O.B.7
-
4
-
-
34447508128
-
The current status of breast MR imaging. Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice
-
DOI 10.1148/radiol.2442051620
-
C. Kuhl, The current status of breast MR imaging. Part I. Choice of technique, image interpretation, diagnostic accuracy, and transfer to clinical practice., Radiology 244 (2), 356-378 (2007). 10.1148/radiol.2442051620 (Pubitemid 47080868)
-
(2007)
Radiology
, vol.244
, Issue.2
, pp. 356-378
-
-
Kuhl, C.1
-
5
-
-
0035008656
-
Development, standardization, and testing of a lexicon for reporting contrast-enhanced breast magnetic resonance imaging studies
-
DOI 10.1002/jmri.1127
-
D. M. Ikeda, Development, standardization, and testing of a lexicon for reporting contrast-enhanced breast magnetic resonance imaging studies., J. Magn. Reson. Imaging 13 (6), 889-895 (2001). 10.1002/jmri.v13:6 (Pubitemid 32479947)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.13
, Issue.6
, pp. 889-895
-
-
Ikeda, D.M.1
Hylton, N.M.2
Kinkel, K.3
Hochman, M.G.4
Kuhl, C.K.5
Kaiser, W.A.6
Weinreb, J.C.7
Smazal, S.F.8
Degani, H.9
Viehweg, P.10
Barclay, J.11
Schnall, M.D.12
-
7
-
-
0032828135
-
1- weighted MRI of a diffusable tracer: Standardized quantities and symbols
-
DOI 10.1002/(SICI)15 22-2586(1999 09)10:3<223 ::AID-JMR I2>3.0.CO;2-S
-
P. S. Tofts, Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols., J. Magn. Reson. Imaging 10 (3), 223-232 (1999). 10.1002/(SICI)1522-2586(199909) 10:3<>1.0.CO;2-F (Pubitemid 29463104)
-
(1999)
Journal of Magnetic Resonance Imaging
, vol.10
, Issue.3
, pp. 223-232
-
-
Tofts, P.S.1
Brix, G.2
Buckley, D.L.3
Evelhoch, J.L.4
Henderson, E.5
Knopp, M.V.6
Larsson, H.B.W.7
Lee, T.-Y.8
Mayr, N.A.9
Parker, G.J.M.10
Port, R.E.11
Taylor, J.12
Weisskoff, R.M.13
-
8
-
-
69949108796
-
Kinetic curves of malignant lesions are not consistent across MRI systems: Need for improved standardization of breast dynamic contrast-enhanced MRI acquisition
-
10.2214/AJR.08.2025
-
S. A. Jansen, A. Shimauchi, L. Zak, X. Fan, A. M. Wood, G. S. Karczmar, and G. M. Newstead, Kinetic curves of malignant lesions are not consistent across MRI systems: Need for improved standardization of breast dynamic contrast-enhanced MRI acquisition., AJR Am. J. Roentgenol. 193 (3), 832-839 (2009). 10.2214/AJR.08.2025
-
(2009)
AJR Am. J. Roentgenol.
, vol.193
, Issue.3
, pp. 832-839
-
-
Jansen, S.A.1
Shimauchi, A.2
Zak, L.3
Fan, X.4
Wood, A.M.5
Karczmar, G.S.6
Newstead, G.M.7
-
9
-
-
85027238938
-
-
See, for example, the Radiological Society of North America's Quantitative Imaging Biomarker's Alliance
-
See, for example, the Radiological Society of North America's Quantitative Imaging Biomarker's Alliance (http://www.rsna.org/Research/QIBA).
-
-
-
-
10
-
-
0036297784
-
Spoiled gradient-echo as an arterial spin tagging technique for quick evaluation of local perfusion
-
DOI 10.1002/jmri.10128
-
J. W. Chai, J. H. Chen, Y. H. Kao, J. R. Liao, C. C. C. Chen, S. K. Lee, and W. C. Chu, Spoiled gradient-echo as an arterial spin tagging technique for quick evaluation of local perfusion., J. Magn. Reson. Imaging 16 (1), 51-59 (2002). 10.1002/jmri.v16:1 (Pubitemid 34700842)
-
(2002)
Journal of Magnetic Resonance Imaging
, vol.16
, Issue.1
, pp. 51-59
-
-
Chai, J.-W.1
Chen, J.-H.2
Kao, Y.-H.3
Liao, J.-R.4
Chen, C.C.-C.5
Lee, S.-K.6
Chu, W.C.7
-
11
-
-
0242290987
-
Inflow Effect Correction in Fast Gradient-Echo Perfusion Imaging
-
DOI 10.1002/mrm.10633
-
M. K. Ivancevic, I. Zimine, X. Montet, J. N. Hyacinthe, F. Lazeyras, D. Foxall, and J. P. Vallée, Inflow effect correction in fast gradient-echo perfusion imaging., Magn. Reson. Med. 50 (5), 885-891 (2003). 10.1002/mrm.v50:5 (Pubitemid 37356567)
-
(2003)
Magnetic Resonance in Medicine
, vol.50
, Issue.5
, pp. 885-891
-
-
Ivancevic, M.K.1
Zimine, I.2
Montet, X.3
Hyacinthe, J.-N.4
Lazeyras, F.5
Foxall, D.6
Vallee, J.-P.7
-
12
-
-
77958122669
-
A microfabricated phantom for quantitative MR perfusion measurements: Validation of singular value decomposition deconvolution method
-
10.1109/TBME.2010.2055866
-
B. Ebrahimi, S. D. Swanson, and T. E. Chupp, A microfabricated phantom for quantitative MR perfusion measurements: Validation of singular value decomposition deconvolution method., IEEE Trans. Biomed. Eng. 57 (11), 2730-2736 (2010). 10.1109/TBME.2010.2055866
-
(2010)
IEEE Trans. Biomed. Eng.
, vol.57
, Issue.11
, pp. 2730-2736
-
-
Ebrahimi, B.1
Swanson, S.D.2
Chupp, T.E.3
-
13
-
-
79551658972
-
An anthropomorphic phantom for quantitative evaluation of breast MRI
-
10.1118/1.3533899
-
M. Freed, J. A. de Zwart, J. T. Loud, R. H. El Khouli, K. J. Myers, M. H. Greene, J. H. Duyn, and A. Badano, An anthropomorphic phantom for quantitative evaluation of breast MRI., Med. Phys. 38 (2), 743-753 (2011). 10.1118/1.3533899
-
(2011)
Med. Phys.
, vol.38
, Issue.2
, pp. 743-753
-
-
Freed, M.1
De Zwart, J.A.2
Loud, J.T.3
El Khouli, R.H.4
Myers, K.J.5
Greene, M.H.6
Duyn, J.H.7
Badano, A.8
-
15
-
-
34249337110
-
Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI
-
DOI 10.1016/j.mri.2006.10.011, PII S0730725X06003432
-
X. Fan, M. Medved, G. S. Karczmar, C. Yang, S. Foxley, S. Arkani, W. Recant, M. A. Zamora, H. Abe, and G. M. Newstead, Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI., Magn. Reson. Imaging 25 (5), 593-603 (2007). 10.1016/j.mri.2006.10.011 (Pubitemid 46817803)
-
(2007)
Magnetic Resonance Imaging
, vol.25
, Issue.5
, pp. 593-603
-
-
Fan, X.1
Medved, M.2
Karczmar, G.S.3
Yang, C.4
Foxley, S.5
Arkani, S.6
Recant, W.7
Zamora, M.A.8
Abe, H.9
Newstead, G.M.10
-
16
-
-
65549148766
-
Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens
-
10.1118/1.3233683
-
M. Freed, S. Miller, K. Tang, and A. Badano, Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens., Med. Phys. 36 (11), 4944-4956 (2009). 10.1118/1.3233683
-
(2009)
Med. Phys.
, vol.36
, Issue.11
, pp. 4944-4956
-
-
Freed, M.1
Miller, S.2
Tang, K.3
Badano, A.4
-
17
-
-
0021979203
-
Tissue distribution and magnetic resonance spin lattice relaxation effects of Gadolinium-DTPA
-
G. Strich, P. L. Hagan, K. H. Gerber, and R. A. Slutsky, Tissue distribution and magnetic resonance spin lattice relaxation effects of Gadolinium-DTPA., Radiology 154 (3), 723-726 (1985). (Pubitemid 15162370)
-
(1985)
Radiology
, vol.154
, Issue.3
, pp. 723-726
-
-
Strich, G.1
Hagan, P.L.2
Gerber, K.H.3
Stutsky, R.A.4
-
18
-
-
0027529272
-
Ni-DTPA doped agarose gel-A phantom material for Gd-DTPA enhancement measurements
-
10.1016/0730-725X(93)90420-I
-
P. S. Tofts, B. Shuter, and J. M. Pope, Ni-DTPA doped agarose gel-a phantom material for Gd-DTPA enhancement measurements., Magn. Reson. Imaging 11 (1), 125-133 (1993). 10.1016/0730-725X(93)90420-I
-
(1993)
Magn. Reson. Imaging
, vol.11
, Issue.1
, pp. 125-133
-
-
Tofts, P.S.1
Shuter, B.2
Pope, J.M.3
-
19
-
-
84941965835
-
-
(Elsevier, Amsterdam)
-
M. A. Bernstein, K. F. King, and X. J. Zhou, Handbook of MRI Pulse Sequences (Elsevier, Amsterdam, 2004), p. 587.
-
(2004)
Handbook of MRI Pulse Sequences
, pp. 587
-
-
Bernstein, M.A.1
King, K.F.2
Zhou, X.J.3
-
21
-
-
42449143939
-
Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences
-
DOI 10.1088/0031-9155/53/9/010, PII S0031915508575142
-
M. C. Schabel and D. L. Parker, Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences., Phys. Med. Biol. 53 (9), 2345-2373 (2008). 10.1088/0031-9155/53/9/010 (Pubitemid 351570916)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.9
, pp. 2345-2373
-
-
Schabel, M.C.1
Parker, D.L.2
-
22
-
-
85027222500
-
The effect of protocol parameters on contrast agent washout curve separability in breast DCE-MRI: A simulation study
-
(accepted)
-
M. Freed, The effect of protocol parameters on contrast agent washout curve separability in breast DCE-MRI: A simulation study., Magn. Reson. Med. (accepted)
-
Magn. Reson. Med.
-
-
Freed, M.1
-
23
-
-
0030709487
-
MRI quantitative myocardial perfusion with compartmental analysis: A rest and stress study
-
10.1002/mrm.v38:6
-
J. P. Vallée, H. D. Sostman, and J. R. MacFall, MRI quantitative myocardial perfusion with compartmental analysis: A rest and stress study., Magn. Reson. Med. 38 (6), 981-998 (1997). 10.1002/mrm.v38:6
-
(1997)
Magn. Reson. Med.
, vol.38
, Issue.6
, pp. 981-998
-
-
Vallée, J.P.1
Sostman, H.D.2
MacFall, J.R.3
-
24
-
-
0035191096
-
FAST sequences optimization for contrast media pharmacokinetic quantification in tissue
-
DOI 10.1002/jmri.10009
-
M. K. Ivancevic, I. Zimine, F. Lazeyras, D. Foxall, and J. P. Vallée, FAST sequences optimization for contrast media pharmacokinetic quantification in tissue., J. Magn. Reson. Imaging 14 (6), 771-778 (2001). 10.1002/jmri.v14:6 (Pubitemid 33101537)
-
(2001)
Journal of Magnetic Resonance Imaging
, vol.14
, Issue.6
, pp. 771-778
-
-
Ivancevic, M.K.1
Zimine, I.2
Lazeyras, F.3
Foxall, D.4
Valle, J.-P.5
-
25
-
-
33646845809
-
A simple, reproducible method for monitoring the treatment of tumours using dynamic contrast-enhanced MR imaging
-
DOI 10.1038/sj.bjc.6603140, PII 6603140
-
B. Morgan, J. F. Utting, A. Higginson, A. L. Thomas, W. P. Steward, and M. A. Horsfield, A simple, reproducible method for monitoring the treatment of tumors using dynamic contrast-enhanced MR imaging., Br. J. Cancer 94 (10), 1420-1427 (2006). 10.1038/sj.bjc.6603140 (Pubitemid 43772276)
-
(2006)
British Journal of Cancer
, vol.94
, Issue.10
, pp. 1420-1427
-
-
Morgan, B.1
Utting, J.F.2
Higginson, A.3
Thomas, A.L.4
Steward, W.P.5
Horsfield, M.A.6
-
26
-
-
9644281549
-
Comparative study of FAST gradient echo MRI sequences: Phantom study
-
DOI 10.1002/jmri.20205
-
R. L. Perrin, M. K. Ivancevic, S. Kozerke, and J. P. Vallée, Comparative study of FAST gradient echo MRI sequence: Phantom study., J. Magn. Reson. Imaging 20 (6), 1030-1038 (2004). 10.1002/jmri.v20:6 (Pubitemid 39577906)
-
(2004)
Journal of Magnetic Resonance Imaging
, vol.20
, Issue.6
, pp. 1030-1038
-
-
Perrin, R.L.1
Ivancevic, M.K.2
Kozerke, S.3
Vallee, J.-P.4
-
27
-
-
0033043762
-
Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function
-
DOI 10.1002/(SI CI)1522-25 86(1999 02)9:2<197::AI D-JMR I7>3.0.CO;2-X
-
J. P. Vallée, F. Lazeyras, L. Kasuboski, P. Chatelain, N. Howarth, A. Righetti, and D. Didier, Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function., J. Magn. Reson. Imaging 9 (2), 197-203 (1999). 10.1002/(SICI)1522-2586(199902)9:2<>1.0. CO;2-M (Pubitemid 29115341)
-
(1999)
Journal of Magnetic Resonance Imaging
, vol.9
, Issue.2
, pp. 197-203
-
-
Vallee, J.-P.1
Lazeyras, F.2
Kasuboski, L.3
Chatelain, P.4
Howarth, N.5
Righetti, A.6
Didier, D.7
-
28
-
-
0030751213
-
Myocardial perfusion reserve: Assessment with multisection, quantitative, first-pass MR imaging
-
N. Wilke, M. Jerosch-Herold, Y. Wang, Y. Huang, B. V. Christensen, A. E. Stillman, K. Ugurbil, K. McDonald, and R. F. Wilson, Myocardial perfusion reserve: Assessment with multisection quantitative, first-pass MR imaging., Radiology 204 (2), 373-384 (1997). (Pubitemid 27337482)
-
(1997)
Radiology
, vol.204
, Issue.2
, pp. 373-384
-
-
Wilke, N.1
Jerosch-Herold, M.2
Wang, Y.3
Huang, Y.4
Christensen, B.V.5
Stillman, A.E.6
Ugurbil, K.7
McDonald, K.8
Wilson, R.F.9
-
29
-
-
85027224207
-
-
RSNA/Quantitative Imaging Biomarkers Alliance (QIBA) DCE-MRI phantom.
-
RSNA/Quantitative Imaging Biomarkers Alliance (QIBA) DCE-MRI phantom. http://qibawiki.rsna.org.
-
-
-
-
30
-
-
70349687382
-
Improved correlation to quantitative DCE-MRI pharmacokinetic parameters using a modified initial area under the uptake curve (mIAUC) approach
-
10.1002/jmri.21916
-
H. L. M. Cheng, Improved correlation to quantitative DCE-MRI pharmacokinetic parameters using a modified initial area under the uptake curve (mIAUC) approach., J. Magn. Reson. Imaging 30 (4), 864-872 (2009). 10.1002/jmri.21916
-
(2009)
J. Magn. Reson. Imaging
, vol.30
, Issue.4
, pp. 864-872
-
-
Cheng, H.L.M.1
-
31
-
-
85024611673
-
Viscosity of glycerol and its aqueous solutions
-
10.1021/ie50501a040
-
J. B. Segur and H. E. Oberstar, Viscosity of glycerol and its aqueous solutions., Ind. Eng. Chem. 43 (9), 2117-2120 (1951). 10.1021/ie50501a040
-
(1951)
Ind. Eng. Chem.
, vol.43
, Issue.9
, pp. 2117-2120
-
-
Segur, J.B.1
Oberstar, H.E.2
-
32
-
-
0033766487
-
Gd-DTPA relaxivity depends on macromolecular content
-
10.1002/1522-2594(200011)44:5<>1.0.CO;2-A
-
G. J. Stanisz and R. M. Henkelman, Gd-DTPA relaxivity depends on macromolecular content., Magn. Reson. Med. 44 (5), 665-667 (2000). 10.1002/1522-2594(200011)44:5<>1.0.CO;2-A
-
(2000)
Magn. Reson. Med.
, vol.44
, Issue.5
, pp. 665-667
-
-
Stanisz, G.J.1
Henkelman, R.M.2
-
33
-
-
0033571683
-
Diminished aqueous microviscosity of tumors in murine models measured with in vivo radiofrequency electron paramagnetic resonance
-
H. J. Halpern, G. V. R. Chandramouli, E. D. Barth, C. Yu, M. Peric, D. J. Grdina, and B. A. Teicher, Diminished aqueous microviscosity of tumors in murine models measured with in vivo radiofrequency electron paramagnetic resonance., Cancer Res. 59 (22), 5836-5841 (1999).
-
(1999)
Cancer Res.
, vol.59
, Issue.22
, pp. 5836-5841
-
-
Halpern, H.J.1
Chandramouli, G.V.R.2
Barth, E.D.3
Yu, C.4
Peric, M.5
Grdina, D.J.6
Teicher, B.A.7
-
34
-
-
0031984399
-
Color-coded and spectral Doppler flow in breast carcinomas - Relationship with the tumor microvasculature
-
DOI 10.1023/A:1005992916193
-
C. Peters-Engl, M. Medl, M. Mirau, C. Wanner, S. Bilgi, P. Sevelda, and A. Obermair, Color-coded and spectral Doppler flow in breast carcinomas-relationship with tumor microvasculature., Breast Cancer Res. Treat. 47 (1), 83-89 (1998). 10.1023/A:1005992916193 (Pubitemid 28048154)
-
(1998)
Breast Cancer Research and Treatment
, vol.47
, Issue.1
, pp. 83-89
-
-
Peters-Engl, C.1
Medl, M.2
Mirau, M.3
Wanner, C.4
Bilgi, S.5
Sevelda, P.6
Obermair, A.7
-
35
-
-
71049117748
-
SpekCalc: A program to calculate photon spectra from tungsten anode x-ray tubes
-
10.1088/0031-9155/54/19/N01
-
G. Poludniowski, G. Landry, F. DeBlois, P. M. Evans, and F. Verhaegen, SpekCalc: A program to calculate photon spectra from tungsten anode x-ray tubes., Phys. Med. Biol. 54 (19), N433-N438 (2009). 10.1088/0031-9155/54/19/N01
-
(2009)
Phys. Med. Biol.
, vol.54
, Issue.19
-
-
Poludniowski, G.1
Landry, G.2
Deblois, F.3
Evans, P.M.4
Verhaegen, F.5
-
36
-
-
85027238560
-
-
http://www.nist.gov/pml/data/xraycoef/index.cfm.
-
-
-
|