메뉴 건너뛰기




Volumn 25, Issue 5, 2011, Pages 780-783

Functional hemodynamic parameters do not reflect volume responsiveness in the immediate phase after acute myocardial ischemia and reperfusion

Author keywords

fluid responsiveness; heart lung interaction; myocardial ischemia and reperfusion; pulse pressure variation; stroke volume variation; volume responsiveness

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; AORTA FLOW; ARTERIAL PRESSURE; ARTERY CATHETER; ARTICLE; ARTIFICIAL VENTILATION; BLOOD PRESSURE VARIABILITY; CENTRAL VENOUS PRESSURE; ECHOCARDIOGRAPHY; HEART HEMODYNAMICS; HEART INFARCTION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE PRESSURE; HEART LEFT VENTRICLE VOLUME; HEART MUSCLE ISCHEMIA; HEART MUSCLE REPERFUSION; HEART OUTPUT; HEART PRELOAD; HEART RATE; HEART STROKE VOLUME; HEART VOLUME; HEMODYNAMIC PARAMETERS; LEFT ANTERIOR DESCENDING CORONARY ARTERY; LUNG ARTERY PRESSURE; MEAN ARTERIAL PRESSURE; NONHUMAN; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; PULSE PRESSURE; REPERFUSION INJURY; SCINTILLATION PROBE; SURVIVAL; SWINE; SYSTEMIC VASCULAR RESISTANCE;

EID: 80053560759     PISSN: 10530770     EISSN: 15328422     Source Type: Journal    
DOI: 10.1053/j.jvca.2010.09.001     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • E. Rivers, B. Nguyen, and S. Havstad Early goal-directed therapy in the treatment of severe sepsis and septic shock N Engl J Med 345 2001 1368 1377
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3
  • 2
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • P.E. Marik, M. Baram, and B. Vahid Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares Chest 134 2008 172 178
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 3
    • 0035080242 scopus 로고
    • Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery
    • H. Berkenstadt, N. Margalit, and M. Hadani Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery Anesth Analg 92 1992 984 989
    • (1992) Anesth Analg , vol.92 , pp. 984-989
    • Berkenstadt, H.1    Margalit, N.2    Hadani, M.3
  • 4
    • 23744504093 scopus 로고    scopus 로고
    • Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    • DOI 10.1378/chest.128.2.848
    • C.K. Hofer, S.M. Mller, and L. Furrer Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting Chest 128 2005 848 854 (Pubitemid 41140517)
    • (2005) Chest , vol.128 , Issue.2 , pp. 848-854
    • Hofer, C.K.1    Muller, S.M.2    Furrer, L.3    Klaghofer, R.4    Genoni, M.5    Zollinger, A.6
  • 5
    • 54549102432 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure
    • C.C. Huang, J.Y. Fu, and H.C. Hu Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure Crit Care Med 36 2008 2810 2816
    • (2008) Crit Care Med , vol.36 , pp. 2810-2816
    • Huang, C.C.1    Fu, J.Y.2    Hu, H.C.3
  • 6
    • 0037906107 scopus 로고    scopus 로고
    • Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function
    • DOI 10.1097/01.CCM.0000059442.37548.E1
    • D.A. Reuter, A. Kirchner, and T.W. Felbinger Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function Crit Care Med 31 2003 1399 1404 (Pubitemid 36583850)
    • (2003) Critical Care Medicine , vol.31 , Issue.5 , pp. 1399-1404
    • Reuter, D.A.1    Kirchner, A.2    Felbinger, T.W.3    Weis, F.C.4    Kilger, E.5    Lamm, P.6    Goetz, A.E.7
  • 7
    • 80053572779 scopus 로고    scopus 로고
    • Acute coronary syndromes: Management and complications
    • M.P. Fink, E. Abraham, J.L. Vincent, Elsevier Saunders Philadelphia, PA
    • S.M. Hollenberg Acute coronary syndromes: management and complications M.P. Fink, E. Abraham, J.L. Vincent, Textbook of Critical Care 2005 Elsevier Saunders Philadelphia, PA 753 762
    • (2005) Textbook of Critical Care , pp. 753-762
    • Hollenberg, S.M.1
  • 8
    • 54549110342 scopus 로고    scopus 로고
    • Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation
    • H.K. Kim, and M.R. Pinsky Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation Crit Care Med 36 2008 2858 2862
    • (2008) Crit Care Med , vol.36 , pp. 2858-2862
    • Kim, H.K.1    Pinsky, M.R.2
  • 9
    • 57649221755 scopus 로고    scopus 로고
    • Fluid therapy in acute myocardial infarction: Evaluation of predictors of volume responsiveness
    • J. Snygg, O. Bech-Hanssen, and L. Lönn Fluid therapy in acute myocardial infarction: Evaluation of predictors of volume responsiveness Acta Anesthesiol Scand 53 2009 26 33
    • (2009) Acta Anesthesiol Scand , vol.53 , pp. 26-33
    • Snygg, J.1    Bech-Hanssen, O.2    Lönn, L.3
  • 11
    • 84943732067 scopus 로고
    • Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter
    • J. Baan, T.T. Jong, and P.L. Kerkhof Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheter Cardiovasc Res 15 1981 328 334 (Pubitemid 11125461)
    • (1981) Cardiovascular Research , vol.15 , Issue.6 , pp. 328-334
    • Baan, J.1    Aouw Jong, T.T.2    Kerkhof, P.L.M.3
  • 12
    • 0021719407 scopus 로고
    • Continuous measurement of left ventricular volume in animals and humans by conductance catheter
    • J. Baan, E.T. van der Velde, and H.G. de Bruin Continuous measurement of left ventricular volume in animals and humans by conductance catheter Circulation 70 1984 812 823 (Pubitemid 15205446)
    • (1984) Circulation , vol.70 , Issue.5 , pp. 812-823
    • Baan, J.1    Van Der Velde, E.T.2    De Bruin, H.G.3
  • 13
    • 34249097160 scopus 로고    scopus 로고
    • Positive end-expiratory pressure does not compromise myocardial contractility in myocardial ischemia/reperfusion
    • DOI 10.1097/01.shk.0000246906.32519.8e, PII 0002438220070600000008
    • J.C. Kubitz, T. Annecke, and R. Hinkel Positive end-expiratory pressure does not compromise myocardial contractility in myocardial ischemia/reperfusion Shock 27 2007 638 643 (Pubitemid 46788163)
    • (2007) Shock , vol.27 , Issue.6 , pp. 638-643
    • Kubitz, J.C.1    Annecke, T.2    Hinkel, R.3    Reuter, D.A.4    Kronas, N.5    Forkl, S.6    Boekstegers, P.7    Goetz, A.E.8    Kemming, G.I.9
  • 14
    • 28844464011 scopus 로고    scopus 로고
    • Predicting fluid responsiveness in patients undergoing cardiac surgery: Functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators
    • DOI 10.1093/bja/aei262
    • S. Preisman, S. Kogan, and H. Berkenstadt Predicting fluid responsiveness in patients undergoing cardiac surgery: Functional haemodynamic parameters including the respiratory systolic variation test and static preload indicators Br J Anaesth 95 2005 746 755 (Pubitemid 41762372)
    • (2005) British Journal of Anaesthesia , vol.95 , Issue.6 , pp. 746-755
    • Preisman, S.1    Kogan, S.2    Berkenstadt, H.3    Perel, A.4
  • 15
    • 31744436023 scopus 로고    scopus 로고
    • Clinical review: Positive end-expiratory pressure and cardiac output
    • DOI 10.1186/cc3877
    • T. Luecke, and P. Pelosi Clinical review: Positive end-expiratory pressure and cardiac output Crit Care 9 2005 607 621 (Pubitemid 43174471)
    • (2005) Critical Care , vol.9 , Issue.6 , pp. 607-621
    • Luecke, T.1    Pelosi, P.2
  • 16
    • 0028710331 scopus 로고
    • The effect of peep-ventilation on cardiac function in closed chest pigs
    • J.E. Berglund, E. Haldén, and S. Jakobson The effect of peep-ventilation on cardiac function in closed chest pigs Ups J Med Sci 99 1994 167 178
    • (1994) Ups J Med Sci , vol.99 , pp. 167-178
    • Berglund, J.E.1    Haldén, E.2    Jakobson, S.3
  • 17
    • 0038637799 scopus 로고    scopus 로고
    • Preload changes by positive pressure ventilation can be used for assessment of left ventricular systolic function
    • DOI 10.1034/j.1399-6576.2003.00084.x
    • J. Sellgren, S. Söderström, and G. Johansson Preload changes by positive pressure ventilation can be used for assessment of left ventricular systolic function Acta Anaesthesiol Scand 47 2003 541 548 (Pubitemid 36539496)
    • (2003) Acta Anaesthesiologica Scandinavica , vol.47 , Issue.5 , pp. 541-548
    • Sellgren, J.1    Soderstrom, S.2    Johansson, G.3    Biber, B.4    Haggmark, S.5    Ponten, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.