메뉴 건너뛰기




Volumn 5242 LNCS, Issue PART 2, 2008, Pages 271-279

Fieldmap-free retrospective registration and distortion correction for EPI-based functional imaging

Author keywords

[No Author keywords available]

Indexed keywords

MAGNETIC RESONANCE IMAGING; MEDICAL COMPUTING; PERTURBATION TECHNIQUES; SHIMS;

EID: 80053474442     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-85990-1_33     Document Type: Conference Paper
Times cited : (6)

References (19)
  • 1
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from BO field variations
    • Jezzard, P., Balaban, R.: Correction for geometric distortion in echo planar images from BO field variations. Magn. Reson. Med. 34, 65-73 (1995)
    • (1995) Magn. Reson. Med , vol.34 , pp. 65-73
    • Jezzard, P.1    Balaban, R.2
  • 2
    • 0037225526 scopus 로고    scopus 로고
    • An evaluation of the use of magnetic field maps to undistort echo-planar images
    • Cusack, R., Brett, M., Osswald, K.: An evaluation of the use of magnetic field maps to undistort echo-planar images. Neurolmage 18, 127-142 (2003)
    • (2003) Neurolmage , vol.18 , pp. 127-142
    • Cusack, R.1    Brett, M.2    Osswald, K.3
  • 4
    • 0032883422 scopus 로고    scopus 로고
    • Sources of Distortion in Functional MRI Data
    • Jezzard, P., Clare, S.: Sources of Distortion in Functional MRI Data. Human Brain Mapping 8, 80-85 (1999)
    • (1999) Human Brain Mapping , vol.8 , pp. 80-85
    • Jezzard, P.1    Clare, S.2
  • 5
    • 30344463018 scopus 로고    scopus 로고
    • Requirements for Room Temperature Shimming of the Human Brain
    • Clare, S., Evans, J., Jezzard, P.: Requirements for Room Temperature Shimming of the Human Brain. Magnetic Resonance in Medicine 55, 210-214 (2006)
    • (2006) Magnetic Resonance in Medicine , vol.55 , pp. 210-214
    • Clare, S.1    Evans, J.2    Jezzard, P.3
  • 6
    • 4243079824 scopus 로고    scopus 로고
    • Perturbation Method for Magnetic Field Calculations of Nonconductive Objects
    • Jenkinson, M., Wilson, J.L., Jezzard, P.: Perturbation Method for Magnetic Field Calculations of Nonconductive Objects. Magn. Reson. Med. 52, 471-477 (2004)
    • (2004) Magn. Reson. Med , vol.52 , pp. 471-477
    • Jenkinson, M.1    Wilson, J.L.2    Jezzard, P.3
  • 7
    • 0030909915 scopus 로고    scopus 로고
    • Magnetic susceptibility measurement of insoluable solids by NMR: Magnetic susceptibility of bone
    • Hopkins, J.A., Wehrli, F.W.: Magnetic susceptibility measurement of insoluable solids by NMR: magnetic susceptibility of bone. Magn. Reson. Med. 37, 494 (1997)
    • (1997) Magn. Reson. Med , vol.37 , pp. 494
    • Hopkins, J.A.1    Wehrli, F.W.2
  • 8
    • 0032851488 scopus 로고    scopus 로고
    • Removal of intravoxel dephasing artifact in gradientecho images using a field-map based RF refocusing technique
    • Chen, N.K., Wyrwicz, A.M.: Removal of intravoxel dephasing artifact in gradientecho images using a field-map based RF refocusing technique. Magn. Reson. Med. 42, 807-812 (1999b)
    • (1999) Magn. Reson. Med , vol.42 , pp. 807-812
    • Chen, N.K.1    Wyrwicz, A.M.2
  • 9
    • 0026399654 scopus 로고
    • A homogeneity correction method for magnetic resonance imaging with time varying gradients
    • Noll, D.C., et al.: A homogeneity correction method for magnetic resonance imaging with time varying gradients. IEEE Trans. Med. Im., 10, 629-637 (1991)
    • (1991) IEEE Trans. Med. Im , vol.10 , pp. 629-637
    • Noll, D.C.1
  • 10
    • 0002112769 scopus 로고
    • Correcting gross distortion on echo planar images
    • Weisskoff, R.M., Davis, T.: Correcting gross distortion on echo planar images. Soc. Magn. Res. Abstr. 11, 4515 (1992)
    • (1992) Soc. Magn. Res. Abstr , vol.11 , pp. 4515
    • Weisskoff, R.M.1    Davis, T.2
  • 11
    • 0000537642 scopus 로고
    • Correction of geometric distortion in echo planar images
    • Bowtell, R., et al.: Correction of geometric distortion in echo planar images. Soc. Magn. Res. Abstr. 2, 411 (1994)
    • (1994) Soc. Magn. Res. Abstr , vol.2 , pp. 411
    • Bowtell, R.1
  • 12
    • 0009911246 scopus 로고
    • Reduction of geometric distortion in echoplanar imaging using a multi-reference scan
    • Wan, X., Gullbert, G.T., Parker, D.: Reduction of geometric distortion in echoplanar imaging using a multi-reference scan. Soc. Magn. Res. Abstr. 3, 103 (1995)
    • (1995) Soc. Magn. Res. Abstr , vol.3 , pp. 103
    • Wan, X.1    Gullbert, G.T.2    Parker, D.3
  • 13
    • 33646836633 scopus 로고    scopus 로고
    • Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI
    • Chen, N.K., Oshio, K., Panych, L.: Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI. Neurolmage 31, 609-622 (2006)
    • (2006) Neurolmage , vol.31 , pp. 609-622
    • Chen, N.K.1    Oshio, K.2    Panych, L.3
  • 14
    • 33846873463 scopus 로고    scopus 로고
    • Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance
    • Koch, K.M., et al.: Rapid calculations of susceptibility-induced magnetostatic field perturbations for in vivo magnetic resonance. Phys. Med. Biol. 51, 6381-6402 (2006)
    • (2006) Phys. Med. Biol , vol.51 , pp. 6381-6402
    • Koch, K.M.1
  • 15
    • 0036828879 scopus 로고    scopus 로고
    • Fast Robust Automated Brain Extraction
    • Smith, S.: Fast Robust Automated Brain Extraction. Human Brain Mapping 17(3), 143-155 (2002)
    • (2002) Human Brain Mapping , vol.17 , Issue.3 , pp. 143-155
    • Smith, S.1
  • 16
    • 0037225733 scopus 로고    scopus 로고
    • A fast, automated n-dimensional phase unwrapping algorithm
    • Jenkinson, M.: A fast, automated n-dimensional phase unwrapping algorithm. Magnetic Resonance in Medicine 49(1), 193-197 (2003)
    • (2003) Magnetic Resonance in Medicine , vol.49 , Issue.1 , pp. 193-197
    • Jenkinson, M.1
  • 17
    • 33646877540 scopus 로고    scopus 로고
    • Improving the registration of B0-disorted EPI images using calculated cost function weights
    • Jenkinson, M.: Improving the registration of B0-disorted EPI images using calculated cost function weights. In: 10 Int. Conf. on Func Mapping Human Brain (2004)
    • (2004) 10 Int. Conf. on Func Mapping Human Brain
    • Jenkinson, M.1
  • 18
    • 0035384136 scopus 로고    scopus 로고
    • A Global Optimisation Method for Robust Affine Registration of Brain Images
    • Jenkinson, M., Smith, S.: A Global Optimisation Method for Robust Affine Registration of Brain Images. Medical Image Analysis 5(2), 143-156 (2001)
    • (2001) Medical Image Analysis , vol.5 , Issue.2 , pp. 143-156
    • Jenkinson, M.1    Smith, S.2
  • 19
    • 0036425968 scopus 로고    scopus 로고
    • Improved Optimisation for the Robust and Accurate Linear Registration and Motion Correction of Brain Images
    • Jenkinson, M., et al.: Improved Optimisation for the Robust and Accurate Linear Registration and Motion Correction of Brain Images. Neurolmage 17(2), 825-841 (2002)
    • (2002) Neurolmage , vol.17 , Issue.2 , pp. 825-841
    • Jenkinson, M.1