메뉴 건너뛰기




Volumn 42, Issue 4, 1999, Pages 807-812

Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique

Author keywords

Gradient echo image; Magnetic field inhomogeneity; RF refocusing technique; Slice dephasing artifact

Indexed keywords

IMAGE ENHANCEMENT; IMAGE SEGMENTATION;

EID: 0032851488     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199910)42:4<807::AID-MRM25>3.0.CO;2-8     Document Type: Article
Times cited : (46)

References (12)
  • 1
    • 0023801255 scopus 로고
    • The benefits of increasing spatial resolution as means of reducing artifacts due to field inhomogeneities
    • Young IR, Cox IJ, Bryant DJ, Bydder GM. The benefits of increasing spatial resolution as means of reducing artifacts due to field inhomogeneities. Magn Reson Med 1988;6:585-590.
    • (1988) Magn Reson Med , vol.6 , pp. 585-590
    • Young, I.R.1    Cox, I.J.2    Bryant, D.J.3    Bydder, G.M.4
  • 2
    • 0023937754 scopus 로고
    • Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
    • Frahm J, Merboldt K-D, Hanicke W. Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation. Magn Reson Med 1988;6:474-480.
    • (1988) Magn Reson Med , vol.6 , pp. 474-480
    • Frahm, J.1    Merboldt, K.-D.2    Hanicke, W.3
  • 3
    • 0026500406 scopus 로고
    • Reduction of susceptibility artifact in gradient-echo imaging
    • Cho ZH, Ro YM. Reduction of susceptibility artifact in gradient-echo imaging. Magn Reson Med 1992;23:193-200.
    • (1992) Magn Reson Med , vol.23 , pp. 193-200
    • Cho, Z.H.1    Ro, Y.M.2
  • 5
    • 0031931936 scopus 로고    scopus 로고
    • Removal of local field gradient artifacts in T2* weighted images at high fields by gradient-echo slice excitation profile imaging
    • Yang QX, Williams GD, Demeure RJ, Mosher TJ, Smith MB. Removal of local field gradient artifacts in T2* weighted images at high fields by gradient-echo slice excitation profile imaging. Magn Reson Med 1998; 39:402-409.
    • (1998) Magn Reson Med , vol.39 , pp. 402-409
    • Yang, Q.X.1    Williams, G.D.2    Demeure, R.J.3    Mosher, T.J.4    Smith, M.B.5
  • 6
    • 0029399454 scopus 로고
    • Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities
    • Constable RT. Functional MR imaging using gradient-echo echo-planar imaging in the presence of large static field inhomogeneities. J Magn Reson Imaging 1995;5:746-752.
    • (1995) J Magn Reson Imaging , vol.5 , pp. 746-752
    • Constable, R.T.1
  • 7
    • 0028142827 scopus 로고
    • Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 tesla
    • Ordidge RJ, Gorell JM, Deniau JC, Knight RA, Helpern JA. Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 tesla. Magn Reson Med 1994;32:335-341.
    • (1994) Magn Reson Med , vol.32 , pp. 335-341
    • Ordidge, R.J.1    Gorell, J.M.2    Deniau, J.C.3    Knight, R.A.4    Helpern, J.A.5
  • 9
    • 0003321956 scopus 로고    scopus 로고
    • Reduction of susceptibility effects in BOLD fMRI using tailored RF pulses
    • Sydney
    • Glover GH, Lai S. Reduction of susceptibility effects in BOLD fMRI using tailored RF pulses. In: Proceedings of the ISMRM 6th Scientific Meeting, Sydney, 1998. p 298.
    • (1998) Proceedings of the ISMRM 6th Scientific Meeting , pp. 298
    • Glover, G.H.1    Lai, S.2
  • 10
    • 45149145242 scopus 로고
    • A k-space analysis of small-tip-angle excitation
    • Pauly J, Nishimura D, Macovski A. A k-space analysis of small-tip-angle excitation. J Magn Reson 1989;81:43-56.
    • (1989) J Magn Reson , vol.81 , pp. 43-56
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 12
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numerical simulations and applications to cerebral physiology
    • Fisel CR, Ackerman JL, Buxton RB, Garrido L, Belliveau JW, Rosen BR, Brady TJ. MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Magn Reson Med 1991;17:336-347.
    • (1991) Magn Reson Med , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3    Garrido, L.4    Belliveau, J.W.5    Rosen, B.R.6    Brady, T.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.