메뉴 건너뛰기




Volumn 11, Issue 7, 2011, Pages 711-720

Microfluidic platforms for performing surface-based clinical assays

Author keywords

clinical assays; diagnostics; heterogeneous immunoassays; magnetic particles; microfluidics; particles; surface based

Indexed keywords

BIOTIN; C REACTIVE PROTEIN; CARBON NANOTUBE; CARCINOEMBRYONIC ANTIGEN; CLENBUTEROL; DIMETICONE; EPIDERMAL GROWTH FACTOR RECEPTOR 2; HYDROCORTISONE; IMMUNOGLOBULIN A; IMMUNOGLOBULIN G ANTIBODY; PROTEIN P53; QUANTUM DOT; STREPTAVIDIN;

EID: 80052782099     PISSN: 14737159     EISSN: 17448352     Source Type: Journal    
DOI: 10.1586/erm.11.59     Document Type: Review
Times cited : (29)

References (67)
  • 1
    • 85013686025 scopus 로고    scopus 로고
    • 3rd Edition Elsevier Ltd. Kidlington, UK
    • Wild DG. The Immunoassay Handbook (3rd Edition).Elsevier Ltd., Kidlington, UK (2005).
    • (2005) The Immunoassay Handbook
    • Wild, D.G.1
  • 2
    • 39549094018 scopus 로고    scopus 로고
    • Current development in microfluidic immunosensing chip
    • Henares TG, Mizutani F, Hisamoto H. Current development in microfluidic immunosensing chip. Anal. Chim. Acta 611(1), 17-30 (2008).
    • (2008) Anal. Chim. Acta , vol.611 , Issue.1 , pp. 17-30
    • Henares, T.G.1    Mizutani, F.2    Hisamoto, H.3
  • 4
    • 77952650291 scopus 로고    scopus 로고
    • Microfluidic immunoassays
    • Lin CC, Wang JH, Wu HW, Lee GB. Microfluidic immunoassays. JALA 15(3), 253-274 (2010).
    • (2010) JALA , vol.15 , Issue.3 , pp. 253-274
    • Lin, C.C.1    Wang, J.H.2    Wu, H.W.3    Lee, G.B.4
  • 5
    • 33747117373 scopus 로고    scopus 로고
    • The origins and the future of microfluidics
    • DOI 10.1038/nature05058, PII NATURE05058
    • Whitesides GM. The origins and the future of microfluidics. Nature 442(7101), 368-373 (2006). (Pubitemid 44264779)
    • (2006) Nature , vol.442 , Issue.7101 , pp. 368-373
    • Whitesides, G.M.1
  • 6
    • 79551623770 scopus 로고    scopus 로고
    • Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: A review
    • Mohammed MI, Desmulliez MPY. Lab-on-a-chip based immunosensor principles and technologies for the detection of cardiac biomarkers: a review. Lab Chip. 11(4), 569-595 (2011).
    • (2011) Lab Chip. , vol.11 , Issue.4 , pp. 569-595
    • Mohammed, M.I.1    Desmulliez, M.P.Y.2
  • 8
    • 67349186400 scopus 로고    scopus 로고
    • An optical PMMA biochip based on fluorescence anisotropy: Application to C-reactive protein assay
    • Baldini F, Carloni A, Giannetti A, Porro G, Trono C. An optical PMMA biochip based on fluorescence anisotropy: application to C-reactive protein assay. Sens. Actuators B Chem. 139(1), 64-68 (2009).
    • (2009) Sens. Actuators B Chem. , vol.139 , Issue.1 , pp. 64-68
    • Baldini, F.1    Carloni, A.2    Giannetti, A.3    Porro, G.4    Trono, C.5
  • 9
    • 34147141958 scopus 로고    scopus 로고
    • Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples
    • DOI 10.1007/s10544-006-9026-2
    • Bhattacharyya A, Klapperich CM. Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples. Biomed. Microdevices 9(2), 245-251 (2007). (Pubitemid 46554132)
    • (2007) Biomedical Microdevices , vol.9 , Issue.2 , pp. 245-251
    • Bhattacharyya, A.1    Klapperich, C.M.2
  • 10
    • 79958175680 scopus 로고    scopus 로고
    • Sensitive on-chip detection of a protein biomarker in human serum and plasma over an extended dynamic range using silicon photonic microring resonators and sub-micron beads
    • Luchansky MS, Washburn AL, McClellan MS, Bailey RC. Sensitive on-chip detection of a protein biomarker in human serum and plasma over an extended dynamic range using silicon photonic microring resonators and sub-micron beads. Lab Chip. 11, 2042-2044 (2011).
    • (2011) Lab Chip. , vol.11 , pp. 2042-2044
    • Luchansky, M.S.1    Washburn, A.L.2    McClellan, M.S.3    Bailey, R.C.4
  • 11
    • 66149156128 scopus 로고    scopus 로고
    • Integrated microfluidic immunoassay for the rapid determination of clenbuterol
    • Kong J, Jiang L, Su XO, Qin JH, Du YG, Lin BC. Integrated microfluidic immunoassay for the rapid determination of clenbuterol. Lab Chip. 9(11), 1541-1547 (2009).
    • (2009) Lab Chip. , vol.9 , Issue.11 , pp. 1541-1547
    • Kong, J.1    Jiang, L.2    Su, X.O.3    Qin, J.H.4    Du, Y.G.5    Lin, B.C.6
  • 13
    • 67349222899 scopus 로고    scopus 로고
    • Microfluidic chip with porous anodic alumina integrated with PDMS/glass substrate for immuno-diagnosis
    • Yang KS, Kim HJ, Ahn JK, Kim DH. Microfluidic chip with porous anodic alumina integrated with PDMS/glass substrate for immuno-diagnosis. Curr. Appl. Phys. 9(2), E60-E65 (2009).
    • (2009) Curr. Appl. Phys. , vol.9 , Issue.2
    • Yang, K.S.1    Kim, H.J.2    Ahn, J.K.3    Kim, D.H.4
  • 14
    • 75749153307 scopus 로고    scopus 로고
    • + T-cell counting device using chemiluminescence-based detection
    • + T-cell counting device using chemiluminescence-based detection. Anal. Chem. 82(1), 36-40 (2010).
    • (2010) Anal. Chem. , vol.82 , Issue.1 , pp. 36-40
    • Wang, Z.A.K.1    Chin, S.Y.2    Chin, C.D.3
  • 16
    • 79952668680 scopus 로고    scopus 로고
    • A first step towards practical single cell proteomics: A microfluidic antibody capture chip with TIRF detection
    • Salehi-Reyhani A, Kaplinsky J, Burgin E et al. A first step towards practical single cell proteomics: a microfluidic antibody capture chip with TIRF detection. Lab Chip. 11(7), 1256-1261 (2011).
    • (2011) Lab Chip. , vol.11 , Issue.7 , pp. 1256-1261
    • Salehi-Reyhani, A.1    Kaplinsky, J.2    Burgin, E.3
  • 18
    • 47649087059 scopus 로고    scopus 로고
    • An immunoelectrochemical sensor for salivary cortisol measurement
    • Sun K, Ramgir N, Bhansali S. An immunoelectrochemical sensor for salivary cortisol measurement. Sens. Actuators B Chem. 133(2), 533-537 (2008).
    • (2008) Sens. Actuators B Chem. , vol.133 , Issue.2 , pp. 533-537
    • Sun, K.1    Ramgir, N.2    Bhansali, S.3
  • 19
    • 71849085355 scopus 로고    scopus 로고
    • Carbon nanotube-based biosensor for detection hepatitis B
    • Oh J, Yoo S, Chang YW, Lim K, Yoo KH. Carbon nanotube-based biosensor for detection hepatitis B. Curr. Appl. Phys. 9(4), E229-E231 (2009).
    • (2009) Curr. Appl. Phys. , vol.9 , Issue.4
    • Oh, J.1    Yoo, S.2    Chang, Y.W.3    Lim, K.4    Yoo, K.H.5
  • 20
    • 79954551900 scopus 로고    scopus 로고
    • Portable device based on chemiluminescence lensless imaging for personalized diagnostics through multiplex bioanalysis
    • Roda A, Mirasoli M, Dolci LS et al. Portable device based on chemiluminescence lensless imaging for personalized diagnostics through multiplex bioanalysis. Anal. Chem. 83(8), 3178-3185 (2011).
    • (2011) Anal. Chem. , vol.83 , Issue.8 , pp. 3178-3185
    • Roda, A.1    Mirasoli, M.2    Dolci, L.S.3
  • 22
    • 33645501361 scopus 로고    scopus 로고
    • Power-free sequential injection for microchip immunoassay toward point-of-care testing
    • Hosokawa K, Omata M, Sato K, Maeda M. Power-free sequential injection for microchip immunoassay toward point-of-care testing. Lab Chip. 6(2), 236-241 (2006).
    • (2006) Lab Chip. , vol.6 , Issue.2 , pp. 236-241
    • Hosokawa, K.1    Omata, M.2    Sato, K.3    Maeda, M.4
  • 23
    • 34547752309 scopus 로고    scopus 로고
    • Immunoassay on a power-free microchip with laminar flow-assisted dendritic amplification
    • DOI 10.1021/ac070659o
    • Hosokawa K, Omata M, Maeda M. Immunoassay on a power-free microchip with Laminar flow-assisted dendritic amplification. Anal. Chem. 79(15), 6000-6004 (2007). (Pubitemid 47229855)
    • (2007) Analytical Chemistry , vol.79 , Issue.15 , pp. 6000-6004
    • Hosokawa, K.1    Omata, M.2    Maeda, M.3
  • 24
    • 79953071854 scopus 로고    scopus 로고
    • Power-free microchip immunoassay of PSA in human serum for point-of-care testing
    • Okada H, Hosokawa K, Maeda M. Power-free microchip immunoassay of PSA in human serum for point-of-care testing. Anal. Sci. 27(3), 237-241 (2011).
    • (2011) Anal. Sci. , vol.27 , Issue.3 , pp. 237-241
    • Okada, H.1    Hosokawa, K.2    Maeda, M.3
  • 25
    • 58649124919 scopus 로고    scopus 로고
    • Spatial distribution of laminar flow-assisted dendritic amplification
    • Hosokawa K, Maeda M. Spatial distribution of laminar flow-assisted dendritic amplification. Lab Chip. 9(3), 464-468 (2009).
    • (2009) Lab Chip. , vol.9 , Issue.3 , pp. 464-468
    • Hosokawa, K.1    Maeda, M.2
  • 26
    • 72849110297 scopus 로고    scopus 로고
    • Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates
    • Gervais L, Delamarche E. Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates. Lab Chip. 9(23), 3330-3337 (2009).
    • (2009) Lab Chip. , vol.9 , Issue.23 , pp. 3330-3337
    • Gervais, L.1    Delamarche, E.2
  • 27
    • 41149127768 scopus 로고    scopus 로고
    • High-performance immunoassays based on through-stencil patterned antibodies and capillary systems
    • DOI 10.1021/ac702160x
    • Ziegler J, Zimmermann M, Hunziker P, Delamarche E. High-performance immunoassays based on through-stencil patterned antibodies and capillary systems. Anal. Chem. 80(5), 1763-1769 (2008). (Pubitemid 351429583)
    • (2008) Analytical Chemistry , vol.80 , Issue.5 , pp. 1763-1769
    • Ziegler, J.1    Zimmermann, M.2    Hunziker, P.3    Delamarche, E.4
  • 29
    • 77951219635 scopus 로고    scopus 로고
    • IgG anti-gliadin determination with an immunological microfluidic system applied to the automated diagnostic of the celiac disease
    • Pereira SV, Raba J, Messina GA. IgG anti-gliadin determination with an immunological microfluidic system applied to the automated diagnostic of the celiac disease. Anal. Bioanal. Chem. 396(8), 2921-2927 (2010).
    • (2010) Anal. Bioanal. Chem. , vol.396 , Issue.8 , pp. 2921-2927
    • Pereira, S.V.1    Raba, J.2    Messina, G.A.3
  • 30
    • 37549043536 scopus 로고    scopus 로고
    • PDMS micro bead cage reactor for the detection of a feto protein AFP
    • Jeong Y, Choi K, Kim J et al. PDMS micro bead cage reactor for the detection of a feto protein (AFP).Sens. Actuators B Chem. 128(2), 349-358 (2008).
    • (2008) Sens. Actuators B Chem. , vol.128 , Issue.2 , pp. 349-358
    • Jeong, Y.1    Choi, K.2    Kim, J.3
  • 31
    • 77954091833 scopus 로고    scopus 로고
    • Centrifugal microfluidics for biomedical applications
    • Gorkin R, Park J, Siegrist J et al. Centrifugal microfluidics for biomedical applications. Lab Chip. 10(14), 1758-1773 (2010).
    • (2010) Lab Chip. , vol.10 , Issue.14 , pp. 1758-1773
    • Gorkin, R.1    Park, J.2    Siegrist, J.3
  • 32
    • 34848920474 scopus 로고    scopus 로고
    • Single-bead analysis on a disk-shaped microfluidic device using an antigen-immobilized bead
    • Nagai H, Narita Y, Ohtaki M, Saito K, Wakida SI. Single-bead analysis on a disk-shaped microfluidic device using an antigen-immobilized bead. Anal. Sci. 23(8), 975-979 (2007).
    • (2007) Anal. Sci. , vol.23 , Issue.8 , pp. 975-979
    • Nagai, H.1    Narita, Y.2    Ohtaki, M.3    Saito, K.4    Wakida, S.I.5
  • 33
    • 66149108280 scopus 로고    scopus 로고
    • A fully automated immunoassay from whole blood on a disc
    • Lee BS, Lee JN, Park JM et al. A fully automated immunoassay from whole blood on a disc. Lab Chip. 9(11), 1548-1555 (2009).
    • (2009) Lab Chip. , vol.9 , Issue.11 , pp. 1548-1555
    • Lee, B.S.1    Lee, J.N.2    Park, J.M.3
  • 35
    • 67650034253 scopus 로고    scopus 로고
    • Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels
    • Jokerst JV, Raamanathan A, Christodoulides N et al. Nano-bio-chips for high performance multiplexed protein detection: determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels. Biosens. Bioelectron. 24(12), 3622-3629 (2009).
    • (2009) Biosens. Bioelectron. , vol.24 , Issue.12 , pp. 3622-3629
    • Jokerst, J.V.1    Raamanathan, A.2    Christodoulides, N.3
  • 36
    • 68049096156 scopus 로고    scopus 로고
    • On-chip immunoassay using electrostatic assembly of streptavidin-coated bead micropatterns
    • Sivagnanam V, Song B, Vandevyver C, Gijs MAM. On-chip immunoassay using electrostatic assembly of streptavidin-coated bead micropatterns. Anal. Chem. 81(15), 6509-6515 (2009).
    • (2009) Anal. Chem. , vol.81 , Issue.15 , pp. 6509-6515
    • Sivagnanam, V.1    Song, B.2    Vandevyver, C.3    Gijs, M.A.M.4
  • 37
    • 33947579961 scopus 로고    scopus 로고
    • Flow sandwich-type immunoassay in microfluidic devices based on negative dielectrophoresis
    • DOI 10.1016/j.bios.2006.11.010, PII S0956566306005525
    • Yasukawa T, Suzuki M, Sekiya T, Shiku H, Matsue T. Flow sandwich-type immunoassay in microfluidic devices based on negative dielectrophoresis. Biosens. Bioelectron. 22(11), 2730-2736 (2007). (Pubitemid 46484272)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.11 , pp. 2730-2736
    • Yasukawa, T.1    Suzuki, M.2    Sekiya, T.3    Shiku, H.4    Matsue, T.5
  • 38
    • 67949094226 scopus 로고    scopus 로고
    • Single-bead-based consecutive biochemical assays using a dielectrophoretic microfluidic platform
    • Kuo ZT, Hsieh WH. Single-bead-based consecutive biochemical assays using a dielectrophoretic microfluidic platform. Sens. Actuators B Chem. 141(1), 293-300 (2009).
    • (2009) Sens. Actuators B Chem. , vol.141 , Issue.1 , pp. 293-300
    • Kuo, Z.T.1    Hsieh, W.H.2
  • 41
    • 38549102136 scopus 로고    scopus 로고
    • Simultaneous bioassays in a microfluidic channel on plugs of different magnetic particles
    • Bronzeau S, Pamme N. Simultaneous bioassays in a microfluidic channel on plugs of different magnetic particles. Anal. Chim. Acta 609(1), 105-112 (2008).
    • (2008) Anal. Chim. Acta , vol.609 , Issue.1 , pp. 105-112
    • Bronzeau, S.1    Pamme, N.2
  • 42
    • 67349251480 scopus 로고    scopus 로고
    • An integrated microfluidic system for C-reactive protein measurement
    • Yang YN, Lin HI, Wang JH, Shiesh SC, Lee GB. An integrated microfluidic system for C-reactive protein measurement. Biosens. Bioelectron. 24(10), 3091-3096 (2009).
    • (2009) Biosens. Bioelectron. , vol.24 , Issue.10 , pp. 3091-3096
    • Yang, Y.N.1    Lin, H.I.2    Wang, J.H.3    Shiesh, S.C.4    Lee, G.B.5
  • 43
    • 73649095869 scopus 로고    scopus 로고
    • Integrated microfluidic magnetic immunosensor for quantification of human serum IgG antibodies to Helicobacter pylori
    • Pereira SV, Messina GA, Raba J. Integrated microfluidic magnetic immunosensor for quantification of human serum IgG antibodies to Helicobacter pylori. J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. 878(2), 253-257 (2010).
    • (2010) J. Chromatogr. B Analyt. Technol. Biomed. Life Sci. , vol.878 , Issue.2 , pp. 253-257
    • Pereira, S.V.1    Messina, G.A.2    Raba, J.3
  • 44
    • 70549096871 scopus 로고    scopus 로고
    • Diamagnetic repulsion - A versatile tool for label-free particle handling in microfluidic devices
    • Peyman SA, Kwan EY, Margarson O, Iles A, Pamme N. Diamagnetic repulsion - a versatile tool for label-free particle handling in microfluidic devices. J. Chromatogr. A. 1216(52), 9055-9062 (2009).
    • (2009) J. Chromatogr. A. , vol.1216 , Issue.52 , pp. 9055-9062
    • Peyman, S.A.1    Kwan, E.Y.2    Margarson, O.3    Iles, A.4    Pamme, N.5
  • 45
    • 40149088939 scopus 로고    scopus 로고
    • Rapid on-chip multi-step (bio)chemical procedures in continuous flow - Manoeuvring particles through co-laminar reagent streams
    • DOI 10.1039/b716532c
    • Peyman SA, Iles A, Pamme N. Rapid on-chip multi-step (bio)chemical procedures in continuous flow - manoeuvring particles through co-laminar reagent streams. Chem. Commun. 10, 1220-1222 (2008). (Pubitemid 351328032)
    • (2008) Chemical Communications , Issue.10 , pp. 1220-1222
    • Peyman, S.A.1    Iles, A.2    Pamme, N.3
  • 46
    • 70449090303 scopus 로고    scopus 로고
    • Mobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow
    • Peyman SA, Iles A, Pamme N. Mobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow. Lab Chip. 9(21), 3110-3117 (2009).
    • (2009) Lab Chip. , vol.9 , Issue.21 , pp. 3110-3117
    • Peyman, S.A.1    Iles, A.2    Pamme, N.3
  • 47
    • 77950930029 scopus 로고    scopus 로고
    • A microfluidic system for performing fast sequential biochemical procedures on the surface of mobile magnetic particles in continuous flow
    • Peyman SA, Patel H, Belli N, Iles A, Pamme N. A microfluidic system for performing fast, sequential biochemical procedures on the surface of mobile magnetic particles in continuous flow. Magnetohydrodynamics 45(3), 361-370 (2009).
    • (2009) Magnetohydrodynamics , vol.45 , Issue.3 , pp. 361-370
    • Peyman, S.A.1    Patel, H.2    Belli, N.3    Iles, A.4    Pamme, N.5
  • 48
    • 77951622088 scopus 로고    scopus 로고
    • Rapid multistep on-chip DNA hybridisation in continuous flow on magnetic particles
    • Vojtisek M, Iles A, Pamme N. Rapid, multistep on-chip DNA hybridisation in continuous flow on magnetic particles. Biosens. Bioelectron. 25(9), 2172-2176 (2010).
    • (2010) Biosens. Bioelectron. , vol.25 , Issue.9 , pp. 2172-2176
    • Vojtisek, M.1    Iles, A.2    Pamme, N.3
  • 50
    • 77953621550 scopus 로고    scopus 로고
    • Magnetophoretic mixing for in situ immunochemical binding on magnetic beads in a microfluidic channel
    • Ganguly R, Hahn T, Hardt S. Magnetophoretic mixing for in situ immunochemical binding on magnetic beads in a microfluidic channel. Microfluid. Nanofluid. 8(6), 739-753 (2010).
    • (2010) Microfluid. Nanofluid. , vol.8 , Issue.6 , pp. 739-753
    • Ganguly, R.1    Hahn, T.2    Hardt, S.3
  • 51
    • 78149403567 scopus 로고    scopus 로고
    • Continuous microfluidic DNA extraction using phase-transfer magnetophoresis
    • Karle M, Miwa J, Czilwik G et al. Continuous microfluidic DNA extraction using phase-transfer magnetophoresis. Lab Chip. 10(23), 3284-3290 (2010).
    • (2010) Lab Chip. , vol.10 , Issue.23 , pp. 3284-3290
    • Karle, M.1    Miwa, J.2    Czilwik, G.3
  • 52
    • 77956268742 scopus 로고    scopus 로고
    • Autonomous magnetically actuated continuous flow microimmunofluorocytometry assay
    • Sasso LA, Undar A, Zahn JD. Autonomous magnetically actuated continuous flow microimmunofluorocytometry assay. Microfluid. Nanofluid. 9(2-3), 253-265 (2010).
    • (2010) Microfluid. Nanofluid. , vol.9 , Issue.2-3 , pp. 253-265
    • Sasso, L.A.1    Undar, A.2    Zahn, J.D.3
  • 53
    • 39749186661 scopus 로고    scopus 로고
    • Recent advances in microparticle continuous separation
    • DOI 10.1049/iet-nbt:20070025
    • Kersaudy-Kerhoas M, Dhariwal R, Desmulliez MPY. Recent advances in microparticle continuous separation. IET Nanobiotechnology 2(1), 1-13 (2008). (Pubitemid 351310743)
    • (2008) IET Nanobiotechnology , vol.2 , Issue.1 , pp. 1-13
    • Kersaudy-Kerhoas, M.1    Dhariwal, R.2    Desmulliez, M.P.Y.3
  • 54
    • 77952472317 scopus 로고    scopus 로고
    • Continuous separation of cells and particles in microfluidic systems
    • Lenshof A, Laurell T. Continuous separation of cells and particles in microfluidic systems. Chem. Soc. Rev. 39(3), 1203-1217 (2010).
    • (2010) Chem. Soc. Rev. , vol.39 , Issue.3 , pp. 1203-1217
    • Lenshof, A.1    Laurell, T.2
  • 57
    • 60649086797 scopus 로고    scopus 로고
    • Wide channel dielectrophoresis-based particle exchanger with electrophoretic diffusion compensation
    • Tornay R, Braschler T, Renaud P. Wide channel dielectrophoresis-based particle exchanger with electrophoretic diffusion compensation. Lab Chip. 9(5), 657-660 (2009).
    • (2009) Lab Chip. , vol.9 , Issue.5 , pp. 657-660
    • Tornay, R.1    Braschler, T.2    Renaud, P.3
  • 59
    • 60349103436 scopus 로고    scopus 로고
    • Buffer medium exchange in continuous cell and particle streams using ultrasonic standing wave focusing
    • Augustsson P, Aberg LB, Sward- Nilsson AMK, Laurell T. Buffer medium exchange in continuous cell and particle streams using ultrasonic standing wave focusing. Microchim. Acta 164(3-4), 269-277 (2009).
    • (2009) Microchim. Acta , vol.164 , Issue.3-4 , pp. 269-277
    • Augustsson, P.1    Aberg, L.B.2    Sward-Nilsson, A.M.K.3    Laurell, T.4
  • 62
    • 52649084912 scopus 로고    scopus 로고
    • Crossing microfluidic streamlines to lyse label and wash cells
    • Morton KJ, Loutherback K, Inglis DW et al. Crossing microfluidic streamlines to lyse, label and wash cells. Lab Chip. 8(9), 1448-1453 (2008).
    • (2008) Lab Chip. , vol.8 , Issue.9 , pp. 1448-1453
    • Morton, K.J.1    Loutherback, K.2    Inglis, D.W.3
  • 63
    • 56549119892 scopus 로고    scopus 로고
    • Development of a digital microfluidic platform for point of care testing
    • Sista R, Hua ZS, Thwar P et al. Development of a digital microfluidic platform for point of care testing. Lab Chip. 8(12), 2091-2104 (2008).
    • (2008) Lab Chip. , vol.8 , Issue.12 , pp. 2091-2104
    • Sista, R.1    Hua, Z.S.2    Thwar, P.3
  • 65
    • 75749113741 scopus 로고    scopus 로고
    • Diagnostics for the developing world: Microfluidic paper-based analytical devices
    • Martinez AW, Phillips ST, Whitesides GM, Carrilho E. Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal. Chem. 82(1), 3-10 (2010).
    • (2010) Anal. Chem. , vol.82 , Issue.1 , pp. 3-10
    • Martinez, A.W.1    Phillips, S.T.2    Whitesides, G.M.3    Carrilho, E.4
  • 67
    • 77955521750 scopus 로고    scopus 로고
    • Thread as a versatile material for low-cost microfluidic diagnostics
    • Li X, Tian JF, Shen W. Thread as a versatile material for low-cost microfluidic diagnostics. ACS Appl. Mater. Interfaces 2(1), 1-6 (2010).
    • (2010) ACS Appl. Mater. Interfaces , vol.2 , Issue.1 , pp. 1-6
    • Li, X.1    Tian, J.F.2    Shen, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.