메뉴 건너뛰기




Volumn 9, Issue 2-3, 2010, Pages 253-265

Autonomous magnetically actuated continuous flow microimmunofluorocytometry assay

Author keywords

Biosensor; Fluorocytometry; Immunoassay; Magnetic actuation

Indexed keywords

ANAPHYLATOXIN; BINDING REACTIONS; CARDIAC SURGERY; CARDIOPULMONARY BYPASS; CLINICAL APPLICATION; CONTINUOUS FLOWS; DEVICE OPERATIONS; EXTERNAL CONTROL; FLUORESCENCE DETECTION; FLUOROCYTOMETRY; IMMUNOASSAY; INTEGRATED FLUORESCENCE DETECTION; MAGNETIC ACTUATION; MARKER PROTEINS; MICRO DEVICES; MICRO-FLUIDIC DEVICES; MICROBEADS; PROTEIN CONCENTRATIONS; SAMPLE RATE; SAMPLE VOLUME; SANDWICH IMMUNOASSAY; SERIAL PROCESSING; STREPTAVIDIN; SYSTEMIC INFLAMMATION; TIME VARYING;

EID: 77956268742     PISSN: 16134982     EISSN: 16134990     Source Type: Journal    
DOI: 10.1007/s10404-009-0543-1     Document Type: Article
Times cited : (36)

References (27)
  • 1
    • 36849044717 scopus 로고    scopus 로고
    • High-throughput automated luminescent magnetic particle- based immunoassay to monitor human exposure to pyrethroid insecticides
    • Ahn KC, Lohstroh P, Gee SJ, Gee NA, Lasley B, Hammock BD (2007) High-throughput automated luminescent magnetic particle- based immunoassay to monitor human exposure to pyrethroid insecticides. Anal Chem 79:8883-8890
    • (2007) Anal Chem , vol.79 , pp. 8883-8890
    • Ahn, K.C.1    Lohstroh, P.2    Gee, S.J.3    Gee, N.A.4    Lasley, B.5    Hammock, B.D.6
  • 2
    • 0036214593 scopus 로고    scopus 로고
    • A new reagentless immunosensor for measuring IgG concentration in human plasma based on fluorescence-enhancement immunoassay
    • Aoyagi S, Miyasaka T, Yoshimi Y, Sakai K (2002) A new reagentless immunosensor for measuring IgG concentration in human plasma based on fluorescence-enhancement immunoassay. Japn Soc Artif Organs 5:60-63
    • (2002) Japn Soc Artif Organs , vol.5 , pp. 60-63
    • Aoyagi, S.1    Miyasaka, T.2    Yoshimi, Y.3    Sakai, K.4
  • 3
    • 0034111716 scopus 로고    scopus 로고
    • Inflammatory response after coronary revascularization with or without cardiopulmonary bypass
    • DOI 10.1016/S0003-4975(00)01152-8, PII S0003497500011528
    • Ascione R, Lloyd CT, Underwood MJ, Lotto AA, Pitsis AA, Angelini GD (2000) Inflammatory response after coronary revascularization with or without cardiopulmonary bypass. Ann Thorac Surg 69:1198-1204 (Pubitemid 30259386)
    • (2000) Annals of Thoracic Surgery , vol.69 , Issue.4 , pp. 1198-1204
    • Ascione, R.1    Lloyd, C.T.2    Underwood, M.J.3    Lotto, A.A.4    Pitsis, A.A.5    Angelini, G.D.6
  • 4
    • 50049083053 scopus 로고    scopus 로고
    • Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol
    • Barton AC, Davis F, Higson SPJ (2008) Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol. Anal Chem 80:6198-6205
    • (2008) Anal Chem , vol.80 , pp. 6198-6205
    • Barton, A.C.1    Davis, F.2    Higson, S.P.J.3
  • 6
    • 34147141958 scopus 로고    scopus 로고
    • Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples
    • Bhattacharyya A, Klapperich CM (2007) Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples. Biomed Microdevices 9:245-251
    • (2007) Biomed Microdevices , vol.9 , pp. 245-251
    • Bhattacharyya, A.1    Klapperich, C.M.2
  • 9
    • 41149118562 scopus 로고    scopus 로고
    • A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities
    • Do J, Ahn CH (2008) A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities. Lab Chip 8:542-549
    • (2008) Lab Chip , vol.8 , pp. 542-549
    • Do, J.1    Ahn, C.H.2
  • 11
    • 33748791493 scopus 로고    scopus 로고
    • A label-free continuous total-internal-reflection-fluorescence-based immunosensor
    • Engstrom HA, Andersson PO, Ohlson S (2006) A label-free continuous total-internal-reflection-fluorescence-based immunosensor. Anal Biochem 357:159-166
    • (2006) Anal Biochem , vol.357 , pp. 159-166
    • Engstrom, H.A.1    Andersson, P.O.2    Ohlson, S.3
  • 12
    • 18744411773 scopus 로고    scopus 로고
    • Inhibition of complement neutrophil, and platelet activation by an anti-factor D monoclonal antibody insimulated cardiopulmonary bypass circuits
    • Fung M, Loubser PG, Undar A, Mueller M, Sun C, Sun WN, Vaughn WK, Fraser CD (2001) Inhibition of complement neutrophil, and platelet activation by an anti-factor D monoclonal antibody insimulated cardiopulmonary bypass circuits. J Thorac Cardiovasc Surg 122:113-122
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 113-122
    • Fung, M.1    Loubser, P.G.2    Undar, A.3    Mueller, M.4    Sun, C.5    Sun, W.N.6    Vaughn, W.K.7    Fraser, C.D.8
  • 13
    • 33645390387 scopus 로고    scopus 로고
    • Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA
    • Herrmann M, Veres T, Tabrizian M (2006) Enzymatically-generated fluorescent detection in micro-channels with internal magnetic mixing for the development of parallel microfluidic ELISA. Lab Chip 6:555-560
    • (2006) Lab Chip , vol.6 , pp. 555-560
    • Herrmann, M.1    Veres, T.2    Tabrizian, M.3
  • 15
    • 20844434014 scopus 로고    scopus 로고
    • Magnetic force-based multiplexed immunoassay using superparamagnetic nanoparticles in microfluidic channel
    • Kim KS, Park JK (2005) Magnetic force-based multiplexed immunoassay using superparamagnetic nanoparticles in microfluidic channel. Lab Chip 5:657-664
    • (2005) Lab Chip , vol.5 , pp. 657-664
    • Kim, K.S.1    Park, J.K.2
  • 16
    • 0001977226 scopus 로고
    • Hypothermia, circulatory arrest, and cardiopulmonary bypass
    • Kirklin JW, Barratt- Boyes BG (eds) . New York: Churchill Livingstone
    • Kirklin JW, Barratt-Boyes BG (1993) Hypothermia, circulatory arrest, and cardiopulmonary bypass. In: Kirklin JW, Barratt- Boyes BG (eds) Cardiac surgery. New York: Churchill Livingstone
    • (1993) Cardiac Surgery
    • Kirklin, J.W.1    Barratt-Boyes, B.G.2
  • 17
    • 0031838867 scopus 로고    scopus 로고
    • Complement activation and cytokine generation after modified Fontan procedure
    • Mainwaring RD, Lamberti JJ, Hugli TE (1998) Complement activation and cytokine generation after modified Fontan procedure. Ann Thorac Surg 65:1715-1720
    • (1998) Ann Thorac Surg , vol.65 , pp. 1715-1720
    • Mainwaring, R.D.1    Lamberti, J.J.2    Hugli, T.E.3
  • 18
    • 0023942152 scopus 로고
    • The effects of complement activation during cardiopulmonary bypass: Attenuation by hypothermia, heparin, and hemodilution
    • Moore FD, Warner KG, Assousa S (1988) The effects of complement activation during cardiopulmonary bypass: attenuation by hypothermia, heparin, and hemodilution. Ann Surg 208:95-103
    • (1988) Ann Surg , vol.208 , pp. 95-103
    • Moore, F.D.1    Warner, K.G.2    Assousa, S.3
  • 19
    • 33644835521 scopus 로고    scopus 로고
    • Magnetism and microfluidics
    • Pamme N (2006) Magnetism and microfluidics. Lab Chip 6:24-38
    • (2006) Lab Chip , vol.6 , pp. 24-38
    • Pamme, N.1
  • 20
    • 40149088939 scopus 로고    scopus 로고
    • Rapid on-chip multi-step (bio)chemical procedures in continuous flow-manoeuvring particles through co-laminar reagent streams
    • Peyman SA, Iles A, Pamme N (2008) Rapid on-chip multi-step (bio)chemical procedures in continuous flow-manoeuvring particles through co-laminar reagent streams. Chem Commun 1220-1222
    • (2008) Chem Commun , pp. 1220-1222
    • Peyman, S.A.1    Iles, A.2    Pamme, N.3
  • 21
    • 0141705557 scopus 로고    scopus 로고
    • Microfluidic chip for continuous monitoring of hormone secretion from live cells using an electrophoresis-based immunoassay
    • Roper MG, Shackman JG, Dahlgren GM, Kennedy RT (2003) Microfluidic chip for continuous monitoring of hormone secretion from live cells using an electrophoresis-based immunoassay. Anal Chem 75:4711-4717
    • (2003) Anal Chem , vol.75 , pp. 4711-4717
    • Roper, M.G.1    Shackman, J.G.2    Dahlgren, G.M.3    Kennedy, R.T.4
  • 22
    • 10644256733 scopus 로고    scopus 로고
    • Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection
    • Sato K, Yamanaka M, Hagino T, Tokeshi M, Kimura H, Kitamori T (2004) Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection. Lab Chip 4:570-575
    • (2004) Lab Chip , vol.4 , pp. 570-575
    • Sato, K.1    Yamanaka, M.2    Hagino, T.3    Tokeshi, M.4    Kimura, H.5    Kitamori, T.6
  • 24
    • 39549109280 scopus 로고    scopus 로고
    • Microfluidic immunosensor based on stable antibodypatterned surface in PMMA microchip
    • Wang HX, Meng S, Guo K, Liu Y, Yang PY, Zhong W, Liu BH (2008) Microfluidic immunosensor based on stable antibodypatterned surface in PMMA microchip. Electrochem Commun 10:447-450
    • (2008) Electrochem Commun , vol.10 , pp. 447-450
    • Wang, H.X.1    Meng, S.2    Guo, K.3    Liu, Y.4    Yang, P.Y.5    Zhong, W.6    Liu, B.H.7
  • 25
    • 0023149123 scopus 로고
    • Organ dysfunction after cardiopulmonary bypass: A systemic inflammatory reaction initiated by the extracorporeal circuit
    • Westaby S (1987) Organ dysfunction after cardiopulmonary bypass: a systemic inflammatory reaction initiated by the extracorporeal circuit. Intensive Care Med 13:89-95
    • (1987) Intensive Care Med , vol.13 , pp. 89-95
    • Westaby, S.1
  • 27
    • 34247884482 scopus 로고    scopus 로고
    • Continuous cytometric bead processing within a microfluidic device for bead based sensing platforms
    • Yang S, Undar A, Zahn JD (2007) Continuous cytometric bead processing within a microfluidic device for bead based sensing platforms. Lab Chip 7:588-595
    • (2007) Lab Chip , vol.7 , pp. 588-595
    • Yang, S.1    Undar, A.2    Zahn, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.