메뉴 건너뛰기




Volumn 25, Issue 8, 2011, Pages 408-429

A new third-order calibration method with application for analysis of four-way data arrays

Author keywords

AWRCQLD; Four way data arrays; Four way PARAFAC; Quadrilinear model; Second order calibration; Third order calibration

Indexed keywords

ALTERNATING WEIGHTED RESIDUE CONSTRAINT QUADRILINEAR DECOMPOSITION; DATA ARRAY; FOUR-WAY DATA ARRAY; FOUR-WAY PARAFAC; QUADRILINEAR; QUADRILINEAR MODEL; SECOND-ORDER CALIBRATION; THIRD ORDER; THIRD-ORDER CALIBRATION;

EID: 80051940257     PISSN: 08869383     EISSN: 1099128X     Source Type: Journal    
DOI: 10.1002/cem.1386     Document Type: Article
Times cited : (51)

References (55)
  • 1
    • 40449089446 scopus 로고    scopus 로고
    • Higher-order chemical sensing
    • Hierlemann A. Higher-order chemical sensing. Chem. Rev. 2008; 108: 563-613.
    • (2008) Chem. Rev. , vol.108 , pp. 563-613
    • Hierlemann, A.1
  • 3
    • 16244386226 scopus 로고    scopus 로고
    • Characterization band matching of oil samples using fluorescence spectroscopy and parallel factor analysis
    • Christensen JH, Hansen AB, Mortensen J, Andersen O. Characterization band matching of oil samples using fluorescence spectroscopy and parallel factor analysis. Anal. Chem. 2005; 77: 2210-2217.
    • (2005) Anal. Chem. , vol.77 , pp. 2210-2217
    • Christensen, J.H.1    Hansen, A.B.2    Mortensen, J.3    Andersen, O.4
  • 4
    • 12344268737 scopus 로고    scopus 로고
    • Three- and four-way parallel factor (PARAFAC) analysis of photochemically induced excitation-emission kinetic fluorescence spectra
    • Naborniak ML, Cooper GA, Kim YC, Booksh KS. Three- and four-way parallel factor (PARAFAC) analysis of photochemically induced excitation-emission kinetic fluorescence spectra. Analyst 2005; 130: 85-93.
    • (2005) Analyst , vol.130 , pp. 85-93
    • Naborniak, M.L.1    Cooper, G.A.2    Kim, Y.C.3    Booksh, K.S.4
  • 5
    • 1542345482 scopus 로고    scopus 로고
    • Blind spectral decomposition of single-cell fluorescence by parallel factor analysis
    • Shirakawa H, Miyazaki S. Blind spectral decomposition of single-cell fluorescence by parallel factor analysis. Biophys. J. 2004; 86: 1739-1752.
    • (2004) Biophys. J. , vol.86 , pp. 1739-1752
    • Shirakawa, H.1    Miyazaki, S.2
  • 6
    • 85152367458 scopus 로고
    • Tensorial calibration: II. Second-order calibration
    • Sanchez E, Kowalski BR. Tensorial calibration: II. Second-order calibration. J. Chemom. 1988; 2: 265-280.
    • (1988) J. Chemom. , vol.2 , pp. 265-280
    • Sanchez, E.1    Kowalski, B.R.2
  • 7
    • 0038218259 scopus 로고    scopus 로고
    • Practical aspects of PARAFAC modeling of fluorescence excitation-emission data
    • Andersen CM, Bro R. Practical aspects of PARAFAC modeling of fluorescence excitation-emission data. J. Chemom. 2003; 17: 200-215.
    • (2003) J. Chemom. , vol.17 , pp. 200-215
    • Andersen, C.M.1    Bro, R.2
  • 8
    • 0033653780 scopus 로고    scopus 로고
    • Application of PARAFAC for calibration with excitation-emission matrix fluorescence spectra of three classes of environmental pollutants
    • JiJi RD, Andersson GG, Booksh KS. Application of PARAFAC for calibration with excitation-emission matrix fluorescence spectra of three classes of environmental pollutants. J. Chemom. 2000; 14: 171-185.
    • (2000) J. Chemom. , vol.14 , pp. 171-185
    • JiJi, R.D.1    Andersson, G.G.2    Booksh, K.S.3
  • 9
    • 0001129840 scopus 로고
    • Multivariate curve resolution applied to spectral data from multiple runs of an industrial process
    • Tauler R, Kowalski BR, Fleming S. Multivariate curve resolution applied to spectral data from multiple runs of an industrial process. Anal. Chem. 1993; 65: 2040-2047.
    • (1993) Anal. Chem. , vol.65 , pp. 2040-2047
    • Tauler, R.1    Kowalski, B.R.2    Fleming, S.3
  • 10
    • 85164283474 scopus 로고
    • Recent developments in multivariate calibration
    • Kowalski BR, Seasholtz MB. Recent developments in multivariate calibration. J. Chemom. 1991; 5: 129-145.
    • (1991) J. Chemom. , vol.5 , pp. 129-145
    • Kowalski, B.R.1    Seasholtz, M.B.2
  • 12
    • 0032844771 scopus 로고    scopus 로고
    • Excitation-emission matrix fluorescence based determination of carbamate pesticides and polycyclic aromatic hydrocarbons
    • JiJi RD, Cooper GA, Booksh KS. Excitation-emission matrix fluorescence based determination of carbamate pesticides and polycyclic aromatic hydrocarbons. Anal. Chim. Acta 1999; 397: 61-72.
    • (1999) Anal. Chim. Acta , vol.397 , pp. 61-72
    • JiJi, R.D.1    Cooper, G.A.2    Booksh, K.S.3
  • 13
    • 2442694329 scopus 로고    scopus 로고
    • Determination of carbendazim, fuberidazole and thiabendazole by three dimensional excitation-emission matrix fluorescence and parallel factor analysis
    • Rodriguez-Cuesta MJ, Boque R, Rius FX, Zamora DP, Galera MM, Frenich AG. Determination of carbendazim, fuberidazole and thiabendazole by three dimensional excitation-emission matrix fluorescence and parallel factor analysis. Anal. Chim. Acta 2003; 491: 47-56.
    • (2003) Anal. Chim. Acta , vol.491 , pp. 47-56
    • Rodriguez-Cuesta, M.J.1    Boque, R.2    Rius, F.X.3    Zamora, D.P.4    Galera, M.M.5    Frenich, A.G.6
  • 14
    • 33846549506 scopus 로고    scopus 로고
    • Room-temperature excitation-emission phosphorescence matrices and second-order multivariate calibration for the simultaneous determination of pyrene and benzo[a]pyrene
    • Arancibia JA, Escandar GM. Room-temperature excitation-emission phosphorescence matrices and second-order multivariate calibration for the simultaneous determination of pyrene and benzo[a]pyrene. Anal. Chim. Acta 2007; 584: 287-294.
    • (2007) Anal. Chim. Acta , vol.584 , pp. 287-294
    • Arancibia, J.A.1    Escandar, G.M.2
  • 16
    • 0038039040 scopus 로고    scopus 로고
    • Spectrofluorimetric study of the β-cyclodextrin-ibuprofen complex and determination of ibuprofen in pharmaceutical preparations and serum
    • Hergert LA, Escandar GM. Spectrofluorimetric study of the β-cyclodextrin-ibuprofen complex and determination of ibuprofen in pharmaceutical preparations and serum. Talanta 2003; 60: 235-246.
    • (2003) Talanta , vol.60 , pp. 235-246
    • Hergert, L.A.1    Escandar, G.M.2
  • 17
    • 0141567822 scopus 로고    scopus 로고
    • Determination of doxorubicin in human plasma by excitation-emission matrix fluorescence and multi-way analysis
    • Trevisan MG, Poppi RJ. Determination of doxorubicin in human plasma by excitation-emission matrix fluorescence and multi-way analysis. Anal. Chim. Acta 2003; 493: 69-81.
    • (2003) Anal. Chim. Acta , vol.493 , pp. 69-81
    • Trevisan, M.G.1    Poppi, R.J.2
  • 18
    • 0038769300 scopus 로고    scopus 로고
    • Multivariate curve resolution of cyclic voltammetric data: application to the study of the cadmium-binding properties of glutathione
    • Diaz-Cruz MS, Mendieta J, Tauler R. Multivariate curve resolution of cyclic voltammetric data: application to the study of the cadmium-binding properties of glutathione. Anal. Chem. 1999; 20: 4629-4636.
    • (1999) Anal. Chem. , vol.20 , pp. 4629-4636
    • Diaz-Cruz, M.S.1    Mendieta, J.2    Tauler, R.3
  • 19
    • 2942726198 scopus 로고    scopus 로고
    • Application of unfold principal component analysis and parallel factor analysis to the exploratory analysis of olive oils by means of excitation-emission matrix fluorescence spectroscopy
    • Guimet F, Ferré J, Boqué R, Rius FX. Application of unfold principal component analysis and parallel factor analysis to the exploratory analysis of olive oils by means of excitation-emission matrix fluorescence spectroscopy. Anal. Chim. Acta 2004; 515: 75-85.
    • (2004) Anal. Chim. Acta , vol.515 , pp. 75-85
    • Guimet, F.1    Ferré, J.2    Boqué, R.3    Rius, F.X.4
  • 21
    • 1042279663 scopus 로고    scopus 로고
    • Optimizing the implementation of the PARAFAC method for near-real time calibration of excitation-emission fluorescence analysis
    • Nahorniak ML, Booksh KS. Optimizing the implementation of the PARAFAC method for near-real time calibration of excitation-emission fluorescence analysis. J. Chemom. 2003; 17: 608-617.
    • (2003) J. Chemom. , vol.17 , pp. 608-617
    • Nahorniak, M.L.1    Booksh, K.S.2
  • 22
    • 33750732044 scopus 로고    scopus 로고
    • Real-time monitoring and chemical profiling of a cultivation process
    • Mortensen PP, Bro R. Real-time monitoring and chemical profiling of a cultivation process. Chemom. Intell. Lab. Syst. 2006; 84: 106-113.
    • (2006) Chemom. Intell. Lab. Syst. , vol.84 , pp. 106-113
    • Mortensen, P.P.1    Bro, R.2
  • 23
    • 34147181151 scopus 로고    scopus 로고
    • Determination of pesticides and metabolites in wine by high performance liquid chromatography and second-order calibration methods
    • Braga JWB, Bottoli CBG, Jardim ICSF, Goicoechea HC, Olivieri AC, Poppi RJ. Determination of pesticides and metabolites in wine by high performance liquid chromatography and second-order calibration methods. J. Chromatogr. A 2007; 1148: 200-210.
    • (2007) J. Chromatogr. A , vol.1148 , pp. 200-210
    • Braga, J.W.B.1    Bottoli, C.B.G.2    Jardim, I.C.S.F.3    Goicoechea, H.C.4    Olivieri, A.C.5    Poppi, R.J.6
  • 24
    • 1042275655 scopus 로고    scopus 로고
    • Determination of carbamazepine in serum and pharmaceutical preparations using immobilization on nylon support and fluorescence detection
    • Escandar GM, González Gómez D, Espinosa Mansilla A, de la Peña AM, Goicoechea HC. Determination of carbamazepine in serum and pharmaceutical preparations using immobilization on nylon support and fluorescence detection. Anal. Chim. Acta 2004; 506: 161-170.
    • (2004) Anal. Chim. Acta , vol.506 , pp. 161-170
    • Escandar, G.M.1    González Gómez, D.2    Espinosa Mansilla, A.3    de la Peña, A.M.4    Goicoechea, H.C.5
  • 25
    • 26444570774 scopus 로고
    • Generalized rank annihilation factor analysis
    • Sanchez E, Kowalski BR. Generalized rank annihilation factor analysis. Anal. Chem. 1986; 58: 496-499.
    • (1986) Anal. Chem. , vol.58 , pp. 496-499
    • Sanchez, E.1    Kowalski, B.R.2
  • 26
    • 85153977149 scopus 로고
    • Foundations of the PARAFAC procedure: Models and conditions for an 'explanatory' multi-modal factor analysis. UCLA Working Papers in Phonetics. 16:
    • Harshman RA. Foundations of the PARAFAC procedure: Models and conditions for an 'explanatory' multi-modal factor analysis. UCLA Working Papers in Phonetics. 1970; 16: 1-84.
    • (1970) , pp. 1-84
    • Harshman, R.A.1
  • 27
    • 34250499792 scopus 로고
    • Analysis of individual differences in multidimensional scaling via an N-way generalization of 'Eckart-Young' decomposition
    • Carroll JD, Chang JJ. Analysis of individual differences in multidimensional scaling via an N-way generalization of 'Eckart-Young' decomposition. Psychometrika 1970; 35: 283-319.
    • (1970) Psychometrika , vol.35 , pp. 283-319
    • Carroll, J.D.1    Chang, J.J.2
  • 28
    • 0030813663 scopus 로고    scopus 로고
    • PARAFAC: tutorial and applications
    • Bro R. PARAFAC: tutorial and applications. Chemom. Intell. Lab. Syst. 1997; 38: 149-171.
    • (1997) Chemom. Intell. Lab. Syst. , vol.38 , pp. 149-171
    • Bro, R.1
  • 29
    • 0002017118 scopus 로고    scopus 로고
    • An alternating trilinear decomposition algorithm with application to calibration of HPLC-DAD for simultaneous determination of overlapped chlorinated aromatic hydrocarbons
    • Wu HL, Shibukawa M, Oguma KJ. An alternating trilinear decomposition algorithm with application to calibration of HPLC-DAD for simultaneous determination of overlapped chlorinated aromatic hydrocarbons. J. Chemom. 1998; 12: 1-26.
    • (1998) J. Chemom. , vol.12 , pp. 1-26
    • Wu, H.L.1    Shibukawa, M.2    Oguma, K.J.3
  • 30
    • 0034648456 scopus 로고    scopus 로고
    • A novel trilinear decomposition algorithm for second-order linear calibration
    • Chen ZP, Wu HL, Jiang JH, Li Y, Yu RQ. A novel trilinear decomposition algorithm for second-order linear calibration. Chemom. Intell. Lab. Syst. 2000; 52: 75-86.
    • (2000) Chemom. Intell. Lab. Syst. , vol.52 , pp. 75-86
    • Chen, Z.P.1    Wu, H.L.2    Jiang, J.H.3    Li, Y.4    Yu, R.Q.5
  • 31
    • 27644439099 scopus 로고    scopus 로고
    • Alternating penalty trilinear decomposition algorithm for second-order calibration with application to interference-free analysis of excitation-emission matrix fluorescence data
    • Xia AL, Wu HL, Fang DM, Ding YJ, Hu LQ, Yu RQ. Alternating penalty trilinear decomposition algorithm for second-order calibration with application to interference-free analysis of excitation-emission matrix fluorescence data. J. Chemom. 2005; 19: 65-76.
    • (2005) J. Chemom. , vol.19 , pp. 65-76
    • Xia, A.L.1    Wu, H.L.2    Fang, D.M.3    Ding, Y.J.4    Hu, L.Q.5    Yu, R.Q.6
  • 32
    • 69249113769 scopus 로고    scopus 로고
    • Multi-way chemometric methodologies and applications: A central summary of our research work
    • Wu HL, Nie JF, Yu YJ, Yu RQ. Multi-way chemometric methodologies and applications: A central summary of our research work. Anal. Chim. Acta 2009; 650: 131-142.
    • (2009) Anal. Chim. Acta , vol.650 , pp. 131-142
    • Wu, H.L.1    Nie, J.F.2    Yu, Y.J.3    Yu, R.Q.4
  • 33
    • 0033989620 scopus 로고    scopus 로고
    • Multivariate curve resolution with alternating least squares optimisation: a soft-modelling approach to metal complexation studies by voltammetric techniques
    • Esteban M, Arino C, Diaz-Cruz JN, Diaz-Cruz MS, Tauler R. Multivariate curve resolution with alternating least squares optimisation: a soft-modelling approach to metal complexation studies by voltammetric techniques. Trends Anal. Chem. 2000; 19: 49-61.
    • (2000) Trends Anal. Chem. , vol.19 , pp. 49-61
    • Esteban, M.1    Arino, C.2    Diaz-Cruz, J.N.3    Diaz-Cruz, M.S.4    Tauler, R.5
  • 34
    • 0032563583 scopus 로고    scopus 로고
    • Second-order calibration: bilinear least squares regression and a simple alternative
    • Linder M, Sundberg R. Second-order calibration: bilinear least squares regression and a simple alternative. Chemom. Intell. Lab. Syst. 1998; 42: 159-178.
    • (1998) Chemom. Intell. Lab. Syst. , vol.42 , pp. 159-178
    • Linder, M.1    Sundberg, R.2
  • 35
    • 0036157377 scopus 로고    scopus 로고
    • Precision of prediction in second-order calibration, with focus on bilinear regression methods
    • Linder M, Sundberg R. Precision of prediction in second-order calibration, with focus on bilinear regression methods. J. Chemom. 2002; 16: 12-27.
    • (2002) J. Chemom. , vol.16 , pp. 12-27
    • Linder, M.1    Sundberg, R.2
  • 36
    • 0037190315 scopus 로고    scopus 로고
    • Second-order bilinear calibration: the effects of vectorising the data matrices for the calibration set
    • Faber NM, Ferré J, Boqué R, Kalivas JH. Second-order bilinear calibration: the effects of vectorising the data matrices for the calibration set. Chemom. Intell. Lab. Syst. 2002; 63: 107-116.
    • (2002) Chemom. Intell. Lab. Syst. , vol.63 , pp. 107-116
    • Faber, N.M.1    Ferré, J.2    Boqué, R.3    Kalivas, J.H.4
  • 37
    • 31344478850 scopus 로고    scopus 로고
    • On a versatile second-order multivariate calibration method based on partial least-squares and residual bilinearization: Second-order advantage and precision properties
    • Olivieri AC. On a versatile second-order multivariate calibration method based on partial least-squares and residual bilinearization: Second-order advantage and precision properties. J. Chemom. 2005; 19: 253-265.
    • (2005) J. Chemom. , vol.19 , pp. 253-265
    • Olivieri, A.C.1
  • 38
    • 34548785510 scopus 로고    scopus 로고
    • Alternating penalty quadrilinear decomposition algorithm for an analysis of four-way data arrays
    • Xia AL, Wu HL, Li SF, Zhu SH, Hu LQ, Yu RQ. Alternating penalty quadrilinear decomposition algorithm for an analysis of four-way data arrays. J. Chemom. 2007; 21: 133-144.
    • (2007) J. Chemom. , vol.21 , pp. 133-144
    • Xia, A.L.1    Wu, H.L.2    Li, S.F.3    Zhu, S.H.4    Hu, L.Q.5    Yu, R.Q.6
  • 39
    • 57049147403 scopus 로고    scopus 로고
    • Fluorescence quantification of tetracycline in the presence of quenching matrix effect by means of a four-way model
    • Rodríguez N, Ortiz MC, Sarabia LA. Fluorescence quantification of tetracycline in the presence of quenching matrix effect by means of a four-way model. Talanta 2009; 77: 1129-1136.
    • (2009) Talanta , vol.77 , pp. 1129-1136
    • Rodríguez, N.1    Ortiz, M.C.2    Sarabia, L.A.3
  • 40
    • 69249122187 scopus 로고    scopus 로고
    • Error analysis of second-order standarad addttion method by Monte carrol simulation
    • Long N, Wu HL. Error analysis of second-order standarad addttion method by Monte carrol simulation. Chem. Anal. Meterage 2004; 13: 18-21.
    • (2004) Chem. Anal. Meterage , vol.13 , pp. 18-21
    • Long, N.1    Wu, H.L.2
  • 41
    • 34548476935 scopus 로고    scopus 로고
    • Study of the interactions of berberine and daunorubicin with DNA using alternating penalty trilinear decomposition algorithm combined with excitation-emission matrix fluorescence data
    • Xia AL, Wu HL, Li SF, Zhu SH, Zhang Y, Han QJ, Yu RQ. Study of the interactions of berberine and daunorubicin with DNA using alternating penalty trilinear decomposition algorithm combined with excitation-emission matrix fluorescence data. Talanta 2007; 73: 606-612.
    • (2007) Talanta , vol.73 , pp. 606-612
    • Xia, A.L.1    Wu, H.L.2    Li, S.F.3    Zhu, S.H.4    Zhang, Y.5    Han, Q.J.6    Yu, R.Q.7
  • 44
    • 17644423181 scopus 로고    scopus 로고
    • Four-way data coupled to parallel factor model applied to environmental analysis: determination of 2, 3 7, 8-tetrachloro-dibenzo-para-dioxin in highly contaminated waters by solid-liquid extraction laser-excited time-resolved Shpol'skii spectroscopy
    • Goicoechea HC, Yu SJ, Olivieri AC, Campiglia AD. Four-way data coupled to parallel factor model applied to environmental analysis: determination of 2, 3 7, 8-tetrachloro-dibenzo-para-dioxin in highly contaminated waters by solid-liquid extraction laser-excited time-resolved Shpol'skii spectroscopy. Anal. Chem. 2005; 77: 2608-2616.
    • (2005) Anal. Chem. , vol.77 , pp. 2608-2616
    • Goicoechea, H.C.1    Yu, S.J.2    Olivieri, A.C.3    Campiglia, A.D.4
  • 45
    • 34248324815 scopus 로고    scopus 로고
    • Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples
    • de la Peña AM, Durán-Merás I, Merás ID, Jiménez-Girón A, Durán-Merás I. Evaluation of unfolded-partial least-squares coupled to residual trilinearization for four-way calibration of folic acid and methotrexate in human serum samples. Talanta 2007; 72: 1261-1268.
    • (2007) Talanta , vol.72 , pp. 1261-1268
    • de la Peña, A.M.1    Durán-Merás, I.2    Merás, I.D.3    Jiménez-Girón, A.4    Durán-Merás, I.5
  • 46
    • 33746837634 scopus 로고    scopus 로고
    • Analysis of four-way two-dimensional liquid chromatography-diode array data: application to metabolomics
    • Porter SEG, Stoll DR, Rutan SC, Carr PW, Cohen JD. Analysis of four-way two-dimensional liquid chromatography-diode array data: application to metabolomics. Anal. Chem. 2006; 78: 5559-5569.
    • (2006) Anal. Chem. , vol.78 , pp. 5559-5569
    • Porter, S.E.G.1    Stoll, D.R.2    Rutan, S.C.3    Carr, P.W.4    Cohen, J.D.5
  • 47
    • 4744337717 scopus 로고    scopus 로고
    • Second-order advantage achieved with four-way fluorescence excitation-emission-kinetic data processed by parallel factor analysis and trilinear least-squares. determination of methotrexate and leucovorin in human urine
    • Olivieri AC, Arancibia JA, de la Peña AM, Durán-Merás I, Espinosa-Mansilla A. Second-order advantage achieved with four-way fluorescence excitation-emission-kinetic data processed by parallel factor analysis and trilinear least-squares. determination of methotrexate and leucovorin in human urine. Anal. Chem. 2004; 76: 5657-5666.
    • (2004) Anal. Chem. , vol.76 , pp. 5657-5666
    • Olivieri, A.C.1    Arancibia, J.A.2    de la Peña, A.M.3    Durán-Merás, I.4    Espinosa-Mansilla, A.5
  • 48
    • 58149503963 scopus 로고    scopus 로고
    • Excitation-emission-kinetic fluorescence coupled with third-order calibration for quantifying carbaryl and investigating the hydrolysis in effluent water
    • Zhu SH, Wu HL, Xia AL, Nie JF, Bian YC, Cai CB, Yu RQ. Excitation-emission-kinetic fluorescence coupled with third-order calibration for quantifying carbaryl and investigating the hydrolysis in effluent water. Talanta 2009; 77: 1640-1646.
    • (2009) Talanta , vol.77 , pp. 1640-1646
    • Zhu, S.H.1    Wu, H.L.2    Xia, A.L.3    Nie, J.F.4    Bian, Y.C.5    Cai, C.B.6    Yu, R.Q.7
  • 49
    • 46049106321 scopus 로고    scopus 로고
    • On line photochemically induced excitation-emission-kinetic four-way data: Analytical application for the determination of folic acid and its two main metabolites in serum by U-PLS and N-PLS/residual trilinearization (RTL) calibration
    • Jiménez-Girón A, Durán-Merás I, Espinosa-Mansilla A, de la Peña AM, Cañada Cañada F. On line photochemically induced excitation-emission-kinetic four-way data: Analytical application for the determination of folic acid and its two main metabolites in serum by U-PLS and N-PLS/residual trilinearization (RTL) calibration. Anal. Chim. Acta 2008; 622: 94-103.
    • (2008) Anal. Chim. Acta , vol.622 , pp. 94-103
    • Jiménez-Girón, A.1    Durán-Merás, I.2    Espinosa-Mansilla, A.3    de la Peña, A.M.4    Cañada Cañada, F.5
  • 50
    • 34548783830 scopus 로고    scopus 로고
    • Multiway partial least-squares coupled to residual trilinearization: a genuine multidimensional tool for the study of third-order data. Simultaneous analysis of procaine and its metabolite p-aminobenzoic acid in equine serum
    • Damiani PC, Durán-Merás I, García-Reiriz A, Jiménez-Girón A, de la Peña AM, Olivieri AC. Multiway partial least-squares coupled to residual trilinearization: a genuine multidimensional tool for the study of third-order data. Simultaneous analysis of procaine and its metabolite p-aminobenzoic acid in equine serum. Anal. Chem. 2007; 79: 6949-6958.
    • (2007) Anal. Chem. , vol.79 , pp. 6949-6958
    • Damiani, P.C.1    Durán-Merás, I.2    García-Reiriz, A.3    Jiménez-Girón, A.4    de la Peña, A.M.5    Olivieri, A.C.6
  • 51
    • 49449099440 scopus 로고    scopus 로고
    • Analytical advantages of multivariate data processing. one, two, three, infinity?
    • Olivieri AC. Analytical advantages of multivariate data processing. one, two, three, infinity? Anal. Chem. 2008; 80: 5713-5720.
    • (2008) Anal. Chem. , vol.80 , pp. 5713-5720
    • Olivieri, A.C.1
  • 52
    • 0036083440 scopus 로고    scopus 로고
    • 'Stretch' vs 'slice' methods for representing three-way structure via matrix notation
    • Harshamn RA, Hong SJ. 'Stretch' vs 'slice' methods for representing three-way structure via matrix notation. J. Chemom. 2002; 16: 198-205.
    • (2002) J. Chemom. , vol.16 , pp. 198-205
    • Harshamn, R.A.1    Hong, S.J.2
  • 53
    • 48749101457 scopus 로고
    • Three-way arrays: rank and uniqueness of trilinear decompositions, with application to arithmetic complexity and statistics
    • Kruskal JB. Three-way arrays: rank and uniqueness of trilinear decompositions, with application to arithmetic complexity and statistics. Linear Algebra Appl. 1977; 18: 95-138.
    • (1977) Linear Algebra Appl. , vol.18 , pp. 95-138
    • Kruskal, J.B.1
  • 54
    • 0000930833 scopus 로고
    • More factors than subjects, tests and treatments: an indeterminacy theorem for canonical decomposition and individual differences scaling
    • Kruskal JB. More factors than subjects, tests and treatments: an indeterminacy theorem for canonical decomposition and individual differences scaling. Psychometrika 1976; 41: 281-293.
    • (1976) Psychometrika , vol.41 , pp. 281-293
    • Kruskal, J.B.1
  • 55
    • 0030775193 scopus 로고    scopus 로고
    • A weighted non-negative least squares algorithm for three-way 'PARAFAC' factor analysis
    • Paatro P. A weighted non-negative least squares algorithm for three-way 'PARAFAC' factor analysis. Chemom. Intell. Lab. Syst. 1997; 38: 223-242.
    • (1997) Chemom. Intell. Lab. Syst. , vol.38 , pp. 223-242
    • Paatro, P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.