메뉴 건너뛰기




Volumn 107, Issue 3, 2011, Pages 336-343

Cardiac output can be measured with the transpulmonary thermodilution method in a paediatric animal model with a left-to-right shunt

Author keywords

cardiac output; children; fluid therapy; haemodynamics; hypovolemic shock; left to right shunt; monitoring; thermodilution

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; HEART LEFT RIGHT SHUNT; HEART OUTPUT; HEMODYNAMICS; LAMB; MEASUREMENT; NONHUMAN; PRIORITY JOURNAL; PULMONARY ARTERY; THERMODILUTION; TRANSPULMONARY THERMODILUTION;

EID: 80051751292     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aer127     Document Type: Article
Times cited : (15)

References (27)
  • 3
    • 77950341804 scopus 로고    scopus 로고
    • Clinical monitoring of systemic hemodynamics in critically ill newborns
    • de Boode WP. Clinical monitoring of systemic hemodynamics in critically ill newborns. Early Hum Dev 2010;86:137-41
    • (2010) Early Hum Dev , vol.86 , pp. 137-141
    • De Boode, W.P.1
  • 4
    • 0030696028 scopus 로고    scopus 로고
    • Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants
    • DOI 10.1007/s001340050443
    • Tibby SM, Hatherill M, Marsh MJ, Morrison G, Anderson D, Murdoch IA. Clinical validation of cardiac output measurements using femoral artery thermodilution with direct Fick in ventilated children and infants. Intensive Care Med 1997;23:987-91 (Pubitemid 27464708)
    • (1997) Intensive Care Medicine , vol.23 , Issue.9 , pp. 987-991
    • Tibby, S.M.1    Hatherill, M.2    Marsh, M.J.3    Morrison, G.4    Anderson, D.5    Murdoch, I.A.6
  • 5
    • 0036020297 scopus 로고    scopus 로고
    • Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle
    • DOI 10.1007/s00134-002-1334-2
    • Pauli C, Fakler U, Genz T, Hennig M, Lorenz HP, Hess J. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Intensive Care Med 2002;28:947-52 (Pubitemid 34762232)
    • (2002) Intensive Care Medicine , vol.28 , Issue.7 , pp. 947-952
    • Pauli, C.1    Fakler, U.2    Genz, T.3    Hennig, M.4    Lorenz, H.-P.5    Hess, J.6
  • 6
    • 43549092418 scopus 로고    scopus 로고
    • Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
    • DOI 10.1097/PCC.0b013e31816c6fa1
    • Lemson J, de Boode WP, Hopman JC, Singh SK, van der Hoeven JG. Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model. Pediatr Crit Care Med 2008;9:313-9 (Pubitemid 351677672)
    • (2008) Pediatric Critical Care Medicine , vol.9 , Issue.3 , pp. 313-319
    • Lemson, J.1    De Boode, W.P.2    Hopman, J.C.W.3    Singh, S.K.4    Van Der Hoeven, J.G.5
  • 7
    • 43549103778 scopus 로고    scopus 로고
    • Transpulmonary thermodilution: Finally, a gold standard for pediatric cardiac output measurement
    • DOI 10.1097/PCC.0b013e318172ea56
    • Tibby S. Transpulmonary thermodilution: finally, a gold standard for pediatric cardiac output measurement. Pediatr Crit Care Med 2008;9:341-2 (Pubitemid 351677688)
    • (2008) Pediatric Critical Care Medicine , vol.9 , Issue.3 , pp. 341-342
    • Tibby, S.1
  • 8
    • 0020695838 scopus 로고
    • Measurement of systemic and pulmonary blood flow and QP/QS ratio using Doppler and two-dimensional echocardiography
    • DOI 10.1016/S0002-9149(83)80172-6
    • Sanders SP, Yeager S, Williams RG. Measurement of systemic and pulmonary blood flow and QP/QS ratio using Doppler and twodimensional echocardiography. Am J Cardiol 1983;51:952-6 (Pubitemid 13154254)
    • (1983) American Journal of Cardiology , vol.51 , Issue.6 , pp. 952-956
    • Sanders, S.P.1    Yeager, S.2    Williams, R.G.3
  • 10
    • 0028923163 scopus 로고
    • Comparison of four Doppler echocardiographic methods for calculating pulmonary-to-systemic shunt flow ratios in patients with ventricular septal defect
    • Sabry AF, Reller MD, Silberbach GM, Rice MJ, Sahn DJ. Comparison of four Doppler echocardiographic methods for calculating pulmonary-to-systemic shunt flow ratios in patients with ventricular septal defect. Am J Cardiol 1995;75:611-4
    • (1995) Am J Cardiol , vol.75 , pp. 611-614
    • Sabry, A.F.1    Reller, M.D.2    Silberbach, G.M.3    Rice, M.J.4    Sahn, D.J.5
  • 11
    • 70149107834 scopus 로고    scopus 로고
    • Pulse densitometer indocyanine green dilution curves: A simple applicable and accurate method for determination of cardiac shunts
    • Bergstra A, Hoendermis ES, Talsma MD, Mook GA, Zijlstra WG, Berger RM. Pulse densitometer indocyanine green dilution curves: a simple applicable and accurate method for determination of cardiac shunts. Congenit Heart Dis 2009;4:362-8
    • (2009) Congenit Heart Dis , vol.4 , pp. 362-368
    • Bergstra, A.1    Hoendermis, E.S.2    Talsma, M.D.3    Mook, G.A.4    Zijlstra, W.G.5    Berger, R.M.6
  • 12
    • 0028870457 scopus 로고
    • Oximetric versus indicator dilution techniques for quantitating intracardiac left-to-right shunting in adults
    • Daniel WC, Lange RA, Willard JE, Landau C, Hillis LD. Oximetric versus indicator dilution techniques for quantitating intracardiac left-to-right shunting in adults. Am J Cardiol 1995;75:199-200
    • (1995) Am J Cardiol , vol.75 , pp. 199-200
    • Daniel, W.C.1    Lange, R.A.2    Willard, J.E.3    Landau, C.4    Hillis, L.D.5
  • 13
    • 33749361136 scopus 로고    scopus 로고
    • Assessment of shunt volumes in children with ventricular septal defects: Comparative quantification of MR flow measurements and invasive oximetry
    • DOI 10.1007/s00392-006-0415-6
    • Esmaeili A, Hohn R, Koch A, Vogl TJ, Hofstetter R, Abolmaali N. Assessment of shunt volumes in children with ventricular septal defects: comparative quantification of MR flow measurements and invasive oximetry. Clin Res Cardiol 2006;95:523-30 (Pubitemid 44496716)
    • (2006) Clinical Research in Cardiology , vol.95 , Issue.10 , pp. 523-530
    • Esmaeili, A.1    Hohn, R.2    Koch, A.3    Vogl, T.J.4    Hofstetter, R.5    Abolmaali, N.6
  • 15
    • 2142694343 scopus 로고    scopus 로고
    • Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: A validation study
    • DOI 10.1161/01.CIR.0000126494.66859.A2
    • Korperich H, Gieseke J, Barth P, et al. Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study. Circulation 2004;109:1987-93 (Pubitemid 38544489)
    • (2004) Circulation , vol.109 , Issue.16 , pp. 1987-1993
    • Korperich, H.1    Gieseke, J.2    Barth, P.3    Hoogeveen, R.4    Esdorn, H.5    Peterschroder, A.6    Meyer, H.7    Beerbaum, P.8
  • 16
    • 0000606319 scopus 로고
    • Theoretical basis of indicator-dilution methods for measuring flow and volume
    • Zierler KL. Theoretical basis of indicator-dilution methods for measuring flow and volume. Circ Res 1962;10:393-407
    • (1962) Circ Res , vol.10 , pp. 393-407
    • Zierler, K.L.1
  • 17
    • 33745468065 scopus 로고    scopus 로고
    • The "cross-talk phenomenon" in transpulmonary thermodilution is flow dependent [4]
    • DOI 10.1007/s00134-006-0162-1
    • Lemson J, Eijk RJ, van der Hoeven JG. The "cross-talk phenomenon" in transpulmonary thermodilution is flow dependent. Intensive Care Med 2006;32:1092 (Pubitemid 43952731)
    • (2006) Intensive Care Medicine , vol.32 , Issue.7 , pp. 1092
    • Lemson, J.1    Eijk, R.J.R.2    Van Der Hoeven, J.G.3
  • 18
    • 4143058080 scopus 로고    scopus 로고
    • Looking at transpulmonary thermodilution curves: The cross-talk phenomenon [5]
    • Michard F. Looking at transpulmonary thermodilution curves: the cross-talk phenomenon. Chest 2004;126:656-7 (Pubitemid 39093462)
    • (2004) Chest , vol.126 , Issue.2 , pp. 656-657
    • Michard, F.1
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999;15:85-91 (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 21
    • 2442477355 scopus 로고    scopus 로고
    • Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology
    • DOI 10.1111/j.1399-6576.2004.00375.x
    • Breukers RB, Jansen JR. Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology. Acta Anaesthesiol Scand 2004;48:658-61 (Pubitemid 38649601)
    • (2004) Acta Anaesthesiologica Scandinavica , vol.48 , Issue.5 , pp. 658-661
    • Breukers, R.B.G.E.1    Jansen, J.R.C.2
  • 23
    • 0015422027 scopus 로고
    • Thermal dilution measurement of pulmonary and systemic blood flow in secundum atrial septal defect, and transposition of great arteries with intact interventricular septum
    • Silove ED, Tynan MJ, Simcha AJ. Thermal dilution measurement of pulmonary and systemic blood flow in secundum atrial septal defect, and transposition of great arteries with intact interventricular septum. Br Heart J 1972;34:1142-6
    • (1972) Br Heart J , vol.34 , pp. 1142-1146
    • Silove, E.D.1    Tynan, M.J.2    Simcha, A.J.3
  • 24
    • 0009718351 scopus 로고
    • Indicator-dilution curves in acyanotic congenital heart disease
    • Broadbent JC, Wood EH. Indicator-dilution curves in acyanotic congenital heart disease. Circulation 1954;9:890-902
    • (1954) Circulation , vol.9 , pp. 890-902
    • Broadbent, J.C.1    Wood, E.H.2
  • 25
  • 26
    • 70049089878 scopus 로고    scopus 로고
    • Cardiac output measurement in ventilated lambs with a significant left-to-right shunt using the modified carbon dioxide fick method
    • de Boode WP, Hopman JC, Wijnen MH, Tanke RB, van der Hoeven HG, Liem KD. Cardiac output measurement in ventilated lambs with a significant left-to-right shunt using the modified carbon dioxide fick method. Neonatology 2010;97:124-31
    • (2010) Neonatology , vol.97 , pp. 124-131
    • De Boode, W.P.1    Hopman, J.C.2    Wijnen, M.H.3    Tanke, R.B.4    Van Der Hoeven, H.G.5    Liem, K.D.6
  • 27
    • 51049119395 scopus 로고    scopus 로고
    • Continuous, noninvasive techniques to determine cardiac output in children after cardiac surgery: Evaluation of transesophageal Doppler and electric velocimetry
    • Schubert S, Schmitz T, Weiss M, et al. Continuous, noninvasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry. J Clin Monit Comput 2008;22:299-307
    • (2008) J Clin Monit Comput , vol.22 , pp. 299-307
    • Schubert, S.1    Schmitz, T.2    Weiss, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.