메뉴 건너뛰기




Volumn 104, Issue 1, 2005, Pages 25-31

Echocardiographic automated cardiac output measurement of pulmonary output and quantification of intracardiac shunt

Author keywords

Cardiac output; Echocardiography; Intracardiac shunt

Indexed keywords

ACCURACY; ADULT; AORTA; ARTICLE; AUTOMATION; CALCULATION; CLINICAL PRACTICE; CONTROLLED STUDY; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DOPPLER ECHOCARDIOGRAPHY; EVALUATION; FEASIBILITY STUDY; FLOW RATE; HEART OUTPUT; HEART SEPTUM DEFECT; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MEASUREMENT; OXIMETRY; PRIORITY JOURNAL; PULMONARY ARTERY; PULSE WAVE; QUANTITATIVE ANALYSIS; RELIABILITY; SENSITIVITY AND SPECIFICITY; THERMODILUTION;

EID: 24044499985     PISSN: 01675273     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijcard.2004.09.012     Document Type: Article
Times cited : (12)

References (28)
  • 1
    • 0023902190 scopus 로고
    • Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect
    • H. Dittmann, R. Jacksch, W. Voelker, K.R. Karsch, and L. Seipel Accuracy of Doppler echocardiography in quantification of left to right shunts in adult patients with atrial septal defect J Am Coll Cardiol 11 1988 338 432
    • (1988) J Am Coll Cardiol , vol.11 , pp. 338-432
    • Dittmann, H.1    Jacksch, R.2    Voelker, W.3    Karsch, K.R.4    Seipel, L.5
  • 2
    • 0023687321 scopus 로고
    • Doppler color-flow imaging assessment of shunt size in atrial septal defect
    • C. Pollick, H. Sullivan, B. Cujec, and S. Wilansky Doppler color-flow imaging assessment of shunt size in atrial septal defect Circulation 78 1988 522 528
    • (1988) Circulation , vol.78 , pp. 522-528
    • Pollick, C.1    Sullivan, H.2    Cujec, B.3    Wilansky, S.4
  • 3
    • 0020526287 scopus 로고
    • Sensitivity of two-dimensional echocardiography in the direct visualization of atrial septal defect utilizing the subcostal approach: Experience with 154 patients
    • C. Shub, I.N. Dimopoulos, J.B. Seward, J.A. Callahan, R.G. Tancredi, and T.T. Schattenberg Sensitivity of two-dimensional echocardiography in the direct visualization of atrial septal defect utilizing the subcostal approach: experience with 154 patients J Am Coll Cardiol 2 1983 127 135
    • (1983) J Am Coll Cardiol , vol.2 , pp. 127-135
    • Shub, C.1    Dimopoulos, I.N.2    Seward, J.B.3    Callahan, J.A.4    Tancredi, R.G.5    Schattenberg, T.T.6
  • 4
    • 0020538331 scopus 로고
    • Classification of the site of ventricular septal defect by 2-dimensional echocardiography
    • H. Capelli, J.L. Andrade, and J. Somerville Classification of the site of ventricular septal defect by 2-dimensional echocardiography Am J Cardiol 51 1983 1474 1480
    • (1983) Am J Cardiol , vol.51 , pp. 1474-1480
    • Capelli, H.1    Andrade, J.L.2    Somerville, J.3
  • 5
    • 0022500634 scopus 로고
    • Continuous-wave Doppler in children with ventricular septal defect: Noninvasive estimation of interventricular pressure gradient
    • D.J. Murphy Jr., A. Ludomirsky, and J.C. Huhta Continuous-wave Doppler in children with ventricular septal defect: noninvasive estimation of interventricular pressure gradient Am J Cardiol 57 1986 428 432
    • (1986) Am J Cardiol , vol.57 , pp. 428-432
    • Murphy Jr., D.J.1    Ludomirsky, A.2    Huhta, J.C.3
  • 6
    • 0021884770 scopus 로고
    • Localisation of ventricular septal defects by simultaneous display of superimposed colour Doppler and cross sectional echocardiographic images
    • E. Ortiz, P.J. Robinson, J.E. Deanfield, R. Franklin, F.J. Macartney, and R.K. Wyse Localisation of ventricular septal defects by simultaneous display of superimposed colour Doppler and cross sectional echocardiographic images Br Heart J 54 1985 53 60
    • (1985) Br Heart J , vol.54 , pp. 53-60
    • Ortiz, E.1    Robinson, P.J.2    Deanfield, J.E.3    Franklin, R.4    MacArtney, F.J.5    Wyse, R.K.6
  • 7
    • 0020402993 scopus 로고
    • Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis
    • S.J. Goldberg, D.J. Sahn, H.D. Allen, L.M. Valdes-Cruz, H. Hoenecke, and Y. Carnahan Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis Am J Cardiol 50 1982 1394 1400
    • (1982) Am J Cardiol , vol.50 , pp. 1394-1400
    • Goldberg, S.J.1    Sahn, D.J.2    Allen, H.D.3    Valdes-Cruz, L.M.4    Hoenecke, H.5    Carnahan, Y.6
  • 8
    • 0022366726 scopus 로고
    • Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: Impact on quantitative Doppler flow calculations
    • W.J. Stewart, L. Jiang, R. Mich, N. Pandian, J.L. Guerrero, and A.E. Weyman Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: impact on quantitative Doppler flow calculations J Am Coll Cardiol 6 1985 653 662
    • (1985) J Am Coll Cardiol , vol.6 , pp. 653-662
    • Stewart, W.J.1    Jiang, L.2    Mich, R.3    Pandian, N.4    Guerrero, J.L.5    Weyman, A.E.6
  • 9
    • 0022202962 scopus 로고
    • The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output
    • A.J. Labovitz, T.A. Buckingham, and K. Habermehl The effects of sampling site on the two-dimensional echo-Doppler determination of cardiac output Am Heart J 109 1985 327 332
    • (1985) Am Heart J , vol.109 , pp. 327-332
    • Labovitz, A.J.1    Buckingham, T.A.2    Habermehl, K.3
  • 10
    • 0023625744 scopus 로고
    • Doppler estimation of cardiac output: Principles and pitfalls
    • G.A. Williams, and A.J. Labovitz Doppler estimation of cardiac output: principles and pitfalls Echocardiography 4 1987 355 374
    • (1987) Echocardiography , vol.4 , pp. 355-374
    • Williams, G.A.1    Labovitz, A.J.2
  • 11
    • 8044260000 scopus 로고    scopus 로고
    • Automated cardiac output measurement by spatiotemporal integration of color Doppler data. in vitro and clinical validation
    • J.P. Sun, M. Pu, F.M. Fouad, R. Christian, W.J. Stewart, and J.D. Thomas Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation Circulation 95 1997 932 939
    • (1997) Circulation , vol.95 , pp. 932-939
    • Sun, J.P.1    Pu, M.2    Fouad, F.M.3    Christian, R.4    Stewart, W.J.5    Thomas, J.D.6
  • 12
    • 0031751172 scopus 로고    scopus 로고
    • Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: An in vitro study
    • S. Aida, T. Shiota, H. Tsujino, and D.J. Sahn Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: an in vitro study J Am Soc Echocardiogr 11 1998 874 881
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 874-881
    • Aida, S.1    Shiota, T.2    Tsujino, H.3    Sahn, D.J.4
  • 13
    • 0031909375 scopus 로고    scopus 로고
    • A method for estimating aortic regurgitant effective orifice area by digital Doppler color flow mapping
    • M. Chikada, T. Shiota, S. Aida, I. Yamada, D.J. Sahn, and M. Jones A method for estimating aortic regurgitant effective orifice area by digital Doppler color flow mapping J Heart Valve Dis 7 1998 102 107
    • (1998) J Heart Valve Dis , vol.7 , pp. 102-107
    • Chikada, M.1    Shiota, T.2    Aida, S.3    Yamada, I.4    Sahn, D.J.5    Jones, M.6
  • 14
    • 0036839645 scopus 로고    scopus 로고
    • Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation
    • Y. Miyake, T. Hozumi, I. Mori, K. Sugioka, A. Yamamuro, and T. Akasaka Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation Heart 88 2002 481 484
    • (2002) Heart , vol.88 , pp. 481-484
    • Miyake, Y.1    Hozumi, T.2    Mori, I.3    Sugioka, K.4    Yamamuro, A.5    Akasaka, T.6
  • 15
    • 0032190619 scopus 로고    scopus 로고
    • Quantification of mitral regurgitation by automated cardiac output measurement: Experimental and clinical validation
    • J.P. Sun, X.S. Yang, J.X. Qin, N.L. Greenberg, J. Zhou, and C.J. Vazquez Quantification of mitral regurgitation by automated cardiac output measurement: experimental and clinical validation J Am Coll Cardiol 32 1998 1074 1082
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1074-1082
    • Sun, J.P.1    Yang, X.S.2    Qin, J.X.3    Greenberg, N.L.4    Zhou, J.5    Vazquez, C.J.6
  • 16
    • 0028857859 scopus 로고
    • Selection and treatment of candidates for heart transplantation. a statement for health professionals from the Committee on Heart Failure and Cardiac Transplantation of the Council on Clinical Cardiology, American Heart Association
    • M.R. Costanzo, S. Augustine, R. Bourge, M. Bristow, J.B. O'Connell, and D. Driscoll Selection and treatment of candidates for heart transplantation. A statement for health professionals from the Committee on Heart Failure and Cardiac Transplantation of the Council on Clinical Cardiology, American Heart Association Circulation 92 1995 3593 3612
    • (1995) Circulation , vol.92 , pp. 3593-3612
    • Costanzo, M.R.1    Augustine, S.2    Bourge, R.3    Bristow, M.4    O'Connell, J.B.5    Driscoll, D.6
  • 17
    • 0027973886 scopus 로고
    • Guidelines for evaluation and management of common congenital cardiac problems in infants, children, and adolescents. a statement for healthcare professionals from the Committee on Congenital Cardiac Defects of the Council on Cardiovascular Disease in the Young American Heart Association
    • D. Driscoll, H.D. Allen, D.L. Atkins, J. Brenner, A. Dunnigan, and W. Franklin Guidelines for evaluation and management of common congenital cardiac problems in infants, children, and adolescents. A statement for healthcare professionals from the Committee on Congenital Cardiac Defects of the Council on Cardiovascular Disease in the Young American Heart Association Circulation 90 1994 2180 2188
    • (1994) Circulation , vol.90 , pp. 2180-2188
    • Driscoll, D.1    Allen, H.D.2    Atkins, D.L.3    Brenner, J.4    Dunnigan, A.5    Franklin, W.6
  • 19
    • 0029362422 scopus 로고
    • Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method
    • H. Tsujino, E. Shiki, M. Hirama, and K. Iinuma Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method J Am Soc Echocardiogr 8 1995 621 630
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 621-630
    • Tsujino, H.1    Shiki, E.2    Hirama, M.3    Iinuma, K.4
  • 20
    • 0025815841 scopus 로고
    • Measurement of aortic blood flow by Doppler echocardiography: Day to day variability in normal subjects and applicability in clinical research
    • L. Moulinier, T. Venet, N.B. Schiller, T.W. Kurtz, R.C. Morris Jr., and A. Sebastian Measurement of aortic blood flow by Doppler echocardiography: day to day variability in normal subjects and applicability in clinical research J Am Coll Cardiol 17 1991 1326 1333
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1326-1333
    • Moulinier, L.1    Venet, T.2    Schiller, N.B.3    Kurtz, T.W.4    Morris Jr., R.C.5    Sebastian, A.6
  • 21
    • 0025616201 scopus 로고
    • Measurement of cardiac output: Fick principle using catheterization
    • R. Fagard, and J. Conway Measurement of cardiac output: Fick principle using catheterization Eur Heart J 11 Suppl. I 1990 1 5
    • (1990) Eur Heart J , vol.11 , Issue.1 SUPPL. , pp. 1-5
    • Fagard, R.1    Conway, J.2
  • 22
    • 0028870457 scopus 로고
    • Oximetric versus indicator dilution techniques for quantitating intracardiac left-to-right shunting in adults
    • W.C. Daniel, R.A. Lange, J.E. Willard, C. Landau, and L.D. Hillis Oximetric versus indicator dilution techniques for quantitating intracardiac left-to-right shunting in adults Am J Cardiol 75 1995 199 200
    • (1995) Am J Cardiol , vol.75 , pp. 199-200
    • Daniel, W.C.1    Lange, R.A.2    Willard, J.E.3    Landau, C.4    Hillis, L.D.5
  • 23
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 24
    • 0033647380 scopus 로고    scopus 로고
    • Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts
    • D.N. Rubin, N. Yazbek, M.J. Garcia, W.J. Stewart, and J.D. Thomas Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts J Am Soc Echocardiogr 13 2000 1012 1018
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 1012-1018
    • Rubin, D.N.1    Yazbek, N.2    Garcia, M.J.3    Stewart, W.J.4    Thomas, J.D.5
  • 25
    • 0033652658 scopus 로고    scopus 로고
    • Does second harmonic imaging improve left ventricular endocardial border identification at higher heart rates during dobutamine stress echocardiography?
    • F.B. Sozzi, D. Poldermans, E. Boersma, A. Elhendy, J.J. Bax, and A. Borghetti Does second harmonic imaging improve left ventricular endocardial border identification at higher heart rates during dobutamine stress echocardiography? J Am Soc Echocardiogr 13 2000 1019 1024
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 1019-1024
    • Sozzi, F.B.1    Poldermans, D.2    Boersma, E.3    Elhendy, A.4    Bax, J.J.5    Borghetti, A.6
  • 26
    • 0037446370 scopus 로고    scopus 로고
    • Comparison of accuracy of left ventricular echocardiographic measurements by fundamental imaging versus second harmonic imaging
    • N. Mansencal, P. Bordachar, G. Chatellier, A. Redheuil, B. Diebold, and E. Abergel Comparison of accuracy of left ventricular echocardiographic measurements by fundamental imaging versus second harmonic imaging Am J Cardiol 91 2003 1037 1039
    • (2003) Am J Cardiol , vol.91 , pp. 1037-1039
    • Mansencal, N.1    Bordachar, P.2    Chatellier, G.3    Redheuil, A.4    Diebold, B.5    Abergel, E.6
  • 27
    • 0036720886 scopus 로고    scopus 로고
    • Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method
    • Y. Ueda, T. Hozumi, K. Yoshida, H. Watanabe, T. Akasaka, and T. Takagi Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method Heart 88 2002 278 282
    • (2002) Heart , vol.88 , pp. 278-282
    • Ueda, Y.1    Hozumi, T.2    Yoshida, K.3    Watanabe, H.4    Akasaka, T.5    Takagi, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.