메뉴 건너뛰기




Volumn 4, Issue 3, 2011, Pages 312-318

Myocardial perfusion imaging after coronary artery bypass surgery using cardiovascular magnetic resonance : A validation study

Author keywords

Cardiovascular imaging; Coronary artery bypass grafting; Myocardial blood flow

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ARTICLE; CARDIOVASCULAR MAGNETIC RESONANCE; CLINICAL ARTICLE; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY DISEASE; CORONARY ARTERY SURGERY; FEMALE; HEART MUSCLE BLOOD FLOW; HEART MUSCLE PERFUSION; HEART MUSCLE REVASCULARIZATION; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; VALIDATION STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY OBSTRUCTION; MYOCARDIAL PERFUSION IMAGING; PATHOPHYSIOLOGY;

EID: 80051730281     PISSN: 19419651     EISSN: 19420080     Source Type: Journal    
DOI: 10.1161/CIRCIMAGING.110.959742     Document Type: Article
Times cited : (12)

References (29)
  • 1
    • 70350492038 scopus 로고    scopus 로고
    • Noninvasive assessment of myocardial perfusion
    • Salerno M, Beller GA. Noninvasive assessment of myocardial perfusion. Circ Cardiovasc Imaging. 2009;2:412-424.
    • (2009) Circ Cardiovasc Imaging. , vol.2 , pp. 412-424
    • Salerno, M.1    Beller, G.A.2
  • 2
    • 0034332786 scopus 로고    scopus 로고
    • Improvement of myocardial perfusion reserve early after coronary intervention: Assessment with cardiac magnetic resonance imaging
    • Al-Saadi N, Nagel E, Gross M, Schnackenburg B, Paetsch I, Klein C, Fleck E. Improvement of myocardial perfusion reserve early after coronary intervention: Assessment with cardiac magnetic resonance imaging. J Am Coll Cardiol. 2000;36:1557-1564.
    • (2000) J Am Coll Cardiol. , vol.36 , pp. 1557-1564
    • Al-Saadi, N.1    Nagel, E.2    Gross, M.3    Schnackenburg, B.4    Paetsch, I.5    Klein, C.6    Fleck, E.7
  • 3
    • 0041663637 scopus 로고    scopus 로고
    • Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease
    • DOI 10.1161/01.CIR.0000080915.35024.A9
    • Nagel E, Klein C, Paetsch I, Hettwer S, Schnackenburg B, Wegscheider K, Fleck E. Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease. Circulation. 2003;108: 432-437. (Pubitemid 36935536)
    • (2003) Circulation , vol.108 , Issue.4 , pp. 432-437
    • Nagel, E.1    Klein, C.2    Paetsch, I.3    Hettwer, S.4    Schnackenburg, B.5    Wegscheider, K.6    Fleck, E.7
  • 5
    • 0035826786 scopus 로고    scopus 로고
    • Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: A comparison with positron emission tomography and coronary angiography
    • Schwitter J, Nanz D, Kneifel S, Bertschinger K, Buchi M, Knusel PR, Marincek B, Luscher TF, von Schulthess GK. Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: A comparison with positron emission tomography and coronary angiography. Circulation. 2001;103:2230-2235. (Pubitemid 32433710)
    • (2001) Circulation , vol.103 , Issue.18 , pp. 2230-2235
    • Schwitter, J.1    Nanz, D.2    Kneifel, S.3    Bertschinger, K.4    Buchi, M.5    Knusel, P.R.6    Marincek, B.7    Luscher, T.F.8    Von Schulthess, G.K.9
  • 7
    • 34748829726 scopus 로고    scopus 로고
    • Effect of distal embolization on myocardial perfusion reserve after percutaneous coronary intervention: A quantitative magnetic resonance perfusion study
    • DOI 10.1161/CIRCULATIONAHA.106.671909
    • Selvanayagam JB, Cheng AS, Jerosch-Herold M, Rahimi K, Porto I, van Gaal W, Channon KM, Neubauer S, Banning AP. Effect of distal embolization on myocardial perfusion reserve after percutaneous coronary intervention: A quantitative magnetic resonance perfusion study. Circulation. 2007;116:1458-1464. (Pubitemid 47480636)
    • (2007) Circulation , vol.116 , Issue.13 , pp. 1458-1464
    • Selvanayagam, J.B.1    Cheng, A.S.H.2    Jerosch-Herold, M.3    Rahimi, K.4    Porto, I.5    Van Gaal, W.6    Channon, K.M.7    Neubauer, S.8    Banning, A.P.9
  • 8
    • 41249096988 scopus 로고    scopus 로고
    • Percutaneous Treatment of Chronic Total Coronary Occlusions Improves Regional Hyperemic Myocardial Blood Flow and Contractility. Insights From Quantitative Cardiovascular Magnetic Resonance Imaging
    • DOI 10.1016/j.jcin.2007.11.003, PII S1936879807000088
    • Cheng AS, Selvanayagam JB, Jerosch-Herold M, van Gaal WJ, Karamitsos TD, Neubauer S, Banning AP. Percutaneous treatment of chronic total coronary occlusions improves regional hyperemic myocardial blood flow and contractility: Insights from quantitative cardiovascular magnetic resonance imaging. J Am Coll Cardiol Cardiovasc Interv. 2008;1:44-53. (Pubitemid 351445417)
    • (2008) JACC: Cardiovascular Interventions , vol.1 , Issue.1 , pp. 44-53
    • Cheng, A.S.H.1    Selvanayagam, J.B.2    Jerosch-Herold, M.3    Van Gaal, W.J.4    Karamitsos, T.D.5    Neubauer, S.6    Banning, A.P.7
  • 10
    • 4143138525 scopus 로고    scopus 로고
    • Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging
    • DOI 10.1148/radiol.2323030573
    • Christian TF, Rettmann DW, Aletras AH, Liao SL, Taylor JL, Balaban RS, Arai AE. Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging. Radiology. 2004;232: 677-684. (Pubitemid 39100248)
    • (2004) Radiology , vol.232 , Issue.3 , pp. 677-684
    • Christian, T.F.1    Rettmann, D.W.2    Aletras, A.H.3    Liao, S.L.4    Taylor, J.L.5    Balaban, R.S.6    Arai, A.E.7
  • 11
    • 0035999417 scopus 로고    scopus 로고
    • Myocardial blood flow quantification with MRI by model-independent deconvolution
    • DOI 10.1118/1.1473135
    • Jerosch-Herold M, Swingen C, Seethamraju RT. Myocardial blood flow quantification with MRI by model-independent deconvolution. Med Phys. 2002;29:886-897. (Pubitemid 34525918)
    • (2002) Medical Physics , vol.29 , Issue.5 , pp. 886-897
    • Jerosch-Herold, M.1    Swingen, C.2    Teja Seethamraju, R.3
  • 12
    • 0031906266 scopus 로고    scopus 로고
    • Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution
    • DOI 10.1118/1.598163
    • Jerosch-Herold M, Wilke N, Stillman AE. Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution. Med Phys. 1998;25:73-84. (Pubitemid 28063691)
    • (1998) Medical Physics , vol.25 , Issue.1 , pp. 73-84
    • Jerosch-Herold, M.1    Wilke, N.2    Stillman, A.E.3    Wilson, R.F.4
  • 14
    • 0015966216 scopus 로고
    • Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve
    • Gould KL, Lipscomb K, Hamilton GW. Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve. Am J Cardiol. 1974;33:87-94.
    • (1974) Am J Cardiol. , vol.33 , pp. 87-94
    • Gould, K.L.1    Lipscomb, K.2    Hamilton, G.W.3
  • 15
    • 0015418509 scopus 로고
    • Myocardial blood flow in man: Effects of coronary collateral circulation and coronary artery bypass surgery
    • Smith SC Jr, Gorlin R, Herman MV, Taylor WJ, Collins JJ Jr. Myocardial blood flow in man: Effects of coronary collateral circulation and coronary artery bypass surgery. J Clin Invest. 1972;51:2556-2565.
    • (1972) J Clin Invest. , vol.51 , pp. 2556-2565
    • Smith Jr., S.C.1    Gorlin, R.2    Herman, M.V.3    Taylor, W.J.4    Collins Jr., J.J.5
  • 18
    • 34248182511 scopus 로고    scopus 로고
    • Evidence for microvascular dysfunction in hypertrophic cardiomyopathy: New insights from multiparametric magnetic resonance imaging
    • DOI 10.1161/CIRCULATIONAHA.106.657023
    • Petersen SE, Jerosch-Herold M, Hudsmith LE, Robson MD, Francis JM, Doll HA, Selvanayagam JB, Neubauer S, Watkins H. Evidence for microvascular dysfunction in hypertrophic cardiomyopathy: New insights from multiparametric magnetic resonance imaging. Circulation. 2007; 115:2418-2425. (Pubitemid 46717964)
    • (2007) Circulation , vol.115 , Issue.18 , pp. 2418-2425
    • Petersen, S.E.1    Jerosch-Herold, M.2    Hudsmith, L.E.3    Robson, M.D.4    Francis, J.M.5    Doll, H.A.6    Selvanayagam, J.B.7    Neubauer, S.8    Watkins, H.9
  • 20
    • 0037192118 scopus 로고    scopus 로고
    • Standardized myocardial sementation and nomenclature for tomographic imaging of the heart: A Statement for Healthcare Professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    • DOI 10.1161/hc0402.102975
    • Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, Pennell DJ, Rumberger JA, Ryan T, Verani MS. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539-542. (Pubitemid 34262671)
    • (2002) Circulation , vol.105 , Issue.4 , pp. 539-542
    • Cerqueira, M.D.1    Weissman, N.J.2    Dilsizian, V.3    Jacobs, A.K.4    Kaul, S.5    Laskey, W.K.6    Pennell, D.J.7    Rumberger, J.A.8    Ryan, T.9    Verani, M.S.10
  • 22
    • 77955859343 scopus 로고    scopus 로고
    • Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery
    • Kelle S, Graf K, Dreysse S, Schnackenburg B, Fleck E, Klein C. Evaluation of contrast wash-in and peak enhancement in adenosine first pass perfusion CMR in patients post bypass surgery. J Cardiovasc Magn Reson. 2010;12:28.
    • (2010) J Cardiovasc Magn Reson. , vol.12 , pp. 28
    • Kelle, S.1    Graf, K.2    Dreysse, S.3    Schnackenburg, B.4    Fleck, E.5    Klein, C.6
  • 23
    • 7044220415 scopus 로고    scopus 로고
    • Functional significance of stenoses in coronary artery bypass grafts: Evaluation by single-photon emission computed tomography perfusion imaging, cardiovascular magnetic resonance, and angiography
    • DOI 10.1016/j.jacc.2004.07.048, PII S0735109704016171
    • Salm LP, Bax JJ, Vliegen HW, Langerak SE, Dibbets P, Jukema JW, Lamb HJ, Pauwels EK, de Roos A, van der Wall EE. Functional significance of stenoses in coronary artery bypass grafts: Evaluation by single-photon emission computed tomography perfusion imaging, cardiovascular magnetic resonance, and angiography. J Am Coll Cardiol. 2004;44:1877-1882. (Pubitemid 39424089)
    • (2004) Journal of the American College of Cardiology , vol.44 , Issue.9 , pp. 1877-1882
    • Salm, L.P.1    Bax, J.J.2    Vliegen, H.W.3    Langerak, S.E.4    Dibbets, P.5    Jukema, J.W.6    Lamb, H.J.7    Pauwels, E.K.J.8    De Roos, A.9    Van Der Wall, E.E.10
  • 28
    • 0031195158 scopus 로고    scopus 로고
    • Coronary vasodilatory capacity and flow reserve in normal myocardium supplied by bypass grafts late after surgery
    • DOI 10.1016/S0002-9149(97)00278-6, PII S0002914997002786
    • Campisi R, Czernin J, Karpman HL, Schelbert HR. Coronary vasodilatory capacity and flow reserve in normal myocardium supplied by bypass grafts late after surgery. Am J Cardiol. 1997;80:27-31. (Pubitemid 27274574)
    • (1997) American Journal of Cardiology , vol.80 , Issue.1 , pp. 27-31
    • Campisi, R.1    Czernin, J.2    Karpman, H.L.3    Schelbert, H.R.4
  • 29
    • 67649574212 scopus 로고    scopus 로고
    • Quantitative contrast-enhanced myocardial perfusion magnetic resonance imaging: Simulation of bolus dispersion in constricted vessels
    • Graafen D, Munnemann K, Weber S, Kreitner KF, Schreiber LM. Quantitative contrast-enhanced myocardial perfusion magnetic resonance imaging: Simulation of bolus dispersion in constricted vessels. Med Phys. 2009;36:3099-3106.
    • (2009) Med Phys. , vol.36 , pp. 3099-3106
    • Graafen, D.1    Munnemann, K.2    Weber, S.3    Kreitner, K.F.4    Schreiber, L.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.