-
1
-
-
0033858823
-
Neuroprosthetic applications of electrical stimulation
-
10.1080/10400435.2000.10132006
-
W. M. Grill R. F. Kirsch 2000 Neuroprosthetic applications of electrical stimulation Assist Technol 12 6 20 10.1080/10400435.2000.10132006
-
(2000)
Assist Technol
, vol.12
, pp. 6-20
-
-
Grill, W.M.1
Kirsch, R.F.2
-
2
-
-
0030822226
-
High-frequency unilateral thalamic stimulation in the treatment of essential and Parkinsonian tremor
-
DOI 10.1002/ana.410420304
-
W. Koller R. Pahwa K. Busenbark, et al. 1997 High-frequency unilateral thalamic stimulation in the treatment of essential and Parkinsonian tremor Ann Neurol 42 292 299 10.1002/ana.410420304 (Pubitemid 27391111)
-
(1997)
Annals of Neurology
, vol.42
, Issue.3
, pp. 292-299
-
-
Koller, W.1
Pahwa, R.2
Busenbark, K.3
Hubble, J.4
Wilkinson, S.5
Lang, A.6
Tuite, P.7
Sime, E.8
Lazano, A.9
Hauser, R.10
Malapira, T.11
Smith, D.12
Tarsy, D.13
Miyawaki, E.14
Norregaard, T.15
Kormos, T.16
Warren Olanow, C.17
-
3
-
-
0031892743
-
Research advances for cochlear implants
-
DOI 10.1016/S0385-8146(97)10030-X, PII S038581469710030X
-
G. M. Clark 1998 Research advances for cochlear implants Auris Nasus Larynx 25 73 87 10.1016/S0385-8146(97)10030-X (Pubitemid 28113233)
-
(1998)
Auris Nasus Larynx
, vol.25
, Issue.1
, pp. 73-87
-
-
Clark, G.M.1
-
4
-
-
22044450476
-
Long-term stimulation by active epiretinal implants in normal and RCD1 dogs
-
DOI 10.1088/1741-2560/2/1/009
-
D. Guven J. D. Weiland G. Fujii, et al. 2005 Long-term stimulation by active epiretinal implants in normal and RCD1 dogs J Neural Eng 2 S65 S73 10.1088/1741-2560/2/1/009 (Pubitemid 41238011)
-
(2005)
Journal of Neural Engineering
, vol.2
, Issue.1
-
-
Guven, D.1
Weiland, J.D.2
Fujii, G.3
Mech, B.V.4
Mahadevappa, M.5
Greenberg, R.6
Roizenblatt, R.7
Qiu, G.8
LaBree, L.9
Wang, X.10
Hinton, D.11
Humayun, M.S.12
-
5
-
-
0029017214
-
Visual prostheses based on direct interfaces with the visual system
-
F. T. Hambrecht 1995 Visual prostheses based on direct interfaces with the visual system Bulliere's Clin Neurol 4 147 165
-
(1995)
Bulliere's Clin Neurol
, vol.4
, pp. 147-165
-
-
Hambrecht, F.T.1
-
6
-
-
50249084472
-
Neural stimulation and recording electrodes
-
10.1146/annurev.bioeng.10.061807.160518
-
S. F. Cogan 2008 Neural stimulation and recording electrodes Annu Rev Biomed Eng 10 275 309 10.1146/annurev.bioeng.10.061807.160518
-
(2008)
Annu Rev Biomed Eng
, vol.10
, pp. 275-309
-
-
Cogan, S.F.1
-
7
-
-
2442708539
-
Wireless implantable microsystems: High-density electronic interfaces to the nervous system
-
DOI 10.1109/JPROC.2003.820544, Biomedical Applications for Mems and Microfluidics
-
K. D. Wise D. J. Anderson J. F. Hetke, et al. 2004 Wireless implantable microsystems: high-density electronic interfaces to the nervous system Proc IEEE 92 76 97 10.1109/JPROC.2003.820544 (Pubitemid 40890773)
-
(2004)
Proceedings of the IEEE
, vol.92
, Issue.1
, pp. 76-97
-
-
Wise, K.D.1
Anderson, D.J.2
Hetke, J.F.3
Kipke, D.R.4
Najafi, K.5
-
8
-
-
77950416386
-
Electrodeposition and characterization of iridium oxide as electrodes material for neural recording and stimulation
-
10.1007/978-3-642-03889-1-126
-
W. Hasenkamp S. Musa A. Alexandru, et al. 2009 Electrodeposition and characterization of iridium oxide as electrodes material for neural recording and stimulation IFMBE Proceedings 25/IX 472 475 10.1007/978-3-642-03889-1-126
-
(2009)
IFMBE Proceedings
, vol.259
, pp. 472-475
-
-
Hasenkamp, W.1
Musa, S.2
Alexandru, A.3
-
9
-
-
70349665564
-
A novel 3D flexible parylene-metal structure fabrication technique
-
Huang X, Tang Y, Wang R, et al. A novel 3D flexible parylene-metal structure fabrication technique. Proc IEEE, 2009. 907-910
-
(2009)
Proc IEEE
, pp. 907-910
-
-
Huang, X.1
Tang, Y.2
Wang, R.3
-
10
-
-
0037086859
-
A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices
-
DOI 10.1016/S0165-0270(01)00514-3, PII S0165027001005143
-
M. O. Heuschkel M. Fejtl M. Raggenbass, et al. 2002 A three-dimensional multi-electrode array for multi-site stimulation and recording in acute brain slices J Neurosci Methods 114 135 148 10.1016/S0165-0270(01)00514-3 (Pubitemid 34150117)
-
(2002)
Journal of Neuroscience Methods
, vol.114
, Issue.2
, pp. 135-148
-
-
Heuschkel, M.O.1
Fejtl, M.2
Raggenbass, M.3
Bertrand, D.4
Renaud, P.5
-
11
-
-
24944485398
-
Production processes for a flexible retina implant
-
K. Hungar M. Gortz E. Alavcheva, et al. 2005 Production processes for a flexible retina implant Sens Actuators A 123-124 172 178
-
(2005)
Sens Actuators A
, vol.123-124
, pp. 172-178
-
-
Hungar, K.1
Gortz, M.2
Alavcheva, E.3
-
12
-
-
2442719087
-
Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface
-
DOI 10.1109/TBME.2004.827465
-
K. A. Moxon N. M. Kalkhoran M. Markert, et al. 2004 Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface IEEE Trans Biomed Eng 51 881 889 10.1109/TBME.2004.827465 (Pubitemid 38661438)
-
(2004)
IEEE Transactions on Biomedical Engineering
, vol.51
, Issue.6
, pp. 881-889
-
-
Moxon, K.A.1
Kalkhoran, N.M.2
Markert, M.3
Sambito, M.A.4
McKenzie, J.L.5
Webster, J.T.6
-
13
-
-
58149527813
-
A thermal treatment approach to reduce microscale void formation in blanket nanoporous gold films
-
10.1016/j.scriptamat.2008.11.027
-
E. Seker M. L. Reed M. R. Begley 2009 A thermal treatment approach to reduce microscale void formation in blanket nanoporous gold films Scr Mater 60 435 438 10.1016/j.scriptamat.2008.11.027
-
(2009)
Scr Mater
, vol.60
, pp. 435-438
-
-
Seker, E.1
Reed, M.L.2
Begley, M.R.3
-
14
-
-
34447332493
-
The effects of post-fabrication annealing on the mechanical properties of freestanding nanoporous gold structures
-
DOI 10.1016/j.actamat.2007.03.018, PII S1359645407002145
-
E. Seker J. T. Gaskins H. Bart-Smith, et al. 2007 The effects of post-fabrication annealing on the mechanical properties of freestanding nanoporous gold structures Acta Mater 55 4593 4602 10.1016/j.actamat.2007.03.018 (Pubitemid 47058338)
-
(2007)
Acta Materialia
, vol.55
, Issue.14
, pp. 4593-4602
-
-
Seker, E.1
Gaskins, J.T.2
Bart-Smith, H.3
Zhu, J.4
Reed, M.L.5
Zangari, G.6
Kelly, R.7
Begley, M.R.8
-
15
-
-
33846570243
-
Platinized platinum, platinum sponge and platinum black
-
A. Mills 2006 Platinized platinum, platinum sponge and platinum black Bull Sci Instrument Society 89 35 37
-
(2006)
Bull Sci Instrument Society
, vol.89
, pp. 35-37
-
-
Mills, A.1
-
17
-
-
60549093178
-
Anodically electrodeposited iridium oxide films microelectrodes for neural microstimulation and recording
-
10.1016/j.snb.2008.11.036
-
Y. Lu T. Y. Wang Z. G. Cai, et al. 2009 Anodically electrodeposited iridium oxide films microelectrodes for neural microstimulation and recording Sens Actuators B: Chem 137 334 339 10.1016/j.snb.2008.11.036
-
(2009)
Sens Actuators B: Chem
, vol.137
, pp. 334-339
-
-
Lu, Y.1
Wang, T.Y.2
Cai, Z.G.3
-
18
-
-
77953426709
-
Improving impedance of implantable microwire multielectrode arrays by ultrasonic electroplating of durable platinum black
-
S. A. Desai J. D. Rolston L. Guo, et al. 2010 Improving impedance of implantable microwire multielectrode arrays by ultrasonic electroplating of durable platinum black Front Neuroeng 3 1 10
-
(2010)
Front Neuroeng
, vol.3
, pp. 1-10
-
-
Desai, S.A.1
Rolston, J.D.2
Guo, L.3
-
19
-
-
38049077314
-
Cytotoxicity of platinum black
-
Schuuettler M, Doerge T, Wien S L, et al. Cytotoxicity of platinum black. 10th Annual Conference of the International FES Society, 2005, S: 343-348
-
(2005)
10th Annual Conference of the International FES Society
, Issue.S
, pp. 343-348
-
-
Schuuettler, M.1
Doerge, T.2
Wien, S.L.3
-
20
-
-
0024648111
-
Anodically electrodeposited iridium oxide films (AEIROF) from alkaline solutions for electrochromic display devices
-
10.1143/JJAP.28.632
-
K. Yamanaka 1989 Anodically electrodeposited iridium oxide films (AEIROF) from alkaline solutions for electrochromic display devices Jpn J Appl Phys 28 632 637 10.1143/JJAP.28.632
-
(1989)
Jpn J Appl Phys
, vol.28
, pp. 632-637
-
-
Yamanaka, K.1
-
21
-
-
56749176704
-
Effects of electrodeposition conditions and protocol on the properties of iridium oxide pH sensor electrodes
-
10.1149/1.3001924
-
H. A. Elsen C. F. Monson M. Majda 2009 Effects of electrodeposition conditions and protocol on the properties of iridium oxide pH sensor electrodes J Electrochem Soc 156 F1 F6 10.1149/1.3001924
-
(2009)
J Electrochem Soc
, vol.156
-
-
Elsen, H.A.1
Monson, C.F.2
Majda, M.3
-
22
-
-
34047169835
-
Electrode-electrolyte interface properties in implantation conditions
-
DOI 10.1109/IEMBS.2006.259712, 4029985, 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'06
-
Riistama J, Lekkala J. Electrode-electrolyte interface properties in implantation conditions. Engineering in Medicine and Biology Society. EMBS 06, 28th Annual International Conference of the IEEE, 2006: 6021-6024 (Pubitemid 46521291)
-
(2006)
Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
, pp. 6021-6024
-
-
Riistama, J.1
Lekkala, J.2
-
23
-
-
67650727137
-
Development of silicon-based microelectrode array
-
10.1007/s11431-008-0176-8
-
J. H. Lin X. M. Wu P. S. Huang, et al. 2009 Development of silicon-based microelectrode array Sci China Ser E-Tech Sci 52 2391 2395 10.1007/s11431-008- 0176-8
-
(2009)
Sci China ser E-Tech Sci
, vol.52
, pp. 2391-2395
-
-
Lin, J.H.1
Wu, X.M.2
Huang, P.S.3
-
24
-
-
0347927495
-
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
-
DOI 10.1109/TBME.2002.805487
-
J. D. Weiland D. J. Anderson M. S. Humayun 2002 In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes IEEE Trans Biomed Eng 49 1574 1579 10.1109/TBME.2002.805487 (Pubitemid 36055715)
-
(2002)
IEEE Transactions on Biomedical Engineering
, vol.49
, Issue.12
, pp. 1574-1579
-
-
Weiland, J.D.1
Anderson, D.J.2
Humayun, M.S.3
|