메뉴 건너뛰기




Volumn 31, Issue 8, 2011, Pages 1687-1695

Vessel size imaging reveals pathological changes of microvessel density and size in acute ischemia

Author keywords

Acute stroke; brain imaging; brain ischemia; MRI; perfusion weighted MRI

Indexed keywords

GADOBUTROL;

EID: 79961002995     PISSN: 0271678X     EISSN: 15597016     Source Type: Journal    
DOI: 10.1038/jcbfm.2011.38     Document Type: Article
Times cited : (32)

References (37)
  • 2
    • 0035839175 scopus 로고    scopus 로고
    • Regional variation in brain capillary density and vascular response to ischemia
    • DOI 10.1016/S0006-8993(01)02637-3, PII S0006899301026373
    • Cavaglia M, Dombrowski SM, Drazba J, Vasanji A, Bokesch PM, Janigro D (2001) Regional variation in brain capillary density and vascular response to ischemia. Brain Res 910:81-93 (Pubitemid 32727331)
    • (2001) Brain Research , vol.910 , Issue.1-2 , pp. 81-93
    • Cavaglia, M.1    Dombrowski, S.M.2    Drazba, J.3    Vasanji, A.4    Bokesch, P.M.5    Janigro, D.6
  • 3
    • 68749087328 scopus 로고    scopus 로고
    • MR mismatch and thrombo-lysis: Appealing but validation required
    • Davis SM, Donnan GA (2009) MR mismatch and thrombo-lysis: appealing but validation required. Stroke 40:2910
    • (2009) Stroke , vol.40 , pp. 2910
    • Davis, S.M.1    Donnan, G.A.2
  • 6
    • 74049132499 scopus 로고    scopus 로고
    • Reliable perfu-sion maps in stroke MRI using arterial input functions derived from distal middle cerebral artery branches
    • Ebinger M, Brunecker P, Jungehulsing GJ, Malzahn U, Kunze C, Endres M, Fiebach JB (2010) Reliable perfu-sion maps in stroke MRI using arterial input functions derived from distal middle cerebral artery branches. Stroke 41:95-101
    • (2010) Stroke , vol.41 , pp. 95-101
    • Ebinger, M.1    Brunecker, P.2    Jungehulsing, G.J.3    Malzahn, U.4    Kunze, C.5    Endres, M.6    Fiebach, J.B.7
  • 7
    • 68749092874 scopus 로고    scopus 로고
    • MR mismatch is useful for patient selection for thrombolysis: Yes
    • Fiebach JB, Schellinger PD (2009) MR mismatch is useful for patient selection for thrombolysis: yes. Stroke 40:2906-7
    • (2009) Stroke , vol.40 , pp. 2906-2907
    • Fiebach, J.B.1    Schellinger, P.D.2
  • 8
    • 77956393305 scopus 로고    scopus 로고
    • On the design of filters for fourier and oSVD-based deconvolution in bolus tracking perfusion MRI
    • Gall P, Emerich P, Kjølby B, Kellner E, Mader I, Kiselev V (2010) On the design of filters for fourier and oSVD-based deconvolution in bolus tracking perfusion MRI. Magn Reson Mater Phy 23:187-95
    • (2010) Magn Reson Mater Phy , vol.23 , pp. 187-195
    • Gall, P.1    Emerich, P.2    Kjølby, B.3    Kellner, E.4    Mader, I.5    Kiselev, V.6
  • 10
    • 3242781057 scopus 로고    scopus 로고
    • Probability of cortical infarction predicted by flumazenil binding and diffusion-weighted imaging signal intensity: A comparative positron emission tomography/magnetic resonance imaging study in early ischemic stroke
    • DOI 10.1161/01.STR.0000134746.93535.9b
    • Heiss W-D, Sobesky J, Smekal Uv, Kracht LW, Lehnhardt F-G, Thiel A, Jacobs AH, Lackner K (2004) Probability of cortical infarction predicted by flumazenil binding and diffusion-weighted imaging signal intensity: a comparative positron emission tomography/magnetic resonance imaging study in early ischemic stroke. Stroke 35:1892-8 (Pubitemid 38971871)
    • (2004) Stroke , vol.35 , Issue.8 , pp. 1892-1898
    • Heiss, W.-D.1    Sobesky, J.2    Smekal, U.V.3    Kracht, L.W.4    Lehnhardt, F.-G.5    Thiel, A.6    Jacobs, A.H.7    Lackner, K.8
  • 13
    • 78650910604 scopus 로고    scopus 로고
    • Temporary focal cerebral ischemia results in swollen astrocytic end-feet thatcompress microvessels and lead to focal cortical infarction
    • Ito U, Hakamata Y, Kawakami E, Oyanagi K (2010) Temporary focal cerebral ischemia results in swollen astrocytic end-feet thatcompress microvessels and lead to focal cortical infarction. J Cereb Blood Flow Metab 31:328-38
    • (2010) J Cereb Blood Flow Metab , vol.31 , pp. 328-338
    • Ito, U.1    Hakamata, Y.2    Kawakami, E.3    Oyanagi, K.4
  • 14
    • 0033866436 scopus 로고    scopus 로고
    • MR imaging of microvascu-lature
    • Jensen JH, Chandra R (2000) MR imaging of microvascu-lature. Magn Reson Med 44:224-30
    • (2000) Magn Reson Med , vol.44 , pp. 224-230
    • Jensen, J.H.1    Chandra, R.2
  • 15
    • 33750604802 scopus 로고    scopus 로고
    • Microvessel density estimation in the human brain by means of dynamic contrast-enhanced echo-planar imaging
    • Jensen JH, Lu H, Inglese M (2006) Microvessel density estimation in the human brain by means of dynamic contrast-enhanced echo-planar imaging. Magn Reson Med 56:1145-50
    • (2006) Magn Reson Med , vol.56 , pp. 1145-1450
    • Jensen, J.H.1    Lu, H.2    Inglese, M.3
  • 17
    • 0242694042 scopus 로고    scopus 로고
    • Beyond mismatch: Evolving paradigms in imaging the ischemic penumbra with multimodal magnetic resonance imaging
    • Kidwell CS, Alger JR, Saver JL (2003) Beyond mismatch: evolving paradigms in imaging the ischemic penumbra with multimodal magnetic resonance imaging. Stroke 34:2729-35
    • (2003) Stroke , vol.34 , pp. 2729-2235
    • Kidwell, C.S.1    Alger, J.R.2    Saver, J.L.3
  • 19
    • 48749131147 scopus 로고    scopus 로고
    • Dynamic changes in vascular permeability, cerebral blood volume, vascular density, and size after transient focal cerebral ischemia in rats: Evaluation with contrast-enhanced magnetic resonance imaging
    • Lin C-Y, Chang C, Cheung W-M, Lin M-H, Chen J-J, Hsu CY, Chen J-H, Lin T-N (2008) Dynamic changes in vascular permeability, cerebral blood volume, vascular density, and size after transient focal cerebral ischemia in rats: evaluation with contrast-enhanced magnetic resonance imaging. J Cereb Blood Flow Metab 28:1491-501
    • (2008) J Cereb Blood Flow Metab , vol.28 , pp. 1491-501
    • Lin, C.-Y.1    Chang, C.2    Cheung, W.-M.3    Lin, M.-H.4    Chen, J.-J.5    Hsu, C.Y.6    Chen, J.-H.7    Lin, T.-N.8
  • 20
    • 18244380066 scopus 로고    scopus 로고
    • 2 EP2 receptor in permanent focal cerebral ischemia
    • DOI 10.1002/ana.20461
    • Liu D, Wu L, Breyer R, Mattson MP, Andreasson K (2005) Neuroprotection by the PGE2 EP2 receptor in permanent focal cerebral ischemia. Ann Neurol 57:758-61 (Pubitemid 40628868)
    • (2005) Annals of Neurology , vol.57 , Issue.5 , pp. 758-761
    • Liu, D.1    Wu, L.2    Breyer, R.3    Mattson, M.P.4    Andreasson, K.5
  • 22
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis
    • DOI 10.1002/mrm.1910360510
    • Ostergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR (1996) High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: mathematical approach and statistical analysis. Magn Reson Med 36:715-25 (Pubitemid 26376710)
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.5 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, G.4    Rosen, B.R.5
  • 23
    • 0026063830 scopus 로고
    • Cerebral hemodynamics in ischemic cerebrovascular disease
    • Powers WJ (1991) Cerebral hemodynamics in ischemic cerebrovascular disease. Ann Neurol 29:231-40
    • (1991) Ann Neurol , vol.29 , pp. 231-240
    • Powers, W.J.1
  • 24
    • 33645081754 scopus 로고    scopus 로고
    • Hydrogen sulfide is a mediator of cerebral ischemic damage
    • DOI 10.1161/01.STR.0000204184.34946.41, PII 0000767020060300000037
    • Qu K, Chen CP, Halliwell B, Moore PK, Wong PT (2006) Hydrogen sulfide is a mediator of cerebral ischemic damage. Stroke 37:889-93 (Pubitemid 43731927)
    • (2006) Stroke , vol.37 , Issue.3 , pp. 889-893
    • Qu, K.1    Chen, C.P.L.H.2    Halliwell, B.3    Moore, P.K.4    Wong, P.T.-H.5
  • 25
    • 33644878711 scopus 로고    scopus 로고
    • Do acute diffusion- and perfusion-weighted MRI lesions identify final infarct volume in ischemic stroke?
    • DOI 10.1161/01.STR.0000195197.66606.bb, PII 0000767020060100000024
    • Rivers CS, Wardlaw JM, Armitage PA, Bastin ME, Carpenter TK, Cvoro V, Hand PJ, Dennis MS (2006) Do acute diffusion-and perfusion-weighted MRI lesions identify final infarct volume in ischemic stroke? Stroke 37:98-104 (Pubitemid 43732055)
    • (2006) Stroke , vol.37 , Issue.1 , pp. 98-104
    • Rivers, C.S.1    Wardlaw, J.M.2    Armitage, P.A.3    Bastin, M.E.4    Carpenter, T.K.5    Cvoro, V.6    Hand, P.J.7    Dennis, M.S.8
  • 26
    • 68749118408 scopus 로고    scopus 로고
    • MR mismatch is useful for patient selection for thrombolysis: No
    • Schabitz W-R (2009) MR mismatch is useful for patient selection for thrombolysis: no. Stroke 40:2908-9
    • (2009) Stroke , vol.40 , pp. 2908-2909
    • Schabitz, W.-R.1
  • 27
    • 18244367363 scopus 로고    scopus 로고
    • Does the mismatch match the penumbra? Magnetic resonance imaging and positron emission tomography in early ischemic stroke
    • DOI 10.1161/01.STR.0000160751.79241.a3
    • Sobesky J, Weber OZ, Lehnhardt F-G, Hesselmann V, Neveling M, Jacobs A, Heiss W-D (2005) Does the mismatch match the penumbra?: magnetic resonance imaging and positron emission tomography in early ischemic stroke. Stroke 36:980-5 (Pubitemid 40629288)
    • (2005) Stroke , vol.36 , Issue.5 , pp. 980-985
    • Sobesky, J.1    Weber, O.Z.2    Lehnhardt, F.-G.3    Hesselmann, V.4    Neveling, M.5    Jacobs, A.6    Heiss, W.-D.7
  • 30
    • 59849089918 scopus 로고    scopus 로고
    • Assessment of blood volume, vessel size, and the expression of angiogenic factors in two rat glioma models: A longitudinal in vivo and ex vivo study
    • Valable S, Lemasson B, Farion R, Beaumont M, Segebarth C, Remy C, Barbier EL (2008) Assessment of blood volume, vessel size, and the expression of angiogenic factors in two rat glioma models: a longitudinal in vivo and ex vivo study. NMR Biomed 21:1043-56
    • (2008) NMR Biomed , vol.21 , pp. 1043-1456
    • Valable, S.1    Lemasson, B.2    Farion, R.3    Beaumont, M.4    Segebarth, C.5    Remy, C.6    Barbier, E.L.7
  • 31
    • 0036842344 scopus 로고    scopus 로고
    • Transient focal ischemia increases endothelial nitric oxide synthase in cerebral blood vessels
    • Veltkamp R, Rajapakse N, Robins G, Puskar M, Shimizu K, Busija D (2002) Transient focal ischemia increases endothelial nitric oxide synthase in cerebral blood vessels. Stroke 33:2704-10
    • (2002) Stroke , vol.33 , pp. 2704-2010
    • Veltkamp, R.1    Rajapakse, N.2    Robins, G.3    Puskar, M.4    Shimizu, K.5    Busija, D.6
  • 33
    • 9244252480 scopus 로고    scopus 로고
    • High-resolution MR imaging of mouse brain microvasculature using the relaxation rate shift index Q
    • DOI 10.1002/nbm.921
    • Wu EX, Tang H, Jensen JH (2004) High-resolution MR imaging of mouse brain microvasculature using the relaxation rate shift index Q. NMR Biomed 17:507-12 (Pubitemid 39549428)
    • (2004) NMR in Biomedicine , vol.17 , Issue.7 , pp. 507-512
    • Wu, E.X.1    Tang, H.2    Jensen, J.H.3
  • 34
    • 77649165356 scopus 로고    scopus 로고
    • MRI perfusion maps in acute stroke validated with 15O-water positron emission tomography
    • Zaro-Weber O, Moeller-Hartmann W, Heiss WD, Sobesky J (2010) MRI perfusion maps in acute stroke validated with 15O-water positron emission tomography. Stroke 41:443-9
    • (2010) Stroke , vol.41 , pp. 443-449
    • Zaro-Weber, O.1    Moeller-Hartmann, W.2    Heiss, W.D.3    Sobesky, J.4
  • 36
    • 33646149376 scopus 로고    scopus 로고
    • Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: Insights into hemodynamic regulation
    • Zhao F, Wang P, Hendrich K, Ugurbil K, Kim SG (2006) Cortical layer-dependent BOLD and CBV responses measured by spin-echo and gradient-echo fMRI: insights into hemodynamic regulation. Neuro-image 30:1149-60
    • (2006) Neuro-image , vol.30 , pp. 1149-1460
    • Zhao, F.1    Wang, P.2    Hendrich, K.3    Ugurbil, K.4    Kim, S.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.