메뉴 건너뛰기




Volumn 9, Issue 2, 2011, Pages 151-163

Technical features and criteria in designing fiber-reinforced composite materials: From the aerospace and aeronautical field to biomedical applications

Author keywords

Applications; Basic principles; Fiber reinforced composite materials; Prosthetic implants and models; Tailored properties; Technologies

Indexed keywords

ANISOTROPY; ARTICLE; AVIATION; BIOCOMPATIBILITY; BIODEGRADABILITY; BIOMECHANICS; BIOMEDICAL ENGINEERING; BIOMEDICINE; BIOMIMETICS; COMPOSITE MATERIAL; HIP PROSTHESIS; INTERVERTEBRAL DISK; OSTEOLYSIS; POLYMERIZATION; PROCESS DESIGN; PROCESS TECHNOLOGY; PROSTHESIS; TEMPERATURE DEPENDENCE; TENDON; TENSILE STRENGTH; VISCOELASTICITY;

EID: 79960999945     PISSN: 17226899     EISSN: None     Source Type: Journal    
DOI: 10.5301/JABB.2011.8569     Document Type: Article
Times cited : (70)

References (85)
  • 4
    • 77957292983 scopus 로고    scopus 로고
    • The mechanics of biocomposites
    • In: Ambrosio L, ed., Cambridge, UK: Woodhead Publishing Limited, CRC Press
    • Nicolais L, Gloria A, Ambrosio L. The mechanics of biocomposites. In: Ambrosio L, ed. Biomedical composites. Cambridge, UK: Woodhead Publishing Limited, CRC Press; 2010; 411-440.
    • (2010) Biomedical Composites , pp. 411-440
    • Nicolais, L.1    Gloria, A.2    Ambrosio, L.3
  • 7
    • 84989065508 scopus 로고
    • Mechanics of composites
    • Nicolais L. Mechanics of composites. Polym Eng Sci 1975; 15: 137-49.
    • (1975) Polym Eng Sci , vol.15 , pp. 137-149
    • Nicolais, L.1
  • 8
    • 0025037240 scopus 로고
    • Utilization of composite laminate theory in the design of synthetic soft tissues for biomedical prostheses
    • Gershon B, Cohn D, Marom G. Utilization of composite laminate theory in the design of synthetic soft tissues for biomedical prostheses. Biomater 1990; 11: 548-52.
    • (1990) Biomater , vol.11 , pp. 548-552
    • Gershon, B.1    Cohn, D.2    Marom, G.3
  • 10
    • 84880682757 scopus 로고    scopus 로고
    • Composite materials for replacement of ligaments and tendons
    • In: Ambrosio L, ed., Cambridge, UK: Woodhead Publishing Limited, CRC Press
    • Ambrosio L, Gloria A, Causa F. Composite materials for replacement of ligaments and tendons. In: Ambrosio L, ed. Biomedical composites. Cambridge, UK: Woodhead Publishing Limited, CRC Press; 2010: 234-254.
    • (2010) Biomedical Composites , pp. 234-254
    • Ambrosio, L.1    Gloria, A.2    Causa, F.3
  • 11
    • 84964147915 scopus 로고
    • Stiffness and expansion estimates for oriented short fiber composites
    • Halpin JC. Stiffness and expansion estimates for oriented short fiber composites. J Comp Mat 1969; 3: 732-4.
    • (1969) J Comp Mat , vol.3 , pp. 732-734
    • Halpin, J.C.1
  • 12
    • 79960980069 scopus 로고
    • Manufacturing methods
    • In: Ploskonka CA, ed., Society of Manufacturing Engineers, Publications Development Dept., Reference Publications Division, Dearborn, Michigan
    • Strong BA. Manufacturing methods. In: Ploskonka CA, ed. Fundamentals of composites manufacturing: materials, methods, and applications. Society of Manufacturing Engineers, Publications Development Dept., Reference Publications Division, Dearborn, Michigan; 1989; 107-159.
    • (1989) Fundamentals of Composites Manufacturing: Materials, Methods, and Applications , pp. 107-159
    • Strong, B.A.1
  • 13
    • 79961009771 scopus 로고    scopus 로고
    • Composite materials for spinal implants
    • In: Ambrosio L, ed., Cambridge, UK: Woodhead Publishing Limited, CRC Press
    • Gloria A, De Santis R, Causa F, Ambrosio L. Composite materials for spinal implants. In: Ambrosio L, ed. Biomedical composites. Cambridge, UK: Woodhead Publishing Limited, CRC Press; 2010; 178-200.
    • (2010) Biomedical Composites , pp. 178-200
    • Gloria, A.1    de Santis, R.2    Causa, F.3    Ambrosio, L.4
  • 16
    • 0029311081 scopus 로고
    • Mechanical behaviour of composite artificial tendons and ligaments
    • Iannace S, Sabatini G, Ambrosio L, Nicolais L. Mechanical behaviour of composite artificial tendons and ligaments. Biomater 1995; 16: 675-680.
    • (1995) Biomater , vol.16 , pp. 675-680
    • Iannace, S.1    Sabatini, G.2    Ambrosio, L.3    Nicolais, L.4
  • 17
    • 0021330969 scopus 로고
    • Tendons and ligaments: A morphological and biochemical comparison
    • Amiel D, Frank C, Harwood F, Fronek J, Akeson W. Tendons and ligaments: A morphological and biochemical comparison. J Orthop Res 1984; 1: 257-265.
    • (1984) J Orthop Res , vol.1 , pp. 257-265
    • Amiel, D.1    Frank, C.2    Harwood, F.3    Fronek, J.4    Akeson, W.5
  • 18
    • 0021860920 scopus 로고
    • Autogenic anterior cruciate ligaments (ACL) anterior reconstruction of the knee
    • Friedman MJ, Sherman OH, Fox JM. Autogenic anterior cruciate ligaments (ACL) anterior reconstruction of the knee. Clin Orthop 1985; 196: 9-14.
    • (1985) Clin Orthop , vol.196 , pp. 9-14
    • Friedman, M.J.1    Sherman, O.H.2    Fox, J.M.3
  • 19
    • 79960994935 scopus 로고
    • Biomaterials, Medical Devices and Tissue Engineering: An Integrated Approach, Chapman & Hall, London, UK
    • Silver FH (1994), Biomaterials, Medical Devices and Tissue Engineering: An Integrated Approach, Chapman & Hall, London, UK, 92.
    • (1994) , pp. 92
    • Silver, F.H.1
  • 22
    • 0018878504 scopus 로고
    • Composite materials for biomedical applications
    • Migliaresi C, Nicolais L. Composite materials for biomedical applications. Int J Artif Organs 1980; 3: 114-118.
    • (1980) Int J Artif Organs , vol.3 , pp. 114-118
    • Migliaresi, C.1    Nicolais, L.2
  • 28
    • 33747185681 scopus 로고    scopus 로고
    • Artificial Disc Technology
    • Bao, QB and Yuan, HA Artificial Disc Technology. Neurosurg Focus 2000; 9: 1-7.
    • (2000) Neurosurg Focus , vol.9 , pp. 1-7
    • Bao, Q.B.1    Yuan, H.A.2
  • 29
    • 36448975849 scopus 로고    scopus 로고
    • Dynamic-mechanical properties of a novel composite intervertebral disc prosthesis
    • Gloria A, Causa F, De Santis R, Netti PA, Ambrosio L. Dynamic-mechanical properties of a novel composite intervertebral disc prosthesis. J Mater Sci Mater Med 2007; 18: 2159-2165.
    • (2007) J Mater Sci Mater Med , vol.18 , pp. 2159-2165
    • Gloria, A.1    Causa, F.2    de Santis, R.3    Netti, P.A.4    Ambrosio, L.5
  • 30
    • 79957638054 scopus 로고    scopus 로고
    • A Multi-component Fiber-reinforced PHEMA-based Hydrogel/ HAPEXTM Device for Customized Intervertebral Disc Prosthesis
    • Gloria A, De Santis R, Ambrosio L, Causa F, Tanner KE. A Multi-component Fiber-reinforced PHEMA-based Hydrogel/ HAPEXTM Device for Customized Intervertebral Disc Prosthesis. J Appl Biomater 2011; 25: 795-810.
    • (2011) J Appl Biomater , vol.25 , pp. 795-810
    • Gloria, A.1    de Santis, R.2    Ambrosio, L.3    Causa, F.4    Tanner, K.E.5
  • 31
    • 0022868055 scopus 로고
    • Mechanical Properties of Lumbar Spinal Motion Segments as Affected by Partial Disc Removal
    • Goel VK, Nishiyama K, Weinstein JN, Liu YK. Mechanical Properties of Lumbar Spinal Motion Segments as Affected by Partial Disc Removal. Spine 1986; 11: 1008-12.
    • (1986) Spine , vol.11 , pp. 1008-1012
    • Goel, V.K.1    Nishiyama, K.2    Weinstein, J.N.3    Liu, Y.K.4
  • 32
    • 0024328254 scopus 로고
    • The Development of Low-back Pain After Excision of a Lumber Disc
    • Am
    • Hanley EN Jr, Shapiro DE. The Development of Low-back Pain After Excision of a Lumber Disc. J Bone Joint Surg. (Am) 1989; 71-A: 719-721.
    • (1989) J Bone Joint Surg , vol.71 A , pp. 719-721
    • Hanley Jr., E.N.1    Shapiro, D.E.2
  • 33
    • 0016075164 scopus 로고
    • The Structural Components of the Intervertebral Disc
    • Markolf KL, Morris JM. The Structural Components of the Intervertebral Disc. J Bone Joint Surg (Am) 1974; 56: 675-687.
    • (1974) J Bone Joint Surg (Am) , vol.56 , pp. 675-687
    • Markolf, K.L.1    Morris, J.M.2
  • 34
  • 35
    • 0024782770 scopus 로고
    • Hierarchical Structure of the Intervertebral Disc
    • Cassidy JJ, Hiltner A, Baer E. Hierarchical Structure of the Intervertebral Disc. Connect Tissue Res 1989; 23: 75-88.
    • (1989) Connect Tissue Res , vol.23 , pp. 75-88
    • Cassidy, J.J.1    Hiltner, A.2    Baer, E.3
  • 36
    • 10644233992 scopus 로고    scopus 로고
    • A Biomimetic Artificial Disc with Improved Mechanical Properties Compared to Biological Intervertebral Discs
    • Shikinami Y, Kotani Y, Cunningham BW, Abumi K, Kaneda K. A Biomimetic Artificial Disc with Improved Mechanical Properties Compared to Biological Intervertebral Discs. Adv Funct Mater 2004; 14: 1039-1046.
    • (2004) Adv Funct Mater , vol.14 , pp. 1039-1046
    • Shikinami, Y.1    Kotani, Y.2    Cunningham, B.W.3    Abumi, K.4    Kaneda, K.5
  • 37
    • 84874792867 scopus 로고
    • The Development of the Artificial Disc SB Charité. Dallas, Hundley & Associates
    • Buttner-Janz K. The Development of the Artificial Disc SB Charité. Dallas, Hundley & Associates 1992.
    • (1992)
    • Buttner-Janz, K.1
  • 38
    • 2442609363 scopus 로고    scopus 로고
    • Spinal arthroplasty
    • Article 10
    • Traynelis VC. Spinal arthroplasty. Neurosurg Focus 2002; 13: Article 10; 1-7.
    • (2002) Neurosurg Focus , vol.13 , pp. 1-7
    • Traynelis, V.C.1
  • 41
    • 0014746120 scopus 로고
    • Abduction forces in one-legged stance
    • McLeish RD and Charnley J. Abduction forces in one-legged stance. J Biomech 1970; 3:191-200.
    • (1970) J Biomech , vol.3 , pp. 191-200
    • McLeish, R.D.1    Charnley, J.2
  • 42
    • 0014808492 scopus 로고
    • Muscle function in locomotion
    • Morrison JB. Muscle function in locomotion. J Biomech 1970; 3: 431-451.
    • (1970) J Biomech , vol.3 , pp. 431-451
    • Morrison, J.B.1
  • 43
    • 0034941922 scopus 로고    scopus 로고
    • The force resulting from the action of mono and biarticular muscles in a limb
    • Hof AL. The force resulting from the action of mono and biarticular muscles in a limb. J Biomech 2001; 34: 1085-1089.
    • (2001) J Biomech , vol.34 , pp. 1085-1089
    • Hof, A.L.1
  • 44
    • 79961006921 scopus 로고    scopus 로고
    • Composite materials for hip joint prostheses
    • In: Ambrosio L, ed., Cambridge, UK: Woodhead Publishing Limited, CRC Press
    • De Santis R, Gloria A, Ambrosio L. Composite materials for hip joint prostheses. In: Ambrosio L, ed. Biomedical composites. Cambridge, UK: Woodhead Publishing Limited, CRC Press; 2010; 276-295.
    • (2010) Biomedical Composites , pp. 276-295
    • de Santis, R.1    Gloria, A.2    Ambrosio, L.3
  • 46
    • 0142148008 scopus 로고    scopus 로고
    • Trabecular bone tissue strains in the healthy and osteoporotic human femur
    • Van Rietbergen B, Huiskes R, Eckstein F, Ruegsegger P. Trabecular bone tissue strains in the healthy and osteoporotic human femur. J Bone Miner Res 2003; 18: 1781-1788.
    • (2003) J Bone Miner Res , vol.18 , pp. 1781-1788
    • van Rietbergen, B.1    Huiskes, R.2    Eckstein, F.3    Ruegsegger, P.4
  • 48
    • 0036122131 scopus 로고    scopus 로고
    • Outcomes of surgical management of total HIP replacement in patients aged 65 years and older: Cemented versus cementless femoral components and lateral or anterolateral versus posterior anatomical approach
    • Zimmerman S, Hawekes WG, Hudson JI, et al. Outcomes of surgical management of total HIP replacement in patients aged 65 years and older: cemented versus cementless femoral components and lateral or anterolateral versus posterior anatomical approach. J Orthop Res 2002, 20: 182-191.
    • (2002) J Orthop Res , vol.20 , pp. 182-191
    • Zimmerman, S.1    Hawekes, W.G.2    Hudson, J.I.3
  • 49
    • 0027560442 scopus 로고
    • Non-Linear Viscoelastic Behavior of Poly-Ether-Ether-Ketone (PEEK) and PEEK-Based Composites
    • D'Amore A, Pompo A, Netti P, Masi E, Nicolais L. Non-Linear Viscoelastic Behavior of Poly-Ether-Ether-Ketone (PEEK) and PEEK-Based Composites. J Reinf Plastics Comp 1993; 327-340.
    • (1993) J Reinf Plastics Comp , pp. 327-340
    • D'amore, A.1    Pompo, A.2    Netti, P.3    Masi, E.4    Nicolais, L.5
  • 50
    • 0024032469 scopus 로고
    • The contribution of thermal stresses to the failure of Kevlar fabric composites
    • Deteresa SJ, Nicolais L. The contribution of thermal stresses to the failure of Kevlar fabric composites. Polym Composite 1988; 9: 192-197.
    • (1988) Polym Composite , vol.9 , pp. 192-197
    • Deteresa, S.J.1    Nicolais, L.2
  • 51
    • 2442676287 scopus 로고    scopus 로고
    • Wear characteristic and biocompatibility of some polymer composite acetabular cups
    • Chowdhury Roy SK, Mishra1 A, Pradhan B and Saha D. Wear characteristic and biocompatibility of some polymer composite acetabular cups. Wear 2004; 256: 1026-1036.
    • (2004) Wear , vol.256 , pp. 1026-1036
    • Chowdhury, R.K.1    Mishra, A.2    Pradhan, B.3    Saha, D.4
  • 52
    • 0842329793 scopus 로고    scopus 로고
    • Carbon-carbon composite bearing materials in hip arthroplasty: Analysis of wear and biological response to wear debris
    • Howling GI, Ingham E, Sakoda H, et al. Carbon-carbon composite bearing materials in hip arthroplasty: analysis of wear and biological response to wear debris. J Mater Sci Mater Med 2004, 15: 91-98.
    • (2004) J Mater Sci Mater Med , vol.15 , pp. 91-98
    • Howling, G.I.1    Ingham, E.2    Sakoda, H.3
  • 53
    • 0242455836 scopus 로고    scopus 로고
    • Overview of total hip arthroplasty
    • In: Callaghan JJ, Rosenberg AG, Rubash HE, Philadelphia, Pa: Lippincott- Raven
    • Galante JO. Overview of total hip arthroplasty. In: Callaghan JJ, Rosenberg AG, Rubash HE. The adult hip. Philadelphia, Pa: Lippincott- Raven; 1998; Vol 2; 829-837.
    • (1998) The Adult Hip , vol.2 , pp. 829-837
    • Galante, J.O.1
  • 54
    • 0024242580 scopus 로고
    • Synovial sarcoma associated with total hip replacement
    • Lamovec J, Zidar A, Cucek M. Synovial sarcoma associated with total hip replacement. J Bone Joint Surg 1988; 70A: 1558-1560.
    • (1988) J Bone Joint Surg , vol.70 A , pp. 1558-1560
    • Lamovec, J.1    Zidar, A.2    Cucek, M.3
  • 57
    • 0032143082 scopus 로고    scopus 로고
    • Composite technology in load-bearing orthopaedic implants
    • Evans SL, Gregson PJ. Composite technology in load-bearing orthopaedic implants. Biomaterials 1998; 19: 1329-1342.
    • (1998) Biomaterials , vol.19 , pp. 1329-1342
    • Evans, S.L.1    Gregson, P.J.2
  • 58
    • 0026519501 scopus 로고
    • Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty
    • Bobyn JD, Mortimer ES, Glassman AH, Engh CA, Miller JE, Brooks CE. Producing and avoiding stress shielding. Laboratory and clinical observations of noncemented total hip arthroplasty. Clin Orthop Rel Res 1992; 274: 79-96.
    • (1992) Clin Orthop Rel Res , vol.274 , pp. 79-96
    • Bobyn, J.D.1    Mortimer, E.S.2    Glassman, A.H.3    Engh, C.A.4    Miller, J.E.5    Brooks, C.E.6
  • 59
    • 0030627449 scopus 로고    scopus 로고
    • Composite hip prosthesis design. I. Analysis
    • Yildiz H, Ha SK, Chang FK. Composite hip prosthesis design. I. Analysis. J Biomed Mater Res A 1998; 39: 92-101.
    • (1998) J Biomed Mater Res A , vol.39 , pp. 92-101
    • Yildiz, H.1    Ha, S.K.2    Chang, F.K.3
  • 60
    • 0030631585 scopus 로고    scopus 로고
    • Composite hip prosthesis design. II. Simulation
    • Yildiz H, Chang FK, Goodman S. Composite hip prosthesis design. II. Simulation. J Biomed Mater Res A 1998; 39: 102-119.
    • (1998) J Biomed Mater Res A , vol.39 , pp. 102-119
    • Yildiz, H.1    Chang, F.K.2    Goodman, S.3
  • 61
    • 0029446705 scopus 로고
    • An estimation of fatigue life for a carbon fibre/poly ether ether ketone hip joint prosthesis
    • Akay M and Aslan N. An estimation of fatigue life for a carbon fibre/poly ether ether ketone hip joint prosthesis. Proc Inst Mech Eng H 1995; 229: 93-103.
    • (1995) Proc Inst Mech Eng H , vol.229 , pp. 93-103
    • Akay, M.1    Aslan, N.2
  • 62
    • 0030175796 scopus 로고    scopus 로고
    • Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis
    • Akay M and Aslan N. Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis. J Biomed Mater Res A 1996; 31: 167-182.
    • (1996) J Biomed Mater Res A , vol.31 , pp. 167-182
    • Akay, M.1    Aslan, N.2
  • 63
    • 0025073198 scopus 로고
    • New design of hip prosthesis using carbon fibre reinforced composite
    • Shirandami R and Esat II. New design of hip prosthesis using carbon fibre reinforced composite. J Biomech Eng 1990; 12: 19-22.
    • (1990) J Biomech Eng , vol.12 , pp. 19-22
    • Shirandami, R.1    Esat, I.I.2
  • 64
    • 0028450062 scopus 로고
    • Biomechanical and histomorphological investigations on an isoelastic hip prosthesis after an eight month implantation
    • Wilke HJ, Seiz RS, Bombelli M, Claes L, Durselen L. Biomechanical and histomorphological investigations on an isoelastic hip prosthesis after an eight month implantation. J Mater Sci Mater Med 1994; 5: 384-386.
    • (1994) J Mater Sci Mater Med , vol.5 , pp. 384-386
    • Wilke, H.J.1    Seiz, R.S.2    Bombelli, M.3    Claes, L.4    Durselen, L.5
  • 65
    • 0025453309 scopus 로고
    • Stiffness and strength tailoring of a hip prosthesis made of advanced composite materials
    • Chang FK, Perez JL, Davidson JA. Stiffness and strength tailoring of a hip prosthesis made of advanced composite materials. J Biom Mater Res A 1990; 24: 873-899.
    • (1990) J Biom Mater Res A , vol.24 , pp. 873-899
    • Chang, F.K.1    Perez, J.L.2    Davidson, J.A.3
  • 66
    • 0028501002 scopus 로고
    • Polyetherimide as biomaterial: Preliminary in vitro and in vivo biocompatibility testing
    • Peluso G, Petillo O, Ambrosio L, Nicolais L. Polyetherimide as biomaterial: preliminary in vitro and in vivo biocompatibility testing. J Mater Sci Mater Med 1994; 5: 738-742.
    • (1994) J Mater Sci Mater Med , vol.5 , pp. 738-742
    • Peluso, G.1    Petillo, O.2    Ambrosio, L.3    Nicolais, L.4
  • 70
    • 0033874840 scopus 로고    scopus 로고
    • Design of a controlledstiffness composite proximal femoral prosthesis
    • Simões JA, Marques T, Jeronimidis G. Design of a controlledstiffness composite proximal femoral prosthesis. Compos Sci Technol 2000; 60: 559-567.
    • (2000) Compos Sci Technol , vol.60 , pp. 559-567
    • Simões, J.A.1    Marques, T.2    Jeronimidis, G.3
  • 73
    • 0026217692 scopus 로고
    • Mandibular deformation in subjects with osseointegrated implants
    • Hobkirk JA, Schwab J. Mandibular deformation in subjects with osseointegrated implants. Int J Oral Maxillofac Implants 1991; 6: 319-328.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 319-328
    • Hobkirk, J.A.1    Schwab, J.2
  • 74
    • 0031994389 scopus 로고    scopus 로고
    • Mechanical properties of buccal compact bone of the mandibular ramus in human adults and children: Relationship of the elastic modulus to the direction of the osteon and the porosity ratio
    • Hara T, Takizawa M, Sato T, Ide Y. Mechanical properties of buccal compact bone of the mandibular ramus in human adults and children: relationship of the elastic modulus to the direction of the osteon and the porosity ratio. Bull Tokyo Dent Coll 1998; 39: 47-55.
    • (1998) Bull Tokyo Dent Coll , vol.39 , pp. 47-55
    • Hara, T.1    Takizawa, M.2    Sato, T.3    Ide, Y.4
  • 75
    • 0030132631 scopus 로고    scopus 로고
    • Properties of the elastic modulus from buccal compact bone of human mandible
    • Tamatsu Y, Kaimoto K, Arai M, Ide Y. Properties of the elastic modulus from buccal compact bone of human mandible. Bull Tokyo Dent Coll 1996; 37: 93-101.
    • (1996) Bull Tokyo Dent Coll , vol.37 , pp. 93-101
    • Tamatsu, Y.1    Kaimoto, K.2    Arai, M.3    Ide, Y.4
  • 77
    • 0033035173 scopus 로고    scopus 로고
    • Anisotropic mechanical properties of lamellar bone using miniature cantilever bending specimens
    • Liu D, Weiner S, Wagner HD. Anisotropic mechanical properties of lamellar bone using miniature cantilever bending specimens. J Biomech 1999; 32: 647-654.
    • (1999) J Biomech , vol.32 , pp. 647-654
    • Liu, D.1    Weiner, S.2    Wagner, H.D.3
  • 79
    • 0027551874 scopus 로고
    • Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
    • Rho JY, Ashman RB, Turner CH. Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements. J Biomech 1993; 26: 111-119.
    • (1993) J Biomech , vol.26 , pp. 111-119
    • Rho, J.Y.1    Ashman, R.B.2    Turner, C.H.3
  • 80
    • 0028502929 scopus 로고
    • Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus
    • Keaveny TM, Wachtel EF, Ford CM, Hayes WC. Differences between the tensile and compressive strengths of bovine tibial trabecular bone depend on modulus. J Biomech 1994; 9: 1137-1146.
    • (1994) J Biomech , vol.9 , pp. 1137-1146
    • Keaveny, T.M.1    Wachtel, E.F.2    Ford, C.M.3    Hayes, W.C.4
  • 81
    • 0034925754 scopus 로고    scopus 로고
    • Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic
    • Giesen EBW, Ding M, Dalstra M, van Eijden TMGJ. Mechanical properties of cancellous bone in the human mandibular condyle are anisotropic. J Biomech 2001; 34: 799-803.
    • (2001) J Biomech , vol.34 , pp. 799-803
    • Giesen, E.B.W.1    Ding, M.2    Dalstra, M.3    van Eijden, T.M.G.J.4
  • 82
    • 0033067941 scopus 로고    scopus 로고
    • Mechanical properties of trabecular bone in the human mandible: Implications for dental implant treatment planning and surgical placement
    • Misch CE, Qu Z, Bidez MW. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg 1999; 57: 700-706.
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 700-706
    • Misch, C.E.1    Qu, Z.2    Bidez, M.W.3
  • 83
    • 0034303223 scopus 로고    scopus 로고
    • Anisotropic elastic properties of cancellous bone from a human edentulous mandible
    • O'Mahony AM, Williams JL, Katz JO, Spencer P. Anisotropic elastic properties of cancellous bone from a human edentulous mandible. Clin Oral Implants Res 2000; 11: 415-421.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 415-421
    • O'Mahony, A.M.1    Williams, J.L.2    Katz, J.O.3    Spencer, P.4
  • 84
    • 0029329184 scopus 로고
    • Modelling of forces in the human masticatory system with optimization of the angulations of the joint loads
    • Trainor PGS, McLachlan KR, McCall WD. Modelling of forces in the human masticatory system with optimization of the angulations of the joint loads. J Biomech 1995; 28: 829-843.
    • (1995) J Biomech , vol.28 , pp. 829-843
    • Trainor, P.G.S.1    McLachlan, K.R.2    McCall, W.D.3
  • 85
    • 0034508992 scopus 로고    scopus 로고
    • Photoelastic analysis of bone deformation in the region of the mandibular condyle during mastication
    • Meyer C, Kahan JL, Lambert A, Boutemy P, Wilk A. Photoelastic analysis of bone deformation in the region of the mandibular condyle during mastication. J Craniomaxillofac Surg 2000; 28: 278-286.
    • (2000) J Craniomaxillofac Surg , vol.28 , pp. 278-286
    • Meyer, C.1    Kahan, J.L.2    Lambert, A.3    Boutemy, P.4    Wilk, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.