메뉴 건너뛰기




Volumn 31, Issue 2, 1996, Pages 167-182

Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis

Author keywords

[No Author keywords available]

Indexed keywords

BONE; CARBON FIBER REINFORCED PLASTICS; ELASTICITY; FINITE ELEMENT METHOD; INJECTION MOLDING; JOINTS (ANATOMY); MATHEMATICAL MODELS; POLYETHER ETHER KETONES; STRAIN; STRAIN GAGES; STRESS ANALYSIS; TITANIUM;

EID: 0030175796     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(199606)31:2<167::AID-JBM3>3.0.CO;2-L     Document Type: Article
Times cited : (89)

References (30)
  • 2
    • 0021470032 scopus 로고
    • Mechanical properties of Poly (ether-ether-ketone) for engineering applications
    • D. P. Jones, D. C. Leach, and D. R. Moore, "Mechanical properties of Poly (ether-ether-ketone) for engineering applications," Polymer, 26, 1385-1393 (1985).
    • (1985) Polymer , vol.26 , pp. 1385-1393
    • Jones, D.P.1    Leach, D.C.2    Moore, D.R.3
  • 4
    • 0020781968 scopus 로고
    • Environmental resistance of carbon fiber-reinforced poly ether ether ketone
    • F. N. Cogswell and M. Hopprich, "Environmental resistance of carbon fiber-reinforced poly ether ether ketone," Composites, 14, 251-253 (1983).
    • (1983) Composites , vol.14 , pp. 251-253
    • Cogswell, F.N.1    Hopprich, M.2
  • 5
    • 0021578894 scopus 로고
    • Characterization and exposure of poly ether ether ketone (PEEK) to fluid environments
    • E. J. Stober, J. C. Seferis, and J. D. Keenan, "Characterization and exposure of poly ether ether ketone (PEEK) to fluid environments," Polymer, 25, 1845-1852 (1984).
    • (1984) Polymer , vol.25 , pp. 1845-1852
    • Stober, E.J.1    Seferis, J.C.2    Keenan, J.D.3
  • 6
    • 84989701974 scopus 로고
    • Environmental effects on the water absorption and mechanical properties of carbon fiber reinforced PPS and PEEK composites
    • C. Ma and S. Yur, "Environmental effects on the water absorption and mechanical properties of carbon fiber reinforced PPS and PEEK composites," Polym. Eng. Sci., 31, 34-39 (1991).
    • (1991) Polym. Eng. Sci. , vol.31 , pp. 34-39
    • Ma, C.1    Yur, S.2
  • 7
    • 0004625392 scopus 로고
    • Carbon fiber reinforced PEEK (APC-2/AS-4) composites for orthopedic implants
    • K. B. Kwarteng and C. Stark, "Carbon fiber reinforced PEEK (APC-2/AS-4) composites for orthopedic implants," Sampe Quarterly, 22, 10-14 (1990).
    • (1990) Sampe Quarterly , vol.22 , pp. 10-14
    • Kwarteng, K.B.1    Stark, C.2
  • 8
    • 0023295470 scopus 로고
    • Potential of poly ether ether ketone (PEEK) carbon-fiber-reinforced PEEK in medical applications
    • D. F. Williams, A. McNamara, and R. M. Turner, "Potential of poly ether ether ketone (PEEK) carbon-fiber-reinforced PEEK in medical applications," J. Mater. Sci. Let., 6, 188-190 (1987).
    • (1987) J. Mater. Sci. Let. , vol.6 , pp. 188-190
    • Williams, D.F.1    McNamara, A.2    Turner, R.M.3
  • 9
    • 0025388769 scopus 로고
    • In vitro biocompatibility of poly ether ether ketone and polysulfone composites
    • L. M. Wenz, K. Merritt, A. Moet, and A. D. Steffe, "In vitro biocompatibility of poly ether ether ketone and polysulfone composites," J. Biomed. Mater. Res., 24, 207-215 (1990).
    • (1990) J. Biomed. Mater. Res. , vol.24 , pp. 207-215
    • Wenz, L.M.1    Merritt, K.2    Moet, A.3    Steffe, A.D.4
  • 11
    • 0023837335 scopus 로고
    • Effect of femoral component section modulus on the stress distribution in the proximal human femur
    • J. A. Engelhardt and S. Saha, "Effect of femoral component section modulus on the stress distribution in the proximal human femur," Med. Biol. Eng. Comp., 26, 38-45 (1988).
    • (1988) Med. Biol. Eng. Comp. , vol.26 , pp. 38-45
    • Engelhardt, J.A.1    Saha, S.2
  • 12
    • 0017837076 scopus 로고
    • Proximal strain distribution in the proximal femur
    • I. Oh and W. H. Harris, "Proximal strain distribution in the proximal femur," J. Bone Jt. Surg., 60-A, 75-85 (1978).
    • (1978) J. Bone Jt. Surg. , vol.60 A , pp. 75-85
    • Oh, I.1    Harris, W.H.2
  • 14
    • 0026311111 scopus 로고
    • Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance
    • J. A. Szivek and R. L. Gealer, "Comparison of the deformation response of synthetic and cadaveric femora during simulated one-legged stance," J. Appl. Biomater. 2, 277-280 (1991).
    • (1991) J. Appl. Biomater. , vol.2 , pp. 277-280
    • Szivek, J.A.1    Gealer, R.L.2
  • 15
    • 0026131363 scopus 로고
    • Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur
    • H. McKellop, E. Ebramzadeh, P. G. Niederer, and A. Sarmiento, "Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur," J. Orthop. Res. 9, 297-305 (1991).
    • (1991) J. Orthop. Res. , vol.9 , pp. 297-305
    • McKellop, H.1    Ebramzadeh, E.2    Niederer, P.G.3    Sarmiento, A.4
  • 16
    • 0024841727 scopus 로고
    • Materials selection in the artificial hip joint using finite element stress analysis
    • P. J. Prendergast, J. Monaghan, and D. Taylor, "Materials selection in the artificial hip joint using finite element stress analysis," Clin. Mater. 4, 361-376 (1989).
    • (1989) Clin. Mater. , vol.4 , pp. 361-376
    • Prendergast, P.J.1    Monaghan, J.2    Taylor, D.3
  • 17
    • 0019051541 scopus 로고
    • A measurement of proximal femur strain with total hip arthroplasty
    • R. D. Crowninshield, D. R. Pedersen, and R. A. Brand, "A measurement of proximal femur strain with total hip arthroplasty," J. Biomech. Eng. 102, 230-233 (1980).
    • (1980) J. Biomech. Eng. , vol.102 , pp. 230-233
    • Crowninshield, R.D.1    Pedersen, D.R.2    Brand, R.A.3
  • 19
    • 0024698077 scopus 로고
    • A review of the biomechanical properties of bone as a material
    • A. N. Natali and E. A. Merio, "A review of the biomechanical properties of bone as a material," J. Biomed. Eng., 11, 267-276 (1989).
    • (1989) J. Biomed. Eng. , vol.11 , pp. 267-276
    • Natali, A.N.1    Merio, E.A.2
  • 20
    • 0029446705 scopus 로고
    • An estimation of fatigue life for a carbon fiber/poly ether ether ketone hip joint prosthesis
    • M. Akay and N. Aslan, "An estimation of fatigue life for a carbon fiber/poly ether ether ketone hip joint prosthesis," Proc. Instn. Mech. Engrs., part H2, J. Eng. Med. 209, 93-103 (1995).
    • (1995) Proc. Instn. Mech. Engrs., Part H2, J. Eng. Med. , vol.209 , pp. 93-103
    • Akay, M.1    Aslan, N.2
  • 22
    • 0021412468 scopus 로고
    • Mechanical properties of bone cement
    • S. Saha and S. Pal, "Mechanical properties of bone cement," J. Biomed. Mater. Res., 18, 435-462 (1984).
    • (1984) J. Biomed. Mater. Res. , vol.18 , pp. 435-462
    • Saha, S.1    Pal, S.2
  • 23
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running measured in two patients
    • G. Bergmann, F. Graichen, and A. Rohlmann, "Hip joint loading during walking and running measured in two patients," J. Biomech. 26, 969-990 (1993).
    • (1993) J. Biomech. , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 25
    • 0026580011 scopus 로고
    • A finite element study of the initiation of failure of fixation in cemented femoral total hip components
    • T. P. Harrigan, J. A. Kareh, D. O. O'Connor, D. W Burke, and W. H. Harris, "A finite element study of the initiation of failure of fixation in cemented femoral total hip components," J. Orthop. Res., 10, 134-144 (1992).
    • (1992) J. Orthop. Res. , vol.10 , pp. 134-144
    • Harrigan, T.P.1    Kareh, J.A.2    O'Connor, D.O.3    Burke, D.W.4    Harris, W.H.5
  • 28
    • 0022886595 scopus 로고
    • Role of the collar on the femoral stem of cemented total hip replacements
    • M. J. Fagan and A. J. C. Lee, "Role of the collar on the femoral stem of cemented total hip replacements," J. Biomed. Eng., 8, 295-304 (1986).
    • (1986) J. Biomed. Eng. , vol.8 , pp. 295-304
    • Fagan, M.J.1    Lee, A.J.C.2
  • 29
    • 0001927136 scopus 로고
    • Material selection in the design of the femoral component of cemented total hip replacement
    • M. J. Fagan and A. J. C. Lee, "Material selection in the design of the femoral component of cemented total hip replacement," Clin. Mater. 1, 151-167 (1986).
    • (1986) Clin. Mater. , vol.1 , pp. 151-167
    • Fagan, M.J.1    Lee, A.J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.