1
-
-
0028208765
-
Early failures among 14009 cemented and 1326 uncemented prostheses for primary coarthrosis
-
Havelin LI, Espehaug B, Vollset SE, Engesaeter LB. Early failures among 14009 cemented and 1326 uncemented prostheses for primary coarthrosis. Acta Orthop Scand 1994;65:1-6.
-
(1994)
Acta Orthop Scand
, vol.65
, pp. 1-6
-
-
Havelin, L.I.1
Espehaug, B.2
Vollset, S.E.3
Engesaeter, L.B.4
-
2
-
-
0027715365
-
Failed innovation in total hip replacement: Diagnosis and proposals for a cure
-
Huiskes R. Failed innovation in total hip replacement: Diagnosis and proposals for a cure. Acta Orthop Scand 1993;64(6):699-716.
-
(1993)
Acta Orthop Scand
, vol.64
, Issue.6
, pp. 699-716
-
-
Huiskes, R.1
-
3
-
-
0020511389
-
Cementless fixation of 'isoelastic' hip endoprostheses manufactured from plastic materials
-
Morscher EW, Dick W. Cementless fixation of 'isoelastic' hip endoprostheses manufactured from plastic materials. Clin Orthop Rel Res 1983;176:77-87.
-
(1983)
Clin Orthop Rel Res
, vol.176
, pp. 77-87
-
-
Morscher, E.W.1
Dick, W.2
-
4
-
-
0023943537
-
The isoelastic hip prosthesis followed for 5 years
-
Butel J, Robb JE. The isoelastic hip prosthesis followed for 5 years. Acta Orthop Scand 1988;59:258-62.
-
(1988)
Acta Orthop Scand
, vol.59
, pp. 258-262
-
-
Butel, J.1
Robb, J.E.2
-
5
-
-
0026353010
-
In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis
-
Nistor L, Blaha JD, Kjellstrom U, Selvik G. In vivo measurements of relative motion between an uncemented femoral total hip component and the femur by roentgen stereophotogrammetric analysis. Clin Orthop 1991;269:220-7.
-
(1991)
Clin Orthop
, vol.269
, pp. 220-227
-
-
Nistor, L.1
Blaha, J.D.2
Kjellstrom, U.3
Selvik, G.4
-
6
-
-
0027249705
-
A prospective comparison of Butel and PCA hip arthroplasty
-
Jacobsson SA, Djerf K, Gillquist J, Hammerby S, Iversson I. A prospective comparison of Butel and PCA hip arthroplasty. J Bone Joint Surg 1993;75B:624-9.
-
(1993)
J Bone Joint Surg
, vol.75 B
, pp. 624-629
-
-
Jacobsson, S.A.1
Djerf, K.2
Gillquist, J.3
Hammerby, S.4
Iversson, I.5
-
7
-
-
0022454624
-
The isoelastic non-cemented total hip arthroplasty: Preliminary experience with 400 cases
-
Andrew TA, Flanagan JP, Gerundini M, Bombelli R. The isoelastic non-cemented total hip arthroplasty: preliminary experience with 400 cases. Clin Orthop Rel Res 1986;206:127-38.
-
(1986)
Clin Orthop Rel Res
, vol.206
, pp. 127-138
-
-
Andrew, T.A.1
Flanagan, J.P.2
Gerundini, M.3
Bombelli, R.4
-
8
-
-
0024341317
-
The 5 to 7 year follow-up results with the RM isoelastic hip prosthesis
-
Trager D. The 5 to 7 year follow-up results with the RM isoelastic hip prosthesis. Unfallchirurg 1989;92:301-4.
-
(1989)
Unfallchirurg
, vol.92
, pp. 301-304
-
-
Trager, D.1
-
9
-
-
0028213581
-
Total hip arthroplasty using isoelastic femoral stems. A seven-to-nine year follow-up in 108 patients
-
Niinimäki T, Puranen J, Jalovaara P. Total hip arthroplasty using isoelastic femoral stems. A seven-to-nine year follow-up in 108 patients. J Bone Joint Surg 1994;76B(3):413-8.
-
(1994)
J Bone Joint Surg
, vol.76 B
, Issue.3
, pp. 413-418
-
-
Niinimäki, T.1
Puranen, J.2
Jalovaara, P.3
-
10
-
-
0023398854
-
Development of a carbon-carbon hip prosthesis
-
Christel P, Meunier A, Leclerq S. Development of a carbon-carbon hip prosthesis. J Biomed Mater Res, Applied Biomaterials 1987;21(A2):191-218.
-
(1987)
J Biomed Mater Res, Applied Biomaterials
, vol.21
, Issue.A2
, pp. 191-218
-
-
Christel, P.1
Meunier, A.2
Leclerq, S.3
-
11
-
-
0028559553
-
Implant stability, histology, RSA and wear-more critical questions are needed: A viewpoint
-
Linder L. Implant stability, histology, RSA and wear-more critical questions are needed: a viewpoint. Acta Orthop Scand 1994;65:654-8.
-
(1994)
Acta Orthop Scand
, vol.65
, pp. 654-658
-
-
Linder, L.1
-
12
-
-
0022465758
-
Observations on the effect of movement on bone ingrowth into porous-surfaced implants
-
Pilliar RM, Lee JM, Maniatopoulos C. Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clin Orthop Rel Res 1986;208:103-8.
-
(1986)
Clin Orthop Rel Res
, vol.208
, pp. 103-108
-
-
Pilliar, R.M.1
Lee, J.M.2
Maniatopoulos, C.3
-
15
-
-
0000995485
-
Material stiffness optimization for a composite hip prosthesis
-
S Adali, VE Verijienko, editors Durban, South Africa, Department of Mechanical Engineering, University of Natal
-
Simões JAO, António CAC, Marques AT. Material stiffness optimization for a composite hip prosthesis. In: S Adali, VE Verijienko, editors. 1st International Conference on Composite Science and Technology, Durban, South Africa, Department of Mechanical Engineering, University of Natal, 1996. p. 477-82.
-
(1996)
1st International Conference on Composite Science and Technology
, pp. 477-482
-
-
Simões, J.A.O.1
António, C.A.C.2
Marques, A.T.3
-
16
-
-
0030406096
-
Comparison of conventional and hybrid modulus pres-fit proximal femoral prostheses
-
M Cerrolaza, D Jugo, CA Brebbia, editors Computational Mechanics Publications
-
Simões JA, Taylor M. Comparison of conventional and hybrid modulus pres-fit proximal femoral prostheses. In: M Cerrolaza, D Jugo, CA Brebbia, editors. Simulation modelling in bioengineering. Computational Mechanics Publications, 1996. p. 127-39.
-
(1996)
Simulation Modelling in Bioengineering
, pp. 127-139
-
-
Simões, J.A.1
Taylor, M.2
-
18
-
-
0024947002
-
Mathematical shape optimization of hip prosthesis design
-
Huiskes R, Boeklagen R. Mathematical shape optimization of hip prosthesis design. J Biomech 1989;22:793-804.
-
(1989)
J Biomech
, vol.22
, pp. 793-804
-
-
Huiskes, R.1
Boeklagen, R.2
-
19
-
-
0038529342
-
Three-dimensional shape optimization of femoral components of total hip prostheses
-
BED
-
Katoozian H, Davy DT. Three-dimensional shape optimization of femoral components of total hip prostheses. In: 1993 ASME Bioengineering Conference, BED, Vol. 24, 1993. p. 552-5.
-
(1993)
1993 ASME Bioengineering Conference
, vol.24
, pp. 552-555
-
-
Katoozian, H.1
Davy, D.T.2
-
21
-
-
0024943182
-
Shape optimal design of the stem of a cemented hip prosthesis to minimize stress concentration in the cemented layer
-
Yoon YS, Jang GH, Kim YY. Shape optimal design of the stem of a cemented hip prosthesis to minimize stress concentration in the cemented layer. J Biomech 1989;22(1/2):1279-84.
-
(1989)
J Biomech
, vol.22
, Issue.1-2
, pp. 1279-1284
-
-
Yoon, Y.S.1
Jang, G.H.2
Kim, Y.Y.3
-
22
-
-
0004704082
-
The development of CFRP based hip stems
-
ECCM-7, London
-
Davidson R, Brabon S, Lee RJ, Nelson K, Unwin P, Roughley P. The development of CFRP based hip stems. In: Proceedings of the 7th European conference on composite materials, ECCM-7, London, 1996. p. 513-17.
-
(1996)
Proceedings of the 7th European Conference on Composite Materials
, pp. 513-517
-
-
Davidson, R.1
Brabon, S.2
Lee, R.J.3
Nelson, K.4
Unwin, P.5
Roughley, P.6
-
23
-
-
0004698219
-
Injection moulding of carbon fibre reinforced PEEK for anisotropic hip-prostheses: Preliminary results
-
Porto
-
Widmer M, Callenbach T, Isler J, Fröhlich M, Meier D, Mayer J, et al. Injection moulding of carbon fibre reinforced PEEK for anisotropic hip-prostheses: Preliminary results. In: Proceedings of the III Portuguese Congress in Biomedical Engineering, Porto, 1995.
-
(1995)
Proceedings of the III Portuguese Congress in Biomedical Engineering
-
-
Widmer, M.1
Callenbach, T.2
Isler, J.3
Fröhlich, M.4
Meier, D.5
Mayer, J.6
-
24
-
-
0004704083
-
Orthopaedic composites
-
Lee SM, editor. New York
-
Devanathan D. Orthopaedic composites. In: Lee SM, editor. International encyclopedia of composites, Vol. 4. New York, 1991. p. 74-86.
-
(1991)
International Encyclopedia of Composites
, vol.4
, pp. 74-86
-
-
Devanathan, D.1
-
25
-
-
0025453309
-
Stiffness and strength tailoring of a hip prosthesis made of advanced composite materials
-
Chang F, Perez JL, Davidson JA. Stiffness and strength tailoring of a hip prosthesis made of advanced composite materials. Biomed Mater Res 1990;24:873-99.
-
(1990)
Biomed Mater Res
, vol.24
, pp. 873-899
-
-
Chang, F.1
Perez, J.L.2
Davidson, J.A.3
-
26
-
-
0039949146
-
Carbon fibre reinforced epoxy resin, a material for human implants
-
Düsseldorf: VDI-Verlag GmbH, Verlag des Vereins Deutscher Ingenieure
-
Scheer W. Carbon fibre reinforced epoxy resin, a material for human implants. In: Processing and uses of carbon fibre reinforced plastics. Düsseldorf: VDI-Verlag GmbH, Verlag des Vereins Deutscher Ingenieure, 1981. p. 251-76.
-
(1981)
Processing and Uses of Carbon Fibre Reinforced Plastics
, pp. 251-276
-
-
Scheer, W.1
-
27
-
-
0020909845
-
Experimental investigations on hip prostheses with carbon fibre reinforced carbon shafts and ceramic heads
-
P. Vincenzini, editor. Amsterdam
-
Claes I, Burri C, Neugebauer R, Gruber U. Experimental investigations on hip prostheses with carbon fibre reinforced carbon shafts and ceramic heads. In: P. Vincenzini, editor. Ceramics in Surgery. Amsterdam, 1983. p. 243-50.
-
(1983)
Ceramics in Surgery
, pp. 243-250
-
-
Claes, I.1
Burri, C.2
Neugebauer, R.3
Gruber, U.4
-
28
-
-
84992247748
-
-
US patent 3, 893, 196, 1975
-
Hochman RF. US patent 3, 893, 196, 1975.
-
-
-
Hochman, R.F.1
-
29
-
-
84992249110
-
-
US patent 4, 662, 887, 1987
-
Turner RM, et al. US patent 4, 662, 887, 1987.
-
-
-
Turner, R.M.1
-
30
-
-
0028756389
-
Effects of composite laminate lay-up configuration of a canine composite hip stem on bone strains
-
Fagan M, Aberman HM, Bushelow M, Lin RY, Dumbleton JH, DeYoung DJ, et alEffects of composite laminate lay-up configuration of a canine composite hip stem on bone strains. BED, Advances in Bioengineering, ASME 1994;28:445-6.
-
(1994)
BED, Advances in Bioengineering, ASME
, vol.28
, pp. 445-446
-
-
Fagan, M.1
Aberman, H.M.2
Bushelow, M.3
Lin, R.Y.4
Dumbleton, J.H.5
DeYoung, D.J.6
-
31
-
-
0023680250
-
A canine composite femoral stem
-
Magee FP, Weinstein AM, Longo JA, Koeneman JB, Yapp RA. A canine composite femoral stem. Clin Orthop Rel Res 1988;235:237-52.
-
(1988)
Clin Orthop Rel Res
, vol.235
, pp. 237-252
-
-
Magee, F.P.1
Weinstein, A.M.2
Longo, J.A.3
Koeneman, J.B.4
Yapp, R.A.5
-
32
-
-
0040542005
-
Development of a controlled stiffness composite femoral prosthesis
-
CR Gentle, JB Hull, editors. Nottingham, United Kingdom
-
Simoes JA, Vaz MA, Marques AT, Silva Gomes J. Development of a controlled stiffness composite femoral prosthesis. In: CR Gentle, JB Hull, editors. Mechanics in design '98, Nottingham, United Kingdom, 1998. p. 600-8.
-
(1998)
Mechanics in Design '98
, pp. 600-608
-
-
Simoes, J.A.1
Vaz, M.A.2
Marques, A.T.3
Silva Gomes, J.4
-
34
-
-
0029380382
-
Cancelous bone stresses surrounding the femoral component of a hip prosthesis: An elastic-plastic finite element analysis
-
Taylor M, Tanner KE, Freeman MAR, Yettram AL. Cancelous bone stresses surrounding the femoral component of a hip prosthesis: an elastic-plastic finite element analysis. Med Eng Phys 1995;17:544-50.
-
(1995)
Med Eng Phys
, vol.17
, pp. 544-550
-
-
Taylor, M.1
Tanner, K.E.2
Freeman, M.A.R.3
Yettram, A.L.4
-
35
-
-
0030987956
-
Fatigue failure of cancellous bone: A possible cause of implant migration and loosening
-
Taylor M, Tanner E. Fatigue failure of cancellous bone: a possible cause of implant migration and loosening. J Bone Joint Surg 1997;79B:181-2.
-
(1997)
J Bone Joint Surg
, vol.79 B
, pp. 181-182
-
-
Taylor, M.1
Tanner, E.2
-
36
-
-
0025642527
-
Stress pattern around femoral stems
-
Huiskes R. Stress pattern around femoral stems. Clin Orthop Rel Res 1990;261:27-37.
-
(1990)
Clin Orthop Rel Res
, vol.261
, pp. 27-37
-
-
Huiskes, R.1
-
37
-
-
0028282143
-
Early migration and late aseptic failure of proximal femoral prostheses
-
Freeman MAR, Plante-Bordeneuve P. Early migration and late aseptic failure of proximal femoral prostheses. J Bone Joint Surg 1994;76B:432-8.
-
(1994)
J Bone Joint Surg
, vol.76 B
, pp. 432-438
-
-
Freeman, M.A.R.1
Plante-Bordeneuve, P.2
-
39
-
-
0029135432
-
Prediction of clinical outcome of THR from migration measurements on standard radiographs
-
Walker PS, Mai SF, Cobb AG, Bentley G, Hua J. Prediction of clinical outcome of THR from migration measurements on standard radiographs. J Bone Joint Surg 1995;77B:705-14.
-
(1995)
J Bone Joint Surg
, vol.77 B
, pp. 705-714
-
-
Walker, P.S.1
Mai, S.F.2
Cobb, A.G.3
Bentley, G.4
Hua, J.5
-
40
-
-
0026848765
-
The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
-
Linde F, Hvid I, Madsen F. The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens. J Biomech 1992;25:359-68.
-
(1992)
J Biomech
, vol.25
, pp. 359-368
-
-
Linde, F.1
Hvid, I.2
Madsen, F.3
-
41
-
-
0027574980
-
Compressive fatigue behaviour of bovine trabecular bone
-
Michel MC, Gou XE, Gibson LJ, McMahou TA, Hayes WC. Compressive fatigue behaviour of bovine trabecular bone. J Biomech 1994;26:453-63.
-
(1994)
J Biomech
, vol.26
, pp. 453-463
-
-
Michel, M.C.1
Gou, X.E.2
Gibson, L.J.3
McMahou, T.A.4
Hayes, W.C.5
|