Volumn 38, Issue 7, 2011, Pages 4440-4450

Overestimations in zero frequency DQE of x-ray imaging converters assessed by Monte Carlo techniques based on the study of energy impartation events

Author keywords

DQE; Monte Carlo; radiation detectors

Indexed keywords

CESIUM IODIDE; COMPTON SCATTERING; DEPOSITION; LIGHT EMISSION; MEDICAL IMAGING; MONTE CARLO METHODS; PHOSPHORS; PHOTONS; QUANTUM EFFICIENCY; RADIATION DETECTORS;

EID: 79960205540     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3603190     Document Type: Article
Times cited : (12)

References (38)
  • 1
    • 0031029041 scopus 로고    scopus 로고
    • X-ray detectors for digital radiography
    • DOI 10.1088/0031-9155/42/1/001, PII S0031915597360904
    • M. J. Yaffe and J. A. Rowlands, " X-ray detectors for digital radiography.," Phys. Med. Biol. 42, 1-39 (1997). 10.1088/0031-9155/42/1/001 (Pubitemid 27055950)
    • (1997) Physics in Medicine and Biology , vol.42 , Issue.1 , pp. 1-39
    • Yaffe, M.J.1    Rowlands, J.A.2
  • 2
    • 0025156138 scopus 로고
    • Model of the spatial-frequency-dependent detective quantum efficiency of phosphor screens
    • DOI 10.1118/1.596583
    • R. M. Nishikawa and M. J. Yaffe, " Model of the spatial-frequency- dependent detective quantum efficiency of phosphor screens.," Med. Phys. 17, 894-904 (1990). 10.1118/1.596583 (Pubitemid 20353769)
    • (1990) Medical Physics , vol.17 , Issue.5 , pp. 894-904
    • Nishikawa, R.M.1    Yaffe, M.J.2
  • 3
    • 0033461146 scopus 로고    scopus 로고
    • Detective quantum efficiency dependence on x-ray energy weighting in mammography
    • DOI 10.1118/1.598807
    • R. N. Cahn, B. Cederström, M. Danielsson, A. Hall, M. Lundqvist, and D. Nygren, " Detective quantum efficiency dependence on x-ray energy weighting in mammography.," Med. Phys. 26, 2680-2683 (1999). 10.1118/1.598807 (Pubitemid 30007713)
    • (1999) Medical Physics , vol.26 , Issue.12 , pp. 2680-2683
    • Cahn, R.N.1    Cederstrom, B.2    Danielsson, M.3    Hall, A.4    Lundqvist, M.5    Nygren, D.6
  • 4
    • 0035129142 scopus 로고    scopus 로고
    • Role of the activator in the performance of scintillators used in X-ray imaging
    • DOI 10.1016/S0969-8043(00)00336-5, PII S0969804300003365
    • I. Kandarakis and D. Cavouras, " Role of the activator in the performance of scintillators used in X-ray imaging.," Appl. Radiat. Isot. 54, 821-831 (2001). 10.1016/S0969-8043(00)00336-5 (Pubitemid 32146457)
    • (2001) Applied Radiation and Isotopes , vol.54 , Issue.5 , pp. 821-831
    • Kandarakis, I.1    Cavouras, D.2
  • 5
    • 0041875087 scopus 로고    scopus 로고
    • Differences between mono- and poly-energetic spectra in modeling DQE(f)
    • 10.1117/12.480480
    • R. M. Nishikawa, " Differences between mono- and poly-energetic spectra in modeling DQE(f).," Proc. SPIE 5030, 871-876 (2003). 10.1117/12.480480
    • (2003) Proc. SPIE , vol.5030 , pp. 871-876
    • Nishikawa, R.M.1
  • 7
    • 33646445629 scopus 로고    scopus 로고
    • Screen optics effects on detective quantum efficiency in digital radiography: Zero-frequency effects
    • 10.1118/1.2188082
    • A. R. Lubinsky, W. Zhao, G. Ristic, and J. A. Rowlands, " Screen optics effects on detective quantum efficiency in digital radiography: Zero-frequency effects.," Med. Phys. 33, 1499-1509 (2006). 10.1118/1.2188082
    • (2006) Med. Phys. , vol.33 , pp. 1499-1509
    • Lubinsky, A.R.1    Zhao, W.2    Ristic, G.3    Rowlands, J.A.4
  • 8
    • 18844408570 scopus 로고    scopus 로고
    • Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors
    • DOI 10.1118/1.1901203
    • S. Richard, J. H. Siewerdsen, D. A. Jaffray, D. J. Moseley, and B. Bakhtiar, " Generalized DQE analysis of radiographic and dual-energy imaging using flat-panel detectors.," Med. Phys. 32, 1397-1413 (2005). 10.1118/1.1901203 (Pubitemid 40695783)
    • (2005) Medical Physics , vol.32 , Issue.5 , pp. 1397-1413
    • Richard, S.1    Siewerdsen, J.H.2    Jaffray, D.A.3    Moseley, D.J.4    Bakhtiar, B.5
  • 10
    • 33846372609 scopus 로고    scopus 로고
    • Impact of additive noise on system performance of a digital X-ray imaging system
    • DOI 10.1109/TBME.2006.886619, 11
    • D. Zhang, J. Rong, W. R. Chen, F. Gao, K. Xu, X. Wu, and H. Liu, " Impact of additive noise on system performance of a digital X-ray imaging system.," IEEE Trans. Biomed. Eng. 54, 69-73 (2007). 10.1109/TBME.2006. 884643 (Pubitemid 46127139)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.1 , pp. 69-73
    • Zhang, D.1    Rong, J.2    Chen, W.R.3    Gao, F.4    Xu, K.5    Wu, X.6    Liu, H.7
  • 11
    • 66749147327 scopus 로고    scopus 로고
    • Extension of DQE to include scatter, grid, magnification, and focal spot brur: A new experimental technique and metric
    • N. T. Ranger, A. Mackenzie, J. T. Dobbinsiii, C. E. Ravin, and E. Samei, " Extension of DQE to include scatter, grid, magnification, and focal spot brur: A new experimental technique and metric.," Proc. SPIE 7258, 42-52 (2009).
    • (2009) Proc. SPIE , vol.7258 , pp. 42-52
    • Ranger, N.T.1    MacKenzie, A.2    Dobbinsiii, J.T.3    Ravin, C.E.4    Samei, E.5
  • 13
    • 14644403625 scopus 로고    scopus 로고
    • Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic system
    • DOI 10.1118/1.1844151
    • I. S. Kyprianou, S. Rudin, R. Bednarek, and K. R. Hoffman, " Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic system.," Med. Phys. 32, 613-623 (2005). 10.1118/1.1844151 (Pubitemid 40322343)
    • (2005) Medical Physics , vol.32 , Issue.2 , pp. 613-626
    • Kyprianou, I.S.1    Rudin, S.2    Bednarek, D.R.3    Hoffmann, K.R.4
  • 14
    • 0035110309 scopus 로고    scopus 로고
    • Effects of x-ray spectra on the DQE of a computed radiography system
    • DOI 10.1118/1.1339883
    • K. A. Fetterly and N. J. Hangiandreou, " Effects of x-ray spectra on the DQE of a computed radiography system.," Med. Phys. 28, 241-249 (2001). 10.1118/1.1339883 (Pubitemid 32165762)
    • (2001) Medical Physics , vol.28 , Issue.2 , pp. 241-249
    • Fetterly, K.A.1    Hangiandreou, N.J.2
  • 15
    • 0034088964 scopus 로고    scopus 로고
    • Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications
    • DOI 10.1118/1.598831
    • L. E. Antonuk, K. W. Jee, Y. El-Mohri, M. Maolinbay, S. Naddif, X. Rong, Q. Zhao, and J. H. Siewerdsen " Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.," Med. Phys. 27, 289-306 (2000). 10.1118/1.598831 (Pubitemid 30117484)
    • (2000) Medical Physics , vol.27 , Issue.2 , pp. 289-306
    • Antonuk, L.E.1    Jee, K.-W.2    El-Mohri, Y.3    Maolinbay, M.4    Nassif, S.5    Rong, X.6    Zhao, Q.7    Siewerdsen, J.H.8    Street, R.A.9    Shah, K.S.10
  • 16
    • 0022577683 scopus 로고
    • Optical factors affecting the detective quantum efficiency of radiographic screens
    • DOI 10.1118/1.595939
    • M. Drangova and J. A. Rowlands, " Optical factors affecting the detective quantum efficiency of radiographic screens.," Med. Phys. 13, 150-157 (1986). 10.1118/1.595939 (Pubitemid 16113438)
    • (1986) Medical Physics , vol.13 , Issue.2 , pp. 150-157
    • Drangova, M.1    Rowlands, J.A.2
  • 17
    • 0021354483 scopus 로고
    • Studies of x-ray energy absorption and quantum noise properties of x-ray screens by use of Monte Carlo simulation
    • DOI 10.1118/1.595474
    • H.-P. Chan and K. Doi, " Studies of x-ray energy absorption and quantum noise properties of x-ray screens by use of Monte Carlo simulation.," Med. Phys. 11, 37-46 (1984). 10.1118/1.595474 (Pubitemid 14151271)
    • (1984) Medical Physics , vol.11 , Issue.1 , pp. 37-46
    • Chan, H.P.1    Doi, K.2
  • 18
    • 0026665727 scopus 로고
    • Influence of x-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography
    • 10.1088/0031-9155/37/6/004
    • M. Sandborg and G. A. Carlsson, " Influence of x-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography.," Phys. Med. Biol. 37, 1245-1263 (1992). 10.1088/0031-9155/37/6/004
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1245-1263
    • Sandborg, M.1    Carlsson, G.A.2
  • 19
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad spectrum x-ray imaging
    • DOI 10.1088/0031-9155/30/6/002
    • M. J. Tapiovaara and R. F. Wagner, " SNR and DQE analysis of broad spectrum x-ray imaging.," Phys. Med. Biol. 30, 519-529 (1985). 10.1088/0031-9155/30/6/002 (Pubitemid 15041525)
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.6 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.F.2
  • 20
    • 0029144630 scopus 로고
    • Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography
    • 10.1118/1.597593
    • D. A. Jaffray, J. J. Battista, A. Fenster, and P. Munro, " Monte Carlo studies of x-ray energy absorption and quantum noise in megavoltage transmission radiography.," Med. Phys. 22, 1077-1088 (1995). 10.1118/1.597593
    • (1995) Med. Phys. , vol.22 , pp. 1077-1088
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 21
    • 0024264809 scopus 로고
    • The influence of the single-event energy-deposition distribution on the signal-to-noise ratio in x-ray images in the presence of scattered radiation
    • P. Spanne, " The influence of the signal-event energy-deposition distribution on the signal-to-noise ratio in x-ray images in the presence of scattered radiation.," Phys. Med. Biol. 33, 1349-1358 (1988). 10.1088/0031-9155/33/12/001 (Pubitemid 19021431)
    • (1988) Physics in Medicine and Biology , vol.33 , Issue.12 , pp. 1349-1358
    • Spanne, P.1
  • 22
  • 24
    • 66449129236 scopus 로고    scopus 로고
    • 3: Eu powdered phosphor screens: Monte Carlo simulation for applications in mammography
    • 10.1118/1.3121423
    • 3: Eu powdered phosphor screens: Monte Carlo simulation for applications in mammography.," Med. Phys. 36, 1985-1997 (2009). 10.1118/1.3121423
    • (2009) Med. Phys. , vol.36 , pp. 1985-1997
    • Liaparinos, P.1    Kandarakis, I.2
  • 25
    • 0019497908 scopus 로고
    • Image information transfer properties of x-ray fluorescent screens
    • DOI 10.1118/1.594836
    • C. E. Dick and J. W. Motz, " Image information transfer properties of x-ray fluorescent screens.," Med. Phys. 8, 337-346 (1981). 10.1118/1.594836 (Pubitemid 11111020)
    • (1981) Medical Physics , vol.8 , Issue.3 , pp. 337-346
    • Dick, C.E.1    Motz, J.W.2
  • 26
    • 0015667930 scopus 로고
    • Absorption and noise in x-ray phosphors
    • 10.1063/1.1663834
    • R. K. Swank, " Absorption and noise in x-ray phosphors.," J. Appl. Phys. 45, 4199-4203 (1974). 10.1063/1.1663834
    • (1974) J. Appl. Phys. , vol.45 , pp. 4199-4203
    • Swank, R.K.1
  • 27
    • 0035989948 scopus 로고    scopus 로고
    • Direct conversion detectors: The effect of incomplete charge collection on detective quantum efficiency
    • DOI 10.1118/1.1477235
    • J. G. Mainprize, D. C. Hunt, and M. J. Yaffe, " Direct conversion detectors: The effect of incomplete charge collection on detective quantum efficiency.," Med. Phys. 29, 976-990 (2002). 10.1118/1.1477235 (Pubitemid 34670524)
    • (2002) Medical Physics , vol.29 , Issue.6 , pp. 976-990
    • Mainprize, J.G.1    Hunt, D.C.2    Yaffe, M.J.3
  • 28
    • 4644293266 scopus 로고    scopus 로고
    • X-ray imaging performance of structured cesium iodide scintillators
    • DOI 10.1118/1.1782676
    • W. Zhao, G. Ristic, and J. A. Rowlands, " X-ray imaging performance of structured cesium iodide scintillators.," Med. Phys. 31, 2594-2605 (2004). 10.1118/1.1782676 (Pubitemid 39287876)
    • (2004) Medical Physics , vol.31 , Issue.9 , pp. 2594-2605
    • Zhao, W.1    Ristic, G.2    Rowlands, J.A.3
  • 29
    • 0031439126 scopus 로고    scopus 로고
    • Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency
    • DOI 10.1118/1.598097
    • W. Zhao and J. A. Rowlands, " Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiency.," Med. Phys. 24, 1819-1833 (1997). 10.1118/1.598097 (Pubitemid 28013497)
    • (1997) Medical Physics , vol.24 , Issue.12 , pp. 1819-1833
    • Zhao, W.1    Rowlands, J.A.2
  • 30
    • 63649099292 scopus 로고    scopus 로고
    • The Monte evaluation of noise and resolution properties of granular phosphor screens
    • 10.1088/0031-9155/54/4/003
    • P. Liaparinos and I. Kandarakis, " The Monte evaluation of noise and resolution properties of granular phosphor screens.," Phys. Med. Biol. 54, 859-874 (2009). 10.1088/0031-9155/54/4/003
    • (2009) Phys. Med. Biol. , vol.54 , pp. 859-874
    • Liaparinos, P.1    Kandarakis, I.2
  • 31
    • 0020680912 scopus 로고
    • The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology
    • H. P. Chan and K. Doi, " The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology.," Phys. Med. Biol. 28, 109-129 (1983). 10.1088/0031-9155/28/2/001 (Pubitemid 13179730)
    • (1983) Physics in Medicine and Biology , vol.28 , Issue.2 , pp. 109-129
    • Chan, H.P.1    Doi, K.2
  • 32
    • 0020575045 scopus 로고
    • Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen-film systems
    • H. P. Chan and K. Doi, " Energy and angular dependence of x-ray absorption and its effect on radiographic response in screen-film systems.," Phys. Med. Biol. 28, 565-579 (1983). 10.1088/0031-9155/28/5/009 (Pubitemid 13123043)
    • (1983) Physics in Medicine and Biology , vol.28 , Issue.5 , pp. 565-579
    • Chan, H.P.1    Doi, K.2
  • 34
    • 0031834088 scopus 로고    scopus 로고
    • X-ray imaging using amorphous selenium: Determination of Swank factor by pulse height spectroscopy
    • DOI 10.1118/1.598245
    • I. M. Blevis, D. C. Hunt, and J. A. Rowlands, " X-ray imaging using amorphous selenium: Determination of Swank factor by pulse height spectroscopy.," Med. Phys. 25, 638-641 (1998). 10.1118/1.598245 (Pubitemid 28234882)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 638-641
    • Blevis, I.M.1    Hunt, D.C.2    Rowlands, J.A.3
  • 35
    • 0028917934 scopus 로고
    • X-ray imaging with amorphous selenium: Detective quantum efficiency of photoconductive receptors for digital mammography
    • 10.1118/1.597599
    • R. Fahrig, J. A. Rowlands, and M. J. Yaffe, " X-ray imaging with amorphous selenium: Detective quantum efficiency of photoconductive receptors for digital mammography.," Med. Phys. 22, 153-160 (1995). 10.1118/1.597599
    • (1995) Med. Phys. , vol.22 , pp. 153-160
    • Fahrig, R.1    Rowlands, J.A.2    Yaffe, M.J.3
  • 36
    • 46149085661 scopus 로고    scopus 로고
    • Fundamental x-ray interaction limits in diagnostic imaging detectors: Frequency-dependent Swank noise
    • DOI 10.1118/1.2936412
    • G. Hajdok, J. J. Battista, and I. A. Cunningham, " Fundamental x-ray interaction limits in diagnostic imaging detectors: Frequency-dependent Swank noise.," Med. Phys. 35, 3194-3204 (2008). 10.1118/1.2936412 (Pubitemid 351904523)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3194-3204
    • Hajdok, G.1    Battista, J.J.2    Cunningham, I.A.3
  • 37
    • 33646485572 scopus 로고    scopus 로고
    • A comparison between objective and subjective image quality measurements for a full field digital mammography system
    • 10.1088/0031-9155/51/10/006
    • N. W. Marshall, " A comparison between objective and subjective image quality measurements for a full field digital mammography system.," Phys. Med. Biol. 51, 2441-2463 (2006). 10.1088/0031-9155/51/10/006
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2441-2463
    • Marshall, N.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.