메뉴 건너뛰기




Volumn 54, Issue 5, 2001, Pages 821-831

Role of the activator in the performance of scintillators used in X-ray imaging

Author keywords

DQE; Medical scintillators; MTF; Phosphor screens; Scintillator efficiency

Indexed keywords

PHOSPHORUS;

EID: 0035129142     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(00)00336-5     Document Type: Article
Times cited : (20)

References (40)
  • 2
    • 0001770929 scopus 로고
    • Physical characteristics of screen-film combination
    • Haus, A.G. (Ed.), The Physics of Medical Imaging: Recording System, Measurements and Techniques. American Association of Physicists in Medicine, New York
    • (1979) , pp. 30-71
    • Arnold, B.A.1
  • 9
    • 0002178301 scopus 로고
    • Luminescent screens, the radiographic image
    • Lea, Febiger (Ed.,) Christensen's Physics of Diagnostic Radiology. London
    • (1990) , pp. 118-136
    • Curry, T.S.1    Dowdey, J.E.2    Murry, R.C.3
  • 10
    • 0002611183 scopus 로고
    • Detective quantum efficiency signal to noise ratio and the noise-equivalent number of quanta
    • Image science. Academic Press, New York
    • (1974) , pp. 152-188
    • Dainty, J.C.1    Shaw, R.2
  • 16
    • 0006204213 scopus 로고
    • Basic principles of computed-tomography detectors
    • Newton, T.H., Potts, D.G. (Eds.), Radiology of the Skull and Brain Technical Aspects of Computed Tomography. C.V. Mosby Company, St. Louis, 4103 pp
    • (1981)
    • Haque, P.1    Stanley, J.H.2
  • 22
    • 0006137320 scopus 로고
    • X-ray image intensifiers
    • Haus, A.G. (Ed.), The Physics of Medical Imaging Recording System Measurements and Techniques. American Association of Physicists in Medicine, New York
    • (1979) , pp. 182-205
    • Mistretta, C.A.1
  • 23
    • 0033983981 scopus 로고    scopus 로고
    • Signal-to-noise ratio and spatial resolution in X-ray electronic imagers: Is the MTF a relevant parameter?
    • (2000) Med. Phys. , vol.27 , pp. 86
    • Moy, J.P.1
  • 24
    • 0031471433 scopus 로고    scopus 로고
    • Integrated digital radiography with a flat electronic detector
    • (1997) Medicamundi. , vol.41 , pp. 14
    • Neitzel, U.1
  • 30
    • 0003604206 scopus 로고
    • Photon cross-sections from 0.001 to 100 MeV for elements 1 through 100
    • Los Alamos Scientific Laboratory, University of California
    • (1967) Report LA-3753
    • Storm, E.1    Israel, H.2
  • 31
    • 0015655012 scopus 로고
    • Calculation of modulation transfer functions of X-ray fluorescent screens
    • (1973) Appl. Opt. , vol.12 , pp. 1865
    • Swank, R.K.1
  • 34
    • 0006084557 scopus 로고
    • Light Scattering by Small Particles. Wiley, New York
    • (1957) , pp. 103-107
    • Van de Hulst, H.C.1
  • 35
    • 0026585446 scopus 로고
    • Describing the signal-transfer characteristics of asymmetrical radiographic screen-film systems
    • (1992) Med. Phys. , vol.19 , pp. 53
    • Van Metter, R.1
  • 36
    • 0025191057 scopus 로고
    • An application of multivariate moment-generating functions to the analysis of signal and noise propagation in radiographic screen-film systems
    • (1990) Med. Phys. , vol.17 , pp. 65
    • Van Metter, R.1    Rabbani, M.2
  • 37
    • 0034068552 scopus 로고    scopus 로고
    • Full breast digital mammography with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype
    • (2000) Med. Phys. , vol.27 , pp. 558
    • Vedantham, S.1    Karellas, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.