-
1
-
-
0015319816
-
Arthroplastie totale de hanche par prothese en alumine frittee
-
Boutin P. Arthroplastie totale de hanche par prothese en alumine frittee. Rev Chirol Orthop. 1972;58:229-246.
-
(1972)
Rev Chirol Orthop
, vol.58
, pp. 229-246
-
-
Boutin, P.1
-
2
-
-
2442507670
-
Stripe Wear Rates in Alumina THR. Comparison of Microseparation Simulator Study with Retrieved Implants
-
doi:10.1002/jbm.b.20033
-
Manaka M, Clarke IC, Yamamoto K, Shishido T, Gustafson A, Imakiire A. Stripe Wear Rates in Alumina THR. Comparison of Microseparation Simulator Study with Retrieved Implants. J Biomed Mater Res B Appl Biomater. 2004;69B(2):149-157. doi:10.1002/jbm.b.20033
-
(2004)
J Biomed Mater Res B Appl Biomater
, vol.69 B
, Issue.2
, pp. 149-157
-
-
Manaka, M.1
Clarke, I.C.2
Yamamoto, K.3
Shishido, T.4
Gustafson, A.5
Imakiire, A.6
-
3
-
-
0030293931
-
Wear behaviour of alumina toughened zirconia materials
-
doi:10.1016/0043-1648(96)07221-3
-
Cherif K, Gueroult B, Rigaud M. Wear behaviour of alumina toughened zirconia materials. Wear. 1996;199(1):113-121. doi:10.1016/0043-1648(96)07221-3
-
(1996)
Wear
, vol.199
, Issue.1
, pp. 113-121
-
-
Cherif, K.1
Gueroult, B.2
Rigaud, M.3
-
4
-
-
0034524599
-
The evolution of ceramics in total hip replacement
-
Willmann G. The evolution of ceramics in total hip replacement. Hip Int. 2000;10:193-203.
-
(2000)
Hip Int
, vol.10
, pp. 193-203
-
-
Willmann, G.1
-
5
-
-
0032450192
-
Surface replacement: The hip replacement of the future?
-
Amstutz HC, Sparling EA, Grigoris P, Campbell PA, Dorey FJ. Surface replacement: the hip replacement of the future? Hip Int. 1998;8(2):187-207.
-
(1998)
Hip Int
, vol.8
, Issue.2
, pp. 187-207
-
-
Amstutz, H.C.1
Sparling, E.A.2
Grigoris, P.3
Campbell, P.A.4
Dorey, F.J.5
-
6
-
-
79960041894
-
On the specifications for the use of bioinert ceramics in total hip replacement
-
In: Oonishi H, Aoki H, Sawai K, eds, St Louis: Euroamerica, Inc
-
Christel P, Dorlot JM, Meunier A. On the specifications for the use of bioinert ceramics in total hip replacement. In: Oonishi H, Aoki H, Sawai K, eds. Bioceramics. St Louis: Euroamerica, Inc.; 1989;1:262-266.
-
(1989)
Bioceramics
, vol.1
, pp. 262-266
-
-
Christel, P.1
Dorlot, J.M.2
Meunier, A.3
-
7
-
-
0024986155
-
Anatomical ceramic arthroplasty (AN.C.A.): Preliminary experience with a new cementless prosthesis
-
Medline
-
Toni A, Sudanese A, Ciaroni D, Dallari D, Greggi T, Giunti A. Anatomical ceramic arthroplasty (AN.C.A.): preliminary experience with a new cementless prosthesis. Chir Organi Mov. 1990;75(1):81-97. Medline.
-
(1990)
Chir Organi Mov
, vol.75
, Issue.1
, pp. 81-97
-
-
Toni, A.1
Sudanese, A.2
Ciaroni, D.3
Dallari, D.4
Greggi, T.5
Giunti, A.6
-
8
-
-
0035063689
-
In vivo determination of hip joint separation and the forces generated due to impact loading conditions
-
Medline. doi:10.1016/S0021- 9290(00)00239-6
-
Dennis DA, Komistek RD, Northcut EJ, Ochoa JA, Ritchie A. In vivo determination of hip joint separation and the forces generated due to impact loading conditions. J Biomech. 2001;34(5):623-629. Medline. doi:10.1016/S0021- 9290(00)00239-6
-
(2001)
J Biomech
, vol.34
, Issue.5
, pp. 623-629
-
-
Dennis, D.A.1
Komistek, R.D.2
Northcut, E.J.3
Ochoa, J.A.4
Ritchie, A.5
-
9
-
-
0036796360
-
In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty
-
Medline
-
Komistek RD, Dennis DA, Ochoa JA, Haas BD, Hammill C. In vivo comparison of hip separation after metal-on-metal or metal-on-polyethylene total hip arthroplasty. J Bone Joint Surg (Am). 2002;84-A:1836-1841. Medline.
-
(2002)
J Bone Joint Surg (Am)
, vol.84
, Issue.A
, pp. 1836-1841
-
-
Komistek, R.D.1
Dennis, D.A.2
Ochoa, J.A.3
Haas, B.D.4
Hammill, C.5
-
10
-
-
0033814112
-
An in vivo determination of total hip arthroplasty pistoning during activity
-
Medline. doi:10.1054/arth.2000.6637
-
Lombardi AV, Mallory TH, Dennis DA, Komistek RD, Fada RA, Northcut EJ. An in vivo determination of total hip arthroplasty pistoning during activity. J Arthroplasty. 2000;15(6):702-709. Medline. doi:10.1054/arth.2000.6637
-
(2000)
J Arthroplasty
, vol.15
, Issue.6
, pp. 702-709
-
-
Lombardi, A.V.1
Mallory, T.H.2
Dennis, D.A.3
Komistek, R.D.4
Fada, R.A.5
Northcut, E.J.6
-
11
-
-
0035735537
-
Contact mechanics of a novel metal-on-metal total hip replacement
-
Medline. doi:10.1243/0954411011536145
-
Besong AA, Lee R, Farrar R, Jin ZM. Contact mechanics of a novel metal-on-metal total hip replacement. Proc Inst Mech Eng H. 2001;215(6):543-548. Medline. doi:10.1243/0954411011536145
-
(2001)
Proc Inst Mech Eng H
, vol.215
, Issue.6
, pp. 543-548
-
-
Besong, A.A.1
Lee, R.2
Farrar, R.3
Jin, Z.M.4
-
12
-
-
0033814067
-
Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns
-
Medline. doi:10.1054/arth.2000.8100
-
Nevelos J, Ingham E, Doyle C, et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. J Arthroplasty. 2000;15(6):793-795. Medline. doi:10.1054/arth.2000.8100
-
(2000)
J Arthroplasty
, vol.15
, Issue.6
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
-
13
-
-
0036054006
-
Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements
-
Medline. doi:10.1243/095441102321032193
-
Mak MM, Besong AA, Jin ZM, Fisher J. Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements. Proc Inst Mech Eng H. 2002;216(6):403-408. Medline. doi:10.1243/095441102321032193
-
(2002)
Proc Inst Mech Eng H
, vol.216
, Issue.6
, pp. 403-408
-
-
Mak, M.M.1
Besong, A.A.2
Jin, Z.M.3
Fisher, J.4
-
14
-
-
0032881955
-
Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses
-
Medline. doi:10.1016/S0142-9612(99)00081-2
-
Nevelos JE, Ingham E, Doyle C, Fisher J, Nevelos AB. Analysis of retrieved alumina ceramic components from Mittelmeier total hip prostheses. Biomaterials. 1999;20(19):1833-1840. Medline. doi:10.1016/S0142-9612(99)00081-2
-
(1999)
Biomaterials
, vol.20
, Issue.19
, pp. 1833-1840
-
-
Nevelos, J.E.1
Ingham, E.2
Doyle, C.3
Fisher, J.4
Nevelos, A.B.5
-
15
-
-
0035680629
-
Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions
-
Medline. doi:10.1023/A:1012802308636
-
Stewart T, Tipper J, Streicher R, Ingham E, Fisher J. Long-term wear of HIPed alumina on alumina bearings for THR under microseparation conditions. J Mater Sci Mater Med. 2001;12(10-12):1053-1056. Medline. doi:10.1023/A:1012802308636
-
(2001)
J Mater Sci Mater Med
, vol.12
, Issue.10-12
, pp. 1053-1056
-
-
Stewart, T.1
Tipper, J.2
Streicher, R.3
Ingham, E.4
Fisher, J.5
-
16
-
-
0033814067
-
Microseparation of alumina- alumina hip joints during simulator testing produces clinically relevant wear rates
-
Medline. doi:10.1054/arth.2000.8100
-
Nevelos J, Ingham E, Doyle C, et al. Microseparation of alumina- alumina hip joints during simulator testing produces clinically relevant wear rates. J Arthroplasty. 2000;15(6):793-795. Medline. doi:10.1054/arth.2000.8100
-
(2000)
J Arthroplasty
, vol.15
, Issue.6
, pp. 793-795
-
-
Nevelos, J.1
Ingham, E.2
Doyle, C.3
-
17
-
-
1542348522
-
The influence of implant position on the wear of alumina-onalumina studied in a hip simulator
-
doi:10.1016/S0043-1648(03)00455-1
-
Affatato S, Bersaglia G, Foltran I, Emiliani D, Traina F, Toni A. The influence of implant position on the wear of alumina-onalumina studied in a hip simulator. Wear. 2004;256(3-4):400-405. doi:10.1016/S0043-1648(03)00455-1
-
(2004)
Wear
, vol.256
, Issue.3-4
, pp. 400-405
-
-
Affatato, S.1
Bersaglia, G.2
Foltran, I.3
Emiliani, D.4
Traina, F.5
Toni, A.6
-
18
-
-
33644510166
-
Photoluminescence investigations on alumina ceramic bearing couples tested under different angles of inclination in a Hip joint simulator
-
doi:10.1007/s10853-005-2515-5
-
Taddei P, Affatato S, Fagnano C, Toni A. Photoluminescence investigations on alumina ceramic bearing couples tested under different angles of inclination in a Hip joint simulator. J Mater Sci. 2006;41(2):399-407. doi:10.1007/s10853-005-2515-5
-
(2006)
J Mater Sci
, vol.41
, Issue.2
, pp. 399-407
-
-
Taddei, P.1
Affatato, S.2
Fagnano, C.3
Toni, A.4
-
19
-
-
70049108298
-
Is Ceramic-On-Ceramic Squeaking Phenomenon Reproducible In Vitro? A Long-Term Simulator Study Under Severe Conditions
-
doi:10.1002/jbm.b.31398
-
Affatato S, Traina F, Mazzega-Fabbro C, Sergo V, Viceconti M. Is Ceramic-On-Ceramic Squeaking Phenomenon Reproducible In Vitro? A Long-Term Simulator Study Under Severe Conditions. J Biomed Mater Res B Appl Biomater. 2009;91B(1):264-271. doi:10.1002/jbm.b.31398
-
(2009)
J Biomed Mater Res B Appl Biomater
, vol.91 B
, Issue.1
, pp. 264-271
-
-
Affatato, S.1
Traina, F.2
Mazzega-Fabbro, C.3
Sergo, V.4
Viceconti, M.5
-
20
-
-
74249091359
-
Long-term in-vitro wear performance of an innovative thermo-compressed cross-linked polyethylene
-
doi:10.1016/j.triboint.2009.04.049
-
Affatato S, Zavalloni M, Spinelli M, Costa L, Bracco P, Viceconti M. Long-term in-vitro wear performance of an innovative thermo-compressed cross-linked polyethylene. Tribol Int. 2010;43(102):22-28. doi:10.1016/j.triboint.2009.04.049
-
(2010)
Tribol Int
, vol.43
, Issue.102
, pp. 22-28
-
-
Affatato, S.1
Zavalloni, M.2
Spinelli, M.3
Costa, L.4
Bracco, P.5
Viceconti, M.6
-
21
-
-
0030627862
-
Frictional heating of bearing materials tested in a hip joint wear simulator
-
doi:10.1243/0954411971534728
-
Lu Z, McKellop H. Frictional heating of bearing materials tested in a hip joint wear simulator. Proc Inst Mech Engrs, Part H: J. Eng Med. 1997;211(1):101-107. doi:10.1243/0954411971534728
-
(1997)
Proc Inst Mech Engrs, Part H: J. Eng Med
, vol.211
, Issue.1
, pp. 101-107
-
-
Lu, Z.1
McKellop, H.2
-
22
-
-
0006581415
-
Implants for surgery -Wear of total hip joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for tests
-
ISO-14242/1
-
ISO-14242/1. Implants for surgery -Wear of total hip joint prostheses - Part 1: Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for tests. ISO 14242-1 2002:14.
-
(2002)
, pp. 14
-
-
-
23
-
-
0036274703
-
Analysis of polyethylene particles produced in different wear conditions in vitro
-
Medline. doi:10.1097/00003086- 200206000-00027
-
Calonius O, Saikko V. Analysis of polyethylene particles produced in different wear conditions in vitro. Clin Orthop Relat Res. 2002;399:219-230. Medline. doi:10.1097/00003086- 200206000-00027
-
(2002)
Clin Orthop Relat Res
, vol.399
, pp. 219-230
-
-
Calonius, O.1
Saikko, V.2
-
24
-
-
3042524995
-
-
46th ORS; 2000 Orlando, Florida, USA
-
Wang A, Essner A, Serekian P. Effect of lubricant protein composition of the outcome of hip joint simulator testing. 46th ORS; 2000 Orlando, Florida, USA; 2000 p. 27.
-
(2000)
Effect of Lubricant Protein Composition of the Outcome of Hip Joint Simulator Testing
, pp. 27
-
-
Wang, A.1
Essner, A.2
Serekian, P.3
-
25
-
-
0003151584
-
Further experimental designs
-
In: Armitage P, Berry G, eds., Oxford: Blackwell Scientific Publications
-
Armitage P, Berry G. Further experimental designs. In: Armitage P, Berry G, eds. Statistical methods in medical research. Oxford: Blackwell Scientific Publications: 1994:237-82.
-
(1994)
Statistical Methods In Medical Research
, pp. 237-282
-
-
Armitage, P.1
Berry, G.2
-
26
-
-
0033641059
-
Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements
-
Medline. doi:10.1243/0954411001535381
-
Clarke IC, Good V, Williams P, et al. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng H. 2000;214(4):331-347. Medline. doi:10.1243/0954411001535381
-
(2000)
Proc Inst Mech Eng H
, vol.214
, Issue.4
, pp. 331-347
-
-
Clarke, I.C.1
Good, V.2
Williams, P.3
-
27
-
-
0000174306
-
Investigations of the wear behaviour of ceramic on ceramic combinations in total hip prostheses
-
Oonishi H, Ueno M, Okimatsu H, Amino H. Investigations of the wear behaviour of ceramic on ceramic combinations in total hip prostheses. Bioceramics. 1996;9: 503-506.
-
(1996)
Bioceramics
, vol.9
, pp. 503-506
-
-
Oonishi, H.1
Ueno, M.2
Okimatsu, H.3
Amino, H.4
-
28
-
-
0000242627
-
Ex Vivo and In Vitro Analysis of the Alumina/lumina Bearing System For Hip Joint Prostheses 10th International Symposium of Ceramics In Medicine; 1997
-
Paris, France
-
Refior HJ, Plitz W, Walter A. Ex Vivo and in vitro analysis of the alumina/lumina bearing system for hip joint prostheses 10th International Symposium of Ceramics in Medicine; 1997; Paris, France; 1997: 127-30.
-
(1997)
, pp. 127-130
-
-
Refior, H.J.1
Plitz, W.2
Walter, A.3
-
29
-
-
34548093186
-
Development of a hip wear simulation rig including micro-separation
-
doi:10.1016/j.wear.2007.01.097
-
Ortega-Saenz JA, Hernandez-Rodriguez MA, Perez-Unzueta, Mercado-Solis R. Development of a hip wear simulation rig including micro-separation. Wear. 2007;263(7-12):1527-1532. doi:10.1016/j.wear.2007.01.097
-
(2007)
Wear
, vol.263
, Issue.7-12
, pp. 1527-1532
-
-
Ortega-Saenz, J.A.1
Hernandez-Rodriguez, M.A.2
Perez-Unzueta3
Mercado-Solis, R.4
-
30
-
-
72549109400
-
Friction Measurement in the Biaxial Rocking Motion Hip Joint Simulator
-
doi:10.1115/1.2991121
-
Saikko V. Friction Measurement in the Biaxial Rocking Motion Hip Joint Simulator. J Tribol. 2009;131:23-31. doi:10.1115/1.2991121
-
(2009)
J Tribol
, vol.131
, pp. 23-31
-
-
Saikko, V.1
-
31
-
-
0344198092
-
Long-term results of alumina-on-alumina hip arthroplasty for osteonecrosis
-
Medline
-
Nich C, Sariali e-H, Hannouche D, et al. Long-term results of alumina-on-alumina hip arthroplasty for osteonecrosis. Clin Orthop Relat Res. 2003;417:102-111. Medline.
-
(2003)
Clin Orthop Relat Res
, vol.417
, pp. 102-111
-
-
Nich, C.1
Sariali e-H2
Hannouche, D.3
-
32
-
-
33845389612
-
Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience
-
doi:10.2106/ JBJS.F.00587
-
Toni A, Traina F, Stea S, et al. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Jt Surg (Am). 2006;88:55-63. doi:10.2106/ JBJS.F.00587
-
(2006)
J Bone Jt Surg (Am)
, vol.88
, pp. 55-63
-
-
Toni, A.1
Traina, F.2
Stea, S.3
-
33
-
-
35848961039
-
Wear and acetabular component orientation in third generation alumina-on-alumina ceramic bearings: An analysis of 33 retrievals
-
doi:10.1302/0301-620X.89B9.19282
-
Lusty PJ, Watson A, Tuke MA, Walter WL, Walter WK, Zicat B. Wear and acetabular component orientation in third generation alumina-on-alumina ceramic bearings: an analysis of 33 retrievals. J Bone Jt Surg (Br). 2007;89B(9):1158-1164. doi:10.1302/0301-620X.89B9.19282
-
(2007)
J Bone Jt Surg (Br)
, vol.89 B
, Issue.9
, pp. 1158-1164
-
-
Lusty, P.J.1
Watson, A.2
Tuke, M.A.3
Walter, W.L.4
Walter, W.K.5
Zicat, B.6
-
34
-
-
11844255625
-
Ceramics in total hip replacement
-
Medline. doi:10.1097/01. blo.0000149996.91974.83
-
Hannouche D, Hamadouche M, Nizard R, Bizot P, Meunier A, Sedel L. Ceramics in total hip replacement. Clin Orthop Relat Res. 2005;430:62-71. Medline. doi:10.1097/01. blo.0000149996.91974.83
-
(2005)
Clin Orthop Relat Res
, vol.430
, pp. 62-71
-
-
Hannouche, D.1
Hamadouche, M.2
Nizard, R.3
Bizot, P.4
Meunier, A.5
Sedel, L.6
-
35
-
-
0037241660
-
Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation
-
Part H. doi:10.1243/09544110360579367
-
Williams S, Butter S, Stewart T, Ingham E, Stone M, Fisher J. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation. Proc- Inst Mech Eng. 2003;217(2):147-153. Part H. doi:10.1243/09544110360579367
-
(2003)
Proc- Inst Mech Eng
, vol.217
, Issue.2
, pp. 147-153
-
-
Williams, S.1
Butter, S.2
Stewart, T.3
Ingham, E.4
Stone, M.5
Fisher, J.6
|