-
1
-
-
3042668265
-
Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT
-
DOI 10.1167/iovs.03-0514
-
L.A. Paunescu, J.S. Schuman, and L.L. Price Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT Invest Ophthalmol Vis Sci 45 2004 1716 1724 (Pubitemid 38868963)
-
(2004)
Investigative Ophthalmology and Visual Science
, vol.45
, Issue.6
, pp. 1716-1724
-
-
Paunescu, L.A.1
Schuman, J.S.2
Price, L.L.3
Stark, P.C.4
Beaton, S.5
Ishikawa, H.6
Wollstein, G.7
Fujimoto, J.G.8
-
2
-
-
23244456347
-
Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
-
DOI 10.1167/iovs.04-1174
-
D.L. Budenz, R.T. Chang, and X. Huang Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes Invest Ophthalmol Vis Sci 46 2005 2440 2443 (Pubitemid 43119491)
-
(2005)
Investigative Ophthalmology and Visual Science
, vol.46
, Issue.7
, pp. 2440-2443
-
-
Budenz, D.L.1
Chang, R.T.2
Huang, X.3
Knighton, R.W.4
Tielsch, J.M.5
-
3
-
-
63049117929
-
Spectral domain optical coherence tomography for glaucoma (an AOS thesis)
-
J.S. Schuman Spectral domain optical coherence tomography for glaucoma (an AOS thesis) Trans Am Ophthalmol Soc 106 2008 426 458
-
(2008)
Trans Am Ophthalmol Soc
, vol.106
, pp. 426-458
-
-
Schuman, J.S.1
-
4
-
-
41149149872
-
Reproducibility of peripapillary retinal nerve fiber thickness measurements with the Stratus OCT in glaucomatous eyes
-
D.L. Budenz, M.J. Fredette, W.J. Feuer, and D.R. Anderson Reproducibility of peripapillary retinal nerve fiber thickness measurements with the Stratus OCT in glaucomatous eyes Ophthalmology 115 2008 661 666
-
(2008)
Ophthalmology
, vol.115
, pp. 661-666
-
-
Budenz, D.L.1
Fredette, M.J.2
Feuer, W.J.3
Anderson, D.R.4
-
5
-
-
67649311848
-
Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography
-
O.J. Knight, R.T. Chang, W.J. Feuer, and D.L. Budenz Comparison of retinal nerve fiber layer measurements using time domain and spectral domain optical coherent tomography Ophthalmology 116 2009 1271 1277
-
(2009)
Ophthalmology
, vol.116
, pp. 1271-1277
-
-
Knight, O.J.1
Chang, R.T.2
Feuer, W.J.3
Budenz, D.L.4
-
6
-
-
79551570246
-
Ability of Cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes
-
Cirrus OCT Normative Database Study Group
-
J.C. Mwanza, J.D. Oakley, D.R. Anderson, D.L. Budenz Cirrus OCT Normative Database Study Group Ability of Cirrus HD-OCT optic nerve head parameters to discriminate normal from glaucomatous eyes Ophthalmology 118 2011 241 248
-
(2011)
Ophthalmology
, vol.118
, pp. 241-248
-
-
Mwanza, J.C.1
Oakley, J.D.2
Anderson, D.R.3
Budenz, D.L.4
-
7
-
-
0032890793
-
The ocular hypertension treatment study. Design and baseline description of the participants
-
M.O. Gordon, M.A. Kass Ocular Hypertension Treatment Study (OHTS) Group The Ocular Hypertension Treatment Study: design and baseline description of the participants Arch Ophthalmol 117 1999 573 583 (Pubitemid 29218422)
-
(1999)
Archives of Ophthalmology
, vol.117
, Issue.5
, pp. 573-583
-
-
Gordon, M.O.1
Kass, M.A.2
-
8
-
-
58249084154
-
Detection of optic nerve head neural canal opening within histomorphometric and spectral domain optical coherence tomography data sets
-
N.G. Strouthidis, H. Yang, and B. Fortune Detection of optic nerve head neural canal opening within histomorphometric and spectral domain optical coherence tomography data sets Invest Ophthalmol Vis Sci 50 2009 214 223
-
(2009)
Invest Ophthalmol Vis Sci
, vol.50
, pp. 214-223
-
-
Strouthidis, N.G.1
Yang, H.2
Fortune, B.3
-
10
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
PII S0140673686908378
-
J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310 (Pubitemid 16134762)
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
12
-
-
0009853517
-
Comparison of intraclass correlation coefficients with the ratio of two independent f-statistics
-
C.O. Zerbe, and D.E. Goldgar Comparison of intraclass correlation coefficients with the ratio of two independent f-statistics Commun Stats Theory Methods 9 1980 1641 1655
-
(1980)
Commun Stats Theory Methods
, vol.9
, pp. 1641-1655
-
-
Zerbe, C.O.1
Goldgar, D.E.2
-
16
-
-
0023710404
-
Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes
-
J.B. Jonas, G.C. Gusek, and G.O. Naumann Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes Invest Ophthalmol Vis Sci 29 1988 1151 1158
-
(1988)
Invest Ophthalmol Vis Sci
, vol.29
, pp. 1151-1158
-
-
Jonas, J.B.1
Gusek, G.C.2
Naumann, G.O.3
-
17
-
-
34248180570
-
Measurement variability in Heidelberg retina tomograph imaging of neuroretinal rim area
-
DOI 10.1167/iovs.06-0096
-
V.M. Owen, N.G. Strouthidis, D.F. Garway-Heath, and D.P. Crabb Measurement variability in Heidelberg retina tomograph imaging of neuroretinal rim area Invest Ophthalmol Vis Sci 47 2006 5322 5330 (Pubitemid 46723782)
-
(2006)
Investigative Ophthalmology and Visual Science
, vol.47
, Issue.12
, pp. 5322-5330
-
-
Owen, V.M.F.1
Strouthidis, N.G.2
Garway-Heath, D.F.3
Crabb, D.P.4
-
18
-
-
0023869921
-
Intraobserver and interobserver agreement in measurement of optic disc characteristics
-
J. Tielsch, J. Katz, and H.A. Quigley Intraobserver and interobserver agreement in measurement of optic disc characteristics Ophthalmology 95 1988 350 356 (Pubitemid 18075767)
-
(1988)
Ophthalmology
, vol.95
, Issue.3
, pp. 350-356
-
-
Tielsch, J.M.1
Katz, J.2
Quigley, H.A.3
Miller, N.R.4
Sommer, A.5
-
19
-
-
0026541132
-
Expert agreement in evaluating the optic disc for glaucoma
-
R. Varma, W.C. Steinmann, and I.U. Scott Expert agreement in evaluating the optic disc for glaucoma Ophthalmology 99 1992 215 221
-
(1992)
Ophthalmology
, vol.99
, pp. 215-221
-
-
Varma, R.1
Steinmann, W.C.2
Scott, I.U.3
-
20
-
-
0035523153
-
Interobserver variability in the estimation of the cup/disk ratio among observers of differing educational background
-
B.A. Teitelbaum, R. Haefs, and D. Connor Interobserver variability in the estimation of the cup/disk ratio among observers of differing educational background Optometry 72 2001 729 732 (Pubitemid 33595864)
-
(2001)
Optometry
, vol.72
, Issue.11
, pp. 729-732
-
-
Teitelbaum, B.A.1
Haefs, R.2
Connor, D.3
-
21
-
-
0028907810
-
Agreement between clinicians and a confocal scanning laser ophthalmoscope in estimating cup/disk ratios
-
L. Zangwill, S. Shakiba, J. Caprioli, and R.N. Weinreb Agreement between clinicians and a confocal scanning laser ophthalmoscope in estimating cup/disk ratios Am J Ophthalmol 199 1995 415 421
-
(1995)
Am J Ophthalmol
, vol.199
, pp. 415-421
-
-
Zangwill, L.1
Shakiba, S.2
Caprioli, J.3
Weinreb, R.N.4
-
22
-
-
0036149042
-
The Ocular Hypertension Treatment Study: Reproducibility of cup/disk ratio measurements over time at an Optic Disc Reading Center
-
DOI 10.1016/S0002-9394(01)01338-1, PII S0002939401013381
-
W.J. Feuer, R.K. Parrish II, J.C. Schiffman Ocular Hypertension Treatment Study Group The Ocular Hypertension Treatment Study: reproducibility of cup/disk ratio measurements over time at an optic disc reading center Am J Ophthalmol 133 2002 19 28 (Pubitemid 34076500)
-
(2002)
American Journal of Ophthalmology
, vol.133
, Issue.1
, pp. 19-28
-
-
Feuer, W.J.1
Parrish II, R.K.2
Schiffman, J.C.3
Anderson, D.R.4
Budenz, D.L.5
Wells, M.-C.6
Hess, D.J.7
Kass, M.A.8
Gordon, M.O.9
-
23
-
-
67651146471
-
Variance owing to observer, repeat imaging, and fundus camera type on cup-to-disc ratio estimates by stereo planimetry
-
Y.H. Kwon, M. Adix, and M.B. Zimmerman Variance owing to observer, repeat imaging, and fundus camera type on cup-to-disc ratio estimates by stereo planimetry J Glaucoma 18 2009 305 310
-
(2009)
J Glaucoma
, vol.18
, pp. 305-310
-
-
Kwon, Y.H.1
Adix, M.2
Zimmerman, M.B.3
-
24
-
-
77949875422
-
Clinical assessment of stereoscopic optic disc photographs for glaucoma: The European Optic Disc Assessment Trial
-
N.J. Reus, H.G. Lemij, and D.F. Garway-Heath Clinical assessment of stereoscopic optic disc photographs for glaucoma: the European Optic Disc Assessment Trial Ophthalmology 117 2010 717 723
-
(2010)
Ophthalmology
, vol.117
, pp. 717-723
-
-
Reus, N.J.1
Lemij, H.G.2
Garway-Heath, D.F.3
-
25
-
-
0024599154
-
Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios
-
R. Varma, G.L. Spaeth, W.C. Steinmann, and L.J. Katz Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios Arch Ophthalmol 107 1989 526 529 (Pubitemid 19101010)
-
(1989)
Archives of Ophthalmology
, vol.107
, Issue.4
, pp. 526-529
-
-
Varma, R.1
Spaeth, G.L.2
Steinmann, W.C.3
Katz, L.J.4
-
26
-
-
59749093254
-
Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement
-
G. Savini, E.M. Espana, and A.C. Acosta Agreement between optical coherence tomography and digital stereophotography in vertical cup-to-disc ratio measurement Graefes Arch Clin Exp Ophthalmol 247 2009 377 383
-
(2009)
Graefes Arch Clin Exp Ophthalmol
, vol.247
, pp. 377-383
-
-
Savini, G.1
Espana, E.M.2
Acosta, A.C.3
-
27
-
-
73349108428
-
Measurement of optic nerve head parameters: Comparison of optical coherence tomography with digital planimetry
-
C. Samarawickrama, A. Pai, and S.C. Huynh Measurement of optic nerve head parameters: comparison of optical coherence tomography with digital planimetry J Glaucoma 18 2009 571 575
-
(2009)
J Glaucoma
, vol.18
, pp. 571-575
-
-
Samarawickrama, C.1
Pai, A.2
Huynh, S.C.3
-
28
-
-
0037375946
-
Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy
-
DOI 10.1016/S0002-9394(02)02093-7
-
J.S. Schuman, G. Wollstein, and T. Farra Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy Am J Ophthalmol 135 2003 504 512 (Pubitemid 36315962)
-
(2003)
American Journal of Ophthalmology
, vol.135
, Issue.4
, pp. 504-512
-
-
Schuman, J.S.1
Wollstein, G.2
Farra, T.3
Hertzmark, E.4
Aydin, A.5
Fujimoto, J.G.6
Paunescu, L.A.7
-
29
-
-
2942618989
-
Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma
-
DOI 10.1001/archopht.122.6.827
-
F.A. Medeiros, L.M. Zangwill, C. Bowd, and R.N. Weinreb Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and Stratus OCT optical coherence tomograph for the detection of glaucoma Arch Ophthalmol 122 2004 827 837 (Pubitemid 38736241)
-
(2004)
Archives of Ophthalmology
, vol.122
, Issue.6
, pp. 827-837
-
-
Medeiros, F.A.1
Zangwill, L.M.2
Bowd, C.3
Weinreb, R.N.4
-
30
-
-
34248355562
-
Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features
-
DOI 10.1167/iovs.06-1081
-
M.D. Abrmoff, W.L. Alward, and E.C. Greenlee Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features Invest Ophthalmol Vis Sci 48 2007 1665 1673 (Pubitemid 351261352)
-
(2007)
Investigative Ophthalmology and Visual Science
, vol.48
, Issue.4
, pp. 1665-1673
-
-
Abramoff, M.D.1
Alward, W.L.M.2
Greenlee, E.C.3
Shuba, L.4
Kim, C.Y.5
Fingert, J.H.6
Kwon, Y.H.7
-
31
-
-
77953604166
-
Diagnostic ability of a linear discriminant function for optic nerve head parameters measured with optical coherence tomography for perimetric glaucoma
-
L.E. Pablo, A. Ferreras, A.B. Pajarín, and P. Fogagnolo Diagnostic ability of a linear discriminant function for optic nerve head parameters measured with optical coherence tomography for perimetric glaucoma Eye (Lond) 24 2010 1051 1057
-
(2010)
Eye (Lond)
, vol.24
, pp. 1051-1057
-
-
Pablo, L.E.1
Ferreras, A.2
Pajarín, A.B.3
Fogagnolo, P.4
-
32
-
-
73349120958
-
Automated segmentation of the cup and rim from spectral domain OCT of the optic nerve head
-
M.D. Abrmoff, Y. Lee, and M. Niemeijer Automated segmentation of the cup and rim from spectral domain OCT of the optic nerve head Invest Ophthalmol Vis Sci 50 2009 5778 5784
-
(2009)
Invest Ophthalmol Vis Sci
, vol.50
, pp. 5778-5784
-
-
Abrmoff, M.D.1
Lee, Y.2
Niemeijer, M.3
|