메뉴 건너뛰기




Volumn 10, Issue 3, 2011, Pages 339-355

Mechanistic insight into the physiological relevance of helical blood flow in the human aorta: An in vivo study

Author keywords

4D phase contrast MRI; Aortic arch; Fluid mechanics; Hemodynamics; Perfusion; Spiral flow

Indexed keywords

AORTIC ARCH; AORTIC FLOW; BLOOD FLOW; BLOOD FLOW DYNAMICS; FLUID TRANSPORT; GAIN INSIGHT; GROUP ANALYSIS; HEALTHY HUMANS; HELICAL CONTENT; HELICAL FLOWS; HELICITIES; IN-VIVO; PERFUSION; PHASE CONTRAST MAGNETIC RESONANCE IMAGING; PHASE CONTRAST MRI; QUANTITATIVE DATA; ROTATING FLOW; SPIRAL FLOW; STATISTICALLY SIGNIFICANT DIFFERENCE; THORACIC AORTA;

EID: 79957890662     PISSN: 16177959     EISSN: 16822978     Source Type: Journal    
DOI: 10.1007/s10237-010-0238-2     Document Type: Article
Times cited : (206)

References (59)
  • 2
    • 59449095811 scopus 로고
    • Torsional ventricular motion and rotary blood flow. What is the clinical significance
    • FA Baciewicz DG Penney WA Marinelli R Marinelli 1991 Torsional ventricular motion and rotary blood flow. What is the clinical significance Card Chron 5 1 8
    • (1991) Card Chron , vol.5 , pp. 1-8
    • Baciewicz, F.A.1    Penney, D.G.2    Marinelli, W.A.3    Marinelli, R.4
  • 3
    • 0014482889 scopus 로고
    • The fluid mechanics of the aortic valve
    • 10.1017/S0022112069001406
    • BJ Bellhouse L Talbot 1969 The fluid mechanics of the aortic valve J Fluid Mech 35 721 736 10.1017/S0022112069001406
    • (1969) J Fluid Mech , vol.35 , pp. 721-736
    • Bellhouse, B.J.1    Talbot, L.2
  • 4
    • 0242280305 scopus 로고
    • Efficient tests for normality, homoscedasticity and serial independence of regression residuals: Monte Carlo evidence
    • 10.1016/0165-1765(81)90035-5
    • AK Bera CM Jarque 1981 Efficient tests for normality, homoscedasticity and serial independence of regression residuals: Monte Carlo evidence Econ Lett 7 4 313 318 10.1016/0165-1765(81)90035-5
    • (1981) Econ Lett , vol.7 , Issue.4 , pp. 313-318
    • Bera, A.K.1    Jarque, C.M.2
  • 5
    • 0032751769 scopus 로고    scopus 로고
    • 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects
    • DOI 10.1002/(SICI)1522-2586(199911)10:5<861::AID-JMRI35>3.0.CO;2-E
    • HG Bogren MH Buonocore 1999 4D magnetic resonance velocity mapping of blood flow patterns in the aorta in young vs. elderly normal subjects J Magn Reson Imaging 10 861 869 10.1002/(SICI)1522-2586(199911)10:5<861::AID- JMRI35>3.0.CO;2-E (Pubitemid 29519793)
    • (1999) Journal of Magnetic Resonance Imaging , vol.10 , Issue.5 , pp. 861-869
    • Bogren, H.G.1    Buonocore, M.H.2
  • 9
    • 0037331617 scopus 로고    scopus 로고
    • The joint cascade of energy and helicity in three-dimensional turbulence
    • DOI 10.1063/1.1533070
    • Q Chen S Chen GL Eyink 2003 The joint cascade of energy and helicity in three-dimensional turbulence Phys Fluids 15 361 374 1959521 10.1063/1.1533070 (Pubitemid 36281006)
    • (2003) Physics of Fluids , vol.15 , Issue.2 , pp. 361-374
    • Chen, Q.1    Chen, S.2    Eyink, G.L.3
  • 10
    • 73949140850 scopus 로고    scopus 로고
    • Swirling flow can suppress flow disturbances in endovascular stents: A numerical study
    • 10.1097/MAT.0b013e3181b78e46
    • ZS Chen YB Fan XY Deng Z Xu 2009 Swirling flow can suppress flow disturbances in endovascular stents: a numerical study ASAIO J 55 6 543 549 10.1097/MAT.0b013e3181b78e46
    • (2009) ASAIO J , vol.55 , Issue.6 , pp. 543-549
    • Chen, Z.S.1    Fan, Y.B.2    Deng, X.Y.3    Xu, Z.4
  • 11
    • 0029686346 scopus 로고    scopus 로고
    • An analysis of 3D particle path integration algorithms
    • DOI 10.1006/jcph.1996.0015
    • DL Darmofal R Haimes 1996 An analysis of 3D particle path integration algorithms J Comput Phys 123 182 195 0840.65081 10.1006/jcph.1996.0015 (Pubitemid 126161384)
    • (1996) Journal of Computational Physics , vol.123 , Issue.1 , pp. 182-195
    • Darmofal, D.L.1    Haimes, R.2
  • 13
    • 48149105466 scopus 로고    scopus 로고
    • An S-type bypass can improve the hemodynamics in the bypassed arteries and suppress intimal hyperplasia along the host artery floor
    • 10.1016/j.jbiomech.2008.05.008
    • Y Fan Z Xu W Jiang X Deng K Wang A Sun 2008 An S-type bypass can improve the hemodynamics in the bypassed arteries and suppress intimal hyperplasia along the host artery floor J Biomech 41 2498 2505 10.1016/j.jbiomech.2008.05.008
    • (2008) J Biomech , vol.41 , pp. 2498-2505
    • Fan, Y.1    Xu, Z.2    Jiang, W.3    Deng, X.4    Wang, K.5    Sun, A.6
  • 14
    • 0035156783 scopus 로고    scopus 로고
    • Navigator echoes in cardiac magnetic resonance
    • DOI 10.1081/JCMR-100107467
    • D Firmin J Keegan 2001 Navigator echoes in cardiac magnetic resonance J Cardiovasc Magn Reson 3 183 193 10.1081/JCMR-100107467 (Pubitemid 33062624)
    • (2001) Journal of Cardiovascular Magnetic Resonance , vol.3 , Issue.3 , pp. 183-193
    • Firmin, D.1    Keegan, J.2
  • 16
    • 33846597931 scopus 로고    scopus 로고
    • Time-resolved, 3-dimensional magnetic resonance flow analysis at 3 T: Visualization of normal and pathological aortic vascular hemodynamics
    • DOI 10.1097/01.rct.0000232918.45158.c9, PII 0000472820070100000003
    • A Frydrychowicz A Harloff B Jung M Zaitsev E Weigang TA Bley M Langer J Hennig M Markl 2007 Time-resolved, 3-dimensional magnetic resonance flow analysis at 3 T: visualization of normal and pathological aortic vascular haemodynamics J Comput Assist Tomogr 31 9 15 10.1097/01.rct.0000232918.45158.c9 (Pubitemid 46183336)
    • (2007) Journal of Computer Assisted Tomography , vol.31 , Issue.1 , pp. 9-15
    • Frydrychowicz, A.1    Harloff, A.2    Jung, B.3    Zaitsev, M.4    Weigang, E.5    Bley, T.A.6    Langer, M.7    Hennig, J.8    Markl, M.9
  • 17
    • 47049128751 scopus 로고    scopus 로고
    • Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation
    • 10.1186/1532-429X-10-30
    • A Frydrychowicz R Arnold D Hirtler C Schlensak AF Stalder J Hennig M Langer M Markl 2008 Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation J Cardiovasc Magn Reson 10 1 30 10.1186/1532-429X-10-30
    • (2008) J Cardiovasc Magn Reson , vol.10 , Issue.1 , pp. 30
    • Frydrychowicz, A.1    Arnold, R.2    Hirtler, D.3    Schlensak, C.4    Stalder, A.F.5    Hennig, J.6    Langer, M.7    Markl, M.8
  • 18
    • 47649131679 scopus 로고    scopus 로고
    • Images in cardiovascular medicine. in vivo dimensional flow connectivity mapping after extracardiac total cavopulmonary connection
    • 10.1161/CIRCULATIONAHA.107.761304
    • A Frydrychowicz R Arnold A Harloff C Schlensak J Hennig M Langer M Markl 2008 Images in cardiovascular medicine. In vivo dimensional flow connectivity mapping after extracardiac total cavopulmonary connection Circulation 118 e16 e17 10.1161/CIRCULATIONAHA.107.761304
    • (2008) Circulation , vol.118
    • Frydrychowicz, A.1    Arnold, R.2    Harloff, A.3    Schlensak, C.4    Hennig, J.5    Langer, M.6    Markl, M.7
  • 20
    • 19744373973 scopus 로고    scopus 로고
    • A mathematical description of blood spiral flow in vessels: Application to a numerical study of flow in arterial bending
    • DOI 10.1016/j.jbiomech.2004.06.028, PII S0021929004003380
    • M Grigioni C Daniele U Morbiducci C Del Gaudio G D'Avenio A Balducci V Barbaro 2005 A mathematical description of blood spiral flow in vessels: application to a numerical study of flow in arterial bending J Biomech 38 1375 1386 10.1016/j.jbiomech.2004.06.028 (Pubitemid 40744894)
    • (2005) Journal of Biomechanics , vol.38 , Issue.7 , pp. 1375-1386
    • Grigioni, M.1    Daniele, C.2    Morbiducci, U.3    Del Gaudio, C.4    D'Avenio, G.5    Balducci, A.6    Barbaro, V.7
  • 21
    • 37349004799 scopus 로고    scopus 로고
    • Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping
    • DOI 10.1002/jmri.21082
    • TA Hope M Markl L Wigström MT Alley DC Miller RJ Herfkens 2007 Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping J Magn Reson Imaging 26 1471 1479 10.1002/jmri.21082 (Pubitemid 350291274)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.6 , pp. 1471-1479
    • Hope, T.A.1    Markl, M.2    Wigstrom, L.3    Alley, M.T.4    Miller, D.C.5    Herfkens, R.J.6
  • 22
    • 0042706303 scopus 로고    scopus 로고
    • Two-dimensional flow quantitative MRI of aortic arch blood flow patterns: Effect of age, sex, and presence of carotid atheromatous disease on prevalence of spiral blood flow
    • DOI 10.1002/jmri.10341
    • JG Houston SJ Gandy DG Sheppard JB Dick JJ Belch PA Stonebridge 2003 Two-dimensional flow quantitative MRI of aortic arch blood flow patterns: Effect of age, sex, and presence of carotid atheromatous disease on prevalence of spiral blood flow J Magn Reson Imaging 18 169 174 10.1002/jmri.10341 (Pubitemid 36935947)
    • (2003) Journal of Magnetic Resonance Imaging , vol.18 , Issue.2 , pp. 169-174
    • Houston, J.G.1    Gandy, S.J.2    Sheppard, D.G.3    Dick, J.B.4    Belch, J.J.F.5    Stonebridge, P.A.6
  • 23
    • 0027484408 scopus 로고
    • Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping
    • PJ Kilner GZ Yang RH Mohiaddin DN Firmin DB Longmore 1993 Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping Circulation 88 2235 2247 (Pubitemid 23326104)
    • (1993) Circulation , vol.88 , Issue.5 I , pp. 2235-2247
    • Kilner, P.J.1    Yang, G.Z.2    Mohiaddin, R.H.3    Firmin, D.N.4    Longmore, D.B.5
  • 25
    • 0003437353 scopus 로고
    • 2nd English edn. Chelsea Publishing Company, New York (translation edited by Nathan Morrison)
    • Kolmogorov AN (1956) Foundations of the theory of probability, 2nd English edn. Chelsea Publishing Company, New York (translation edited by Nathan Morrison)
    • (1956) Foundations of the Theory of Probability
    • Kolmogorov, A.N.1
  • 26
    • 0020623530 scopus 로고
    • Pulsatile flow in a model carotid bifurcation
    • DN Ku DP Giddens 1983 Pulsatile flow in a model carotid bifurcation Arteriosclerosis 3 31 39 (Pubitemid 13083089)
    • (1983) Arteriosclerosis , vol.3 , Issue.1 , pp. 31-39
    • Ku, D.N.1    Giddens, D.P.2
  • 27
    • 67650079882 scopus 로고    scopus 로고
    • A numerical study on the flow of blood and the transport of LDL in the human aorta: The physiological significance of the helical flow in the aortic arch
    • 10.1152/ajpheart.00266.2009
    • X Liu F Pu Y Fan X Deng D Li S Li 2009 A numerical study on the flow of blood and the transport of LDL in the human aorta: the physiological significance of the helical flow in the aortic arch Am J Physiol Heart Circ Physiol 297 H163 H170 10.1152/ajpheart.00266.2009
    • (2009) Am J Physiol Heart Circ Physiol , vol.297
    • Liu, X.1    Pu, F.2    Fan, Y.3    Deng, X.4    Li, D.5    Li, S.6
  • 28
    • 0033485806 scopus 로고    scopus 로고
    • Hemodynamic shear stress and its role in atherosclerosis
    • 10.1001/jama.282.21.2035
    • AM Malek SL Alper S Izumo 1999 Hemodynamic shear stress and its role in atherosclerosis JAMA 282 2035 2042 10.1001/jama.282.21.2035
    • (1999) JAMA , vol.282 , pp. 2035-2042
    • Malek, A.M.1    Alper, S.L.2    Izumo, S.3
  • 29
    • 3343019140 scopus 로고    scopus 로고
    • Time-resolved 3-dimensional velocity mapping in the thoracic aorta: Visualization of 3-directional blood flow patterns in healthy volunteers and patients
    • DOI 10.1097/00004728-200407000-00005
    • M Markl MT Draney MD Hope JM Levin FP Chan MT Alley NJ Pelc RJ Herfkens 2004 Time-resolved 3-dimensional velocity mapping in the thoracic aorta: visualization of 3-directional blood flow patterns in healthy volunteers and patients J Comput Assist Tomogr 28 459 468 10.1097/00004728-200407000-00005 (Pubitemid 38988812)
    • (2004) Journal of Computer Assisted Tomography , vol.28 , Issue.4 , pp. 459-468
    • Markl, M.1    Draney, M.T.2    Hope, M.D.3    Levin, J.M.4    Chan, F.P.5    Alley, M.T.6    Pelc, N.J.7    Herfkens, R.J.8
  • 30
    • 34548382711 scopus 로고    scopus 로고
    • Sclerotic aortic valve: Flow-sensitive 4-dimensional magnetic resonance imaging reveals 3 distinct flow-pattern changes
    • DOI 10.1161/CIRCULATIONAHA.107.704460, PII 0000301720070904000018
    • M Markl A Harloff D Föll M Langer J Hennig A Frydrychowicz 2007 Sclerotic aortic valve: flow-sensitive 4-dimensional magnetic resonance imaging reveals 3 distinct flow-pattern changes Circulation 116 e336 e337 10.1161/CIRCULATIONAHA.107.704460 (Pubitemid 47360223)
    • (2007) Circulation , vol.116 , Issue.10
    • Markl, M.1    Harloff, A.2    Foll, D.3    Langer, M.4    Hennig, J.5    Frydrychowicz, A.6
  • 31
    • 40249118214 scopus 로고    scopus 로고
    • A computational framework for derivative-free optimization of cardiovascular geometries
    • 2417164 1194.76296 10.1016/j.cma.2007.12.009
    • AL Marsden JA Feinstein CA Taylor 2008 A computational framework for derivative-free optimization of cardiovascular geometries Comput Methods Appl Mech Eng 197 1890 1905 2417164 1194.76296 10.1016/j.cma.2007.12.009
    • (2008) Comput Methods Appl Mech Eng , vol.197 , pp. 1890-1905
    • Marsden, A.L.1    Feinstein, J.A.2    Taylor, C.A.3
  • 33
    • 0014441553 scopus 로고
    • The degree of knottedness of tangled vortex lines
    • 10.1017/S0022112069001479
    • HK Moffatt 1969 The degree of knottedness of tangled vortex lines J Fluid Mech 36 17 29 10.1017/S0022112069001479
    • (1969) J Fluid Mech , vol.36 , pp. 17-29
    • Moffatt, H.K.1
  • 34
    • 0001464426 scopus 로고
    • The energy spectrum of knots and links
    • HK Moffatt 1990 The energy spectrum of knots and links Nature 347 367 369 10.1038/347367a0 (Pubitemid 120028957)
    • (1990) Nature , vol.347 , Issue.6291 , pp. 367-369
    • Moffatt, H.K.1
  • 35
    • 0026804003 scopus 로고
    • Helicity in laminar and turbulent flow
    • 1145012 10.1146/annurev.fl.24.010192.001433
    • HK Moffatt A Tsinober 1992 Helicity in laminar and turbulent flow Ann Rev Fluid Mech 24 281 312 1145012 10.1146/annurev.fl.24.010192.001433
    • (1992) Ann Rev Fluid Mech , vol.24 , pp. 281-312
    • Moffatt, H.K.1    Tsinober, A.2
  • 36
    • 33846397823 scopus 로고    scopus 로고
    • Helical flow as fluid dynamic signature for atherogenesis risk in aortocoronary bypass. A numeric study
    • DOI 10.1016/j.jbiomech.2006.02.017, PII S0021929006000741
    • U Morbiducci R Ponzini M Grigioni A Redaelli 2007 Helical flow as fluid dynamic signature for atherogenesis in aortocoronary bypass. A numeric study J Biomech 40 519 534 10.1016/j.jbiomech.2006.02.017 (Pubitemid 46127487)
    • (2007) Journal of Biomechanics , vol.40 , Issue.3 , pp. 519-534
    • Morbiducci, U.1    Ponzini, R.2    Grigioni, M.3    Redaelli, A.4
  • 37
    • 34648833622 scopus 로고    scopus 로고
    • Does flow dynamics of the magnetic vascular coupling for distal anastomosis in coronary artery bypass grafting contribute to the risk of graft failure
    • U Morbiducci M Lemma R Ponzini A Boi L Bondavalli C Antona FM Montevecchi A Redaelli 2007 Does flow dynamics of the magnetic vascular coupling for distal anastomosis in coronary artery bypass grafting contribute to the risk of graft failure Int J Artif Organs 30 628 639
    • (2007) Int J Artif Organs , vol.30 , pp. 628-639
    • Morbiducci, U.1    Lemma, M.2    Ponzini, R.3    Boi, A.4    Bondavalli, L.5    Antona, C.6    Montevecchi, F.M.7    Redaelli, A.8
  • 39
    • 68149161782 scopus 로고    scopus 로고
    • Blood damage safety of prosthetic heart valves. Shear induced platelet activation and local flow dynamics: A fluid-structure interaction approach
    • 10.1016/j.jbiomech.2009.05.014
    • U Morbiducci R Ponzini M Nobili D Massai FM Montevecchi D Bluestein A Redaelli 2009 Blood damage safety of prosthetic heart valves. Shear induced platelet activation and local flow dynamics: a fluid-structure interaction approach J Biomech 42 12 1952 1960 10.1016/j.jbiomech.2009.05.014
    • (2009) J Biomech , vol.42 , Issue.12 , pp. 1952-1960
    • Morbiducci, U.1    Ponzini, R.2    Nobili, M.3    Massai, D.4    Montevecchi, F.M.5    Bluestein, D.6    Redaelli, A.7
  • 40
    • 78651384071 scopus 로고    scopus 로고
    • Quantitative analysis of bulk flow in image-based haemodynamic models of the carotid bifurcation: The influence of outflow conditions as test case
    • doi: 10.1007/s10439-010-0099-y
    • Morbiducci U, Gallo D, Ponzini R, Massai D, Antiga L, Redaelli A, Montevecchi FM (2010) Quantitative analysis of bulk flow in image-based haemodynamic models of the carotid bifurcation: the influence of outflow conditions as test case. Ann Biomed Eng. doi: 10.1007/s10439-010-0099-y
    • (2010) Ann Biomed Eng.
    • Morbiducci, U.1    Gallo, D.2    Ponzini, R.3    Massai, D.4    Antiga, L.5    Redaelli, A.6    Montevecchi, F.M.7
  • 43
    • 85047680612 scopus 로고
    • Velocity patterns in the aorta
    • 10.1093/cvr/5.3.319
    • WA Seed NB Wood 1971 Velocity patterns in the aorta Cardiovasc Res 5 319 330 10.1093/cvr/5.3.319
    • (1971) Cardiovasc Res , vol.5 , pp. 319-330
    • Seed, W.A.1    Wood, N.B.2
  • 44
    • 0023234639 scopus 로고
    • Blood velocity distribution in the human ascending aorta
    • L Segadal K Matre 1987 Blood velocity distribution in the human ascending aorta Circulation 76 90 100 (Pubitemid 17093196)
    • (1987) Circulation , vol.76 , Issue.1 , pp. 90-100
    • Segadal, L.1    Matre, K.2
  • 45
    • 44649107730 scopus 로고    scopus 로고
    • Characterization of coherent structures in the cardiovascular system
    • 10.1007/s10439-008-9502-3
    • SC Shadden CA Taylor 2008 Characterization of coherent structures in the cardiovascular system Ann Biomed Eng 36 7 1152 1162 10.1007/s10439-008-9502-3
    • (2008) Ann Biomed Eng , vol.36 , Issue.7 , pp. 1152-1162
    • Shadden, S.C.1    Taylor, C.A.2
  • 46
    • 77953578906 scopus 로고    scopus 로고
    • Computational analysis of an aortic valve jet with Lagrangian coherent structures
    • 2730424 10.1063/1.3272780
    • SC Shadden A Astorino JF Gerbeau 2010 Computational analysis of an aortic valve jet with Lagrangian coherent structures Chaos 20 017512 2730424 10.1063/1.3272780
    • (2010) Chaos , vol.20 , pp. 017512
    • Shadden, S.C.1    Astorino, A.2    Gerbeau, J.F.3
  • 48
    • 0033998791 scopus 로고    scopus 로고
    • Simulated pathline visualization of computed periodic blood flow patterns
    • DOI 10.1016/S0021-9290(99)00205-5, PII S0021929099002055
    • DA Steinman 2000 Simulated pathline visualization of computed periodic blood flow patterns J Biomech 33 623 628 10.1016/S0021-9290(99)00205-5 (Pubitemid 30116701)
    • (2000) Journal of Biomechanics , vol.33 , Issue.5 , pp. 623-628
    • Steinman, D.A.1
  • 49
    • 0025746562 scopus 로고
    • Spiral laminar flow in arteries
    • 10.1016/0140-6736(91)92238-W
    • PA Stonebridge CM Brophy 1991 Spiral laminar flow in arteries Lancet 338 1360 1361 10.1016/0140-6736(91)92238-W
    • (1991) Lancet , vol.338 , pp. 1360-1361
    • Stonebridge, P.A.1    Brophy, C.M.2
  • 51
    • 68649107562 scopus 로고    scopus 로고
    • Numerical investigation of blood flow in the distal end of an axis-deviated arterial bypass model
    • A Sun Y Fan X Deng 2009 Numerical investigation of blood flow in the distal end of an axis-deviated arterial bypass model Biorheology 46 83 92
    • (2009) Biorheology , vol.46 , pp. 83-92
    • Sun, A.1    Fan, Y.2    Deng, X.3
  • 52
    • 68649113348 scopus 로고    scopus 로고
    • Effect of helicity and rotation on the free decay of turbulent flows
    • 10.1103/PhysRevLett.103.014501
    • T Teitelbaum PD Mininni 2009 Effect of helicity and rotation on the free decay of turbulent flows Phys Rev Lett 103 014501 10.1103/PhysRevLett.103.014501
    • (2009) Phys Rev Lett , vol.103 , pp. 014501
    • Teitelbaum, T.1    Mininni, P.D.2
  • 53
    • 0001435957 scopus 로고
    • On the helical nature of three dimensional coherent structures in turbulent flows
    • 10.1016/0375-9601(83)90896-4
    • A Tsinober E Levich 1983 On the helical nature of three dimensional coherent structures in turbulent flows Phys Lett 99 321 323 10.1016/0375- 9601(83)90896-4
    • (1983) Phys Lett , vol.99 , pp. 321-323
    • Tsinober, A.1    Levich, E.2
  • 55
    • 0032915991 scopus 로고    scopus 로고
    • Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI
    • DOI 10.1002/(SICI)1522-2594(199904)41:4<793::AID-MRM19>3.0.CO;2-2
    • L Wigström T Ebbers A Fyrenius M Karlsson J Engvall B Wranne AF Bolger 1999 Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI Magn Reson Med 41 793 799 10.1002/(SICI)1522-2594(199904)41:4<793::AID-MRM19>3.0.CO;2-2 (Pubitemid 29205727)
    • (1999) Magnetic Resonance in Medicine , vol.41 , Issue.4 , pp. 793-799
    • Wigstrom, L.1    Ebbers, T.2    Fyrenius, A.3    Karlsson, M.4    Engvall, J.5    Wranne, B.6    Bolger, A.F.7
  • 56
    • 36048995640 scopus 로고    scopus 로고
    • Haemodynamics determined by a genetic programme govern asymmetric development of the aortic arch
    • DOI 10.1038/nature06254, PII NATURE06254
    • K Yashiro H Shiratori H Hamada 2007 Haemodynamics determined by a genetic programme govern asymmetric development of the aortic arch Nature 450 285 288 10.1038/nature06254 (Pubitemid 350100536)
    • (2007) Nature , vol.450 , Issue.7167 , pp. 285-288
    • Yashiro, K.1    Shiratori, H.2    Hamada, H.3
  • 57
    • 0020429467 scopus 로고
    • Physiological pulsatile flow experiments in a model of the human aortic arch
    • DOI 10.1016/0021-9290(82)90023-9
    • TL Yearwood KB Chandran 1982 Physiological pulsatile flow experiments in a model of the human aortic arch J Biomech 15 9 683 704 10.1016/0021-9290(82) 90023-9 (Pubitemid 13219972)
    • (1982) Journal of Biomechanics , vol.15 , Issue.9 , pp. 683-704
    • Yearwood, T.L.1    Chandran, K.B.2
  • 58
    • 77951666567 scopus 로고    scopus 로고
    • Swirling flow created in a glass tube suppressed platelet adhesion to the surface of the tube: Its implication in the design of small-caliber arterial grafts
    • 10.1016/j.thromres.2009.02.011
    • F Zhan Y Fan X Deng 2010 Swirling flow created in a glass tube suppressed platelet adhesion to the surface of the tube: its implication in the design of small-caliber arterial grafts Thromb Res 125 5 413 418 10.1016/j.thromres.2009. 02.011
    • (2010) Thromb Res , vol.125 , Issue.5 , pp. 413-418
    • Zhan, F.1    Fan, Y.2    Deng, X.3
  • 59
    • 67650400209 scopus 로고    scopus 로고
    • Hemodynamic performance study on small diameter helical grafts
    • 10.1097/MAT.0b013e31819b34f2
    • T Zheng Y Fan Y Xiong W Jiang X Deng 2009 Hemodynamic performance study on small diameter helical grafts ASAIO J 55 192 199 10.1097/MAT.0b013e31819b34f2
    • (2009) ASAIO J , vol.55 , pp. 192-199
    • Zheng, T.1    Fan, Y.2    Xiong, Y.3    Jiang, W.4    Deng, X.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.