1
-
-
0034267111
-
Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis
-
Gautier E, Perren SM, Cordey J. Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury. 2000;31(suppl 3):C14-C20.
-
(2000)
Injury
, vol.31
, Issue.3 SUPPL.
-
-
Gautier, E.1
Perren, S.M.2
Cordey, J.3
-
2
-
-
0034267497
-
Force transfer between the plate and the bone: Relative importance of the bending stiffness of the screws friction between plate and bone
-
Cordey J, Borgeaud M, Perren SM. Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury. 2000;31(suppl 3):C21-C28.
-
(2000)
Injury
, vol.31
, Issue.3 SUPPL.
-
-
Cordey, J.1
Borgeaud, M.2
Perren, S.M.3
-
3
-
-
77955667477
-
Clinical results for minimally invasive locked plating of proximal humerus fractures
-
Roderer G, Erhardt J, Graf M, et al. Clinical results for minimally invasive locked plating of proximal humerus fractures. J Orthop Trauma. 2010;24:400-406.
-
(2010)
J. Orthop. Trauma.
, vol.24
, pp. 400-406
-
-
Roderer, G.1
Erhardt, J.2
Graf, M.3
-
4
-
-
79955966395
-
Second generation locked plating of proximal humerus fractures-a prospective multicentre observational study
-
Roderer G, Erhardt J, Kuster M, et al. Second generation locked plating of proximal humerus fractures-a prospective multicentre observational study. Int Orthop. 2011;35:425-432.
-
(2011)
Int. Orthop.
, vol.35
, pp. 425-432
-
-
Roderer, G.1
Erhardt, J.2
Kuster, M.3
-
5
-
-
43249095676
-
Early complications in proximal humerus fractures (OTA types 11) treated with locked plates
-
DOI 10.1097/BOT.0b013e318169ef2a, PII 0000513120080300000002
-
Egol KA, Ong CC, Walsh M, et al. Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates. J Orthop Trauma. 2008;22:159-164. (Pubitemid 351654232)
-
(2008)
Journal of Orthopaedic Trauma
, vol.22
, Issue.3
, pp. 159-164
-
-
Egol, K.A.1
Ong, C.C.2
Walsh, M.3
Jazrawi, L.M.4
Tejwani, N.C.5
Zuckerman, J.D.6
-
6
-
-
70349748800
-
Treatment of proximal humerus fractures with locking plates: A systematic review
-
Thanasas C, Kontakis G, Angoules A, et al. Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg. 2009;18:837-844.
-
(2009)
J. Shoulder Elbow Surg.
, vol.18
, pp. 837-844
-
-
Thanasas, C.1
Kontakis, G.2
Angoules, A.3
-
7
-
-
78549267138
-
The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support
-
Lescheid J, Zdero R, Shah S, et al. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. J Trauma. 2010;69:1235-1242.
-
(2010)
J. Trauma.
, vol.69
, pp. 1235-1242
-
-
Lescheid, J.1
Zdero, R.2
Shah, S.3
-
8
-
-
77951798523
-
Pathological fractures of the proximal humerus treated with a proximal humeral locking plate and bone cement
-
Siegel HJ, Lopez-Ben R, Mann JP, et al. Pathological fractures of the proximal humerus treated with a proximal humeral locking plate and bone cement. J Bone Joint Surg Br. 2010;92:707-712.
-
(2010)
J. Bone Joint Surg. Br.
, vol.92
, pp. 707-712
-
-
Siegel, H.J.1
Lopez-Ben, R.2
Mann, J.P.3
-
9
-
-
78650758688
-
Fracture of the distal radius: Risk factors for complications after locked volar plate fixation
-
Soong M, van Leerdam R, Guitton TG, et al. Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am. 2010;36:3-9.
-
(2010)
J. Hand Surg. Am.
, vol.36
, pp. 3-9
-
-
Soong, M.1
Van Leerdam, R.2
Guitton, T.G.3
-
10
-
-
77649272692
-
Internal fixation of intracapsular hip fractures with a dynamic locking plate: Initial experience and results for 83 patients treated with a new implant
-
Parker MJ, Stedtfeld HW. Internal fixation of intracapsular hip fractures with a dynamic locking plate: initial experience and results for 83 patients treated with a new implant. Injury. 2010;41:348-351.
-
(2010)
Injury
, vol.41
, pp. 348-351
-
-
Parker, M.J.1
Stedtfeld, H.W.2
-
11
-
-
77954632565
-
Internal fixation of type-C distal femoral fractures in osteoporotic bone
-
Wahnert D, Hoffmeier KL, von Oldenburg G, et al. Internal fixation of type-C distal femoral fractures in osteoporotic bone. J Bone Joint Surg Am. 2010;92:1442-1452.
-
(2010)
J. Bone Joint Surg. Am.
, vol.92
, pp. 1442-1452
-
-
Wahnert, D.1
Hoffmeier, K.L.2
Von Oldenburg, G.3
-
12
-
-
67650576430
-
Fixation of distal femoral fractures with the Less Invasive Stabilization System: A minimally invasive treatment with locked fixed-angle screws
-
Kolb W, Guhlmann H, Windisch C, et al. Fixation of distal femoral fractures with the Less Invasive Stabilization System: a minimally invasive treatment with locked fixed-angle screws. J Trauma. 2008;65:1425-1434.
-
(2008)
J. Trauma.
, vol.65
, pp. 1425-1434
-
-
Kolb, W.1
Guhlmann, H.2
Windisch, C.3
-
13
-
-
67651062204
-
Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate
-
Ebraheim NA, Gomez C, Ramineni SK, et al. Fixation of periprosthetic femoral shaft fractures adjacent to a well-fixed femoral stem with reversed distal femoral locking plate. J Trauma. 2009;66:1152-117.
-
(2009)
J. Trauma.
, vol.66
, pp. 1152-1117
-
-
Ebraheim, N.A.1
Gomez, C.2
Ramineni, S.K.3
-
14
-
-
79956191670
-
Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants
-
September 2, Epub ahead of print
-
Wood GC, Naudie DR, McAuley J, et al. Locking compression plates for the treatment of periprosthetic femoral fractures around well-fixed total hip and knee implants. J Arthroplasty. September 2, 2010. [Epub ahead of print].
-
(2010)
J. Arthroplasty
-
-
Wood, G.C.1
Naudie, D.R.2
McAuley, J.3
-
15
-
-
26044432463
-
Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant
-
DOI 10.2106/JBJS.D.01911
-
Ricci WM, Bolhofner BR, Loftus T, et al. Indirect reduction and plate fixation, without grafting, for periprosthetic femoral shaft fractures about a stable intramedullary implant. J Bone Joint Surg Am. 2005;87:2240-2245. (Pubitemid 41407549)
-
(2005)
Journal of Bone and Joint Surgery - Series A
, vol.87
, Issue.10
, pp. 2240-2245
-
-
Ricci, W.M.1
Bolhofner, B.R.2
Loftus, T.3
Cox, C.4
Mitchell, S.5
Borrelli Jr., J.6
-
16
-
-
33646843548
-
Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty
-
DOI 10.1097/00005131-200603000-00005, PII 0000513120060300000005
-
Ricci WM, Loftus T, Cox C, et al. Locked plates combined with minimally invasive insertion technique for the treatment of periprosthetic supracondylar femur fractures above a total knee arthroplasty. J Orthop Trauma. 2006;20:190-196. (Pubitemid 44315027)
-
(2006)
Journal of Orthopaedic Trauma
, vol.20
, Issue.3
, pp. 190-196
-
-
Ricci, W.M.1
Loftus, T.2
Cox, C.3
Borrelli, J.4
-
17
-
-
77957574192
-
Fixation of periprosthetic femur fractures above total knee arthroplasty with the less invasive stabilization system: A midterm follow-up study
-
Kolb W, Guhlmann H, Windisch C, et al. Fixation of periprosthetic femur fractures above total knee arthroplasty with the less invasive stabilization system: a midterm follow-up study. J Trauma. 2010;69:670-676.
-
(2010)
J. Trauma.
, vol.69
, pp. 670-676
-
-
Kolb, W.1
Guhlmann, H.2
Windisch, C.3
-
18
-
-
39449083297
-
Treatment of acute distal femur fractures above a total knee arthroplasty: Systematic review of 415 cases (1981-2006)
-
DOI 10.1080/17453670710014716, PII 790661327
-
Herrera DA, Kregor PJ, Cole PA, et al. Treatment of acute distal femur fractures above a total knee arthroplasty: systematic review of 415 cases (1981-2006). Acta Orthop. 2008;79:22-27. (Pubitemid 351271878)
-
(2008)
Acta Orthopaedica
, vol.79
, Issue.1
, pp. 22-27
-
-
Herrera, D.A.1
Kregor, P.J.2
Cole, P.A.3
Levy, B.A.4
Jonsson, A.5
Zlowodzki, M.6
-
19
-
-
46049093362
-
Locked plating in orthopaedic trauma: A clinical update
-
Haidukewych GJ, Ricci W. Locked plating in orthopaedic trauma: a clinical update. J Am Acad Orthop Surg. 2008;16:347-355.
-
(2008)
J. Am. Acad. Orthop. Surg.
, vol.16
, pp. 347-355
-
-
Haidukewych, G.J.1
Ricci, W.2
-
20
-
-
7444234973
-
Innovations in locking plate technology
-
Haidukewych GJ. Innovations in locking plate technology. J Am Acad Orthop Surg. 2004;12:205-212.
-
(2004)
J. Am. Acad. Orthop. Surg.
, vol.12
, pp. 205-212
-
-
Haidukewych, G.J.1
-
22
-
-
77953154707
-
Technical problems and complications in the removal of the less invasive stabilization system
-
Suzuki T, Smith WR, Stahel PF, et al. Technical problems and complications in the removal of the less invasive stabilization system. J Orthop Trauma. 2010;24:369-373.
-
(2010)
J. Orthop. Trauma.
, vol.24
, pp. 369-373
-
-
Suzuki, T.1
Smith, W.R.2
Stahel, P.F.3
|