메뉴 건너뛰기




Volumn 22, Issue 3, 2008, Pages 159-164

Early complications in proximal humerus fractures (OTA types 11) treated with locked plates

Author keywords

Complication; Fracture; Locking plate; Proximal humerus

Indexed keywords

ADULT; AGED; ARTHROPLASTY; ARTICLE; BONE GRAFT; BONE NECROSIS; BONE PLATE; BONE RADIOGRAPHY; BONE SCREW; FEMALE; FOLLOW UP; FRACTURE NONUNION; GRAFT FAILURE; GROUPS BY AGE; HUMAN; HUMERUS FRACTURE; ILIAC BONE; ILIAC CREST; MAJOR CLINICAL STUDY; MALE; OSTEOSYNTHESIS; PEROPERATIVE COMPLICATION; PHYSICAL EXAMINATION; POSTOPERATIVE COMPLICATION; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SHOULDER; STATISTICAL ANALYSIS; SURGICAL ERROR; TREATMENT FAILURE; UNIVERSITY HOSPITAL;

EID: 43249095676     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e318169ef2a     Document Type: Article
Times cited : (187)

References (24)
  • 1
    • 0016696340 scopus 로고
    • Epidemiology of fracture of the upper end of the humerus
    • Horak J, Nilsson BE. Epidemiology of fracture of the upper end of the humerus. Clin Orthop Relat Res. 1975;112:250-253.
    • (1975) Clin Orthop Relat Res , vol.112 , pp. 250-253
    • Horak, J.1    Nilsson, B.E.2
  • 2
    • 10944263139 scopus 로고    scopus 로고
    • Internal fixation of proximal humeral fractures with a locking compression plate: A retrospective evaluation of 72 patients followed for a minimum of 1 year
    • Bjorkenheim JM, Pajarinen J, Savolainen V. Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand. 2004;75:741-745.
    • (2004) Acta Orthop Scand , vol.75 , pp. 741-745
    • Bjorkenheim, J.M.1    Pajarinen, J.2    Savolainen, V.3
  • 3
    • 4444231519 scopus 로고    scopus 로고
    • Internal fixation of complex fractures of the proximal humerus
    • Gerber C, Werner CM, Vienne P. Internal fixation of complex fractures of the proximal humerus. J Bone Joint Surg Br. 2004;86:848-855.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 848-855
    • Gerber, C.1    Werner, C.M.2    Vienne, P.3
  • 4
    • 0034152245 scopus 로고    scopus 로고
    • Randomized prospective study of humeral shaft fracture fixation: Intramedullary nails versus plates
    • Chapman JR, Henley MB, Agel J, et al. Randomized prospective study of humeral shaft fracture fixation: intramedullary nails versus plates. J Orthop Trauma. 2000;14:162-166.
    • (2000) J Orthop Trauma , vol.14 , pp. 162-166
    • Chapman, J.R.1    Henley, M.B.2    Agel, J.3
  • 5
    • 11844254362 scopus 로고    scopus 로고
    • A new locking plate for unstable fractures of the proximal humerus
    • Fankhauser F, Boldin C, Schippinger G, et al. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 2005;430:176-181.
    • (2005) Clin Orthop Relat Res , vol.430 , pp. 176-181
    • Fankhauser, F.1    Boldin, C.2    Schippinger, G.3
  • 6
    • 0026659303 scopus 로고
    • Percutaneous stabilization of unstable fractures of the humerus
    • Jaberg H, Warner JJ, Jakob RP. Percutaneous stabilization of unstable fractures of the humerus. J Bone Joint Surg Am. 1992;74:508-515.
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 508-515
    • Jaberg, H.1    Warner, J.J.2    Jakob, R.P.3
  • 9
    • 0036844148 scopus 로고    scopus 로고
    • Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus
    • Wijgman AJ, Roolker W, Patt TW, et al. Open reduction and internal fixation of three and four-part fractures of the proximal part of the humerus. J Bone Joint Surg Am. 2002;84-A:1919-1925.
    • (2002) J Bone Joint Surg Am , vol.84-A , pp. 1919-1925
    • Wijgman, A.J.1    Roolker, W.2    Patt, T.W.3
  • 10
    • 0038338590 scopus 로고    scopus 로고
    • Proximal humeral fractures: How stiff should an implant be? A comparative mechanical study with new implants in human specimens
    • Lill H, Hepp P, Korner J, et al. Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens. Arch Orthop Trauma Surg. 2003;123:74-81.
    • (2003) Arch Orthop Trauma Surg , vol.123 , pp. 74-81
    • Lill, H.1    Hepp, P.2    Korner, J.3
  • 11
    • 4444358605 scopus 로고    scopus 로고
    • Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: Clinical experience and a laboratory comparison with double plating
    • Egol KA, Su E, Tejwani NC, et al. Treatment of complex tibial plateau fractures using the less invasive stabilization system plate: clinical experience and a laboratory comparison with double plating. J Trauma. 2004;57:340-346.
    • (2004) J Trauma , vol.57 , pp. 340-346
    • Egol, K.A.1    Su, E.2    Tejwani, N.C.3
  • 12
    • 33646477698 scopus 로고    scopus 로고
    • Fixation of diaphyseal fractures with a segmental defect: A biomechanical comparison of locked and conventional plating techniques
    • Fulkerson E, Egol KA, Kubiak EN, et al. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques. J Trauma. 2006;60:830-835.
    • (2006) J Trauma , vol.60 , pp. 830-835
    • Fulkerson, E.1    Egol, K.A.2    Kubiak, E.N.3
  • 13
    • 33645064868 scopus 로고    scopus 로고
    • Fixation of proximal humerus fractures using the PHILOS plate: Early experience
    • Koukakis A, Apostolou CD, Taneja T, et al. Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res. 2006;442:115-120.
    • (2006) Clin Orthop Relat Res , vol.442 , pp. 115-120
    • Koukakis, A.1    Apostolou, C.D.2    Taneja, T.3
  • 14
    • 1542289158 scopus 로고    scopus 로고
    • The angle stable locking-proximal- humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results]
    • Lill H, Hepp P, Rose T, et al. [The angle stable locking-proximal- humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results]. Zentralbl Chir. 2004;129:43-48.
    • (2004) Zentralbl Chir , vol.129 , pp. 43-48
    • Lill, H.1    Hepp, P.2    Rose, T.3
  • 15
    • 14944348757 scopus 로고    scopus 로고
    • Internal fixation of proximal humerus fractures using the locking proximal humerus plate
    • Plecko M, Kraus A. Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Oper Orthop Traumatol. 2005;17:25-50.
    • (2005) Oper Orthop Traumatol , vol.17 , pp. 25-50
    • Plecko, M.1    Kraus, A.2
  • 16
    • 0012513163 scopus 로고    scopus 로고
    • Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996;10(Suppl 1):v-ix, 1-154.
    • Fracture and dislocation compendium. Orthopaedic Trauma Association Committee for Coding and Classification. J Orthop Trauma. 1996;10(Suppl 1):v-ix, 1-154.
  • 17
    • 85069106848 scopus 로고    scopus 로고
    • Open Reduction and Internal Fixation of three and four part fractures and fracture dislocations: Locking plate
    • Zuckerman JD ed, Rosemeont, IL: American Academy of Orthopaedic Surgeons
    • Egol K. Open Reduction and Internal Fixation of three and four part fractures and fracture dislocations: Locking plate. In: Advanced Reconstruction Shoulder. Zuckerman JD (ed). Rosemeont, IL: American Academy of Orthopaedic Surgeons, 2007; 265-273.
    • (2007) Advanced Reconstruction Shoulder , pp. 265-273
    • Egol, K.1
  • 18
    • 34247563357 scopus 로고    scopus 로고
    • The importance of medial support in locked plating of proximal humerus fractures
    • Gardner MJ, Weil Y, Barker JU, et al. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21:185-191.
    • (2007) J Orthop Trauma , vol.21 , pp. 185-191
    • Gardner, M.J.1    Weil, Y.2    Barker, J.U.3
  • 19
    • 0014851643 scopus 로고    scopus 로고
    • Neer CS, 2nd. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am. 1970;52:1077-1089.
    • Neer CS, 2nd. Displaced proximal humeral fractures. I. Classification and evaluation. J Bone Joint Surg Am. 1970;52:1077-1089.
  • 20
    • 0141452006 scopus 로고    scopus 로고
    • Severely impacted valgus proximal humeral fractures. Results of operative treatment
    • Robinson CM, Page RS. Severely impacted valgus proximal humeral fractures. Results of operative treatment. J Bone Joint Surg Am. 2003;85-A:1647-1655.
    • (2003) J Bone Joint Surg Am , vol.85-A , pp. 1647-1655
    • Robinson, C.M.1    Page, R.S.2
  • 21
    • 0142138198 scopus 로고    scopus 로고
    • Guidelines for the clinical application of the LCP
    • Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63-76.
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Gautier, E.1    Sommer, C.2
  • 22
    • 33750693402 scopus 로고    scopus 로고
    • Vascular implications of minimally invasive plating of proximal humerus fractures
    • Gardner MJ, Voos JE, Wanich T, et al. Vascular implications of minimally invasive plating of proximal humerus fractures. J Orthop Trauma. 2006;20:602-607.
    • (2006) J Orthop Trauma , vol.20 , pp. 602-607
    • Gardner, M.J.1    Voos, J.E.2    Wanich, T.3
  • 23
    • 7444234973 scopus 로고    scopus 로고
    • Innovations in locking plate technology
    • Haidukewych GJ. Innovations in locking plate technology. J Am Acad Orthop Surg. 2004;12:205-212.
    • (2004) J Am Acad Orthop Surg , vol.12 , pp. 205-212
    • Haidukewych, G.J.1
  • 24
    • 0021365109 scopus 로고    scopus 로고
    • Zuckerman JD, Matsen FA 3rd. Complications about the glenohumeral joint related to the use of screws and staples. J Bone Joint Surg Am. 1984;66:175-180.
    • Zuckerman JD, Matsen FA 3rd. Complications about the glenohumeral joint related to the use of screws and staples. J Bone Joint Surg Am. 1984;66:175-180.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.