메뉴 건너뛰기




Volumn 31, Issue SUPPL.3, 2000, Pages

Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis

Author keywords

Composite beam theory; Modulus of elasticity; Oblique bending; Plate osteosynthesis; Steel plate; Titanium plate

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 0034267111     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0020-1383(00)80027-3     Document Type: Article
Times cited : (36)

References (18)
  • 1
    • 0034267112 scopus 로고    scopus 로고
    • Strain distribution in the plated and unplated sheep tibia. An "in vivo experiment"
    • Gautier E. Strain distribution in the plated and unplated sheep tibia. An "in vivo experiment". Injury 2000;31 (S3): 37-44.
    • (2000) Injury , vol.31 , Issue.S3 , pp. 37-44
    • Gautier, E.1
  • 2
    • 0016258811 scopus 로고
    • In-vivo-Messung der belastungsabhängigen Knochendehnung
    • Brennwald J and Perren SM. In-vivo-Messung der belastungsabhängigen Knochendehnung. Helv. Chir. Acta 1974;41:455-457.
    • (1974) Helv. Chir. Acta , vol.41 , pp. 455-457
    • Brennwald, J.1    Perren, S.M.2
  • 3
    • 0014652503 scopus 로고
    • Effects of internal fixation plates on mechanical deformation of bone
    • Cochran GVB. Effects of internal fixation plates on mechanical deformation of bone. Orthop Surg. 1969;20:469-471.
    • (1969) Orthop Surg. , vol.20 , pp. 469-471
    • Cochran, G.V.B.1
  • 4
    • 0008129592 scopus 로고
    • In vivo strain gauge study of bone response to loading with and without internal fixation
    • Uhthoff HK ed. Berlin Heidelberg New York: Springer Verlag
    • Schatzker J, Manley PA and Summer-Smith G. In vivo strain gauge study of bone response to loading with and without internal fixation. In: Uhthoff HK ed. Current concepts of internal fixation of fractures. Berlin Heidelberg New York: Springer Verlag, 1980:306-314.
    • (1980) Current Concepts of Internal Fixation of Fractures , pp. 306-314
    • Schatzker, J.1    Manley, P.A.2    Summer-Smith, G.3
  • 5
    • 0008033064 scopus 로고
    • Bestimmung der Knochendehnung in vitro und in vivo nach Plattenosteosynthese
    • Brennwald J and Perren SM. Bestimmung der Knochendehnung in vitro und in vivo nach Plattenosteosynthese. Langenbecks Arch. Chir. 1972 (Suppl).
    • (1972) Langenbecks Arch. Chir. , Issue.SUPPL.
    • Brennwald, J.1    Perren, S.M.2
  • 7
    • 0016810862 scopus 로고
    • Quantitative histological evaluation of early fracture healing of cortical bone immobilized by stainless steel and composite plates
    • Akeson WH, Woo SLY, Coutts RD, Matthews JV, Gonsalves M and Amiel D. Quantitative histological evaluation of early fracture healing of cortical bone immobilized by stainless steel and composite plates. Calcif. Tissue Res. 1975;19:27-37.
    • (1975) Calcif. Tissue Res. , vol.19 , pp. 27-37
    • Akeson, W.H.1    Woo, S.L.Y.2    Coutts, R.D.3    Matthews, J.V.4    Gonsalves, M.5    Amiel, D.6
  • 9
    • 0018026372 scopus 로고
    • Effects on intact femora of dogs of the application and removal of metal plates
    • Moyen BHL, Lahey PJ, Weinberg EH and Harris WH. Effects on intact femora of dogs of the application and removal of metal plates. J. Bone Joint Surg. 1978;60-A:940-947.
    • (1978) J. Bone Joint Surg. , vol.60 A , pp. 940-947
    • Moyen, B.H.L.1    Lahey, P.J.2    Weinberg, E.H.3    Harris, W.H.4
  • 10
    • 0019442164 scopus 로고
    • Experimentelle Untersuchungen zum Einfluss des Plattenmaterials auf die Entlastung und die Atrophie des Knochens unter Osteosyntheseplatten
    • Claes L, Kinzl L and Neugebauer R. Experimentelle Untersuchungen zum Einfluss des Plattenmaterials auf die Entlastung und die Atrophie des Knochens unter Osteosyntheseplatten. Biomed. Tech. 1981;26:66-71.
    • (1981) Biomed. Tech. , vol.26 , pp. 66-71
    • Claes, L.1    Kinzl, L.2    Neugebauer, R.3
  • 11
    • 0019409452 scopus 로고
    • The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures
    • Uhthoff HK, Bardos DI and Liskova-Kiar M. The advantages of titanium alloy over stainless steel plates for the internal fixation of fractures. J. Bone Joint Surg. 1981;63-B:427-434.
    • (1981) J. Bone Joint Surg. , vol.63 B , pp. 427-434
    • Uhthoff, H.K.1    Bardos, D.I.2    Liskova-Kiar, M.3
  • 12
    • 0020670519 scopus 로고
    • The effects of metal plates on post-traumatic remodelling and bone mass
    • Uhthoff HK and Finnigan M. The effects of metal plates on post-traumatic remodelling and bone mass. J. Bone Joint Surg. 1983;65-B:66-71.
    • (1983) J. Bone Joint Surg. , vol.65 B , pp. 66-71
    • Uhthoff, H.K.1    Finnigan, M.2
  • 16
    • 18544404664 scopus 로고    scopus 로고
    • Strain gauges used in the mechanical testing of bones. Part III: Strain analysis, graphic determination of the neutral axis
    • Cordey J, Gautier E. Strain gauges used in the mechanical testing of bones. Part III: Strain analysis, graphic determination of the neutral axis. Injury 1999;30 (S1): 21-25.
    • (1999) Injury , vol.30 , Issue.S1 , pp. 21-25
    • Cordey, J.1    Gautier, E.2
  • 18
    • 10644287586 scopus 로고    scopus 로고
    • Steiner J. cited in Müller H (1796-1836) [14]
    • Steiner J. cited in Müller H (1796-1836) [14].


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.