메뉴 건너뛰기




Volumn 26, Issue 4, 2011, Pages 666.e5-666.e8

Fracture of a Cross-Linked Polyethylene Liner. A Multifactorial Issue

Author keywords

Fatigue fracture; Highly cross linked polyethylene; Liner exchange; Revision total hip arthroplasty

Indexed keywords

POLYETHYLENE;

EID: 79955966749     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2010.07.009     Document Type: Article
Times cited : (44)

References (17)
  • 2
    • 0026662669 scopus 로고
    • Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space
    • Schmalzried T.P., Jasty M., Harris W.H. Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am 1992, 6:849.
    • (1992) J Bone Joint Surg Am , vol.6 , pp. 849
    • Schmalzried, T.P.1    Jasty, M.2    Harris, W.H.3
  • 3
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H., Shen F.W., Lu B., et al. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999, 17:157.
    • (1999) J Orthop Res , vol.17 , pp. 157
    • McKellop, H.1    Shen, F.W.2    Lu, B.3
  • 4
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz S.M., Muratoglu O.K., Evans M., et al. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999, 20:1659.
    • (1999) Biomaterials , vol.20 , pp. 1659
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3
  • 5
    • 0041386214 scopus 로고    scopus 로고
    • Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator
    • D'Lima D.D., Hermida J.C., Chen P.C., et al. Polyethylene cross-linking by two different methods reduces acetabular liner wear in a hip joint wear simulator. J Orthop Res 2003, 21:761.
    • (2003) J Orthop Res , vol.21 , pp. 761
    • D'Lima, D.D.1    Hermida, J.C.2    Chen, P.C.3
  • 6
    • 34548225119 scopus 로고    scopus 로고
    • Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and non-cross-linked polyethylene
    • Leung S.B., Egawa H., Stepniewski A., et al. Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and non-cross-linked polyethylene. J Arthroplasty 2007, 22(6 Suppl 2):134.
    • (2007) J Arthroplasty , vol.22 , Issue.6 SUPPL. 2 , pp. 134
    • Leung, S.B.1    Egawa, H.2    Stepniewski, A.3
  • 7
    • 9644254123 scopus 로고    scopus 로고
    • Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
    • Digas G., Karrholm J., Thanner J., et al. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop 2004, 429:6.
    • (2004) Clin Orthop , vol.429 , pp. 6
    • Digas, G.1    Karrholm, J.2    Thanner, J.3
  • 8
    • 26444468492 scopus 로고    scopus 로고
    • Early femoral head penetration of a highly cross-linked polyethylene liner vs. a conventional polyethylene liner: a case-controlled study
    • Krushell R.J., Fingeroth R.J., Cushing M.C. Early femoral head penetration of a highly cross-linked polyethylene liner vs. a conventional polyethylene liner: a case-controlled study. J Arthroplasty 2005, 20(7 Suppl 3):73.
    • (2005) J Arthroplasty , vol.20 , Issue.7 SUPPL. 3 , pp. 73
    • Krushell, R.J.1    Fingeroth, R.J.2    Cushing, M.C.3
  • 9
    • 36849009829 scopus 로고    scopus 로고
    • Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty
    • Jacobs C.A., Christensen C.P., Greenwald A.S., et al. Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am 2007, 89:2779.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2779
    • Jacobs, C.A.1    Christensen, C.P.2    Greenwald, A.S.3
  • 10
    • 0036381521 scopus 로고    scopus 로고
    • Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE
    • Cole J.C., Lemons J.E., Eberhardt A.W. Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE. J Biomed Mater Res 2002, 63:559.
    • (2002) J Biomed Mater Res , vol.63 , pp. 559
    • Cole, J.C.1    Lemons, J.E.2    Eberhardt, A.W.3
  • 11
    • 0141447819 scopus 로고    scopus 로고
    • The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene
    • Baker D.A., Bellare A., Pruitt L. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res 2003, 66A:146.
    • (2003) J Biomed Mater Res , vol.66 A , pp. 146
    • Baker, D.A.1    Bellare, A.2    Pruitt, L.3
  • 12
    • 0346259931 scopus 로고    scopus 로고
    • Prediction of multiaxial mechanical behavior for conventional and highly crosslinked UHMWPE using a hybrid constitutive model
    • Bergstrom J.S., Rimnac C.M., Kurtz S.M. Prediction of multiaxial mechanical behavior for conventional and highly crosslinked UHMWPE using a hybrid constitutive model. Biomaterials 2003, 24:1365.
    • (2003) Biomaterials , vol.24 , pp. 1365
    • Bergstrom, J.S.1    Rimnac, C.M.2    Kurtz, S.M.3
  • 13
    • 57649097317 scopus 로고    scopus 로고
    • Fracture of a cross-linked polyethylene liner due to impingement
    • Duffy G.P., Wannomae K.K., Rowell S.L., et al. Fracture of a cross-linked polyethylene liner due to impingement. J Arthroplasty 2009, 24:158.
    • (2009) J Arthroplasty , vol.24 , pp. 158
    • Duffy, G.P.1    Wannomae, K.K.2    Rowell, S.L.3
  • 14
    • 1842473877 scopus 로고    scopus 로고
    • Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report
    • Halley D., Glassman A., Crowninshield R.D. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. A case report. J Bone Joint Surg Am 2004, 86:827.
    • (2004) J Bone Joint Surg Am , vol.86 , pp. 827
    • Halley, D.1    Glassman, A.2    Crowninshield, R.D.3
  • 15
    • 35349019671 scopus 로고    scopus 로고
    • Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty
    • Tower S.S., Currier J.H., Currier B.H., et al. Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am 2007, 89:2212.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2212
    • Tower, S.S.1    Currier, J.H.2    Currier, B.H.3
  • 16
    • 55849150871 scopus 로고    scopus 로고
    • Early failure of a cross-linked polyethylene acetabular liner. A case report
    • Moore K.D., Beck P.R., Petersen D.W., et al. Early failure of a cross-linked polyethylene acetabular liner. A case report. J Bone Joint Surg Am 2008, 90:2499.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2499
    • Moore, K.D.1    Beck, P.R.2    Petersen, D.W.3
  • 17
    • 46749151403 scopus 로고    scopus 로고
    • Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report
    • Bitsch R.G., Loidolt T., Heisel C., et al. Reduction of osteolysis with use of Marathon cross-linked polyethylene. A concise follow-up, at a minimum of five years, of a previous report. J Bone Joint Surg Am 2008, 90:1487.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1487
    • Bitsch, R.G.1    Loidolt, T.2    Heisel, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.