메뉴 건너뛰기




Volumn 63, Issue 5, 2002, Pages 559-566

Gamma irradiation alters fatigue-crack behavior and fracture toughness in 1900H and GUR 1050 UHMWPE

Author keywords

Fatigue; Fracture toughness; Gamma irradiation; Polyethylene

Indexed keywords

CROSSLINKING; DOSIMETRY; FATIGUE OF MATERIALS; GAMMA RAYS; MOLECULAR WEIGHT; POLYETHYLENES; WEAR RESISTANCE;

EID: 0036381521     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.10335     Document Type: Article
Times cited : (55)

References (36)
  • 1
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
    • McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999;17:157-167.
    • (1999) J Orthop Res , vol.17 , pp. 157-167
    • McKellop, H.1    Shen, F.W.2    Lu, B.3    Campbell, P.4    Salovey, R.5
  • 3
    • 0001486818 scopus 로고
    • Long term clinical results of THR. Clinical results of THR of an alumina head with a crosslinked UHMWPE cup
    • Oonishi, H. Long term clinical results of THR. Clinical results of THR of an alumina head with a crosslinked UHMWPE cup. Orthop Surg Traumatol 1995;38:1255-64.
    • (1995) Orthop Surg Traumatol , vol.38 , pp. 1255-1264
    • Oonishi, H.1
  • 4
    • 0032775639 scopus 로고    scopus 로고
    • Advances in processing, sterilization and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muatoglu OK, Evans M, Edidin AA. Advances in processing, sterilization and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999;20:1659-1688.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muatoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 6
    • 2142750290 scopus 로고    scopus 로고
    • Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by hip and knee simulators
    • Wang A, Polineni VK, Essner A, Sun DC, Stark C, Dumbleton JH. Effect of radiation dosage on the wear of stabilized UHMWPE evaluated by hip and knee simulators. In Proc 23rd Soc Biomater; 1997. Vol. 20, p 363.
    • (1997) Proc 23rd Soc Biomater , vol.20 , pp. 363
    • Wang, A.1    Polineni, V.K.2    Essner, A.3    Sun, D.C.4    Stark, C.5    Dumbleton, J.H.6
  • 7
    • 0002572722 scopus 로고    scopus 로고
    • Extremely low wear of gamma crosslinked/remelted UHMW polyethylene acetabular cups
    • McKellop H, Shen FW, Salovey R. Extremely low wear of gamma crosslinked/remelted UHMW polyethylene acetabular cups. In: Trans 44th Annu Meet Orthop Res Soc; 1998. Vol. 23, p 98.
    • (1998) Trans 44th Annu Meet Orthop Res Soc , vol.23 , pp. 98
    • McKellop, H.1    Shen, F.W.2    Salovey, R.3
  • 8
    • 0038644243 scopus 로고    scopus 로고
    • Direct correlation of abrasive wear resistance of irradiation-crosslinked UHMWPE with large deformation mechanical behavior determined at articulating surfaces
    • Edidin AA, Jewett CW, Foulds JR, Kurtz SM. Direct correlation of abrasive wear resistance of irradiation-crosslinked UHMWPE with large deformation mechanical behavior determined at articulating surfaces. In: Proc 24th Soc Biomater; 1998. Vol. 21, p 220.
    • (1998) Proc 24th Soc Biomater , vol.21 , pp. 220
    • Edidin, A.A.1    Jewett, C.W.2    Foulds, J.R.3    Kurtz, S.M.4
  • 10
    • 0031148607 scopus 로고    scopus 로고
    • Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene
    • Pascaud RS, Evans WT, McCullagh PJ, Fitzpatrick DP. Influence of gamma-irradiation sterilization and temperature on the fracture toughness of ultra-high-molecular-weight polyethylene. Biomaterials 1997;18:727-735.
    • (1997) Biomaterials , vol.18 , pp. 727-735
    • Pascaud, R.S.1    Evans, W.T.2    McCullagh, P.J.3    Fitzpatrick, D.P.4
  • 11
    • 0000100076 scopus 로고    scopus 로고
    • The effect of resin grade, manufacturing method and cross-linking on the fracture toughness of commercially available UHMWPE
    • Duus, LC, Walsh HA, Gillis AM, Noisiez E, Li S. The effect of resin grade, manufacturing method and cross-linking on the fracture toughness of commercially available UHMWPE. In: Trans 46th Annu Meet Orthop Res Soc; 2000. p 544.
    • (2000) Trans 46th Annu Meet Orthop Res Soc , pp. 544
    • Duus, L.C.1    Walsh, H.A.2    Gillis, A.M.3    Noisiez, E.4    Li, S.5
  • 12
    • 0001129670 scopus 로고    scopus 로고
    • An independent evaluation of the mechanical, chemical and fracture properties of UHMWPE crosslinked by 34 different conditions
    • Gillis AM, Schmieg JJ, Bhattacharyya S, Li S. An independent evaluation of the mechanical, chemical and fracture properties of UHMWPE crosslinked by 34 different conditions. In: Trans 45th Annu Meet Orthop Res Soc; 1999. p 908.
    • (1999) Trans 45th Annu Meet Orthop Res Soc , pp. 908
    • Gillis, A.M.1    Schmieg, J.J.2    Bhattacharyya, S.3    Li, S.4
  • 13
    • 0033567865 scopus 로고    scopus 로고
    • Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
    • Baker DA, Hastings RS, Pruitt L. Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res 1999;46:573-581.
    • (1999) J Biomed Mater Res , vol.46 , pp. 573-581
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 15
    • 0020826593 scopus 로고
    • Retrieval analysis of total knee prostheses: A method and its applications to 48 condylar prostheses
    • Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: A method and its applications to 48 condylar prostheses. J Biomed Mater Res 1983;17:829-842.
    • (1983) J Biomed Mater Res , vol.17 , pp. 829-842
    • Hood, R.W.1    Wright, T.M.2    Burstein, A.H.3
  • 16
    • 0022504260 scopus 로고
    • The problem of surface damage in polyethylene total knee components
    • Wright TM, Bartel DL. The problem of surface damage in polyethylene total knee components. Clin Orthop 1986;205:67-74.
    • (1986) Clin Orthop , vol.205 , pp. 67-74
    • Wright, T.M.1    Bartel, D.L.2
  • 17
    • 0032438463 scopus 로고    scopus 로고
    • The impact of sterilization method on wear in knee arthroplasty
    • Williams IR, Mayor MB, Collier JP. The impact of sterilization method on wear in knee arthroplasty. Clin Orthop Relat Res 1998;356:170-180:.
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 170-180
    • Williams, I.R.1    Mayor, M.B.2    Collier, J.P.3
  • 19
    • 2142757394 scopus 로고    scopus 로고
    • The role of fatigue crack initiation vs propagation in delamination wear of tibial knee inserts
    • Jani SC, Long M. The role of fatigue crack initiation vs propagation in delamination wear of tibial knee inserts. Proc 27th Soc Biomater; 2001. p 486.
    • (2001) Proc 27th Soc Biomater , pp. 486
    • Jani, S.C.1    Long, M.2
  • 21
    • 0011177541 scopus 로고    scopus 로고
    • Factors that determine the oxidation resistance of molded 1900: Is it the resin or the molding?
    • Walsh H, Gillis A, Furman B, Li S. Factors that determine the oxidation resistance of molded 1900: Is it the resin or the molding? In: Trans 46th Annu Meet Orthop Res Soc; 2000. p 12.
    • (2000) Trans 46th Annu Meet Orthop Res Soc , pp. 12
    • Walsh, H.1    Gillis, A.2    Furman, B.3    Li, S.4
  • 22
    • 0021907528 scopus 로고
    • A comparison of RCH 1000 and Hi-Fax 1900 ultra-high molecular weight polyethylenes
    • Weightman B, Light D. A comparison of RCH 1000 and Hi-Fax 1900 ultra-high molecular weight polyethylenes. Biomaterials 1984;6:177-183.
    • (1984) Biomaterials , vol.6 , pp. 177-183
    • Weightman, B.1    Light, D.2
  • 23
    • 0034106173 scopus 로고    scopus 로고
    • Effect of fabrication method and resin type on performance of tibial bearings
    • Currier BH, Currier JH, Collier JP, Mayor MB. Effect of fabrication method and resin type on performance of tibial bearings. J Biomed Mater Res 2000;53:143-151.
    • (2000) J Biomed Mater Res , vol.53 , pp. 143-151
    • Currier, B.H.1    Currier, J.H.2    Collier, J.P.3    Mayor, M.B.4
  • 24
    • 0033922918 scopus 로고    scopus 로고
    • Effect of resin type and manufacturing method on wear of polyethylene tibial components
    • Won CH, Rohatgi S, Kraay MJ, Goldberg VM, Rimnac CM. Effect of resin type and manufacturing method on wear of polyethylene tibial components. Clin Orthop Relat Res 2000;376:161-171.
    • (2000) Clin Orthop Relat Res , vol.376 , pp. 161-171
    • Won, C.H.1    Rohatgi, S.2    Kraay, M.J.3    Goldberg, V.M.4    Rimnac, C.M.5
  • 25
    • 0010496551 scopus 로고    scopus 로고
    • Montell 1900 degrades faster than GUR 1050 during accelerated aging after gamma irradiation in air
    • Edidin AA, Muth J, Kurtz SM. Montell 1900 degrades faster than GUR 1050 during accelerated aging after gamma irradiation in air. In: Proc 27th Soc Biomater Annu Meet; 2001. p 81.
    • (2001) Proc 27th Soc Biomater Annu Meet , pp. 81
    • Edidin, A.A.1    Muth, J.2    Kurtz, S.M.3
  • 26
    • 2142662263 scopus 로고    scopus 로고
    • Standard test method for determining J-R curves of plastic materials
    • Philadelphia: American Society for Testing and Materials
    • ASTM Specification D 6068-96. Standard test method for determining J-R curves of plastic materials. In: Annual book of ASTM standards. Philadelphia: American Society for Testing and Materials; 1996. pp 760-766.
    • (1996) Annual book of ASTM standards , pp. 760-766
  • 27
    • 0003901380 scopus 로고
    • Standard test method for measurement of fatigue crack growth rates
    • Philadelphia: American Society for Testing and Materials
    • ASTM Specification E 647-95. Standard test method for measurement of fatigue crack growth rates. In: Annual book of ASTM standards. Philadelphia: American Society for Testing and Materials; 1995. pp 578-614.
    • (1995) Annual book of ASTM standards , pp. 578-614
  • 28
    • 85014447649 scopus 로고
    • A critical analysis of crack propagation laws
    • Paris PC, Erdogen F. A critical analysis of crack propagation laws. J Basic Eng 1960;85:528-534.
    • (1960) J Basic Eng , vol.85 , pp. 528-534
    • Paris, P.C.1    Erdogen, F.2
  • 29
    • 2142807429 scopus 로고    scopus 로고
    • Standard test method for J-integral characterization of fracture toughness
    • Philadelphia: American Society for Testing and Materials
    • ASTM Specification E 1737-96. Standard test method for J-integral characterization of fracture toughness. In: Annual book of ASTM standards. Philadelphia: American Society for Testing and Materials, 1999. p 971.
    • (1999) Annual book of ASTM standards , pp. 971
  • 30
    • 0006936144 scopus 로고    scopus 로고
    • Standard test method for measurement of fracture toughness
    • Philadelphia: American Society for Testing and Materials
    • ASTM Specification E 1820-99. Standard test method for measurement of fracture toughness. In: Annual book of ASTM standards. Philadelphia: American Society for Testing and Materials; 1999. pp 972-997.
    • (1999) Annual book of ASTM standards , pp. 972-997
  • 31
    • 0024136773 scopus 로고
    • J integral measurements of ultra high molecular weight polyethylene
    • Rimnac CM, Wright TM, Klein RW. J integral measurements of ultra high molecular weight polyethylene. Polymer Eng Sci 1988;28:1586-15891988.
    • (1988) Polymer Eng Sci , vol.28 , pp. 1586-15891988
    • Rimnac, C.M.1    Wright, T.M.2    Klein, R.W.3
  • 32
    • 0030832380 scopus 로고    scopus 로고
    • Critical assessment of methods for evaluating J-integral for medical grade ultra high molecular weight polyethylene
    • Pascaud RS, Evans WT, McCullagh PJJ, Fitzpatrick D. Critical assessment of methods for evaluating J-integral for medical grade ultra high molecular weight polyethylene. Polymer Eng Sci 1997;37:11-18.
    • (1997) Polymer Eng Sci , vol.37 , pp. 11-18
    • Pascaud, R.S.1    Evans, W.T.2    McCullagh, P.J.J.3    Fitzpatrick, D.4
  • 33
    • 0003382294 scopus 로고
    • Ic, a measure of fracture toughness
    • Philadelphia: American Society for Testing and Materials
    • Ic, a measure of fracture toughness. In: Annual book of ASTM standards. Philadelphia: American Society for Testing and Materials; 1989. pp 646-655.
    • (1989) Annual book of ASTM standards , pp. 646-655
  • 35
    • 0033179629 scopus 로고    scopus 로고
    • Radiation and peroxide crosslinking promote strain hardening behavior and molecular alignment in UHMWPE during multiaxial loading conditions
    • Kurtz SM, Pruitt LA, Jewett CW, Foulds JR, Edidin AA. Radiation and peroxide crosslinking promote strain hardening behavior and molecular alignment in UHMWPE during multiaxial loading conditions. Biomaterials 1999;20:1449-1462.
    • (1999) Biomaterials , vol.20 , pp. 1449-1462
    • Kurtz, S.M.1    Pruitt, L.A.2    Jewett, C.W.3    Foulds, J.R.4    Edidin, A.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.