메뉴 건너뛰기




Volumn 24, Issue 1, 2009, Pages 158.e15-158.e19

Fracture of a Cross-Linked Polyethylene Liner Due to Impingement

Author keywords

early failure; fatigue failure; highly cross linked polyethylene; impingement; total hip arthroplasty

Indexed keywords

POLYETHYLENE; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE;

EID: 57649097317     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2007.12.020     Document Type: Article
Times cited : (71)

References (10)
  • 1
    • 1642499198 scopus 로고    scopus 로고
    • Surface analysis of early retrieved acetabular polyethylene liners: a comparison of standard and highly crosslinked polyethylenes
    • Muratoglu O.K., Greenbaum E., Bragdon C., et al. Surface analysis of early retrieved acetabular polyethylene liners: a comparison of standard and highly crosslinked polyethylenes. J Arthroplasty 19 (2004) 68
    • (2004) J Arthroplasty , vol.19 , pp. 68
    • Muratoglu, O.K.1    Greenbaum, E.2    Bragdon, C.3
  • 2
    • 0032927112 scopus 로고    scopus 로고
    • Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements
    • McKellop H., Shen F.-W., Lu B., et al. Development of an extremely wear resistant ultra-high molecular weight polyethylene for total hip replacements. J Orthop Res 17 (1999) 157
    • (1999) J Orthop Res , vol.17 , pp. 157
    • McKellop, H.1    Shen, F.-W.2    Lu, B.3
  • 3
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking polyethylene to improve wear, reduce oxidation, and retain mechanical properties
    • Muratoglu O., Bragdon D., O'Connor D.O., et al. A novel method of cross-linking polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 16 (2001) 149
    • (2001) J Arthroplasty , vol.16 , pp. 149
    • Muratoglu, O.1    Bragdon, D.2    O'Connor, D.O.3
  • 4
    • 0347596747 scopus 로고    scopus 로고
    • Assessment of wear in extensively irradiated UHMWPE cups in simulator studies
    • Oonishi H., Clarke I.C., Yamamoto K., et al. Assessment of wear in extensively irradiated UHMWPE cups in simulator studies. J Biomed Mater Res A (2004) 68
    • (2004) J Biomed Mater Res A , pp. 68
    • Oonishi, H.1    Clarke, I.C.2    Yamamoto, K.3
  • 5
    • 1842473877 scopus 로고    scopus 로고
    • Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head
    • Halley D., Glassman A., and Crowninshield R. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head. J Bone Joint Surg 86A (2004) 827
    • (2004) J Bone Joint Surg , vol.86 A , pp. 827
    • Halley, D.1    Glassman, A.2    Crowninshield, R.3
  • 7
    • 26444509444 scopus 로고    scopus 로고
    • Cracking and impingement in ultra-high molecular weight polyethylene acetabular liners
    • Birman M., Noble P., Conditt M., Li S., et al. Cracking and impingement in ultra-high molecular weight polyethylene acetabular liners. J Arthroplasty 20 (2005) 87
    • (2005) J Arthroplasty , vol.20 , pp. 87
    • Birman, M.1    Noble, P.2    Conditt, M.3    Li, S.4
  • 8
    • 30344488765 scopus 로고    scopus 로고
    • Long-term survival of the acetabular component after total hip arthroplasty with cement in patients with developmental dysplasia of the hip
    • Chougle A., Hemmady M., and Hodgkinson J. Long-term survival of the acetabular component after total hip arthroplasty with cement in patients with developmental dysplasia of the hip. J Bone Joint Surg 88 (2006) 71
    • (2006) J Bone Joint Surg , vol.88 , pp. 71
    • Chougle, A.1    Hemmady, M.2    Hodgkinson, J.3
  • 9
    • 20444362419 scopus 로고    scopus 로고
    • Acetabular revision with a 7-mm lateral offset component inserted without cement in patients who have acetabular deficiency
    • McGrory B. Acetabular revision with a 7-mm lateral offset component inserted without cement in patients who have acetabular deficiency. J Arthroplasty 20 (2005) 445
    • (2005) J Arthroplasty , vol.20 , pp. 445
    • McGrory, B.1
  • 10
    • 0035885561 scopus 로고    scopus 로고
    • Identification and quantification of radiation in UHMWPE through trans-vinylene yield
    • Muratoglu O., and Harris W. Identification and quantification of radiation in UHMWPE through trans-vinylene yield. J Biomed Mater Res 56 (2001) 584
    • (2001) J Biomed Mater Res , vol.56 , pp. 584
    • Muratoglu, O.1    Harris, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.