Dealing with matrix effect: Should there be a cut-off limit for signal ion suppression in quantitative assay validation?

Author keywords

[No Author keywords available]

Indexed keywords

ION SUPPRESSION; MATRICES EFFECT; QUANTITATIVE ASSAY;

EID: 79955766010     PISSN: 02693879     EISSN: 10990801     Source Type: Journal    
DOI: 10.1002/bmc.1637     Document Type: Letter
Times cited : (6)

References (13)
  • 2
    • 0142195729 scopus 로고    scopus 로고
    • Matrix effect in bio-analysis of illicit drugs with LC- MS/MS: influence of ionization type, sample preparation, and biofluid
    • Dams R, Huestis MA, Lambert WE and Murphy CM. Matrix effect in bio-analysis of illicit drugs with LC- MS/MS: influence of ionization type, sample preparation, and biofluid. Journal of American Society of Mass Spectrometry 2003; 14: 1290-1294.
    • (2003) Journal of American Society of Mass Spectrometry , vol.14 , pp. 1290-1294
    • Dams, R.1    Huestis, M.A.2    Lambert, W.E.3    Murphy, C.M.4
  • 3
    • 67649660175 scopus 로고    scopus 로고
    • Determination of a hydrophilic paclitaxel derivative, 7-xylosyl-10-deacetylpaclitaxel in rat plasma by LC-MS/MS
    • Jiang GS, Zu YG, Zhang L, Fu YJ, Zhang Y, Wang Z, Hua X and Wang JT. Determination of a hydrophilic paclitaxel derivative, 7-xylosyl-10-deacetylpaclitaxel in rat plasma by LC-MS/MS. Biomedical Chromatography 2009; 23: 472-479.
    • (2009) Biomedical Chromatography , vol.23 , pp. 472-479
    • Jiang, G.S.1    Zu, Y.G.2    Zhang, L.3    Fu, Y.J.4    Zhang, Y.5    Wang, Z.6    Hua, X.7    Wang, J.T.8
  • 4
    • 46949097546 scopus 로고    scopus 로고
    • Development and validation of a sensitive LC- MS/MS method with electrospray ionization for quantitation of rhein in human plasma: application to a pharmacokinetic study
    • Layek B, Kumar TS, Trivedi RK, Mullangi R and Srinivas NR. Development and validation of a sensitive LC- MS/MS method with electrospray ionization for quantitation of rhein in human plasma: application to a pharmacokinetic study. Biomedical Chromatography 2008; 22: 616-624.
    • (2008) Biomedical Chromatography , vol.22 , pp. 616-624
    • Layek, B.1    Kumar, T.S.2    Trivedi, R.K.3    Mullangi, R.4    Srinivas, N.R.5
  • 5
    • 26444546402 scopus 로고    scopus 로고
    • Simultaneous determination of norethindrone and ethinyl estradiol in human plasma by high performance liquid chromatography with tandem mass spectrometry - experiences on developing a highly selective method using derivatization reagent for enhancing sensitivity
    • Li W, Li YH, Li AC, Zhou SL and Naidong W. Simultaneous determination of norethindrone and ethinyl estradiol in human plasma by high performance liquid chromatography with tandem mass spectrometry - experiences on developing a highly selective method using derivatization reagent for enhancing sensitivity. Journal of Chromatography B 2005; 825: 223-232.
    • (2005) Journal of Chromatography B , vol.825 , pp. 223-232
    • Li, W.1    Li, Y.H.2    Li, A.C.3    Zhou, S.L.4    Naidong, W.5
  • 6
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    • Matuszewski BK, Constanzer ML and Chavez-Eng CM. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anaytical Chemistry 2003; 75: 3019-3030.
    • (2003) Anaytical Chemistry , vol.75 , pp. 3019-3030
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 7
    • 65249123231 scopus 로고    scopus 로고
    • Simultaneous quantification of a non-nucleoside reverse transcriptase inhibitor efavirenz, a nucleoside reverse transcriptase inhibitor emtricitabine and a nucleotide reverse transcriptase inhibitor tenofovir in plasma by liquid chromatography positive ion electrospray tandem mass spectrometry
    • Nirogi R, Bhyrapuneni G, Kandikere V, Mudigonda K, Komarneni P, Aleti R and Mukkanti K. Simultaneous quantification of a non-nucleoside reverse transcriptase inhibitor efavirenz, a nucleoside reverse transcriptase inhibitor emtricitabine and a nucleotide reverse transcriptase inhibitor tenofovir in plasma by liquid chromatography positive ion electrospray tandem mass spectrometry. Biomedical Chromatography 2009; 23: 371-381.
    • (2009) Biomedical Chromatography , vol.23 , pp. 371-381
    • Nirogi, R.1    Bhyrapuneni, G.2    Kandikere, V.3    Mudigonda, K.4    Komarneni, P.5    Aleti, R.6    Mukkanti, K.7
  • 8
    • 67649656077 scopus 로고    scopus 로고
    • Dodging matrix effects in liquid chromatography tandem mass spectrometric assays - compilation of key learnings and perspectives
    • Srinivas NR. Dodging matrix effects in liquid chromatography tandem mass spectrometric assays - compilation of key learnings and perspectives. Biomedical Chromatography 2009; 23: 451-454.
    • (2009) Biomedical Chromatography , vol.23 , pp. 451-454
    • Srinivas, N.R.1
  • 9
    • 41549097828 scopus 로고    scopus 로고
    • Development and validation of a sensitive LC-MS/MS method with electrospray ionization using multiple ions for quantitation of torcetrapib in hamster and dog plasma
    • Trivedi RK, Dubey PK, Mullangi R and Srinivas NR.Development and validation of a sensitive LC-MS/MS method with electrospray ionization using multiple ions for quantitation of torcetrapib in hamster and dog plasma. Biomedical Chromatography 2008; 22: 316-326.
    • (2008) Biomedical Chromatography , vol.22 , pp. 316-326
    • Trivedi, R.K.1    Dubey, P.K.2    Mullangi, R.3    Srinivas, N.R.4
  • 10
    • 48349127216 scopus 로고    scopus 로고
    • Simultaneous determination of beta-blockers in human plasma using liquid chromatography-tandem mass spectrometry
    • Umezawa H, Lee XP, Arima Y, Hasegawa C, Izawa H, Kumazawa T and Sato K. Simultaneous determination of beta-blockers in human plasma using liquid chromatography-tandem mass spectrometry. Biomedical Chromatography 2008; 22: 702-711.
    • (2008) Biomedical Chromatography , vol.22 , pp. 702-711
    • Umezawa, H.1    Lee, X.P.2    Arima, Y.3    Hasegawa, C.4    Izawa, H.5    Kumazawa, T.6    Sato, K.7
  • 11
    • 65249159149 scopus 로고    scopus 로고
    • Highly sensitive method for the determination of omeprazole in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study
    • Vittal S, Ganneboina R, Layek B, Trivedi RK, Hotha KK, Bharathi DV and Mullangi R. Highly sensitive method for the determination of omeprazole in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry: application to a clinical pharmacokinetic study. Biomedical Chromatography 2009; 23: 390-396.
    • (2009) Biomedical Chromatography , vol.23 , pp. 390-396
    • Vittal, S.1    Ganneboina, R.2    Layek, B.3    Trivedi, R.K.4    Hotha, K.K.5    Bharathi, D.V.6    Mullangi, R.7
  • 12
    • 74849112110 scopus 로고    scopus 로고
    • Simultaneous assay of sildenafil and desmethylsildenafil in neonatal plasma by ultra-performance liquid chromatography-tandem mass spectrometry
    • Witjes BC, Ahsman MJ, van der Nagel BC, Tibboel D and Mathot RA. Simultaneous assay of sildenafil and desmethylsildenafil in neonatal plasma by ultra-performance liquid chromatography-tandem mass spectrometry. Biomedical Chromatography 2010; 24: 180-185.
    • (2010) Biomedical Chromatography , vol.24 , pp. 180-185
    • Witjes, B.C.1    Ahsman, M.J.2    van der Nagel, B.C.3    Tibboel, D.4    Mathot, R.A.5
  • 13
    • 74849084662 scopus 로고    scopus 로고
    • Development and validation of UPLC-MS/MS method for simutaneous determination of gestodene and ethinyl estradiol in rat plasma
    • Xiong Z, Sun X, Huo T, Li N, Zheng Y and Sun Y. Development and validation of UPLC-MS/MS method for simutaneous determination of gestodene and ethinyl estradiol in rat plasma. Biomedical Chromatography 2010; 24: 160-168.
    • (2010) Biomedical Chromatography , vol.24 , pp. 160-168
    • Xiong, Z.1    Sun, X.2    Huo, T.3    Li, N.4    Zheng, Y.5    Sun, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.