Volumn 35, Issue 10, 2009, Pages 1801-1808

Tracking changes in cardiac output: Methodological considerations for the validation of monitoring devices

Author keywords

Cardiac output; Cardiovascular monitoring; Haemodynamics; Methodology

Indexed keywords

CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; HEART OUTPUT; HUMAN; INFORMATION PROCESSING; RANDOM ERROR; RANDOMIZED CONTROLLED TRIAL; RESPONSE TIME; REVIEW; VALIDATION PROCESS;

EID: 72449201516     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-009-1570-9     Document Type: Review
Times cited : (104)

References (42)
  • 1
    • 34447131664 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitoring (NICOM): A clinical validation
    • DOI 10.1007/s00134-007-0640-0
    • P Squara D Denjean P Estagnasie A Brusset JC Dib C Dubois 2007 Noninvasive cardiac output monitoring (NICOM): a clinical validation Intensive Care Med 33 1191 1194 17458538 10.1007/s00134-007-0640-0 (Pubitemid 47036882)
    • (2007) Intensive Care Medicine , vol.33 , Issue.7 , pp. 1191-1194
    • Squara, P.1    Denjean, D.2    Estagnasie, P.3    Brusset, A.4    Dib, J.C.5    Dubois, C.6
  • 2
    • 34547134966 scopus 로고    scopus 로고
    • An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
    • 17635422 10.1111/j.1365-2044.2007.05135.x
    • RB de Wilde JJ Schreuder PC van den Berg JR Jansen 2007 An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery Anaesthesia 62 760 768 17635422 10.1111/j.1365-2044.2007.05135.x
    • (2007) Anaesthesia , vol.62 , pp. 760-768
    • De Wilde, R.B.1    Schreuder, J.J.2    Van Den Berg, P.C.3    Jansen, J.R.4
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 2868172 1:STN:280:DyaL287hslWqsQ%3D%3D
    • JM Bland DG Altman 1986 Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 307 310 2868172 1:STN:280:DyaL287hslWqsQ%3D%3D
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 34249000391 scopus 로고    scopus 로고
    • Methodologies for assessing agreement between two methods of clinical measurement: Are we as good as we think we are?
    • DOI 10.1097/MCC.0b013e328149af80, PII 0007519820070600000009
    • M Cecconi M Grounds A Rhodes 2007 Methodologies for assessing agreement between two methods of clinical measurement: are we as good as we think we are? Curr Opin Crit Care 13 294 296 17468561 10.1097/MCC.0b013e328149af80 (Pubitemid 46789345)
    • (2007) Current Opinion in Critical Care , vol.13 , Issue.3 , pp. 294-296
    • Cecconi, M.1    Grounds, M.2    Rhodes, A.3
  • 7
    • 5644244930 scopus 로고    scopus 로고
    • 2 rebreathing
    • DOI 10.1053/j.jvca.2004.07.005, PII S1053077004001557
    • M Botero D Kirby EB Lobato ED Staples N Gravenstein 2004 Measurement of cardiac output before and after cardiopulmonary bypass: Comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing J Cardiothorac Vasc Anesth 18 563 572 15578466 10.1053/j.jvca.2004.07.005 (Pubitemid 39369954)
    • (2004) Journal of Cardiothoracic and Vascular Anesthesia , vol.18 , Issue.5 , pp. 563-572
    • Botero, M.1    Kirby, D.2    Lobato, E.B.3    Staples, E.D.4    Gravenstein, N.5
  • 8
    • 34547132055 scopus 로고    scopus 로고
    • Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance
    • 17384132 10.1152/ajpheart.00195.2007 1:CAS:528:DC%2BD2sXovVyhsLg%3D
    • H Keren D Burkhoff P Squara 2007 Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance Am J Physiol Heart Circ Physiol 293 H583 H589 17384132 10.1152/ajpheart.00195.2007 1:CAS:528:DC%2BD2sXovVyhsLg%3D
    • (2007) Am J Physiol Heart Circ Physiol , vol.293
    • Keren, H.1    Burkhoff, D.2    Squara, P.3
  • 9
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • 6758640 1:STN:280:DyaL3s%2FpvVKgug%3D%3D
    • CW Stetz RG Miller GE Kelly TA Raffin 1982 Reliability of the thermodilution method in the determination of cardiac output in clinical practice Am Rev Respir Dis 126 1001 1004 6758640 1:STN:280: DyaL3s%2FpvVKgug%3D%3D
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 10
    • 0022401426 scopus 로고
    • Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output
    • DOI 10.1016/0002-9149(85)91132-4
    • LD Hillis BG Firth MD Winniford 1985 Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output Am J Cardiol 56 764 768 3904383 10.1016/0002-9149(85)91132-4 1:STN:280: DyaL28%2FkslGmtw%3D%3D (Pubitemid 16173063)
    • (1985) American Journal of Cardiology , vol.56 , Issue.12 , pp. 764-768
    • Hillis, L.D.1    Firth, B.G.2    Winniford, M.D.3
  • 11
    • 0028965860 scopus 로고
    • Cardiac output measurement by the thermodilution method: An in vitro test of accuracy of three commercially available automatic cardiac output computers
    • 7775697 10.1007/BF01726539 1:STN:280:DyaK2M3psVaqsg%3D%3D
    • A Rubini D Del Monte V Catena I Attar M Cesaro D Soranzo G Rattazzi GL Alati 1995 Cardiac output measurement by the thermodilution method: an in vitro test of accuracy of three commercially available automatic cardiac output computers Intensive Care Med 21 154 158 7775697 10.1007/BF01726539 1:STN:280:DyaK2M3psVaqsg%3D%3D
    • (1995) Intensive Care Med , vol.21 , pp. 154-158
    • Rubini, A.1    Del Monte, D.2    Catena, V.3    Attar, I.4    Cesaro, M.5    Soranzo, D.6    Rattazzi, G.7    Alati, G.L.8
  • 12
    • 0028246778 scopus 로고
    • Effects of dobutamine on oxygen consumption in septic patients. Direct versus indirect determinations
    • 8025780
    • D De Backer JJ Moraine J Berre RJ Kahn JL Vincent 1994 Effects of dobutamine on oxygen consumption in septic patients. Direct versus indirect determinations Am J Respir Crit Care Med 150 95 100 8025780
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 95-100
    • De Backer, D.1    Moraine, J.J.2    Berre, J.3    Kahn, R.J.4    Vincent, J.L.5
  • 13
    • 33746761661 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis
    • DOI 10.1152/japplphysiol.01488.2005
    • Z Lu R Mukkamala 2006 Continuous cardiac output monitoring in humans by invasive and noninvasive peripheral blood pressure waveform analysis J Appl Physiol 101 598 608 16849813 10.1152/japplphysiol.01488.2005 (Pubitemid 44162371)
    • (2006) Journal of Applied Physiology , vol.101 , Issue.2 , pp. 598-608
    • Lu, Z.1    Mukkamala, R.2
  • 14
    • 60449102439 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurement in the critically ill patient: Determination of precision of the technique
    • 18802681 10.1007/s00134-008-1292-4 1:CAS:528:DC%2BD1MXhvV2jsL4%3D
    • M Cecconi D Dawson R Grounds A Rhodes 2009 Lithium dilution cardiac output measurement in the critically ill patient: determination of precision of the technique Intensive Care med 35 498 504 18802681 10.1007/s00134-008-1292-4 1:CAS:528:DC%2BD1MXhvV2jsL4%3D
    • (2009) Intensive Care Med , vol.35 , pp. 498-504
    • Cecconi, M.1    Dawson, D.2    Grounds, R.3    Rhodes, A.4
  • 15
    • 0029016594 scopus 로고
    • Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: A prospective criterion standard study
    • 7736744 10.1097/00003246-199505000-00014 1:STN:280:DyaK2M3lsVygsw%3D%3D
    • M Haller C Zollner J Briegel H Forst 1995 Evaluation of a new continuous thermodilution cardiac output monitor in critically ill patients: a prospective criterion standard study Crit Care Med 23 860 866 7736744 10.1097/00003246- 199505000-00014 1:STN:280:DyaK2M3lsVygsw%3D%3D
    • (1995) Crit Care Med , vol.23 , pp. 860-866
    • Haller, M.1    Zollner, C.2    Briegel, J.3    Forst, H.4
  • 16
    • 0030249057 scopus 로고    scopus 로고
    • Reproducibility of thermodilution cardiac output determination in critically ill patients: Comparison between bolus and continuous method
    • 8934344 10.1007/BF02077635 1:STN:280:DyaK2s%2FovVCjtA%3D%3D
    • Y Le Tulzo M Belghith P Seguin J Dall'Ava M Monchi R Thomas JF Dhainaut 1996 Reproducibility of thermodilution cardiac output determination in critically ill patients: comparison between bolus and continuous method J Clin Monit 12 379 385 8934344 10.1007/BF02077635 1:STN:280:DyaK2s%2FovVCjtA%3D%3D
    • (1996) J Clin Monit , vol.12 , pp. 379-385
    • Le Tulzo, Y.1    Belghith, M.2    Seguin, P.3    Dall'Ava, J.4    Monchi, M.5    Thomas, R.6    Dhainaut, J.F.7
  • 17
    • 0035569245 scopus 로고    scopus 로고
    • Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination
    • 11744592 10.1007/BF03020382 1:STN:280:DC%2BD3MnpslyktA%3D%3D
    • C Zollner AE Goetz M Weis K Morstedt B Pichler P Lamm E Kilger M Haller 2001 Continuous cardiac output measurements do not agree with conventional bolus thermodilution cardiac output determination Can J Anaesth 48 1143 1147 11744592 10.1007/BF03020382 1:STN:280:DC%2BD3MnpslyktA%3D%3D
    • (2001) Can J Anaesth , vol.48 , pp. 1143-1147
    • Zollner, C.1    Goetz, A.E.2    Weis, M.3    Morstedt, K.4    Pichler, B.5    Lamm, P.6    Kilger, E.7    Haller, M.8
  • 18
    • 33646870345 scopus 로고    scopus 로고
    • Continuous cardiac output monitoring after cardiopulmonary bypass: A comparison with bolus thermodilution measurement
    • DOI 10.1007/s00134-006-0161-2
    • K Bendjelid N Schutz PM Suter JA Romand 2006 Continuous cardiac output monitoring after cardiopulmonary bypass: a comparison with bolus thermodilution measurement Intensive Care Med 32 919 922 16601960 10.1007/s00134-006-0161-2 (Pubitemid 43781377)
    • (2006) Intensive Care Medicine , vol.32 , Issue.6 , pp. 919-922
    • Bendjelid, K.1    Schutz, N.2    Suter, P.M.3    Romand, J.-A.4
  • 19
    • 0035213467 scopus 로고    scopus 로고
    • Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma
    • 11706330 10.1097/00005373-200111000-00005 1:STN:280: DC%2BD3MnnslKmsA%3D%3D
    • RA Maxwell JB Gibson JB Slade TC Fabian KG Proctor 2001 Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma J Trauma 51 849 853 11706330 10.1097/00005373-200111000-00005 1:STN:280: DC%2BD3MnnslKmsA%3D%3D
    • (2001) J Trauma , vol.51 , pp. 849-853
    • Maxwell, R.A.1    Gibson, J.B.2    Slade, J.B.3    Fabian, T.C.4    Proctor, K.G.5
  • 20
    • 0142149221 scopus 로고    scopus 로고
    • Cardiac output monitoring: Aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation
    • 12944446 10.1007/BF03018714
    • G Della Rocca MG Costa C Coccia L Pompei P Di Marco V Vilardi P Pietropaoli 2003 Cardiac output monitoring: aortic transpulmonary thermodilution and pulse contour analysis agree with standard thermodilution methods in patients undergoing lung transplantation Can J Anaesth 50 707 711 12944446 10.1007/BF03018714
    • (2003) Can J Anaesth , vol.50 , pp. 707-711
    • Della Rocca, G.1    Costa, M.G.2    Coccia, C.3    Pompei, L.4    Di Marco, P.5    Vilardi, V.6    Pietropaoli, P.7
  • 21
    • 0042344943 scopus 로고    scopus 로고
    • 2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery
    • DOI 10.1097/00000542-200308000-00009
    • Y Kotake K Moriyama Y Innami H Shimizu T Ueda H Morisaki J Takeda 2003 Performance of noninvasive partial CO2 rebreathing cardiac output and continuous thermodilution cardiac output in patients undergoing aortic reconstruction surgery Anesthesiology 99 283 288 12883400 10.1097/00000542-200308000-00009 (Pubitemid 36909553)
    • (2003) Anesthesiology , vol.99 , Issue.2 , pp. 283-288
    • Kotake, Y.1    Moriyama, K.2    Innami, Y.3    Shimizu, H.4    Ueda, T.5    Morisaki, H.6    Takeda, J.7
  • 22
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • 7988126 1:STN:280:DyaK2M%2FnvFOguw%3D%3D
    • J Boldt T Menges M Wollbruck H Hammermann G Hempelmann 1994 Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? Crit Care Med 22 1913 1918 7988126 1:STN:280:DyaK2M%2FnvFOguw%3D%3D
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbruck, M.3    Hammermann, H.4    Hempelmann, G.5
  • 23
    • 0030902626 scopus 로고    scopus 로고
    • Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients
    • DOI 10.1097/00003246-199703000-00003
    • SA Burchell M Yu SA Takiguchi RM Ohta SA Myers 1997 Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients Crit Care Med 25 388 391 9118651 10.1097/00003246-199703000-00003 1:STN:280:DyaK2s3kvFWhuw%3D%3D (Pubitemid 27152729)
    • (1997) Critical Care Medicine , vol.25 , Issue.3 , pp. 388-391
    • Burchell, S.A.1    Yu, M.2    Takiguchi, S.A.3    Ohta, R.M.4    Myers, S.A.5
  • 24
    • 0033766369 scopus 로고    scopus 로고
    • Effects of body temperature on accuracy of continuous cardiac output measurements
    • 10933110 10.1080/08941930050075838 1:STN:280:DC%2BD3M%2FkvVCruw%3D%3D
    • FA Luchette D Porembka K Davis Jr RD Branson L James JM Hurst JA Johannigman RS Campbell 2000 Effects of body temperature on accuracy of continuous cardiac output measurements J Invest Surg 13 147 152 10933110 10.1080/08941930050075838 1:STN:280:DC%2BD3M%2FkvVCruw%3D%3D
    • (2000) J Invest Surg , vol.13 , pp. 147-152
    • Luchette, F.A.1    Porembka, D.2    Davis Jr, K.3    Branson, R.D.4    James, L.5    Hurst, J.M.6    Johannigman, J.A.7    Campbell, R.S.8
  • 25
    • 0031928196 scopus 로고    scopus 로고
    • A multicenter evaluation of a new continuous cardiac output pulmonary artery catheter system
    • 9710092 10.1097/00003246-199808000-00018 1:STN:280:DyaK1czntlyltA%3D%3D
    • FG Mihm A Gettinger CW Hanson 3rd HC Gilbert EP Stover JS Vender B Beerle G Haddow 1998 A multicenter evaluation of a new continuous cardiac output pulmonary artery catheter system Crit Care Med 26 1346 1350 9710092 10.1097/00003246-199808000-00018 1:STN:280:DyaK1czntlyltA%3D%3D
    • (1998) Crit Care Med , vol.26 , pp. 1346-1350
    • Mihm, F.G.1    Gettinger, A.2    Hanson III, C.W.3    Gilbert, H.C.4    Stover, E.P.5    Vender, J.S.6    Beerle, B.7    Haddow, G.8
  • 26
    • 0032429807 scopus 로고    scopus 로고
    • Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors
    • DOI 10.1016/S0883-9441(98)90004-1
    • DL Medin DT Brown R Wesley RE Cunnion FP Ognibene 1998 Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors J Crit Care 13 184 189 9869545 10.1016/S0883-9441(98)90004-1 1:STN:280:DyaK1M%2FosVyqsg%3D%3D (Pubitemid 29015274)
    • (1998) Journal of Critical Care , vol.13 , Issue.4 , pp. 184-189
    • Medin, D.L.1    Brown, D.T.2    Wesley, R.3    Cunnion, R.E.4    Ognibene, F.P.5
  • 27
    • 0036042186 scopus 로고    scopus 로고
    • Comparison of continuous thermodilution and bolus cardiac output measurements in septic shock
    • DOI 10.1007/s00134-002-1415-2
    • Q Sun P Rogiers D Pauwels JL Vincent 2002 Comparison of continuous thermodilution and bolus cardiac output measurements in septic shock Intensive Care Med 28 1276 1280 12209277 10.1007/s00134-002-1415-2 (Pubitemid 35025046)
    • (2002) Intensive Care Medicine , vol.28 , Issue.9 , pp. 1276-1280
    • Sun, Q.1    Rogiers, P.2    Pauwels, D.3    Vincent, J.-L.4
  • 28
    • 0036744725 scopus 로고    scopus 로고
    • Cardiac output measurement during cardiac surgery: Esophageal Doppler versus pulmonary artery catheter
    • 12434609
    • NY Su CJ Huang P Tsai YW Hsu YC Hung CR Cheng 2002 Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheter Acta Anaesthesiol Sin 40 127 133 12434609
    • (2002) Acta Anaesthesiol Sin , vol.40 , pp. 127-133
    • Su, N.Y.1    Huang, C.J.2    Tsai, P.3    Hsu, Y.W.4    Hung, Y.C.5    Cheng, C.R.6
  • 29
    • 11144335979 scopus 로고    scopus 로고
    • The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults
    • DOI 10.1007/s00134-004-2430-2
    • PM Dark M Singer 2004 The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults Intensive Care Med 30 2060 2066 15368037 10.1007/s00134-004-2430-2 (Pubitemid 40022322)
    • (2004) Intensive Care Medicine , vol.30 , Issue.11 , pp. 2060-2066
    • Dark, P.M.1    Singer, M.2
  • 30
    • 0344394235 scopus 로고    scopus 로고
    • Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature
    • Chew M, Poelaert J (2003) Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature. Intensive Care Med 1889-1894
    • (2003) Intensive Care Med , pp. 1889-1894
    • Chew, M.1    Poelaert, J.2
  • 31
    • 34547699294 scopus 로고    scopus 로고
    • Validation of a new arterial pulse contour-based cardiac output device
    • DOI 10.1097/01.CCM.0000275429.45312.8C, PII 0000324620070800000014
    • EE de Waal CJ Kalkman S Rex WF Buhre 2007 Validation of a new arterial pulse contour-based cardiac output device Crit Care Med 35 1904 1909 17581493 10.1097/01.CCM.0000275429.45312.8C (Pubitemid 47220365)
    • (2007) Critical Care Medicine , vol.35 , Issue.8 , pp. 1904-1909
    • De Waal, E.E.C.1    Kalkman, C.J.2    Rex, S.3    Buhre, W.F.4
  • 32
    • 59649127189 scopus 로고    scopus 로고
    • Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: Validation of a novel method
    • 19050622 10.1097/CCM.0b013e31819290d5
    • S Friesecke A Heinrich P Abel S Felix 2009 Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: validation of a novel method Crit Care Med 37 119 123 19050622 10.1097/CCM.0b013e31819290d5
    • (2009) Crit Care Med , vol.37 , pp. 119-123
    • Friesecke, S.1    Heinrich, A.2    Abel, P.3    Felix, S.4
  • 33
    • 0036247803 scopus 로고    scopus 로고
    • Comparison of continuous, stat, and intermittent cardiac output measurements in patients undergoing minimally invasive direct coronary artery bypass surgery
    • DOI 10.1053/jcan.2002.31063
    • A Singh R Juneja Y Mehta N Trehan 2002 Comparison of continuous, stat, and intermittent cardiac output measurements in patients undergoing minimally invasive direct coronary artery bypass surgery J Cardiothorac Vasc Anesth 16 186 190 11957168 10.1053/jcan.2002.31063 (Pubitemid 34493747)
    • (2002) Journal of Cardiothoracic and Vascular Anesthesia , vol.16 , Issue.2 , pp. 186-190
    • Singh, A.1    Juneja, R.2    Mehta, Y.3    Trehan, N.4
  • 34
    • 0019641003 scopus 로고
    • Thermal dependence of endurance and locomotory energetics in a lizard
    • 7304779 1:STN:280:DyaL38%2FmsFOrsg%3D%3D
    • H John-Alder A Bennet 1981 Thermal dependence of endurance and locomotory energetics in a lizard Am J Physiol 241 R342 R349 7304779 1:STN:280: DyaL38%2FmsFOrsg%3D%3D
    • (1981) Am J Physiol , vol.241
    • John-Alder, H.1    Bennet, A.2
  • 35
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • LA Critchley JA Critchley 1999 A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 85 91 12578081 10.1023/A:1009982611386 1:STN:280: DC%2BD3s%2FmslCruw%3D%3D (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 36
    • 12944322237 scopus 로고    scopus 로고
    • Matching total body oxygen consumption and delivery: A crucial objective?
    • DOI 10.1007/s00134-004-2449-4
    • P Squara 2004 Matching total body oxygen consumption and delivery: a crucial objective? Intensive Care Med 30 2170 2179 15448891 10.1007/s00134-004- 2449-4 (Pubitemid 40174252)
    • (2004) Intensive Care Medicine , vol.30 , Issue.12 , pp. 2170-2179
    • Squara, P.1
  • 38
    • 0038293048 scopus 로고    scopus 로고
    • A Computer Program for Interpreting Pulmonary Artery Catheterization Data: Results of the European HEMODYN Resident Study
    • 12655395
    • P Squara E Fourquet L Jacquet A Broccard T Uhlig A Rhodes J Bakker C Perret 2003 A Computer Program for Interpreting Pulmonary Artery Catheterization Data: Results of the European HEMODYN Resident Study Intensive Care Med 29 735 741 12655395
    • (2003) Intensive Care Med , vol.29 , pp. 735-741
    • Squara, P.1    Fourquet, E.2    Jacquet, L.3    Broccard, A.4    Uhlig, T.5    Rhodes, A.6    Bakker, J.7    Perret, C.8
  • 40
    • 0029992651 scopus 로고    scopus 로고
    • Delayed time response of the continuous cardiac output pulmonary artery catheter
    • 8942581 10.1097/00000539-199612000-00007 1:STN:280:DyaK2s%2FpvVSnsg%3D%3D
    • LC Siegel MM Hennessy RG Pearl 1996 Delayed time response of the continuous cardiac output pulmonary artery catheter Anesth Analg 83 1173 1177 8942581 10.1097/00000539-199612000-00007 1:STN:280:DyaK2s%2FpvVSnsg%3D%3D
    • (1996) Anesth Analg , vol.83 , pp. 1173-1177
    • Siegel, L.C.1    Hennessy, M.M.2    Pearl, R.G.3
  • 41
    • 43349086860 scopus 로고    scopus 로고
    • Passive leg raising
    • 18214429 10.1007/s00134-008-0994-y
    • X Monnet J Teboul 2008 Passive leg raising Intensive Care Med 34 659 663 18214429 10.1007/s00134-008-0994-y
    • (2008) Intensive Care Med , vol.34 , pp. 659-663
    • Monnet, X.1    Teboul, J.2
  • 42
    • 68849121782 scopus 로고    scopus 로고
    • Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies-with specific reference to the measurement of cardiac output
    • 19183431 10.1186/cc7129
    • M Cecconi A Rhodes J Poloniecki G Della Rocca R Grounds 2009 Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies-with specific reference to the measurement of cardiac output Crit Care 13 201 19183431 10.1186/cc7129
    • (2009) Crit Care , vol.13 , pp. 201
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.