메뉴 건너뛰기




Volumn 37, Issue 5, 2011, Pages 813-826

Development of a Vessel-Mimicking Material for use in Anatomically Realistic Doppler Flow Phantoms

Author keywords

Acoustic and mechanical characterization; Anatomically realistic flow phantom; Polyvinyl alcohol cryogel; Ultrasound phantom; Vessel mimic

Indexed keywords

ANATOMICALLY REALISTIC FLOW PHANTOM; ANTIBACTERIAL AGENT; CRYOGELS; DOPPLER; FLOW EXPERIMENTS; FLOW PHANTOM; FREEZE/THAW CYCLES; HIGHER-DEGREE; IN-VIVO; MECHANICAL CHARACTERIZATIONS; SILICON CARBIDE PARTICLES; SPEED OF SOUNDS; STENOSES; ULTRASOUND PHANTOM; VESSEL MIMIC; YOUNG'S ELASTIC MODULUS;

EID: 79954453466     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2011.02.012     Document Type: Article
Times cited : (51)

References (37)
  • 1
    • 0037291276 scopus 로고    scopus 로고
    • Experimental flow studies in exact-replica phantoms of atherosclerotic carotid bifurcations under steady input conditions
    • Bale-Glickman J., Selby K., Saloner D., Savas O. Experimental flow studies in exact-replica phantoms of atherosclerotic carotid bifurcations under steady input conditions. J Biomech Eng 2003, 125:38-48.
    • (2003) J Biomech Eng , vol.125 , pp. 38-48
    • Bale-Glickman, J.1    Selby, K.2    Saloner, D.3    Savas, O.4
  • 2
    • 0038444298 scopus 로고    scopus 로고
    • Assessment of the acoustic properties of common tissue-mimicking test phantoms
    • Browne J.E., Ramnarine K.V., Watson A.J., Hoskins P.R. Assessment of the acoustic properties of common tissue-mimicking test phantoms. Ultrasound Med Biol 2003, 29:1053-1060.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 1053-1060
    • Browne, J.E.1    Ramnarine, K.V.2    Watson, A.J.3    Hoskins, P.R.4
  • 3
    • 0031021607 scopus 로고    scopus 로고
    • Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity
    • Chu K.C., Rutt B.K. Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity. Magn Reson Med 1997, 37:314-319.
    • (1997) Magn Reson Med , vol.37 , pp. 314-319
    • Chu, K.C.1    Rutt, B.K.2
  • 4
    • 78149315709 scopus 로고    scopus 로고
    • Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties
    • Cournane S., Cannon L., Browne J.E., Fagan A.J. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties. Physics Med Biol 2010, 55:5965-5983.
    • (2010) Physics Med Biol , vol.55 , pp. 5965-5983
    • Cournane, S.1    Cannon, L.2    Browne, J.E.3    Fagan, A.J.4
  • 11
    • 33947692197 scopus 로고    scopus 로고
    • Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings
    • Fromageau J., Gennisson J.L., Schmitt C., Maurice R.L., Mongrain R., Cloutier G. Estimation of polyvinyl alcohol cryogel mechanical properties with four ultrasound elastography methods and comparison with gold standard testings. IEEE Trans Ultrason Ferroelectr Freq Control 2007, 54:498-509.
    • (2007) IEEE Trans Ultrason Ferroelectr Freq Control , vol.54 , pp. 498-509
    • Fromageau, J.1    Gennisson, J.L.2    Schmitt, C.3    Maurice, R.L.4    Mongrain, R.5    Cloutier, G.6
  • 13
    • 84995499596 scopus 로고
    • Ultrasonic data acquisition and processing system for atherosclerotic tissue characterization
    • Greenleaf J.F., Duck F.A., Samayoa W.F., Johnston S.A. Ultrasonic data acquisition and processing system for atherosclerotic tissue characterization. IEEE Ultrason Symp 1974.
    • (1974) IEEE Ultrason Symp
    • Greenleaf, J.F.1    Duck, F.A.2    Samayoa, W.F.3    Johnston, S.A.4
  • 14
    • 34548817852 scopus 로고    scopus 로고
    • Physical properties of tissues relevant to arterial ultrasound imaging and blood velocity measurement
    • Hoskins P.R. Physical properties of tissues relevant to arterial ultrasound imaging and blood velocity measurement. Ultrasound Med Biol 2007, 33:1527-1539.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 1527-1539
    • Hoskins, P.R.1
  • 15
    • 42949088911 scopus 로고    scopus 로고
    • Simulation and validation of arterial ultrasound imaging and blood flow
    • Hoskins P.R. Simulation and validation of arterial ultrasound imaging and blood flow. Ultrasound Med Biol 2008, 34:693-717.
    • (2008) Ultrasound Med Biol , vol.34 , pp. 693-717
    • Hoskins, P.R.1
  • 16
    • 0024343930 scopus 로고
    • A computer controlled flow phantom for generation of physiological Doppler waveforms
    • Hoskins P.R., Anderson T., McDicken W.N. A computer controlled flow phantom for generation of physiological Doppler waveforms. Phys Med Biol 1989, 34:1709-1717.
    • (1989) Phys Med Biol , vol.34 , pp. 1709-1717
    • Hoskins, P.R.1    Anderson, T.2    McDicken, W.N.3
  • 17
    • 0038720995 scopus 로고    scopus 로고
    • International Electrotechnical Commission, G. International Electrotechnical Commission, Switzerland
    • Ultrasonics-Flow measurement systems: Flow test object 2001, International Electrotechnical Commission, G. International Electrotechnical Commission, Switzerland.
    • (2001) Ultrasonics-Flow measurement systems: Flow test object
  • 18
    • 79954555091 scopus 로고
    • IPEM. Testing of Doppler equipment
    • Report No. 70, Hoskins PR, Evans JA, Sheriff S, eds. York, UK: IPEM.
    • IPEM. Report No. 70, In: Hoskins PR, Evans JA, Sheriff S, eds. Testing of Doppler equipment. York, UK: IPEM, 1994.
    • (1994)
  • 19
    • 79954483334 scopus 로고    scopus 로고
    • ISO-7743. Rubber, vulcanized or thermoplastic-Determination of compression stress-strain properties. Sweden.
    • ISO-7743. Rubber, vulcanized or thermoplastic-Determination of compression stress-strain properties. Sweden, 2008.
    • (2008)
  • 20
    • 85047679181 scopus 로고
    • Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries
    • Kawasaki T., Sasayama S., Yagi S., Asakawa T., Hirai T. Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries. Cardiovasc Res 1987, 21:678-687.
    • (1987) Cardiovasc Res , vol.21 , pp. 678-687
    • Kawasaki, T.1    Sasayama, S.2    Yagi, S.3    Asakawa, T.4    Hirai, T.5
  • 21
    • 77953890057 scopus 로고    scopus 로고
    • Development of a range of anatomically realistic renal artery flow phantoms
    • King D.M., Ring M., Moran C.M., Browne J.E. Development of a range of anatomically realistic renal artery flow phantoms. Ultrasound Med Biol 2010, 36:1135-1144.
    • (2010) Ultrasound Med Biol , vol.36 , pp. 1135-1144
    • King, D.M.1    Ring, M.2    Moran, C.M.3    Browne, J.E.4
  • 22
    • 0024334066 scopus 로고
    • On the design and evaluation of a steady flow model for Doppler ultrasound studies
    • Law Y.F., Johnston K.W., Routh H.F., Cobbold R.S. On the design and evaluation of a steady flow model for Doppler ultrasound studies. Ultrasound Med Biol 1989, 15:505-516.
    • (1989) Ultrasound Med Biol , vol.15 , pp. 505-516
    • Law, Y.F.1    Johnston, K.W.2    Routh, H.F.3    Cobbold, R.S.4
  • 23
    • 0026066451 scopus 로고
    • Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz
    • Lockwood G.R., Ryan L.K., Hunt J.W., Foster F.S. Measurement of the ultrasonic properties of vascular tissues and blood from 35-65 MHz. Ultrasound Med Biol 1991, 17:653-666.
    • (1991) Ultrasound Med Biol , vol.17 , pp. 653-666
    • Lockwood, G.R.1    Ryan, L.K.2    Hunt, J.W.3    Foster, F.S.4
  • 24
    • 33846914713 scopus 로고    scopus 로고
    • Anatomical flow phantoms of the nonplanar carotid bifurcation, part II: Experimental validation with Doppler ultrasound
    • Meagher S., Poepping T.L., Ramnarine K.V., Black R.A., Hoskins P.R. Anatomical flow phantoms of the nonplanar carotid bifurcation, part II: Experimental validation with Doppler ultrasound. Ultrasound Med Biol 2007, 33:303-310.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 303-310
    • Meagher, S.1    Poepping, T.L.2    Ramnarine, K.V.3    Black, R.A.4    Hoskins, P.R.5
  • 25
    • 0038401196 scopus 로고    scopus 로고
    • A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies
    • Nadkarni S.K., Austin H., Mills G., Boughner D., Fenster A. A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies. Ultrasound Med Biol 2003, 29:621-628.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 621-628
    • Nadkarni, S.K.1    Austin, H.2    Mills, G.3    Boughner, D.4    Fenster, A.5
  • 26
    • 0036281213 scopus 로고    scopus 로고
    • An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation
    • Poepping T.L., Nikolov H.N., Rankin R.N., Lee M., Holdsworth D.W. An in vitro system for Doppler ultrasound flow studies in the stenosed carotid artery bifurcation. Ultrasound Med Biol 2002, 28:495-506.
    • (2002) Ultrasound Med Biol , vol.28 , pp. 495-506
    • Poepping, T.L.1    Nikolov, H.N.2    Rankin, R.N.3    Lee, M.4    Holdsworth, D.W.5
  • 28
    • 0035053447 scopus 로고    scopus 로고
    • Construction and geometric stability of physiological flow rate wall-less stenosis phantoms
    • Ramnarine K.V., Anderson T., Hoskins P.R. Construction and geometric stability of physiological flow rate wall-less stenosis phantoms. Ultrasound Med Biol 2001, 27:245-250.
    • (2001) Ultrasound Med Biol , vol.27 , pp. 245-250
    • Ramnarine, K.V.1    Anderson, T.2    Hoskins, P.R.3
  • 29
    • 0032033499 scopus 로고    scopus 로고
    • Validation of a new blood-mimicking fluid for use in Doppler flow test objects
    • Ramnarine K.V., Nassiri D.K., Hoskins P.R., Lubbers J. Validation of a new blood-mimicking fluid for use in Doppler flow test objects. Ultrasound Med Biol 1998, 24:451-459.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 451-459
    • Ramnarine, K.V.1    Nassiri, D.K.2    Hoskins, P.R.3    Lubbers, J.4
  • 31
    • 79954512249 scopus 로고    scopus 로고
    • A novel approach to predicting the lifetime of elastomers undergoing sress relaxation
    • [PhD thesis]
    • Ronan S. A novel approach to predicting the lifetime of elastomers undergoing sress relaxation. [PhD thesis] Dublin Institute of Technology, 2009.
    • (2009) Dublin Institute of Technology
    • Ronan, S.1
  • 32
    • 1642601653 scopus 로고    scopus 로고
    • Acoustic properties of aortic aneurysm obtained with scanning acoustic microscope
    • Saijo Y., Miyakawa T., Sasaki H., Tanaka M., Nitta S. Acoustic properties of aortic aneurysm obtained with scanning acoustic microscope. Ultrasonics 2004, 42:695-698.
    • (2004) Ultrasonics , vol.42 , pp. 695-698
    • Saijo, Y.1    Miyakawa, T.2    Sasaki, H.3    Tanaka, M.4    Nitta, S.5
  • 33
    • 0032168466 scopus 로고    scopus 로고
    • Acoustic properties of atherosclerosis of human aorta obtained with high-frequency ultrasound
    • Saijo Y., Sasaki H., Okawai H., Nitta S., Tanaka M. Acoustic properties of atherosclerosis of human aorta obtained with high-frequency ultrasound. Ultrasound Med Biol 1998, 24:1061-1064.
    • (1998) Ultrasound Med Biol , vol.24 , pp. 1061-1064
    • Saijo, Y.1    Sasaki, H.2    Okawai, H.3    Nitta, S.4    Tanaka, M.5
  • 34
    • 0024799170 scopus 로고
    • Doppler spectral waveform generation in vitro: An aid to diagnosis of vascular disease
    • Shortland A.P., Cochrane T. Doppler spectral waveform generation in vitro: An aid to diagnosis of vascular disease. Ultrasound Med. Biol 1989, 15:737-748.
    • (1989) Ultrasound Med. Biol , vol.15 , pp. 737-748
    • Shortland, A.P.1    Cochrane, T.2
  • 35
    • 12744271954 scopus 로고    scopus 로고
    • Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging
    • Surry K.J., Austin H.J., Fenster A., Peters T.M. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys Med Biol 2004, 49:5529-5546.
    • (2004) Phys Med Biol , vol.49 , pp. 5529-5546
    • Surry, K.J.1    Austin, H.J.2    Fenster, A.3    Peters, T.M.4
  • 37
    • 1842836414 scopus 로고    scopus 로고
    • Optimizing the tensile properties of polyvinyl alcohol hydrogel for the construction of a bioprosthetic heart valve stent
    • Wan W.K., Campbell G., Zhang Z.F., Hui A.J., Boughner D.R. Optimizing the tensile properties of polyvinyl alcohol hydrogel for the construction of a bioprosthetic heart valve stent. J Biomed Mater Res 2002, 63:854-861.
    • (2002) J Biomed Mater Res , vol.63 , pp. 854-861
    • Wan, W.K.1    Campbell, G.2    Zhang, Z.F.3    Hui, A.J.4    Boughner, D.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.