-
1
-
-
17444371294
-
Assessment of vulnerable plaque composition by matching the deformation of a parametric plaque model to measured plaque deformation
-
Baldewsing R.A., Schaar J.A., Mastik F., Oomens C.W.J., and van der Steen A.F.W. Assessment of vulnerable plaque composition by matching the deformation of a parametric plaque model to measured plaque deformation. IEEE Trans Med Imaging 24 (2005) 514-528
-
(2005)
IEEE Trans Med Imaging
, vol.24
, pp. 514-528
-
-
Baldewsing, R.A.1
Schaar, J.A.2
Mastik, F.3
Oomens, C.W.J.4
van der Steen, A.F.W.5
-
3
-
-
0038444298
-
Assessment of the acoustic properties of common tissue-mimicking test phantoms
-
Browne J.E., Ramnarine K.V., Watson A.J., and Hoskins P.R. Assessment of the acoustic properties of common tissue-mimicking test phantoms. Ultrasound Med Biol 29 (2003) 1053-1060
-
(2003)
Ultrasound Med Biol
, vol.29
, pp. 1053-1060
-
-
Browne, J.E.1
Ramnarine, K.V.2
Watson, A.J.3
Hoskins, P.R.4
-
4
-
-
0027516690
-
Distribution of circumferential stress in ruptured and stable atherosclerotic lesions. a structural analysis with histopathologic correlation
-
Cheng G.C., Loree H.M., Kamm R.D., Fishbein M.C., and Lee R.T. Distribution of circumferential stress in ruptured and stable atherosclerotic lesions. a structural analysis with histopathologic correlation. Circulation 87 (1993) 1179-1187
-
(1993)
Circulation
, vol.87
, pp. 1179-1187
-
-
Cheng, G.C.1
Loree, H.M.2
Kamm, R.D.3
Fishbein, M.C.4
Lee, R.T.5
-
5
-
-
0031021607
-
Polyvinyl alcohol cryogel: an ideal phantom material for MR studies of arterial flow and elasticity
-
Chu K.C., and Rutt B.K. Polyvinyl alcohol cryogel: an ideal phantom material for MR studies of arterial flow and elasticity. Mag Res Med 37 (1997) 314-319
-
(1997)
Mag Res Med
, vol.37
, pp. 314-319
-
-
Chu, K.C.1
Rutt, B.K.2
-
6
-
-
0031008569
-
A real vessel phantom for imaging experimentation
-
Dabrowski W., DunmoreBuyze J., Rankin R.N., Holdsworth D.W., and Fenster A. A real vessel phantom for imaging experimentation. Med Phys 24 (1997) 687-693
-
(1997)
Med Phys
, vol.24
, pp. 687-693
-
-
Dabrowski, W.1
DunmoreBuyze, J.2
Rankin, R.N.3
Holdsworth, D.W.4
Fenster, A.5
-
8
-
-
0034622623
-
Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro
-
de Korte C.L., Pasterkamp G., van der Steen A.F.W., Woutman H.A., and Bom N. Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro. Circulation 102 (2000) 617-623
-
(2000)
Circulation
, vol.102
, pp. 617-623
-
-
de Korte, C.L.1
Pasterkamp, G.2
van der Steen, A.F.W.3
Woutman, H.A.4
Bom, N.5
-
9
-
-
0034083493
-
Characterization of plaque components and vulnerability with intravascular ultrasound elastography
-
de Korte C.L., van der Steen A.F.W., Cespedes E.I., et al. Characterization of plaque components and vulnerability with intravascular ultrasound elastography. Phys Med Biol 45 (2000) 1465-1475
-
(2000)
Phys Med Biol
, vol.45
, pp. 1465-1475
-
-
de Korte, C.L.1
van der Steen, A.F.W.2
Cespedes, E.I.3
-
10
-
-
0027359446
-
Elasticity and geometry measurements of vascular specimens using a high-resolution laboratory CT scanner
-
Drangova M., Holdsworth D.W., Boyd C.J., et al. Elasticity and geometry measurements of vascular specimens using a high-resolution laboratory CT scanner. Physiol Meas 14 (1993) 277-290
-
(1993)
Physiol Meas
, vol.14
, pp. 277-290
-
-
Drangova, M.1
Holdsworth, D.W.2
Boyd, C.J.3
-
12
-
-
0003463950
-
Tissue characterization with ultrasound
-
Greenleaf J.F. (Ed), CRC Press Inc, Boca Raton, FL
-
Dunn F., and Goss S.A. Tissue characterization with ultrasound. In: Greenleaf J.F. (Ed). Chapter 1: Definition of Terms and Measurement of Acoustical Quantities (1986), CRC Press Inc, Boca Raton, FL 1-13
-
(1986)
Chapter 1: Definition of Terms and Measurement of Acoustical Quantities
, pp. 1-13
-
-
Dunn, F.1
Goss, S.A.2
-
13
-
-
33745138249
-
Acoustic speed and attenuation coefficient in sheep aorta measured at 5-9MHz
-
Fraser K.H., Poepping T.L., McNeilly A., Megson I.L., and Hoskins P.R. Acoustic speed and attenuation coefficient in sheep aorta measured at 5-9MHz. Ultrasound Med Biol 32 (2006) 971-980
-
(2006)
Ultrasound Med Biol
, vol.32
, pp. 971-980
-
-
Fraser, K.H.1
Poepping, T.L.2
McNeilly, A.3
Megson, I.L.4
Hoskins, P.R.5
-
14
-
-
0028896439
-
Diameter and compliance in the human common carotid artery-variations with age and sex
-
Hansen F., Mangell P., Sonneson B., and Lanne T. Diameter and compliance in the human common carotid artery-variations with age and sex. Ultrasound Med Biol 21 (1995) 1-9
-
(1995)
Ultrasound Med Biol
, vol.21
, pp. 1-9
-
-
Hansen, F.1
Mangell, P.2
Sonneson, B.3
Lanne, T.4
-
15
-
-
0024343930
-
A computer controlled flow phantom for generation of physiological Doppler waveforms
-
Hoskins P.R., Anderson T.A., and McDicken W.N. A computer controlled flow phantom for generation of physiological Doppler waveforms. Phys Med Biol 34 (1989) 1709-1717
-
(1989)
Phys Med Biol
, vol.34
, pp. 1709-1717
-
-
Hoskins, P.R.1
Anderson, T.A.2
McDicken, W.N.3
-
16
-
-
0345313017
-
Review of the design and use of flow phantoms
-
Hoskins P.R., Sherriff S.B., and Evans J.A. (Eds), IPEM, Bristol
-
Hoskins P.R. Review of the design and use of flow phantoms. In: Hoskins P.R., Sherriff S.B., and Evans J.A. (Eds). Testing of Doppler ultrasound systems (1994), IPEM, Bristol 12-29
-
(1994)
Testing of Doppler ultrasound systems
, pp. 12-29
-
-
Hoskins, P.R.1
-
17
-
-
0002419382
-
Doppler test devices
-
Evans D.H., and McDicken W.N. (Eds), Wiley, Hoboken, NJ
-
Hoskins P.R., and Ramnarine K.V. Doppler test devices. In: Evans D.H., and McDicken W.N. (Eds). Doppler ultrasound. 2nd ed. (2000), Wiley, Hoboken, NJ 382-404
-
(2000)
Doppler ultrasound. 2nd ed.
, pp. 382-404
-
-
Hoskins, P.R.1
Ramnarine, K.V.2
-
18
-
-
0038720995
-
-
IEC, International Electrotechnical Commission, Geneva, Switzerland IEC publication 61685
-
IEC. Ultrasonics - flow measurement systems - flow test object (2001), International Electrotechnical Commission, Geneva, Switzerland IEC publication 61685
-
(2001)
Ultrasonics - flow measurement systems - flow test object
-
-
-
19
-
-
8844221312
-
Compliance of abdominal aortic aneurysms: evaluation of tissue doppler imaging
-
Long A., Rouet L., Bissery A., et al. Compliance of abdominal aortic aneurysms: evaluation of tissue doppler imaging. Ultrasound Med Biol 30 (2004) 1099-1108
-
(2004)
Ultrasound Med Biol
, vol.30
, pp. 1099-1108
-
-
Long, A.1
Rouet, L.2
Bissery, A.3
-
20
-
-
0028089250
-
Mechanical properties of model atherosclerotic lesion lipid pools
-
Loree H.M., et al. Mechanical properties of model atherosclerotic lesion lipid pools. Arterioscler Thromb Vasc Biol 14 (1994) 230-234
-
(1994)
Arterioscler Thromb Vasc Biol
, vol.14
, pp. 230-234
-
-
Loree, H.M.1
-
21
-
-
0023019512
-
Interlaboratory comparison of ultrasonic-attenuation and speed neasurements
-
Madsen E.L., Frank G.R., Carson P.L., et al. Interlaboratory comparison of ultrasonic-attenuation and speed neasurements. J Ultrasound Med 5 (1986) 569-576
-
(1986)
J Ultrasound Med
, vol.5
, pp. 569-576
-
-
Madsen, E.L.1
Frank, G.R.2
Carson, P.L.3
-
22
-
-
0022878524
-
New polyvinyl-alcohol gel material for MRI phantoms
-
Mano I., Goshima H., Nambu M., and Iio M. New polyvinyl-alcohol gel material for MRI phantoms. Magn Reson Med 3 (1986) 921-926
-
(1986)
Magn Reson Med
, vol.3
, pp. 921-926
-
-
Mano, I.1
Goshima, H.2
Nambu, M.3
Iio, M.4
-
24
-
-
0032864119
-
Four-dimensional ultrasonographic characterization of plaque surface motion in patients with symptomatic and asymptomatic carotid artery stenosis
-
Meairs S., and Hennerici M. Four-dimensional ultrasonographic characterization of plaque surface motion in patients with symptomatic and asymptomatic carotid artery stenosis. Stroke 30 (1999) 1807-1813
-
(1999)
Stroke
, vol.30
, pp. 1807-1813
-
-
Meairs, S.1
Hennerici, M.2
-
25
-
-
0034971760
-
Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode
-
Meinders J.M., Brands P.J., Willigers J.M., Kornet L., and Hoeks A.P.G. Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode. Ultrasound Med Biol 27 (2001) 785-794
-
(2001)
Ultrasound Med Biol
, vol.27
, pp. 785-794
-
-
Meinders, J.M.1
Brands, P.J.2
Willigers, J.M.3
Kornet, L.4
Hoeks, A.P.G.5
-
26
-
-
0038401196
-
A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies
-
Nadkarni S.K., Austin H., Mills G., Boughner D., and Fenster A. A pulsating coronary vessel phantom for two- and three-dimensional intravascular ultrasound studies. Ultrasound Med Biol 29 (2003) 621-628
-
(2003)
Ultrasound Med Biol
, vol.29
, pp. 621-628
-
-
Nadkarni, S.K.1
Austin, H.2
Mills, G.3
Boughner, D.4
Fenster, A.5
-
29
-
-
0032033499
-
Validation of a new blood mimicking fluid for use in Doppler flow test objects
-
Ramnarine K.V., Nassiri D.K., Hoskins P.R., and Lubbers J. Validation of a new blood mimicking fluid for use in Doppler flow test objects. Ultrasound Med Biol 24 (1998) 451-459
-
(1998)
Ultrasound Med Biol
, vol.24
, pp. 451-459
-
-
Ramnarine, K.V.1
Nassiri, D.K.2
Hoskins, P.R.3
Lubbers, J.4
-
30
-
-
0030964904
-
Tissue equivalent vessel phantoms for intravascular ultrasound
-
Ryan L.K., and Foster F.S. Tissue equivalent vessel phantoms for intravascular ultrasound. Ultrasound Med Biol 23 (1997) 261-273
-
(1997)
Ultrasound Med Biol
, vol.23
, pp. 261-273
-
-
Ryan, L.K.1
Foster, F.S.2
-
31
-
-
12744271954
-
Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging
-
Surry K.J.M., Austin H.J.B., Fenster A., and Peters T.M. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging. Phys Med Biol 49 (2004) 5529-5546
-
(2004)
Phys Med Biol
, vol.49
, pp. 5529-5546
-
-
Surry, K.J.M.1
Austin, H.J.B.2
Fenster, A.3
Peters, T.M.4
-
32
-
-
0346216350
-
Investigation of carotid plaque motility
-
Price R., and Evans J.A. (Eds), Biological Engineering Society, London
-
White A., McCarty K., Morgan R., Wilkins J.P., and Woodcock J.P. Investigation of carotid plaque motility. In: Price R., and Evans J.A. (Eds). Blood flow measurement in clinical diagnosis (1988), Biological Engineering Society, London 109-115
-
(1988)
Blood flow measurement in clinical diagnosis
, pp. 109-115
-
-
White, A.1
McCarty, K.2
Morgan, R.3
Wilkins, J.P.4
Woodcock, J.P.5
-
33
-
-
0037285590
-
The relationship between aortic wall distensibility and rupture of infrarenal abdominal aortic aneurysms
-
Wilson K.A., Lee A.J., Hoskins P.R., et al. The relationship between aortic wall distensibility and rupture of infrarenal abdominal aortic aneurysms. J Vasc Surg 37 (2003) 112-117
-
(2003)
J Vasc Surg
, vol.37
, pp. 112-117
-
-
Wilson, K.A.1
Lee, A.J.2
Hoskins, P.R.3
|