-
1
-
-
0033057681
-
Polymer heart valves
-
Jonathan AJ, Hyde JA, Chinn RE, Phillips JR. Polymer heart valves, J Heart Valve Dis 1999;18:331-339.
-
(1999)
J Heart Valve Dis
, vol.18
, pp. 331-339
-
-
Jonathan, A.J.1
Hyde, J.A.2
Chinn, R.E.3
Phillips, J.R.4
-
2
-
-
0026550699
-
Durability of porcine valves at fifteen years in a representative North American patient population
-
Burton TA et al. Durability of porcine valves at fifteen years in a representative North American patient population. J Thorac Cardiovasc Surg 1992;103:238-252.
-
(1992)
J Thorac Cardiovasc Surg
, vol.103
, pp. 238-252
-
-
Burton, T.A.1
-
4
-
-
0022623739
-
Comparative study of primary tissue valve failure between Ionescu-Shiley pericardial and Hancock porcine valves in the aorta position
-
Nistal F, Garcia SE, Artinano E, Duran C, Gallo I. Comparative study of primary tissue valve failure between Ionescu-Shiley pericardial and Hancock porcine valves in the aorta position. American J Cardiol 1986;57:161-164.
-
(1986)
American J Cardiol
, vol.57
, pp. 161-164
-
-
Nistal, F.1
Garcia, S.E.2
Artinano, E.3
Duran, C.4
Gallo, I.5
-
5
-
-
0020660663
-
Long term failure rate and morphologic correlations in porcine bioprosthetic heart valves
-
Schoen FJ, Collins JJ, Cohn LH. Long term failure rate and morphologic correlations in porcine bioprosthetic heart valves. Am J Cardiol 1983;51:957-964.
-
(1983)
Am J Cardiol
, vol.51
, pp. 957-964
-
-
Schoen, F.J.1
Collins, J.J.2
Cohn, L.H.3
-
8
-
-
0017693223
-
An in vivo study of the dimensional changes of the aortic valve leaflets during the cardiac cycle
-
Brewer RJ, Mentzer RM Jr., Deck JD, Ritter RC, Trefil JS, Nolan SP. An in vivo study of the dimensional changes of the aortic valve leaflets during the cardiac cycle. J Thorac Cadriovasc Surg 1977;74:645-650.
-
(1977)
J Thorac Cadriovasc Surg
, vol.74
, pp. 645-650
-
-
Brewer, R.J.1
Mentzer R.M., Jr.2
Deck, J.D.3
Ritter, R.C.4
Trefil, J.S.5
Nolan, S.P.6
-
9
-
-
0029117077
-
Longitudinal and radial distensibility of the porcine aortic root
-
Hansen B, Menkis AH, Vesely I. Longitudinal and radial distensibility of the porcine aortic root, Ann Thorac Surg 1995;60:384-390.
-
(1995)
Ann Thorac Surg
, vol.60
, pp. 384-390
-
-
Hansen, B.1
Menkis, A.H.2
Vesely, I.3
-
10
-
-
0025499734
-
A computerized system for video analysis of the aortic valve
-
Vesely I, Menkis AH, Campbell G. A computerized system for video analysis of the aortic valve. IEEE Trans Biomed Eng 1990;37:925-929.
-
(1990)
IEEE Trans Biomed Eng
, vol.37
, pp. 925-929
-
-
Vesely, I.1
Menkis, A.H.2
Campbell, G.3
-
11
-
-
0027248659
-
Geometry of homograft valve leaflets: Effect of dilation of the aorta and the aortic root
-
Lockie KJ, Butterfield M, Fisher J, Juster NP, Watterson K, Davies GA. Geometry of homograft valve leaflets: Effect of dilation of the aorta and the aortic root. Ann Thorac Surg 1993;56:125-130.
-
(1993)
Ann Thorac Surg
, vol.56
, pp. 125-130
-
-
Lockie, K.J.1
Butterfield, M.2
Fisher, J.3
Juster, N.P.4
Watterson, K.5
Davies, G.A.6
-
12
-
-
0016334717
-
Dimensions and geometric relationships of the human aortic valve as a function of pressure
-
Swanson WM, Clark RE. Dimensions and geometric relationships of the human aortic valve as a function of pressure. Circ Res 1974;35:871-882.
-
(1974)
Circ Res
, vol.35
, pp. 871-882
-
-
Swanson, W.M.1
Clark, R.E.2
-
13
-
-
0028413699
-
An optimal mounting frame to reduce flexural stresses of bioprosthetic heart valves
-
Vesely I, Krucinski S, Dokainish MA, Campbell G. An optimal mounting frame to reduce flexural stresses of bioprosthetic heart valves. ASAIO J 1994;199-205.
-
(1994)
ASAIO J
, pp. 199-205
-
-
Vesely, I.1
Krucinski, S.2
Dokainish, M.A.3
Campbell, G.4
-
14
-
-
0020268622
-
A polyurethane triflet cardiac valve prosthesis: In vitro and in vivo studies
-
Wisman CB, Pierce WS, Donachy JH, Pae WE, Myers JL, Prophet GA. A polyurethane triflet cardiac valve prosthesis: In vitro and in vivo studies. Trans Am Soc Artif Intern Organs 1982;28:164-168.
-
(1982)
Trans Am Soc Artif Intern Organs
, vol.28
, pp. 164-168
-
-
Wisman, C.B.1
Pierce, W.S.2
Donachy, J.H.3
Pae, W.E.4
Myers, J.L.5
Prophet, G.A.6
-
16
-
-
0023190037
-
Evaluation of explanted polyurethane triflet cardiac valve prosthesis
-
Hilbert ST, Ferrans VJ, Tomita Y, Eidbo EE, Jones M. Evaluation of explanted polyurethane triflet cardiac valve prosthesis J Thorac Cardiovasc Surg 1987;94:419-429.
-
(1987)
J Thorac Cardiovasc Surg
, vol.94
, pp. 419-429
-
-
Hilbert, S.T.1
Ferrans, V.J.2
Tomita, Y.3
Eidbo, E.E.4
Jones, M.5
-
17
-
-
0003867545
-
-
Ratner BD, Hoffman AS, Schoen FJ, Lemons JE, Eds. Academic, Toronto
-
Peppas NA. Biomaterials Science: An Introduction to Materials in Medicine. In: Ratner BD, Hoffman AS, Schoen FJ, Lemons JE, Eds. Academic, Toronto; 1996. p 62.
-
(1996)
Biomaterials Science: An Introduction to Materials in Medicine
, pp. 62
-
-
Peppas, N.A.1
-
18
-
-
0002770914
-
Synthetic hydrogels for biomedical applications
-
Andrade JD, editor, ACS Symposium Series, American Chemical Society, Washington, DC
-
Ratner BD, Hoffman AS. Synthetic hydrogels for biomedical applications. In Andrade JD, editor, Hydrogels for Medical and Related Applications, ACS Symposium Series, American Chemical Society, Washington, DC; 1985. Vol. 31, p 14.
-
(1985)
Hydrogels for Medical and Related Applications
, vol.31
, pp. 14
-
-
Ratner, B.D.1
Hoffman, A.S.2
-
19
-
-
0015669545
-
PVA hydrogel for synthetic articular cartilage material
-
Bray JC, Marty EW. PVA hydrogel for synthetic articular cartilage material. J Biomed Mater Res 1973;7:431.
-
(1973)
J Biomed Mater Res
, vol.7
, pp. 431
-
-
Bray, J.C.1
Marty, E.W.2
-
20
-
-
0001925374
-
Anomalous increase of the elastic modulus of frozen poly(vinyl alcohol) gels
-
Watase M, Nishinari K, Nambu M. Anomalous increase of the elastic modulus of frozen poly(vinyl alcohol) gels. Cryo-Letters 1983;4:197-200.
-
(1983)
Cryo-Letters
, vol.4
, pp. 197-200
-
-
Watase, M.1
Nishinari, K.2
Nambu, M.3
-
21
-
-
0025885279
-
Reinforced uncrosslinked poly(vinyl alcohol) gels produced by cyclic freezing-thawing processes: A short review
-
Peppas NA. Stauffer SR. Reinforced uncrosslinked poly(vinyl alcohol) gels produced by cyclic freezing-thawing processes: A short review. J Controlled Release 1991;16:305-310.
-
(1991)
J Controlled Release
, vol.16
, pp. 305-310
-
-
Peppas, N.A.1
Stauffer, S.R.2
-
22
-
-
0001664446
-
Poly(vinyl alcohol) hydrogels prepared by freezing-thawing cyclic processing
-
Stauffer SR, Peppas NA. Poly(vinyl alcohol) hydrogels prepared by freezing-thawing cyclic processing, Polymer 1992;33: 3932-3936.
-
(1992)
Polymer
, vol.33
, pp. 3932-3936
-
-
Stauffer, S.R.1
Peppas, N.A.2
-
25
-
-
33751268423
-
The reason for the shape of the distensibility curves of arteries
-
Roach MR, Burton AC. The reason for the shape of the distensibility curves of arteries, Can J Biochem Physiol 1957;35:681.
-
(1957)
Can J Biochem Physiol
, vol.35
, pp. 681
-
-
Roach, M.R.1
Burton, A.C.2
-
26
-
-
0024427911
-
Effects of age on the anisotropy of the descending human thoracic aorta determined by uniaxial tensile testing and digestion by NaOH under load
-
Sherebrin MH, Hegney JE, Roach MR. Effects of age on the anisotropy of the descending human thoracic aorta determined by uniaxial tensile testing and digestion by NaOH under load. Can J Physiol Pharmacol 1989;67:871.
-
(1989)
Can J Physiol Pharmacol
, vol.67
, pp. 871
-
-
Sherebrin, M.H.1
Hegney, J.E.2
Roach, M.R.3
-
27
-
-
0022386915
-
Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium
-
Lee JM, Boughner DR. Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium. Circ Res 1985;55:475-481.
-
(1985)
Circ Res
, vol.55
, pp. 475-481
-
-
Lee, J.M.1
Boughner, D.R.2
-
28
-
-
0024673537
-
The bovine pericardial xenograft: I Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium
-
Lee JM, Haberer SA, Boughner DR. The bovine pericardial xenograft: I Effect of fixation in aldehydes without constraint on the tensile viscoelastic properties of bovine pericardium. J Biomed Mater Res 1989;23:457-475.
-
(1989)
J Biomed Mater Res
, vol.23
, pp. 457-475
-
-
Lee, J.M.1
Haberer, S.A.2
Boughner, D.R.3
-
29
-
-
0028870202
-
Porcine pulmonary and aortic valves: A comparison of their tensile viscoelastic properties at physiological strain rates
-
Leeson-Dietrich J, Boughner DR, Vesely I. Porcine pulmonary and aortic valves: A comparison of their tensile viscoelastic properties at physiological strain rates. J Heart Valve Diseases 1995;4:88-94.
-
(1995)
J Heart Valve Diseases
, vol.4
, pp. 88-94
-
-
Leeson-Dietrich, J.1
Boughner, D.R.2
Vesely, I.3
-
30
-
-
0021787582
-
The mechanical response of glutaraldehyde fixed bovine pericardium to uniaxial load
-
Trowbridge EA, Black MM, Daniel CL. The mechanical response of glutaraldehyde fixed bovine pericardium to uniaxial load. J Mater Sci 1985;20:114-140.
-
(1985)
J Mater Sci
, vol.20
, pp. 114-140
-
-
Trowbridge, E.A.1
Black, M.M.2
Daniel, C.L.3
-
31
-
-
0033667525
-
The pericardial bioprothesis: Altered tissue shear properties following glutaraldehyde fixation
-
Boughner DR, Haldenby M, Dunmore-Buyze J, Talman E, Hui A, Wan WK. The pericardial bioprothesis: Altered tissue shear properties following glutaraldehyde fixation. J Heart Valve Dis 2000;9:752-760.
-
(2000)
J Heart Valve Dis
, vol.9
, pp. 752-760
-
-
Boughner, D.R.1
Haldenby, M.2
Dunmore-Buyze, J.3
Talman, E.4
Hui, A.5
Wan, W.K.6
-
32
-
-
0018425356
-
Experimental evaluation of aortic homograft valves mounted on flexible support frames and comparison with glutaraldehyde-treated porcine valves
-
Pohlner PG, Thomson FJ, Hjelms E, Barratt-Boyes BG. Experimental evaluation of aortic homograft valves mounted on flexible support frames and comparison with glutaraldehyde-treated porcine valves. J Thorac Cardiovasc Surg 1979;77:287-293.
-
(1979)
J Thorac Cardiovasc Surg
, vol.77
, pp. 287-293
-
-
Pohlner, P.G.1
Thomson, F.J.2
Hjelms, E.3
Barratt-Boyes, B.G.4
|