-
1
-
-
79953834830
-
Heart sound measurement and analysis in cardiovascular disease assessment
-
Eveloy V, Liu Y, Pecht M. Heart sound measurement and analysis in cardiovascular disease assessment. Surface Mount Technology Association (SMTA), Proceedings of the SMTA Medical Electronics Symposium, Minneapolis, MN, April 25-27, 2005.
-
Surface Mount Technology Association (SMTA), Proceedings of the SMTA Medical Electronics Symposium, Minneapolis, MN, April 25-27, 2005
-
-
Eveloy, V.1
Liu, Y.2
Pecht, M.3
-
2
-
-
79953829269
-
Non-invasive electrocardiogram and blood pressure monitors for cardiovascular disease
-
Philadelphia, PA, September 25-29
-
Liu Y, Eveloy V, Pecht M. Non-invasive electrocardiogram and blood pressure monitors for cardiovascular disease. 38th International Symposium on Microelectronics, Sensor and MEMS Packaging, pp. 66-74. Philadelphia, PA, September 25-29, 2005.
-
(2005)
38th International Symposium on Microelectronics, Sensor and MEMS Packaging
, pp. 66-74
-
-
Liu, Y.1
Eveloy, V.2
Pecht, M.3
-
4
-
-
33745654794
-
Developments in ambulatory electrocardiography
-
DOI 10.2345/i0899-8205-40-3-238.1
-
Eveloy V, Liu Y, Pecht M. Developments in ambulatory electrocardiography. Biomed Instrumen Technol. 40(3): May/June 2006; 238-245. (Pubitemid 43970408)
-
(2006)
Biomedical Instrumentation and Technology
, vol.40
, Issue.3
, pp. 238-245
-
-
Eveloy, V.1
Liu, Y.2
Pecht, M.G.3
-
6
-
-
0035195586
-
ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography
-
Kadish AH. ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography. J Am Coll Cardiol. 38(7):2001; 2091-2100.
-
(2001)
J Am Coll Cardiol
, vol.38
, Issue.7
, pp. 2091-2100
-
-
Kadish, A.H.1
-
7
-
-
11244283168
-
Electrocardiographic motion artifact versus electrode impedance
-
DOI 10.1109/TBME.2004.836503
-
Wiese SR, Anheier P, Connemara RD, Mollner AT, Neils TF, Kahn JA, Webster JG. Electrocardiographic motion artifact versus electrode impedance. IEEE Transactions Biomed Engineer. 52(1):2005; 136-139. (Pubitemid 40065619)
-
(2005)
IEEE Transactions on Biomedical Engineering
, vol.52
, Issue.1
, pp. 136-139
-
-
Wiese, S.R.1
Anheier, P.2
Connemara, R.D.3
Mollner, A.T.4
Neils, T.F.5
Kahn, J.A.6
Webster, J.G.7
-
8
-
-
0025267657
-
A comparison of the noise sensitivity of nine QRS detection algorithms
-
DOI 10.1109/10.43620
-
Friesen GM, Jannett TC, Jadallah MA, Yates SL, Quint SR, Nagle HT. Comparison of the noise sensitivity of nine QRS detection algorithms. IEEE Transactions Biomed Engineer. 37(1):1990; 85-98. (Pubitemid 20123439)
-
(1990)
IEEE Transactions on Biomedical Engineering
, vol.37
, Issue.1
, pp. 85-98
-
-
Friesen, G.M.1
Jannett, T.C.2
Afify, J.M.3
Yates, S.L.4
Qu, I.S.R.5
Troy, N.H.6
-
9
-
-
0021312851
-
Rx for ECG monitoring artifact
-
Smith M. Rx for ECG monitoring artifact. Critical Care Nurse. 4(1):1984; 64-66.
-
(1984)
Critical Care Nurse
, vol.4
, Issue.1
, pp. 64-66
-
-
Smith, M.1
-
11
-
-
0017368294
-
Minimizing electrode motion artifact by skin abrasion
-
Tam RW, Webster JG. Minimizing electrode motion artifact by skin abrasion. IEEE Transactions Biomed Engineer. BME-29:1977; 134-139.
-
(1977)
IEEE Transactions Biomed Engineer
, vol.BME-29
, pp. 134-139
-
-
Tam, R.W.1
Webster, J.G.2
-
13
-
-
0021645224
-
Reducing motion artifacts and interference in biopotential recording
-
Webster JG. Reducing motion artifacts and interference in biopotential recording. IEEE Transactions Biomed Engineer. BME-31(12):1984; 823-826.
-
(1984)
IEEE Transactions Biomed Engineer
, vol.BME-31
, Issue.12
, pp. 823-826
-
-
Webster, J.G.1
-
14
-
-
0029974333
-
The origin of skin-stretch-caused motion artifacts under electrodes
-
de Talhouet H, Webster JG. The origin of skin-stretch-caused motion artifacts under electrodes. Physiological Measurement, vol. 17, pp. 81-93, 1996.
-
(1996)
Physiological Measurement
, vol.17
, pp. 81-93
-
-
De Talhouet, H.1
Webster, J.G.2
-
20
-
-
0021642246
-
Detection of electrode motion noise in ECG signals by monitoring electrode impedance
-
Devlin PH, Mark RG, Ketchum JW. Detection of electrode motion noise in ECG signals by monitoring electrode impedance. Computers Cardiol. 1984; 51-56.
-
(1984)
Computers Cardiol
, pp. 51-56
-
-
Devlin, P.H.1
Mark, R.G.2
Ketchum, J.W.3
-
21
-
-
0029518501
-
Experimental study: Brachial motion artifact reduction in the ECG
-
Luo S, Tompkins WJ. Experimental study: brachial motion artifact reduction in the ECG. Computers Cardiol. 1995; 33-36.
-
(1995)
Computers Cardiol
, pp. 33-36
-
-
Luo, S.1
Tompkins, W.J.2
-
22
-
-
34047136656
-
Reduction of Skin Stretch Induced Motion Artifacts in Electrocardiogram Monitoring Using Adaptive Filtering
-
Liu Y, Pecht M. Reduction of Skin Stretch Induced Motion Artifacts in Electrocardiogram Monitoring Using Adaptive Filtering. 28th International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering Revolution In BioMedicine, New York, NY, August 31-September 3, 2006.
-
28th International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering Revolution in BioMedicine, New York, NY, August 31-September 3, 2006
-
-
Liu, Y.1
Pecht, M.2
-
23
-
-
0020154326
-
On the spread of deformation potentials in the skin
-
DOI 10.1007/BF02442405
-
Odman S. On the spread of deformation potentials in the skin. Med Biolog Engineer Computing. 20:1982; 451-456. (Pubitemid 12040944)
-
(1982)
Medical and Biological Engineering and Computing
, vol.20
, Issue.4
, pp. 451-456
-
-
Odman, S.1
-
24
-
-
0026203883
-
Applications of adaptive filtering to ECG analysis: Noise cancellation and arrhythmia detection
-
Thakor NV, Zhu Y. Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection. IEEE Transactions on Biomedical Engineering. 38(8):1991; 785-794.
-
(1991)
IEEE Transactions on Biomedical Engineering
, vol.38
, Issue.8
, pp. 785-794
-
-
Thakor, N.V.1
Zhu, Y.2
-
25
-
-
0016643045
-
Adaptive noise canceling: Principles and applications
-
Widrow B, Glover JR, McCool JM, Kaunitz J, Williams CS, Hearn RH, Zeidler JR, Dong E, Goodlin RC. Adaptive noise canceling: principles and applications. Proceedings of the IEEE. 63(12):1975; 1692-1716.
-
(1975)
Proceedings of the IEEE
, vol.63
, Issue.12
, pp. 1692-1716
-
-
Widrow, B.1
Glover, J.R.2
McCool, J.M.3
Kaunitz, J.4
Williams, C.S.5
Hearn, R.H.6
Zeidler, J.R.7
Dong, E.8
Goodlin, R.C.9
-
26
-
-
0019572182
-
Potential and impedance variations following skin deformation
-
DOI 10.1007/BF02442544
-
Odman S. Potential and impedance variations following skin deformation. Med Biolog Engineer Computing. 19:1981; 271-278. (Pubitemid 11097031)
-
(1981)
Medical and Biological Engineering and Computing
, vol.19
, Issue.3
, pp. 271-278
-
-
Odman, S.1
|