메뉴 건너뛰기




Volumn 2, Issue , 2002, Pages 1756-1757

Adaptive noise cancelling of motion artifact in stress ECG signals using accelerometer

Author keywords

Accelerometer; Adaptive filtering; Exercise ECG; LMS; Motion artifact; Noise cancellation; RLS; Stress ECG

Indexed keywords

ACCELEROMETERS; ADAPTIVE FILTERING; CARDIOLOGY; ELECTROCARDIOGRAPHY; LEAST SQUARES APPROXIMATIONS; SPURIOUS SIGNAL NOISE;

EID: 0036911208     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (93)

References (8)
  • 1
    • 0026203883 scopus 로고
    • Applications of adaptive filtering to ECG analysis: Noise cancellation and arrhythmia detection
    • August
    • N.V. Thakor and Y. Zhu, "Applications of adaptive filtering to ECG analysis: noise Cancellation and arrhythmia detection," IEEE Trans. Biomedical Engineering, Vol. 38, No. 8, pp. 785-794, August 1991.
    • (1991) IEEE Trans. Biomedical Engineering , vol.38 , Issue.8 , pp. 785-794
    • Thakor, N.V.1    Zhu, Y.2
  • 2
    • 0016643045 scopus 로고
    • Adaptive noise cancelling: Principles and applications
    • December
    • B. Widrow, et al., "Adaptive noise cancelling: principles and applications," IEEE Proc., Vol. 63, No. 12, pp.1692-1716, December 1975.
    • (1975) IEEE Proc. , vol.63 , Issue.12 , pp. 1692-1716
    • Widrow, B.1
  • 3
    • 0012108030 scopus 로고
    • Adaptive systems in ECG processing
    • Ph.D Dissertation, Technical University of Brno, Czechoslovakia
    • I. Provaznik, "Adaptive Systems in ECG Processing," Ph.D Dissertation, Technical University of Brno, Czechoslovakia, 1995.
    • (1995)
    • Provaznik, I.1
  • 4
    • 0029518501 scopus 로고
    • Experimental study: Brachial motion artifact reduction in the ECG
    • W.J. Tompkins and S. Luo, "Experimental study: brachial motion artifact reduction in the ECG," IEEE Trans. Computers in Cardiology, pp. 33-36, 1995.
    • (1995) IEEE Trans. Computers in Cardiology , pp. 33-36
    • Tompkins, W.J.1    Luo, S.2
  • 5
    • 4243742454 scopus 로고    scopus 로고
    • Investigation into electrocardiogram motion artifact reduction, 10-9191
    • IR&D Southwest Research Institute. April 1
    • D.A. Tong, "Investigation into electrocardiogram motion artifact reduction, 10-9191," IR&D Southwest Research Institute. April 1, 2000.
    • (2000)
    • Tong, D.A.1
  • 7
    • 0026119071 scopus 로고
    • Methods to assess physical activity with special reference to motion sensors and accelerometers
    • March
    • G. Meijer, K.Westerterp, F. Verhoeven, H. Koper, and F. Hoor, "Methods to assess physical activity with special reference to motion sensors and accelerometers," IEEE Trans. Biomedical Engineering, Vol. 38, No. 3, pp.221-229, March 1991.
    • (1991) IEEE Trans. Biomedical Engineering , vol.38 , Issue.3 , pp. 221-229
    • Meijer, G.1    Westerterp, K.2    Verhoeven, F.3    Koper, H.4    Hoor, F.5
  • 8
    • 0031106807 scopus 로고    scopus 로고
    • A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity
    • March
    • C.V.C. Bouten, "A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity," IEEE Trans. Biomedical Engineering, Vol. 44, No. 3, pp. 136-147, March 1997.
    • (1997) IEEE Trans. Biomedical Engineering , vol.44 , Issue.3 , pp. 136-147
    • Bouten, C.V.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.